<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; OFP-100-M</title>
	<atom:link href="http://www.faxytech.com/tag/ofp-100-m/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>福禄克OptiFiber PRO测试整卷光纤线路方案</title>
		<link>http://www.faxytech.com/archives/optifiber-zxq.html</link>
		<comments>http://www.faxytech.com/archives/optifiber-zxq.html#comments</comments>
		<pubDate>Fri, 17 Jul 2015 05:23:47 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[OFP-100-M]]></category>
		<category><![CDATA[OFP-100-Q]]></category>
		<category><![CDATA[OFP-100-S]]></category>
		<category><![CDATA[OptiFiber]]></category>
		<category><![CDATA[光纤]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6449</guid>
		<description><![CDATA[如何更好的测试整箱光纤线。我们可以利用福禄克网络的OptiFiber PRO系列的OFP-100-M测试多模，OFP-100-S测试单模，OFP-100-Q测试单多模。测试的时候千万不要网络两端都测试，如果长度相同，代表整... ]]></description>
			<content:encoded><![CDATA[<p>如何更好的测试整箱<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4" title="查看 光纤 的全部文章" target="_blank">光纤</a></span>线。我们可以利用福禄克网络的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> PRO系列的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-m.html" title="fluke OFP-100-M">OFP-100-M</a></span>测试多模，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-s.html" title="福禄克Fluke OFP-100-S">OFP-100-S</a></span>测试单模，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span>测试单多模。测试的时候千万不要网络两端都测试，如果长度相同，代表整箱光纤线路是没问题的，如果测试的长度不同，那么代表光纤线在中间有断开的情况。需要引起注意。</p>
<p>我们在安装光缆的时候，应该每卷光纤线都要测试，因为如果等你装上去的时候，发现有问题将是非常大的麻烦。重新改正一条光缆的费用都大约重新铺一条光纤了。如果你没有福禄克的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/optifiber" title="查看 OptiFiber 的全部文章" target="_blank">OptiFiber</a></span> PRO光纤（<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-m" title="查看 OFP-100-M 的全部文章" target="_blank">OFP-100-M</a></span>测试多模，<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-s" title="查看 OFP-100-S 的全部文章" target="_blank">OFP-100-S</a></span>测试单模<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-q" title="查看 OFP-100-Q 的全部文章" target="_blank">OFP-100-Q</a></span>测试单模）的任一型号，那么可以使用福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/simplifiber-pro.html" title="福禄克FLUKE SimpliFiber Pro光纤测试仪">SimpliFiber</a></span> PRO光功率计进行测试，千万不用Visifualt或者其他品牌红光笔测试，因为即使光纤中部有损耗，在末端也能看到红色光源</p>
<p><img class="alignnone size-full wp-image-6454" title="福禄克FLuke OptiFiber OFP-100-Q测试整箱网线图片" src="http://www.faxytech.com/wp-content/uploads/2015/07/OptiFiber.jpg" alt="福禄克FLuke OptiFiber OFP-100-Q测试整箱网线图片" width="560" height="272" /></p>
<p>OptiFiber? Pro <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span> 通过业界唯一的智能手机界面提高了光纤测试的高度，让每一名技师都成为光纤专家。 DataCenter OTDR 配置可减少对数据中心光纤进行测试时所发生的不确定性和错误。 其超短的死区允许在虚拟数据中心进行光纤跳线测试。 这些功能，以及业界最快的扫描时间，使?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-optifiber-pro-otdr.html" title="福禄克Fluke OptiFiber Pro">OptiFiber Pro</a></span> OTDR 成为您的必备工具。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/optifiber-zxq.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克FLuke OFP-100-M技术参数规格选型</title>
		<link>http://www.faxytech.com/archives/ofp-100-m-tech.html</link>
		<comments>http://www.faxytech.com/archives/ofp-100-m-tech.html#comments</comments>
		<pubDate>Thu, 02 Apr 2015 05:41:08 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[linkware]]></category>
		<category><![CDATA[OFP-100-M]]></category>
		<category><![CDATA[OTDR]]></category>
		<category><![CDATA[光纤测试仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=5995</guid>
		<description><![CDATA[福禄克FLuke OFP-100-M技术参数规格选型： (1)设备功能 本设备是为局域网和城域网光缆设计，可以满足最新光缆认证和测试需求的仪器。它将插入损耗和光缆长度测量、OTDR?分析和光缆连接头端接... ]]></description>
			<content:encoded><![CDATA[<p>福禄克FLuke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-m.html" title="fluke OFP-100-M">OFP-100-M</a></span>技术参数规格选型：</p>
<p>(1)设备功能</p>
<p>本设备是为局域网和城域网光缆设计，可以满足最新光缆认证和测试需求的仪器。它将<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>和光缆长度测量、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>?分析和光缆连接头端接面洁净度检查集成在一台仪器中，提供更高级的光缆认证和故障诊断。随机附带的?<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>?PC?软件可以管理所有的测试数据，对它们进行文档备案、生成测试报告。</p>
<p>(2)主要技术参数</p>
<table>
<tbody>
<tr>
<td rowspan="10" width="138" valign="center">功能</td>
<td width="457" valign="center">首创智能手机界面的?<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/otdr" title="查看 OTDR 的全部文章" target="_blank">OTDR</a></span>，中文界面，多点触摸屏</td>
</tr>
<tr>
<td width="457" valign="center">全自动测试，以最快速的设定和追踪时间加速光纤验证</td>
</tr>
<tr>
<td width="457" valign="center">证，业界最短事件和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>死区</td>
</tr>
<tr>
<td width="457" valign="center">支持自动端口质量检测</td>
</tr>
<tr>
<td width="457" valign="center">EventMap??视图简化使用方式</td>
</tr>
<tr>
<td width="457" valign="center">模块化设计，便携，轻巧</td>
</tr>
<tr>
<td width="457" valign="center">LinkWare报告管理，支持测试结果统计</td>
</tr>
<tr>
<td width="457" valign="center">通过项目和用户的自定义配置提高资源利用率</td>
</tr>
<tr>
<td width="457" valign="center">自定义项目文件夹</td>
</tr>
<tr>
<td width="457" valign="center">独特的“DataCenter?OTDR?”模式</td>
</tr>
<tr>
<td width="138" valign="center">波长：</td>
<td width="457" valign="center">850?nm?+/-?10?nm，1300?nm?+35/-15?nm<br />
1310?nm?+/-?25?nm，1550?nm?+/-?30?nm</td>
</tr>
<tr>
<td width="138" valign="center">可测试光缆类型：</td>
<td width="457" valign="center">50/125??m<br />
62.5/125??m</td>
</tr>
<tr>
<td width="138" valign="center">事件死区：</td>
<td width="457" valign="center">850?nm?：0.5?m（典型）<br />
1300?nm?：0.7?m（典型）<br />
1310/1550?nm?：0.6?m（典型）</td>
</tr>
<tr>
<td width="138" valign="center">衰减死区：</td>
<td width="457" valign="center">850?nm?：2.5?m（典型）<br />
1300?nm?：4.5?m（典型）<br />
1310?nm?：3.6?m（典型）<br />
1550?nm?：3.7?m（典型）</td>
</tr>
<tr>
<td width="138" valign="center">最大长度范围：</td>
<td width="457" valign="center">850?nm?：9?km，1300?nm?：35?km<br />
1310?nm?：80?km，1550?nm?：130?km</td>
</tr>
<tr>
<td width="138" valign="center">测试速度：</td>
<td width="457" valign="center">自动?OTDR?5秒</td>
</tr>
<tr>
<td width="138" valign="center">采样间隔：</td>
<td width="457" valign="center">3?cm至400?cm</td>
</tr>
<tr>
<td width="138" valign="center">参考重量：</td>
<td width="457" valign="center">1.28kg</td>
</tr>
<tr>
<td width="138" valign="center">尺寸：</td>
<td width="457" valign="center">（6.67?厘米?x?13.33?厘米?x27.94?厘米）</td>
</tr>
<tr>
<td width="138" valign="center">电池：</td>
<td width="457" valign="center">锂离子电池</td>
</tr>
<tr>
<td width="138" valign="center">电池使用时间：</td>
<td width="457" valign="center">连续自动OTDR测试8小时</td>
</tr>
</tbody>
</table>
<p>参考阅读：<a href="http://www.faxytech.com/archives/fluke-optifiber-pro-otdr.html">http://www.faxytech.com/archives/fluke-optifiber-pro-otdr.html</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/ofp-100-m-tech.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克Fluke OptiFiber PRO(OFP-100-M,OFP-100-S,OFP-100-Q)如何测试？操作说明手册</title>
		<link>http://www.faxytech.com/archives/optifiber-test.html</link>
		<comments>http://www.faxytech.com/archives/optifiber-test.html#comments</comments>
		<pubDate>Tue, 13 Jan 2015 09:13:42 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[ofp]]></category>
		<category><![CDATA[OFP-100-M]]></category>
		<category><![CDATA[OFP-100-Q]]></category>
		<category><![CDATA[OFP-100-S]]></category>
		<category><![CDATA[OptiFiber Pro]]></category>
		<category><![CDATA[otdr测试]]></category>
		<category><![CDATA[操作手册]]></category>
		<category><![CDATA[操作说明]]></category>
		<category><![CDATA[用户手册]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=5655</guid>
		<description><![CDATA[深圳市连讯达电子技术开发有限公司作为福禄克核心经销商，专业18年技术服务。特别优惠的价格，赢得了广大客户的好评。今天为大家介绍福禄克Fluke OptiFiber PRO(OFP-100-M,OFP-100-S,OFP-100-Q)如何测... ]]></description>
			<content:encoded><![CDATA[<p>深圳市连讯达电子技术开发有限公司作为福禄克核心经销商，专业18年技术服务。特别优惠的价格，赢得了广大客户的好评。今天为大家介绍福禄克Fluke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> PRO(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-m.html" title="fluke OFP-100-M">OFP-100-M</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-s.html" title="福禄克Fluke OFP-100-S">OFP-100-S</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span>)如何测试及操作注意事项。</p>
<p><span style="color: #800000;"><strong>1. 将测试仪通电必要时请给电池充电。</strong></span></p>
<p><span style="color: #800000;"><strong> </strong></span>将Fluke OptiFiber PRO(<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-m" title="查看 OFP-100-M 的全部文章" target="_blank">OFP-100-M</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-s" title="查看 OFP-100-S 的全部文章" target="_blank">OFP-100-S</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-q" title="查看 OFP-100-Q 的全部文章" target="_blank">OFP-100-Q</a></span>)交流适配器连接到交流电源和图1所示的适配器连接器(L)。测试仪在电池充电时也可以使用。</p>
<p><strong><span style="color: #800000;">2. 选择设置2-1 在主屏幕上，按测试设置面板（请参阅下图）。</span></strong></p>
<p><strong><span style="color: #800000;"> </span></strong>2-2 在更改测试屏幕，按编辑。2-3 在测试设置屏幕上，按各面板以更改相应设置：? 测试类型：选择自动<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>。? 前导补偿：如果您将使用前导/末尾线，将此设置为开。? 波长：选择测试波长。? 光纤类型：在光纤类型屏幕，选择适用的光纤类型。要查看其他光纤类型组，按一下更多，然后按一个组。? 测试限制：为此项作业选择正确的限制。要查看其他限制组，按更多，然后按组名。2-4 要保存设置，在测试设置屏幕上按保存。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/01/optifiber-test.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5656" title="福禄克optifiber测试界面" src="http://www.faxytech.com/wp-content/uploads/2015/01/optifiber-test.jpg" alt="" /></a></p>
<p>A 要建立一个项目，按项目面板。B 要更改测试设置，或选择另一项测试，按测试设置面板。C 要设置线缆ID，打开自动保存，然后更改光纤终端设置，按下一个ID面板。D 要输入操作者姓名，按操作者面板。</p>
<p><strong><span style="color: #800000;">3. 前导和末尾线补偿（推荐）利用前导和末尾线。</span></strong></p>
<p><strong><span style="color: #800000;"> </span></strong>Fluke OptiFiber PRO(OFP-100-M,OFP-100-S,OFP-100-Q)测试仪可测量布线中首个连接器和最后一个连接器的损耗和反射，并在整体损耗测量中包含这些结果。如果没有前导和末尾线，则在首个连接器之前或最后一个连接器之后均无法探测到背向散射。因此，<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span>建议您使用前导和末尾线。此外，应该使用前导/末尾线补偿功能，以便从OTDR测量中减去这些光纤的长度。对前导和末尾线进行补偿</p>
<p>3-1 选择与将测试的光纤类型相同的前导和末尾线。<br />
3-2 在主屏幕，按工具，然后按设置前导补偿。<br />
3-3 在设置前导方式屏幕，按前导 + 末尾。<br />
3-4 清洁并检查OTDR端口和前导/末尾线连接器。<br />
3-5 按图3所示进行连接。<br />
3-6 按设置。<br />
3-7 当出现设置前导补偿屏幕时，选择前导线终端及末尾线起始端事件（如果此事件尚未选择）。<br />
3-8 按保存。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/01/ofp-100-q.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5657" title="福禄克FLuke ofp-100-q光纤测试仪" src="http://www.faxytech.com/wp-content/uploads/2015/01/ofp-100-q.jpg" alt="" width="586" height="270" /></a></p>
<p><strong><span style="color: #800000;">4. 执行OTDR测试</span></strong></p>
<p>4-1 清洁并检查前导和末尾线以及要测试的光纤上的连接器。4-2 如图4所示，将测试仪连接到链路中。4-3 按测试或按B。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/01/otdr-test.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5658" title="福禄克OTDR测试" src="http://www.faxytech.com/wp-content/uploads/2015/01/otdr-test.jpg" alt="" width="584" height="282" /></a></p>
<p><strong><span style="color: #800000;">5. 查看结果</span></strong></p>
<p>福禄克OptiFiber PRO测试仪以三种格式显示OTDR结果（图5）：</p>
<p>? EventMap：将光纤的事件、光纤长度和光纤的整体损耗以事件图形式显示。利用此屏幕可快速对光纤上的连接器及故障进行定位。若要查看事件的详细信息，在图中按该事件，然后按该事件的信息窗口。</p>
<p>? 表格：将光纤的事件以表格形式显示。利用此屏幕可迅速查看所有事件的测量结果，并可查看光纤的事件类型。此表格中包括事件的距离、事件的损耗、事件反射的大小以及事件的类型等。要查看事件的详细信息，在表格中按该事件。</p>
<p>?曲线：显示OTDR曲线。利用此屏幕可查看反射事件的死区、检查意外事件的特征（如幻影和增益器等）。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/01/OptiFiber-report.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5659" title="福禄克OptiFiber PRO光纤测试仪" src="http://www.faxytech.com/wp-content/uploads/2015/01/OptiFiber-report.jpg" alt="福禄克OptiFiber PRO光纤测试仪" width="582" height="293" /></a></p>
<p><span style="color: #800000;"><strong>6. 保存结果</strong></span></p>
<p>6-1 如果通过OFP-100-Q或者OFP-100-M，OFP-100-S测试，按保存；如果测试失败，按稍后修复。6-2 如果电缆ID框显示正确的ID，按保存。要输入电缆ID，按保存结果屏幕上的电缆ID框，使用键盘输入果的名称，按完成，然后按保存。如果不选择其他项目，测试仪将把结果保存在默认项目中。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/optifiber-test.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【福禄克】Fluke OFP-100-M多模OTDR测试仪OptiFiber PRO</title>
		<link>http://www.faxytech.com/archives/ofp-100-m.html</link>
		<comments>http://www.faxytech.com/archives/ofp-100-m.html#comments</comments>
		<pubDate>Mon, 29 Sep 2014 06:33:11 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[福禄克光缆测试产品]]></category>
		<category><![CDATA[OFP-100-M]]></category>
		<category><![CDATA[OptiFiber Pro]]></category>
		<category><![CDATA[OTDR]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=5095</guid>
		<description><![CDATA[深圳市连讯达电子技术开发有限公司专业销售福禄克Fluke OFP-100-M多模OTDR测试仪。 福禄克Fluke OFP-100-M标准配置清单及图片： OptiFiber Pro Multimode OTDR 套件。套件中包含带 MM OTDR 模块的 OptiFiber Pro、... ]]></description>
			<content:encoded><![CDATA[<p>深圳市连讯达电子技术开发有限公司专业销售福禄克Fluke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-m.html" title="fluke OFP-100-M">OFP-100-M</a></span>多模<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>测试仪。</p>
<p>福禄克Fluke <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-m" title="查看 OFP-100-M 的全部文章" target="_blank">OFP-100-M</a></span>标准配置清单及图片：</p>
<p><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> Pro Multimode <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/otdr" title="查看 OTDR 的全部文章" target="_blank">OTDR</a></span> 套件。套件中包含带 MM OTDR 模块的 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-optifiber-pro-otdr.html" title="福禄克Fluke OptiFiber Pro">OptiFiber Pro</a></span>、便携带、交流适配器/充电器、USB 接口电缆 – 标准 A &#8211; micro B，用户指南 CD、<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span> 软件 CD、入门指南、<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>说明、注册卡、厂家保修和便携箱。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/ofp-100-m.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5096" title="福禄克Fluke ofp-100-m 多模OTDR测试仪" src="http://www.faxytech.com/wp-content/uploads/2014/09/ofp-100-m.jpg" alt="福禄克Fluke ofp-100-m 多模OTDR测试仪" width="538" height="466" /></a></p>
<p>&nbsp;</p>
<p title="OptiFiber&lt;sup&gt;?&lt;/sup&gt; Pro OTDR">OptiFiber<span style="font-size: 12px;"> </span> Pro OTDR专为企业打造</p>
<p>OFP-100-M 是为企业光纤布线测试从头打造的 OTDR 产品系列。OptiFiber?Pro 不但可以节约成本，同时可以提高生产率以及改进网络可靠性。</p>
<ul>
<li>首创智能手机界面的 OTDR</li>
<li>业界最短事件和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>死区</li>
<li>以最快速的设定和追踪时间加速光纤验证</li>
<li>SmartLoop OTDR 可在一次测试中进行双光纤测试，无需移至接线的远端进行测试。</li>
<li>通过项目和用户的自定义配置提高资源利用率</li>
<li>通过“DataCenter OTDR?”模式和 EventMap? 视图简化使用方式</li>
<li>自定义项目文件夹</li>
</ul>
<p style="text-align: center;"><embed type="application/x-shockwave-flash" width="480" height="400" src="http://player.youku.com/player.php/sid/XNzkzMjQwMTQ4/v.swf" allowscriptaccess="always" align="middle" quality="high" allowfullscreen="true"></embed></p>
<p style="text-align: center;">福禄克OFP-100-M视频演示</p>
<p>福禄克Fluke OFP-100-M?是专为企业光纤设施设计的全新型 OTDR。此故障排除及验证工具不但功能强大、效率极高，而且包含有对校园网、数据中心以及存储光纤网络进行故障排除全部所需功能。</p>
<p>OptiFiber ?Pro OTDR 通过业界唯一的智能手机界面提高了光纤测试的高度，让每一名技师都成为光纤专家。DataCenter OTDR 配置可减少对数据中心光纤进行测试时所发生的不确定性和错误。其超短的死区允许在虚拟数据中心进行光纤跳线测试。这些功能以及业界最快的扫描时间，使 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/optifiber-pro" title="查看 OptiFiber Pro 的全部文章" target="_blank">OptiFiber Pro</a></span> OTDR 成为您的必备工具。</p>
<h4>福禄克Fluke?OFP-100-M多模<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>OTDR智能手机用户界面</h4>
<p>大多数 OTDR 都需要应付大量复杂情况，使用户界面难以浏览和阅读。OptiFiber Pro 结合最新的“手势”界面技术和电容触摸屏为您提供了最新的用户友好 OTDR。</p>
<div id="11614a">
<p>优势：</p>
<ul>
<li>使用单击和重击来选择和滚动菜单项</li>
<li>多点触摸收缩可方便地调整光纤曲线的显示比例</li>
<li>以任务为中心的设备可减少前后屏的翻动次数</li>
<li>电容触摸屏不像传统触摸屏幕那样需要校准</li>
<li>根据环境显示的屏幕帮助可为用户提供更多信息或问题解决建议</li>
</ul>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/Smartphone-User-Interface-Feature.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5097" title="福禄克OFP-100-M智能界面" src="http://www.faxytech.com/wp-content/uploads/2014/09/Smartphone-User-Interface-Feature.jpg" alt="福禄克OFP-100-M智能界面" width="554" height="347" /></a></p>
</div>
<h4>福禄克Fluke?OFP-100-M多模OTDR光纤测试仪<span style="font-weight: normal;">为数据中心优化</span></h4>
<p>根据服务器虚拟化和服务器、网络存储之间的多兆连接的发展需求，数据中心架构采用了更多跳接线和密集拓扑连接器，使有长死区的电信级 OTDR 无效。OptiFiber Pro 不仅使在数据中心部署光纤成为可能，更提供了最准确的的迅速解决问题的解决方案。</p>
<p>只需简单的一键选择，用户即可进入 DataCenter OTDR 模式 &#8211; 无需再进行 OTDR 的设置。DataCenter OTDR 模式自动检测 OTDR 参数 &#8211; 端点检测算法，脉冲宽度等 &#8211; 而不会被短连接或连接器的数量干扰。</p>
<p>优势：</p>
<ul>
<li>超短事件和衰减死区可精确地定位事件和光纤连接中的故障</li>
<li>DataCenter OTDR? 模式自动配置并迅速测试数据中心光纤</li>
<li>EventMap 功能以无需扫描分析专业知识即可看懂的方式说明光纤事件</li>
</ul>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/OTDR-Setup.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5098" title="福禄克Fluke OFP-100-M设置界面" src="http://www.faxytech.com/wp-content/uploads/2014/09/OTDR-Setup.jpg" alt="福禄克Fluke OFP-100-M设置界面" width="554" height="347" /></a></p>
<p>&nbsp;</p>
<h4>福禄克Fluke?OFP-100-M多模OTDR光纤测试仪?SmartLoop OTDR</h4>
<p>SmartLoop OTDR 可进行自动化测试并对一次测试中的两条光纤进行分析。此套专利申请流程可自动根据单独通过/失败分析、显示和报告将两条光纤分离。它不仅可将测试时间至少减半，还能够在无需将 OTDR 移至远端点的情况下进行双向测试。SmartLoop OTDR 不仅可使作业完成更加快速，由于 OTDR 无需移至远端点，所以还能够在很难到达远端点甚至是危险的环境下进一步增强测试的容易度及速度。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/Smartloop_using_demo_artifact_new.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5099" title="Smartloop_using_demo_artifact_new" src="http://www.faxytech.com/wp-content/uploads/2014/09/Smartloop_using_demo_artifact_new.jpg" alt="" width="307" height="410" /></a></p>
<p style="text-align: center;">&nbsp;</p>
<h4>福禄克Fluke?OFP-100-M多模OTDR光纤测试仪灵活而有效的独特认证</h4>
<p>合理安排日常使用对最大化 OTDR 的价值有重要意义。项目经理可通过 OptiFiber Pro 内置的项目管理定义各用户的角色、设置和关联要执行的任务 – 使 OTDR 成为可计划、检查、认证和报告的万能光纤测试工具。</p>
<p>OptiFiber Pro 允许工作流程计划人员根据项目创建和管理操作员和工作配置 &#8211; 定义的工作或电缆 ID 可分配给特定操作员，从而提高了工作效率。您还可方便地查看各项目的进展和状态。</p>
<p>优势：</p>
<ul>
<li>全面的 OTDR 功能可根据各操作员的工作分配保证光纤性能。</li>
<li>强大的项目管理功能可清晰地为操作员分配任务以促进 OTDR 共享</li>
<li>利用完成/失败结果可方便地监控工作进展</li>
<li>屏幕帮助可帮助您生成报告并上传到 LinkWare? 应用程序</li>
</ul>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/Dynamic-project.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5100" title="福禄克FLuke OFP-100-M OptiFiber pro OTDR测试仪" src="http://www.faxytech.com/wp-content/uploads/2014/09/Dynamic-project.jpg" alt="福禄克FLuke OFP-100-M OptiFiber pro OTDR测试仪" width="337" height="439" /></a></p>
<p>&nbsp;</p>
<h4>福禄克Fluke?OFP-100-M多模OTDR光纤测试仪<span style="font-weight: normal;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fiberinspector-mini.html" title="FiberInspector 袖珍光纤视频显微镜">FiberInspector</a></span>? Pro</span></h4>
<p>OptiFiber Pro 整合了 FiberInspector Pro 视频检查系统，藉此您可对端口或跳线内的光纤端面进行快速检查和确认。通过 2 秒自动化通过/失败 IEC 61300-3-35 认证，可消除人为主观因素并可使每个人变成光纤检测专家。其结果将与 OptiFiber Pro 的 OTDR 结果一同保存于认证报告中。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/FiberInspector-Pro.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5101" title="FiberInspector Pro FI7000" src="http://www.faxytech.com/wp-content/uploads/2014/09/FiberInspector-Pro.jpg" alt="FiberInspector Pro FI7000" width="307" height="410" /></a></p>
<p>&nbsp;</p>
<h4>福禄克Fluke?OFP-100-M多模OTDR光纤测试仪其他主要特点：</h4>
<p><strong>超短事件和衰减死区 </strong><br />
OptiFiber Pro 利用最成熟的光学技术为所有 OTDR 提供最短事件死区（MM 通常为 0.5 m）和衰减死区（MM 通常为 2.2 m，SM 通常 为 3.6 m）。这种技术优势使 OptiFiber Pro 能够检测超近距离故障，而这是目前富连接器数据中心和数据存储环境中的其它 OTDR 无法做到的。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/Short-Attenuation-Zones.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5102" title="Short Attenuation Zones" src="http://www.faxytech.com/wp-content/uploads/2014/09/Short-Attenuation-Zones.jpg" alt="" width="326" height="446" /></a></p>
<p><strong>LinkWare? management software</strong><br />
利用流行的 LinkWare 电缆测试管理软件应用程序，OptiFiber Pro 用户可简单方便地管理项目、制作报告并升级软件以管理工作流程和整理测试结果。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/LinkWare-management-software.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5103" title="福禄克LinkWare数据管理软件" src="http://www.faxytech.com/wp-content/uploads/2014/09/LinkWare-management-software.jpg" alt="福禄克LinkWare数据管理软件" width="538" height="378" /></a></p>
<p><strong>每波长两秒扫描 </strong><br />
OptiFiber Pro 的划时代意义在于其采集速度。在“快速测试”模式下，每波长只需短短两秒即可采集到一套完整数据。OptiFiber Pro 然后分析数据并将其作为 EventMap、Table 或 Trace 显示出来。最终结果是使用了更少的时间，从而可将更多时间用到其它工作上。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/Test-in-progress.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5104" title="福禄克OFP-100-M测试界面" src="http://www.faxytech.com/wp-content/uploads/2014/09/Test-in-progress.jpg" alt="福禄克OFP-100-M测试界面" width="554" height="347" /></a></p>
<p><strong>屏幕帮助 – 修正措施 </strong><br />
屏幕“帮助”可在各测试步骤中显示用于解决光纤问题的修正措施建议。这些“帮助”是与环境相关的，使用户能够迅速找到可能的解决方案。左下角灰色图标中清晰地显示了详细的修正措施建议。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/Help-Screen.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5105" title="福禄克Fluke OFP-100-M帮助界面" src="http://www.faxytech.com/wp-content/uploads/2014/09/Help-Screen.jpg" alt="福禄克Fluke OFP-100-M帮助界面" width="554" height="347" /></a></p>
<p>&nbsp;</p>
<h4>福禄克Fluke?OFP-100-M多模OTDR光纤测试仪<strong>OTDR 主要技术指标</strong></h4>
<table id="SpecTable0" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td></td>
<td><strong>Multimode 模块</strong></td>
<td><strong>Singlemode 模块</strong></td>
<td><strong>Quad 模块</strong></td>
</tr>
<tr>
<td><strong>波长</strong></td>
<td>850 nm +/- 10 nm<br />
1300 nm +35/-15 nm</td>
<td>1310 nm +/- 25 nm<br />
1550 nm +/- 30 nm</td>
<td>850 nm +/- 10 nm<br />
1300 nm +35/-15 nm<br />
1310 nm +/- 25 nm<br />
1550 nm +/- 30 nm</td>
</tr>
<tr>
<td><strong>兼容光纤类型</strong></td>
<td>50/125 ?m<br />
62.5/125 ?m</td>
<td>单模</td>
<td>50/125 ?m<br />
62.5/125 ?m<br />
单模</td>
</tr>
<tr>
<td><strong>事件死区 1</strong></td>
<td>850 nm ：0.5 m（典型）<br />
1300 nm ：0.7 m（典型）</td>
<td>1310 nm ：0.6 m（典型）<br />
1550 nm ：0.6 m（典型）</td>
<td>850 nm ：0.5 m（典型）<br />
1300 nm ：0.7 m（典型）<br />
1310 nm ：0.6 m（典型）<br />
1550 nm ：0.6 m（典型）</td>
</tr>
<tr>
<td><strong>衰减死区 2</strong></td>
<td>850 nm ：2.5 m（典型）<br />
1300 nm ：4.5 m（典型）</td>
<td>1310 nm ：3.6 m（典型）<br />
1550 nm ：3.7 m（典型）</td>
<td>850 nm ：2.5 m（典型）<br />
1300 nm ：4.5 m（典型）<br />
1310 nm ：3.6 m（典型）<br />
1550 nm ：3.7 m（典型）</td>
</tr>
<tr>
<td><strong>动态范围3，5，6</strong></td>
<td>850 nm ：一般为 28 dB<br />
1300 nm ：一般为 30 dB</td>
<td>1310 nm ：一般为 32 dB<br />
1550 nm ：一般为 30 dB</td>
<td>850 nm ：一般为 28 dB<br />
1300 nm ：一般为 30 dB<br />
1310 nm ：一般为 32 dB<br />
1550 nm ：一般为 30 dB</td>
</tr>
<tr>
<td><strong>最大距离范围设置</strong></td>
<td>40 km</td>
<td>130 km</td>
<td>MM：40 km<br />
SM：130 km</td>
</tr>
<tr>
<td><strong>距离测量范围 4，5，7，8，9，10</strong></td>
<td>850 nm ：9 km<br />
1300 nm ：35 km</td>
<td>1310 nm ：80 km<br />
1550 nm ：130 km</td>
<td>850 nm ：9 km<br />
1300 nm ：35 km<br />
1310 nm ：80 km<br />
1550 nm ：130 km</td>
</tr>
<tr>
<td><strong>反射范围 4，5</strong></td>
<td>850 nm ：一般为 -14 dB 至 -57 dB<br />
1300 nm ：一般为 -14 dB 至 -62 dB</td>
<td>1310 nm ：一般为 -14 dB 至 -65 dB<br />
1550 nm ：一般为 -14 dB 至 -65 dB</td>
<td>850 nm ：一般为 -14 dB 至 -57 dB<br />
1300 nm ：一般为 -14 dB 至 -62 dB<br />
1310 nm ：一般为 -14 dB 至 -65dB<br />
1550 nm ：一般为 -14 dB 至 -65 dB</td>
</tr>
<tr>
<td><strong>采样分辨率</strong></td>
<td>3 cm 至 400 cm</td>
<td>3 cm 至 400 cm</td>
<td>3 cm 至 400 cm</td>
</tr>
<tr>
<td><strong>脉冲宽度（额定）</strong></td>
<td>850 nm ：3, 5, 20, 40, 200 ns<br />
1300 nm ：3, 5, 20, 40, 200, 1000 ns</td>
<td>1310/1550 nm：3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns</td>
<td>850 nm ：3, 5, 20, 40, 200 ns<br />
1300 nm ：3, 5, 20, 40, 200, 1000 ns<br />
1310/1550 nm：3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns</td>
</tr>
<tr>
<td rowspan="6"><strong>测试时间（每波长）</strong></td>
<td>自动设置：一般为 5 秒</td>
<td>自动设置：一般为 10 秒</td>
<td>自动设置：<br />
MM – 一般为 5 秒<br />
SM – 一般为 10 秒</td>
</tr>
<tr>
<td>快速测试设置：<br />
一般为 2 秒</td>
<td>快速测试设置：<br />
一般为 5 秒</td>
<td>快速测试设置：<br />
MM – 一般为 2 秒<br />
SM – 一般为 5 秒</td>
</tr>
<tr>
<td>最佳分辨率设置：<br />
2 到 180 秒</td>
<td>最佳分辨率设置：<br />
5 到 180 秒</td>
<td>最佳分辨率设置：<br />
MM – 2 到 180 秒 M<br />
SM – 5 到 180 秒</td>
</tr>
<tr>
<td>FaultMap 设置：<br />
2 秒（一般），180 秒（最大）</td>
<td>FaultMap 设置：<br />
10 秒（一般），180 秒（最大）</td>
<td>FaultMap 设置：<br />
MM &#8211; 2 秒（一般），MM &#8211; 180 秒（最大）<br />
SM &#8211; 10 秒（一般），SM &#8211; 180 秒（最大）</td>
</tr>
<tr>
<td>DataCenter OTDR 设置：<br />
1 秒（一般在 850 nm），7 秒（最大）</td>
<td>DataCenter OTDR 设置：<br />
20 秒（一般），40 秒（最大）</td>
<td>DataCenter OTDR 设置：<br />
MM – 1 秒（一般在 850 nm） MM – 7 秒（最大）<br />
SM – 20 秒（一般） SM – 40 秒（最大）</td>
</tr>
<tr>
<td>手动设置：<br />
3，5，10，20，40，60，90，120，180 秒</td>
<td>手动设置：<br />
3，5，10，20，40，60，90，120，180 秒</td>
<td>手动设置：<br />
-3，5，10，20，40，60，90，120，180 秒 SM &#8211; 3，5，10，20，40，60，90，120，180 秒</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<ol>
<li>在低于最短脉冲宽度非饱和反射峰和 1.5 dB 之下测量。反射峰多模 &lt; -40 dB，单模 &lt; &#8211; 50 dB。</li>
<li>在偏离最短脉冲宽度反向散射 +/- 0.5 dB 处测量。反射峰多模 &lt; -40 dB，单模 &lt; &#8211; 50 dB。</li>
<li>对于 OM1 光纤典型的反向散射系数：850:-65 dB, 1300:-72 dB.</li>
<li>OM2-OM4 光纤的典型反向散射和衰减系数：850 nm ：-68 dB; 2.3 dB/km:1300 nm ：-76 dB; 0.6 dB/km.</li>
<li>OM1-OM2 光纤的典型反向散射和衰减系数：1310nm/1550nm ：-79 dB; 0.32 dB/km; 1550 nm:-82 dB; 0.19 dB/km.</li>
<li>SNR=1 方法，3 分钟平均，最大脉冲宽度。</li>
<li>通常在 850 = 9 km 发现端点或通常在 7 km 发现 0.1 dB 事件（事件之前最大 18 dB 衰减）。</li>
<li>通常在 1300 = 35 km 发现端点或通常在 30 km 发现 0.1 dB 事件（事件之前最大 18 dB 衰减）。</li>
<li>通常在 1310 = 80 km 发现端点或通常在 60km 发现 0.1 dB 事件（事件之前最大 20 dB 衰减）。</li>
<li>通常在 1550 = 130 km 发现端点或通常在 90 km 发现 0.1 dB 事件（事件之前最大 18 dB 衰减）。</li>
<li>不包括折射率系数错误，也不包括自动事件位置错误。</li>
<li>dB 变化/1 dB 阶跃。</li>
<li>应用于在 OTDR 可找到一个 0.1 dB 事件的距离范围内的轨迹反向散射。</li>
</ol>
<p>&nbsp;</p>
<p><strong>其它主要技术指标</strong></p>
<table id="SpecTable1" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td colspan="2">FiberInspector 探头技术指标</td>
</tr>
<tr>
<td>放大倍率</td>
<td>~ 200X 带 OptiFiber Pro 显示</td>
</tr>
<tr>
<td>光源</td>
<td>蓝色 LED</td>
</tr>
<tr>
<td>电源</td>
<td><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> 主机</td>
</tr>
<tr>
<td>视野 (FOV)</td>
<td>水平：425 ?m<br />
垂直：320 ?m</td>
</tr>
<tr>
<td>最小可检测微粒大小</td>
<td>0.5 ?m</td>
</tr>
<tr>
<td>体积</td>
<td>大约 6.75 英寸 x 1.5 英寸（1175 毫米 x 35 毫米），无适配器端头</td>
</tr>
<tr>
<td>重量</td>
<td>200 g</td>
</tr>
<tr>
<td><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>范围</td>
<td>工作时：32°F 至 122°F (0 °C 到 +50 °C)<br />
存放：-4°F 至 +158°F（-20°C 至 +70°C）</td>
</tr>
<tr>
<td>合格证</td>
<td>CE（使用主机时）</td>
</tr>
</tbody>
</table>
<table id="SpecTable2" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td colspan="2">VFL 技术指标</td>
</tr>
<tr>
<td>开关控制</td>
<td>机械开关和触摸屏幕上的按钮</td>
</tr>
<tr>
<td>输出功率</td>
<td>316 μW (-5 dBm) = 峰值功率 = 1.0 mW (0 dBm)</td>
</tr>
<tr>
<td>工作波长</td>
<td>650 nm 额定</td>
</tr>
<tr>
<td>谱宽 (RMS)</td>
<td>±3 nm</td>
</tr>
<tr>
<td>输出模式</td>
<td>连续波和脉冲模式（2 Hz &#8211; 3 Hz 闪烁频率）</td>
</tr>
<tr>
<td>接头适配器</td>
<td>2.5 mm 通用</td>
</tr>
<tr>
<td>激光安全性（类别）</td>
<td>II 类 CDRH 符合 EN 60825-2</td>
</tr>
</tbody>
</table>
<table id="SpecTable3" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td colspan="2">一般规格</td>
</tr>
<tr>
<td>重量</td>
<td>带模块和电池的主机：3 磅，5 盎司（1.28 千克）</td>
</tr>
<tr>
<td>体积</td>
<td>带模块和电池的主机：2.625 英寸 x 5.25 英寸 x 11.0 英寸（6.67 厘米 x 13.33 厘米 x27.94 厘米）</td>
</tr>
<tr>
<td>电池</td>
<td>锂离子电池组，7.2 V</td>
</tr>
<tr>
<td>电池寿命</td>
<td>八小时自动 OTDR 运行，双波长，无视频探头连接，150 m 光纤</td>
</tr>
<tr>
<td><strong>充电时间</strong></td>
<td></td>
</tr>
<tr>
<td>测试仪关</td>
<td>电量从 10% 充到 90% 需四小时</td>
</tr>
<tr>
<td>测试仪开</td>
<td>测试仪开启时电量从 10% 充到 90% 需要六小时</td>
</tr>
</tbody>
</table>
<table id="SpecTable4" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td colspan="2">环境技术指标</td>
</tr>
<tr>
<td>工作温度*</td>
<td>-18?C 至 45?C</td>
</tr>
<tr>
<td>非操作温度</td>
<td>-30?C 至 60?C</td>
</tr>
<tr>
<td>操作高度</td>
<td>4,000 m (13123 ft)<br />
3200 米（10,500 英尺）带交流适配器</td>
</tr>
<tr>
<td>存储高度</td>
<td>12,000 米</td>
</tr>
<tr>
<td>EMC</td>
<td>EN 61326-1</td>
</tr>
</tbody>
</table>
<p>* 使用电池供电。带 AC 适配器：0?C 至 45?C。每 15 分钟时间段时实时扫描功能不能使用超过 5 分钟。使用实时扫描功能的最高环境温度为 35?C。<br />
* 请不要将电池保存于低于 -20°C (-4°F) 或高于 50°C (122°F) 的环境下超过一个星期，以免损坏电池容量。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/ofp-100-m.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FLuke OptiFiber PRO设置补偿光纤有什么好处？</title>
		<link>http://www.faxytech.com/archives/optifiber-pro-bc.html</link>
		<comments>http://www.faxytech.com/archives/optifiber-pro-bc.html#comments</comments>
		<pubDate>Thu, 24 Apr 2014 05:53:07 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[OFP-100-M]]></category>
		<category><![CDATA[OFP-100-Q]]></category>
		<category><![CDATA[OFP-100-S]]></category>
		<category><![CDATA[OptiFiber Pro]]></category>
		<category><![CDATA[前导光纤]]></category>
		<category><![CDATA[末尾线]]></category>
		<category><![CDATA[补偿光纤]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=3780</guid>
		<description><![CDATA[FLuke OptiFiber PRO设置补偿光纤有什么好处？福禄克OptiFiber PRO OTDR光纤测试仪在设置里面有设置补偿光纤选项，那它是什么意思呢？为什么要设置补偿光纤？ 因为利用前导和末尾补偿线，OFP-100-Q或... ]]></description>
			<content:encoded><![CDATA[<p>FLuke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> PRO设置<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%a1%a5%e5%81%bf%e5%85%89%e7%ba%a4" title="查看 补偿光纤 的全部文章" target="_blank">补偿光纤</a></span>有什么好处？福禄克OptiFiber PRO <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>在设置里面有设置补偿光纤选项，那它是什么意思呢？为什么要设置补偿光纤？</p>
<p>因为利用前导和末尾补偿线，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span>或者其他OptiFiber PRO系列测试仪可测量布线中首个连接器和最后一个连接器的损耗和反射，并在整体损耗测量中包含这些结果。如果OptiFiber PRO没有前导和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%9c%ab%e5%b0%be%e7%ba%bf" title="查看 末尾线 的全部文章" target="_blank">末尾线</a></span>，则在首个连接器之前或最后一个连接器之后均无法探测到反向散射。要测量连接器的属性，福禄克<span style="font-size: 12.727272033691406px;">OptiFiber PRO</span>测试仪必须在该连接器前后分别测量反向散射。</p>
<p>因此，深圳连讯达公司建议您使用前导和末尾线。此外，应该使用前导/末尾线补偿功能，以便从OTDR测量中减去这些光纤的长度。如果选择的测试限制要求使用前导和末尾线，那么当您试图在无前导和末尾线的情况下执行OTDR测试时，福禄克FLuke OptiFiber PRO测试仪会显示一个警告消息。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/optifiber-pro-bc.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克FLUKE DTX-OTDR 与OptiFiber PRO的区别？</title>
		<link>http://www.faxytech.com/archives/dtx-otdr-optifiber-different.html</link>
		<comments>http://www.faxytech.com/archives/dtx-otdr-optifiber-different.html#comments</comments>
		<pubDate>Fri, 15 Nov 2013 01:21:46 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[dtx-otdr]]></category>
		<category><![CDATA[DTX-OTDR 与OptiFiber PRO的区别]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[ftk1000]]></category>
		<category><![CDATA[ftk1450]]></category>
		<category><![CDATA[FTK2000]]></category>
		<category><![CDATA[OFP-100-M]]></category>
		<category><![CDATA[OFP-100-Q]]></category>
		<category><![CDATA[OFP-100-S]]></category>
		<category><![CDATA[OptiFiber Pro]]></category>
		<category><![CDATA[simplifiber pro]]></category>
		<category><![CDATA[事件死区]]></category>
		<category><![CDATA[动态范围]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[距离范围]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=3371</guid>
		<description><![CDATA[许多同学经常会问的一个问题就是：福禄克FLUKE DTX-OTDR 与OptiFiber PRO的区别？ 我们在给客户选型的时候，经常会推荐光纤测试仪。客户开始只会说一个问题，我需要测试光纤，这时候，我们需要... ]]></description>
			<content:encoded><![CDATA[<p>
	许多同学经常会问的一个问题就是：<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>FLUKE <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="福禄克FLUKE DTX-OTDR测试仪">DTX-OTDR</a></span> 与<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> PRO的区别？
</p>
<p>
	我们在给客户选型的时候，经常会推荐<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>。客户开始只会说一个问题，我需要测试光纤，这时候，我们需要引导他如何回答。
</p>
<p>
	具体如何引导呢？
</p>
<p>
	<strong>1：您是要测试单模还是多模光纤？</strong>
</p>
<p>
	<span style="color:#FF0000;">分析：</span>因为福禄克网络（FLuke Networks）的产品或者其他品牌都会有单多模之分。
</p>
<p>
	<strong>2：您是只需要测试光纤<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>，还是长度和衰减，还是要测试<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>？</strong>
</p>
<p>
	<span style="color:#FF0000;">分析：</span>如果只是衰减那我们只需要选择<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/simplifiber-pro.html" title="福禄克FLUKE SimpliFiber Pro光纤测试仪">SimpliFiber</a></span> PRO系列就可以了，单模就是<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/simplifiber-pro.html" title="福禄克Fluke FTK2000">FTK2000</a></span>，多模<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/simplifiber-pro.html" title="福禄克FLUKE SimpliFiber Pro光纤测试仪">FTK1000</a></span>，如果单多模都需要测试那可以推荐<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ftk1450.html" title="福禄克FLUKE FTK1450">FTK1450</a></span>。<span style="line-height: 1.6em;">如果长度和衰减都要测试可以推荐<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-xfm2.html" title="DTX系列分析仪仪光纤测试模块">DTX-MFM2</a></span> 和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-xfm2.html" title="DTX系列光缆测试模块">DTX-SFM2</a></span>，OTDR可以推荐<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-OTDR模块（注意：必须搭配<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-lt.html" title="福禄克FLUKE DTX-LT测试仪">DTX-LT</a></span>使用），如果需要测试OTDR，即长度，衰减，故障点距离，那么就是OTDR了。</span>
</p>
<p>
	经过上述问题，现在回到我们今天谈论的话题了。
</p>
<p>
	<strong>那福禄克FLUKE的OTDR不是两种吗？<span style="font-size: 13px;">福禄克FLUKE DTX-OTDR 与OptiFiber PRO，那他们有什么区别呢？</span></strong>
</p>
<p>
	<span style="color:#FF0000;"><span style="font-size: 13px;">分析： &nbsp;</span></span>
</p>
<p>
	1：从外观上看，DTX-OTDR只是一个模块，必须配合DTX-1800或者其他DTX系列仪器使用，OptiFiber PRO它本身就是一个单独可以测试的仪器。
</p>
<p>
	2：<span style="font-size: 13px;">福禄克FLUKE DTX-OTDR 与OptiFiber PRO</span>从<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e4%ba%8b%e4%bb%b6%e6%ad%bb%e5%8c%ba" title="查看 事件死区 的全部文章" target="_blank">事件死区</a></span>和衰减死区看区别：
</p>
<p>
	1）福禄克FLUKE OptiFiber PRO的事件死区和衰减死区：
</p>
<table border="0" bordercolor="black" cellpadding="0" cellspacing="0" id="SpecTable0" style="font-family: Tahoma, Helvetica, Arial, sans-serif; line-height: 22px; background-color: rgb(240, 245, 248);" width="100%">
<tbody>
<tr>
<td>
				<strong>事件死区 1</strong>
			</td>
<td>
				<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-m.html" title="fluke OFP-100-M">OFP-100-M</a></span><br />
				850 nm ：<span style="color:#B22222;"> 0.5 m（典型）</span><br />
				1300 nm ：<span style="color:#B22222;"> </span><span style="color:#B22222;">0.7 m（典型）</span>
			</td>
<td>
				<span style="font-family: Tahoma, Helvetica, Arial, sans-serif; font-size: 13px; line-height: 22px; background-color: rgb(240, 245, 248);"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-s.html" title="福禄克Fluke OFP-100-S">OFP-100-S</a></span></span><br />
				1310 nm ：<span style="color:#B22222;"> 0.6 m（典型）</span><br />
				1550 nm ：<span style="color:#B22222;"> 0.6 m（典型</span>）
			</td>
<td>
				850 nm ： 0.5 m（典型）<span style="font-family: Tahoma, Helvetica, Arial, sans-serif; font-size: 13px; line-height: 22px; background-color: rgb(240, 245, 248);"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span></span><br />
				1300 nm ： 0.7 m（典型）<br />
				1310 nm ： 0.6 m（典型）<br />
				1550 nm ： 0.6 m（典型）
			</td>
</tr>
<tr>
<td>
				<strong>衰减死区 2</strong>
			</td>
<td>
				<span style="font-family: Tahoma, Helvetica, Arial, sans-serif; font-size: 13px; line-height: 22px; background-color: rgb(240, 245, 248);"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-m" title="查看 OFP-100-M 的全部文章" target="_blank">OFP-100-M</a></span></span><br />
				850 nm ： <span style="color:#B22222;">2.2 m（典型）</span><br />
				1300 nm ：<span style="color:#B22222;"> 4.5 m（典型）</span>
			</td>
<td>
				<span style="font-family: Tahoma, Helvetica, Arial, sans-serif; font-size: 13px; line-height: 22px; background-color: rgb(240, 245, 248);"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-s" title="查看 OFP-100-S 的全部文章" target="_blank">OFP-100-S</a></span></span><br />
				1310 nm ： <span style="color:#B22222;">3.6 m（典型）</span><br />
				1550 nm ： <span style="color:#B22222;">3.7 m（典型）</span>
			</td>
<td>
				850 nm ： 2.2 m（典型）<span style="font-family: Tahoma, Helvetica, Arial, sans-serif; font-size: 13px; line-height: 22px; background-color: rgb(240, 245, 248);"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-q" title="查看 OFP-100-Q 的全部文章" target="_blank">OFP-100-Q</a></span></span><br />
				1300 nm ： 4.5 m（典型）<br />
				1310 nm ： 3.6 m（典型）<br />
				1550 nm ： 3.7 m（典型）
			</td>
</tr>
</tbody>
</table>
<p>
	2）福禄克FLUKE DTX-OTDR的事件死区和衰减死区：
</p>
<table border="0" cellspacing="0" id="SpecTable2" style="font-family: Tahoma, Helvetica, Arial, sans-serif; line-height: 22px;">
<tbody>
<tr>
<td>
				<strong>事件死区<sup>*2</sup></strong>
			</td>
<td>
				850 nm ：<span style="color:#0000CD;">3.7m （典型</span>）, 1300 nm：<span style="color:#0000FF;">3.5 m（典型）</span>
			</td>
<td>
				1310 nm ：<span style="color:#0000FF;">3.5 m （典型）</span> 1550 nm：<span style="color:#0000FF;">3.5 m（典型）</span>
			</td>
</tr>
<tr>
<td>
				<strong>衰减死区<sup>*3</sup></strong>
			</td>
<td>
				850 nm ：<span style="color:#0000FF;">10 米</span>，1300 nm：<span style="color:#0000FF;">13米</span>
			</td>
<td>
				1310 nm ：<span style="color:#0000FF;">10 米</span>，1550 nm：<span style="color:#0000FF;">12米</span>
			</td>
</tr>
</tbody>
</table>
<p>
	3：<span style="font-size: 13px;">福禄克FLUKE DTX-OTDR 与OptiFiber PRO</span>从光纤测试距离上来看区别：
</p>
<p>
	<span style="font-size: 13px;">1）福禄克FLUKE OptiFiber PRO最大测试距离：</span>
</p>
<table border="0" bordercolor="black" cellpadding="0" cellspacing="0" id="SpecTable0" style="font-family: Tahoma, Helvetica, Arial, sans-serif; line-height: 22px; background-color: rgb(240, 245, 248);" width="100%">
<tbody>
<tr>
<td>
				<strong>最大<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%b7%9d%e7%a6%bb%e8%8c%83%e5%9b%b4" title="查看 距离范围 的全部文章" target="_blank">距离范围</a></span>设置</strong>
			</td>
<td>
				<strong><span style="color:#B22222;">40 km</span></strong>
			</td>
<td>
				<strong><span style="color:#B22222;">130 km</span></strong>
			</td>
<td>
				MM： 40 km（OFP-100-M）<br />
				SM： 130 km（OFP-100-S）
			</td>
</tr>
</tbody>
</table>
<p>
	2）<span style="font-size: 13px;">福禄克FLUKE DTX-OTDR的最大测试距离：</span>
</p>
<table border="0" cellspacing="0" id="SpecTable2" style="font-family: Tahoma, Helvetica, Arial, sans-serif; line-height: 22px;">
<tbody>
<tr>
<td>
				<strong>最大距离范围</strong>
			</td>
<td>
				850 nm ：<strong><span style="color:#B22222;">6 km</span></strong>，1300 nm：20 km
			</td>
<td>
				1310 nm ：20 km，1550 nm：<strong><span style="color:#B22222;">20 km</span></strong>
			</td>
</tr>
</tbody>
</table>
<p>
	4：
</p>
<p>
	<span style="font-size: 13px;">1）福禄克FLUKE OptiFiber PRO的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%8a%a8%e6%80%81%e8%8c%83%e5%9b%b4" title="查看 动态范围 的全部文章" target="_blank">动态范围</a></span>：</span>
</p>
<table border="0" bordercolor="black" cellpadding="0" cellspacing="0" id="SpecTable0" style="font-family: Tahoma, Helvetica, Arial, sans-serif; line-height: 22px; background-color: rgb(240, 245, 248);" width="100%">
<tbody>
<tr>
<td>
				<strong>动态范围</strong>
			</td>
<td>
				850 nm ： 一般为 28 dB<br />
				1300 nm ： 一般为 30 dB
			</td>
<td>
				1310 nm ： 一般为 32 dB<br />
				1550 nm ： 一般为 30 dB
			</td>
<td>
				850 nm ： 一般为 28 dB<br />
				1300 nm ： 一般为 30 dB<br />
				1310 nm ： 一般为 32 dB<br />
				1550 nm ： 一般为 30 dB
			</td>
</tr>
</tbody>
</table>
<p>
	2）<span style="font-size: 13px;">福禄克FLUKE DTX-OTDR的动态范围：</span>
</p>
<table border="0" cellspacing="0" id="SpecTable2" style="font-family: Tahoma, Helvetica, Arial, sans-serif; line-height: 22px;">
<tbody>
<tr>
<td>
				<strong>动态范围</strong>
			</td>
<td>
				850 nm ：24 dB，在 200ns 时, 1300 nm:26 dB，在 1 &micro;s 时
			</td>
<td>
				1310 nm ：26 dB，在 10 &micro;s 时，1550 nm:24 dB，在 10 &micro;s 时
			</td>
</tr>
</tbody>
</table>
<p>
	&nbsp;
</p>
<p>
	总结：从总体性能上OptiFiber PRO明显优于DTX-OTDR模块。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dtx-otdr-optifiber-different.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【福禄克】Fluke OptiFiber Pro OTDR光纤测试仪(OFP-100-M,OFP-100-S,OFP-100-Q)</title>
		<link>http://www.faxytech.com/archives/fluke-optifiber-pro-otdr.html</link>
		<comments>http://www.faxytech.com/archives/fluke-optifiber-pro-otdr.html#comments</comments>
		<pubDate>Tue, 27 Mar 2012 01:28:12 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[福禄克光缆测试产品]]></category>
		<category><![CDATA[OFP-100-M]]></category>
		<category><![CDATA[OFP-100-Q]]></category>
		<category><![CDATA[OFP-100-S]]></category>
		<category><![CDATA[OptiFiber]]></category>
		<category><![CDATA[OptiFiber Pro]]></category>
		<category><![CDATA[OTDR]]></category>
		<category><![CDATA[Versiv]]></category>
		<category><![CDATA[光纤测试仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=1979</guid>
		<description><![CDATA[福禄克Fluke OptiFiber?Pro (OFP-100-M,OFP-100-S)光纤测试仪是为企业光纤测试从头打造的 OTDR 产品系列。 OptiFiber?Pro 不但可以节约成本，同时可以提高生产率以及改进网络可靠性。 【福禄克】Fluke OptiFibe... ]]></description>
			<content:encoded><![CDATA[<p>福禄克Fluke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span>?Pro (<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-m.html" title="fluke OFP-100-M">OFP-100-M</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-s.html" title="福禄克Fluke OFP-100-S">OFP-100-S</a></span>)<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>是为企业光纤测试从头打造的 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span> 产品系列。 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/optifiber" title="查看 OptiFiber 的全部文章" target="_blank">OptiFiber</a></span>?Pro 不但可以节约成本，同时可以提高生产率以及改进网络可靠性。</p>
<h4>【福禄克】Fluke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-optifiber-pro-otdr.html" title="福禄克Fluke OptiFiber Pro">OptiFiber Pro</a></span> <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/otdr" title="查看 OTDR 的全部文章" target="_blank">OTDR</a></span>(<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-m" title="查看 OFP-100-M 的全部文章" target="_blank">OFP-100-M</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-s" title="查看 OFP-100-S 的全部文章" target="_blank">OFP-100-S</a></span>)概览：</h4>
<ul>
<li> 首创智能手机界面的 OTDR</li>
<li> 业界最短事件和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>死区</li>
<li> 以最快速的设定和追踪时间加速光纤验证</li>
<li> 通过项目和用户的自定义配置提高资源利用率</li>
<li> 通过“DataCenter OTDR?”模式和 EventMap? 视图简化使用方式</li>
<li> 自定义项目文件夹</li>
</ul>
<p>Fluke <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/optifiber-pro" title="查看 OptiFiber Pro 的全部文章" target="_blank">OptiFiber Pro</a></span> OTDR(OFP-100-M,OFP-100-S,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span>)实物图片：</p>
<p>OptiFiber? Pro 是专为企业光纤设施设计的全新型 OTDR。 此故障排除及验证工具不但功能强大、效率极高，而且包含有对校园网、数据中心以及存储光纤网络进行故障排除全部所需功能。<br />
<a href="http://www.faxytech.com/wp-content/uploads/2012/03/opro.jpg" class="highslide-image" onclick="return hs.expand(this);"><img title="福禄克Fluke OptiFiber Pro" src="http://www.faxytech.com/wp-content/uploads/2012/03/opro.jpg" alt="福禄克Fluke OptiFiber Pro" width="288" height="246" /></a></p>
<p>OptiFiber? Pro OTDR 通过业界唯一的智能手机界面提高了光纤测试的高度，让每一名技师都成为光纤专家。 DataCenter OTDR 配置可减少对数据中心光纤进行测试时所发生的不确定性和错误。 其超短的死区允许在虚拟数据中心进行光纤跳线测试。 这些功能，以及业界最快的扫描时间，使 OptiFiber Pro OTDR 成为您的必备工具。</p>
<p>现在我们先看看福禄克网络 OptiFiber PRO为客户如何解决问题的？</p>
<p><embed type="application/x-shockwave-flash" width="480" height="400" src="http://player.youku.com/player.php/sid/XNDk4NjMyOTQw/v.swf" quality="high" allowscriptaccess="always" allowfullscreen="true" align="middle"></embed></p>
<div id="11614a">
<h4>【福禄克】Fluke OptiFiber Pro OTDR(OFP-100-M,OFP-100-S)特性：</h4>
<p><strong>智能手机用户界面</strong></p>
<p>大多数 OTDR 都需要应付大量复杂情况，使用户界面难以浏览和阅读。 OptiFiber Pro 结合最新的“手势”界面技术和电容触摸屏为您提供了最新的用户友好 OTDR。</p>
<p>优势：</p>
<ul>
<li> 使用单击和重击来选择和滚动菜单项</li>
<li> 多点触摸收缩可方便地调整光纤曲线的显示比例</li>
<li> 以任务为中心的设备可减少前后屏的翻动次数</li>
<li> 电容触摸屏不像传统触摸屏幕那样需要<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span></li>
<li> 根据环境显示的屏幕帮助可为用户提供更多信息或问题解决建议</li>
</ul>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/Smartphone-User-Interface-Feature.jpg" alt="" /></p>
<div><strong>为数据中心优化</strong></div>
</div>
<div id="11615a">
<p>根据服务器虚拟化和服务器、网络存储之间的多兆连接的发展需求，数据中心架构采用了更多跳接线和密集拓扑连接器，使有长死区的电信级 OTDR 无效。 OptiFiber Pro 不仅使在数据中心部署光纤成为可能，更提供了最准确的的迅速解决问题的解决方案。</p>
<p>只需简单的一键选择，用户即可进入 DataCenter OTDR 模式 &#8211; 无需再进行 OTDR 的设置。 DataCenter OTDR 模式自动检测 OTDR 参数 &#8211; 端点检测算法，脉冲宽度等 &#8211; 而不会被短连接或连接器的数量干扰。</p>
<p>优势：</p>
<ul>
<li> 超短事件和衰减死区可精确地定位事件和光纤连接中的故障</li>
<li> DataCenter OTDR? 模式自动配置并迅速测试数据中心光纤</li>
<li> EventMap 功能以无需扫描分析专业知识即可看懂的方式说明光纤事件</li>
</ul>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/OTDR%20Setup.jpg" alt="" /></p>
<div><strong>灵活而有效的独特认证</strong></div>
</div>
<div id="11616a">
<p>合理安排日常使用对最大化 OTDR 的价值有重要意义。 项目经理可通过 OptiFiber Pro 内置的项目管理定义各用户的角色、设置和关联要执行的任务 – 使 OTDR 成为可计划、检查、认证和报告的万能光纤测试工具。</p>
<p>OptiFiber Pro 允许工作流程计划人员根据项目创建和管理操作员和工作配置 &#8211; 定义的工作或电缆 ID 可分配给特定操作员，从而提高了工作效率。 您还可方便地查看各项目的进展和状态。</p>
<p>优势：</p>
<ul>
<li> 全面的 OTDR 功能可根据各操作员的工作分配保证光纤性能。</li>
<li> 强大的项目管理功能可清晰地为操作员分配任务以促进 OTDR 共享</li>
<li> 利用完成/失败结果可方便地监控工作进展</li>
<li> 屏幕帮助可帮助您生成报告并上传到 <span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>? 应用程序</li>
</ul>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/Dynamic%20project%20and%20user%20profile%20management.jpg" alt="" /></p>
<div><strong>其它主要特点</strong></div>
</div>
<div id="11617a">
<p><strong>超短事件和衰减死区 </strong><br />
OptiFiber Pro <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e6%b5%8b%e8%af%95%e4%bb%aa" title="查看 光纤测试仪 的全部文章" target="_blank">光纤测试仪</a></span>利用最成熟的光学技术为所有 OTDR 提供最短事件死区（MM 通常为 0.5 m）和衰减死区（MM 通常为 2.2 m，SM 通常 为 3.6 m）。 这种技术优势使 OptiFiber Pro 能够检测超近距离故障，而这是目前富连接器数据中心和数据存储环境中的其它 OTDR 无法做到的。</p>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/Short%20Attenuation%20Zones.jpg" alt="" /></p>
<p><strong>LinkWare? management software</strong><br />
利用流行的 LinkWare 电缆测试管理软件应用程序，OptiFiber Pro 用户可简单方便地管理项目、制作报告并升级软件以管理工作流程和整理测试结果。</p>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/LinkWare%20management%20software.jpg" alt="" /></p>
<p><strong>每波长两秒扫描 </strong><br />
OptiFiber Pro 的划时代意义在于其采集速度。 在“快速测试”模式下，每波长只需短短两秒即可采集到一套完整数据。 OptiFiber Pro 然后分析数据并将其作为 EventMap、Table 或 Trace 显示出来。 最终结果是使用了更少的时间，从而可将更多时间用到其它工作上。</p>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/Test%20in%20progress.jpg" alt="" /></p>
<p><strong>屏幕帮助 – 修正措施 </strong><br />
屏幕“帮助”可在各测试步骤中显示用于解决光纤问题的修正措施建议。 这些“帮助”是与环境相关的，使用户能够迅速找到可能的解决方案。 左下角灰色图标中清晰地显示了详细的修正措施建议。</p>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/Help%20Screen.jpg" alt="" /></p>
<p><strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fiberinspector-mini.html" title="FiberInspector 袖珍光纤视频显微镜">FiberInspector</a></span>? 探头</strong><br />
OptiFiber Pro 视频检查系统可通过检查跳接线和接线板确定光纤连接故障的最大问题 – 污染。 由于探头是直接插到安装光纤端子的接线板中的，无需拆卸接线板，因此可节省大量时间。 技师为光纤指定一个通过或失败等级并附加一条注释，然后保存即可用于认证报告。</p>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/FiberInspector%20probe.jpg" alt="" /></p>
<h4>【福禄克】Fluke OptiFiber Pro OTDR(OFP-100-M,OFP-100-S)产品型号和配件</h4>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>OFP-100-M</td>
<td>OptiFiber Pro Multimode OTDR 套件。 套件中包含带 MM OTDR 模块的 OptiFiber Pro、便携带、交流适配器/充电器、USB 接口电缆 – 标准 A &#8211; micro B，用户指南 CD、LinkWare 软件 CD、入门指南、校准说明、注册卡、厂家保修和便携箱。</td>
</tr>
<tr>
<td>OFP-100-M/GLD</td>
<td>OptiFiber Pro 多模 OTDR 套件提供一年金牌支持。</td>
</tr>
<tr>
<td><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-mi.html" title="福禄克Fluke OFP-100-MI">OFP-100-MI</a></span></td>
<td>OptiFiber Pro Multimode OTDR 套件及检查套件。 套件中包含带 MM OTDR 模块的 OptiFiber Pro，2 SC/LC 多模启动线 — 50 ?m、1 SC/SC 多模启动线 — 50 ?m、USB 光纤检测视频探头和 4 端头，2 发射光纤工具包、OptiFiber Pro 便携带和手带、交流适配器/充电器、USB 接口电缆 – 标准 A &#8211; micro B、1 1.25 mm IBC OneClick 清洁剂、1 2.5 mm IBC OneClick 清洁剂、用户指南 CD、LinkWare 软件 CD、入门指南、校准说明、注册卡、厂家保修和便携箱。</td>
</tr>
<tr>
<td>OFP-100-MI/GLD</td>
<td>OptiFiber Pro 多模 OTDR 带检测包和 1 年金牌支持。</td>
</tr>
<tr>
<td>OFP-100-S</td>
<td>OptiFiber Pro Singlemode OTDR 套件。 套件中包含带 SM OTDR 模块的 OptiFiber Pro、便携带、交流适配器/充电器、USB 接口电缆 – 标准 A &#8211; micro B，用户指南 CD、LinkWare 软件 CD、入门指南、校准说明、注册卡、厂家保修和便携箱。</td>
</tr>
<tr>
<td>OFP-100-S/GLD</td>
<td>OptiFiber Pro 单模 OTDR 套件提供一年金牌支持。</td>
</tr>
<tr>
<td>OFP-100-SI</td>
<td>OptiFiber Pro Singlemode OTDR 套件及检查套件。 套件中包含带 SM OTDR 模块的 OptiFiber Pro，2 SC/LC 多模启动线 — 9 ?m、1 SC/SC 单模启动线 — 9 ?m、USB 光纤检测视频探头和 4 端头，2 发射光纤工具包、OptiFiber Pro 便携带和手带、交流适配器/充电器、USB 接口电缆 – 标准 A &#8211; micro B、1 1.25 mm IBC OneClick 清洁剂、1 2.5 mm IBC OneClick 清洁剂、用户指南 CD、LinkWare 软件 CD、入门指南、校准说明、注册卡、厂家保修和便携箱。</td>
</tr>
<tr>
<td>OFP-100-SI/GLD</td>
<td>OptiFiber Pro 单模 OTDR 带检测包和 1 年金牌支持。</td>
</tr>
<tr>
<td><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-q" title="查看 OFP-100-Q 的全部文章" target="_blank">OFP-100-Q</a></span></td>
<td>OptiFiber Pro Quad OTDR 套件。 套件中包含带 Quad OTDR 模块的 OptiFiber Pro、便携带、交流适配器/充电器、USB 接口电缆 – 标准 A &#8211; micro B，用户指南 CD、LinkWare 软件 CD、入门指南、校准说明、注册卡、厂家保修和便携箱。</td>
</tr>
<tr>
<td>OFP-100-Q/GLD</td>
<td>OptiFiber Pro Quad OTDR 套件提供一年金牌支持。</td>
</tr>
<tr>
<td>OFP-100-QI</td>
<td>OptiFiber Pro Quad OTDR 套件及检查套件。 套件中包含带 Quad OTDR 模块的 OptiFiber Pro，2 SC/LC 多模启动线 — 50 ?m、2SC/LC 单模启动线 — 9 ?m、1 SC/SC 多模启动线 — 50 ?m，1 SC/SC 单模启动线 — 9 ?mUSB 光纤检测视频探头和 4 端头，2发射光纤工具包、OptiFiber Pro 便携带和手带、交流适配器/充电器、USB 接口电缆 – 标准 A &#8211; micro B、1 1.25 mm IBC OneClick 清洁剂、1 2.5 mm IBC OneClick 清洁剂、用户指南 CD、LinkWare 软件 CD、入门指南、校准说明、注册卡、厂家保修和便携箱。</td>
</tr>
<tr>
<td>OFP-100-QI/GLD</td>
<td>OptiFiber Pro Quad OTDR 带检测包和 1 年金牌支持。</td>
</tr>
<tr>
<td>OFP-MM</td>
<td>OptiFiber Pro Multimode OTDR 模块。</td>
</tr>
<tr>
<td>OFP-SM</td>
<td>OptiFiber Pro Singlemode OTDR 套件。</td>
</tr>
<tr>
<td>OFP-QUAD</td>
<td>OptiFiber Pro Quad OTDR 套件。</td>
</tr>
<tr>
<td>OFP-FI</td>
<td>带选择性隔板和视频探头端头的 DI-1000 Inspector。</td>
</tr>
<tr>
<td>TFS</td>
<td>TFS 主机和电池。</td>
</tr>
</tbody>
</table>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td>OFPQI-MFP&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</td>
<td>数据中心光纤（多模/单模）故障处理套件 &#8211; 包括 OFP-100-QI、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MFTK1200">MFTK1200</a></span> 和 FI1000-<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span>-UTIP</td>
</tr>
<tr>
<td>OFPMI-MFP&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</td>
<td>数据中心光纤（多模）故障处理套件 &#8211; 包括 OFP-100-MI、MFTK1200 和 FI1000-MPO-UTIP</td>
</tr>
<tr>
<td>OFPQI-CER&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</td>
<td>企业光纤布线认证套件 &#8211; 包括 OFP-100-QI 和 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-CERTIFIBER-MS（单模和多模光纤）</td>
</tr>
<tr>
<td>OFPQI-MFP-CER&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</td>
<td>企业光纤布线认证和故障处理套件 &#8211; 包括 OFP-100-QI、MFTK1200、 FI1000-MPO-UTIP 和 DTX-CERTIFIBER-MS（单模和多模光纤）。</td>
</tr>
</tbody>
</table>
<div>零配件</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>MMC-50-SCSC</td>
<td>多模发射电缆 50 ?m SC/SC</td>
</tr>
<tr>
<td>MMC-50-SCLC</td>
<td>多模发射电缆 50 ?m SC/LC</td>
</tr>
<tr>
<td>MMC-50-SCST</td>
<td>多模发射电缆 50 ?m SC/ST</td>
</tr>
<tr>
<td>MMC-50-SCFC</td>
<td>多模发射电缆 50 ?m SC/FC</td>
</tr>
<tr>
<td>MMC-50-SCE2K</td>
<td>多模发射电缆 50 ?m SC/E2K</td>
</tr>
<tr>
<td>MMC-62-SCSC</td>
<td>多模发射电缆 62.5 ?m SC/SC</td>
</tr>
<tr>
<td>MMC-62-SCLC</td>
<td>多模发射电缆 62.5 ?m SC/LC</td>
</tr>
<tr>
<td>MMC-62-SCST</td>
<td>多模发射电缆 62.5 ?m SC/ST</td>
</tr>
<tr>
<td>MMC-62-SCFC</td>
<td>多模发射电缆 62.5 ?m SC/FC</td>
</tr>
<tr>
<td>SMC-9-SCSC</td>
<td>单模发射电缆 9 ?m SC/SC</td>
</tr>
<tr>
<td>SMC-9-SCLC</td>
<td>单模发射电缆 9 ?m SC/LC</td>
</tr>
<tr>
<td>SMC-9-SCST</td>
<td>单模发射电缆 9 ?m SC/ST</td>
</tr>
<tr>
<td>SMC-9-SCFC</td>
<td>单模发射电缆 9 ?m SC/FC</td>
</tr>
<tr>
<td>SMC-9-SCE2KAPC</td>
<td>单模发射电缆 9 ?m SC/E2000 APC</td>
</tr>
<tr>
<td>PA-SC</td>
<td>OTDR 源端口可互换 SC 适配器</td>
</tr>
<tr>
<td>PA-ST</td>
<td>OTDR 源端口可互换 ST 适配器</td>
</tr>
<tr>
<td>PA-FC</td>
<td>OTDR 源端口可互换 FC 适配器</td>
</tr>
<tr>
<td><span style="color: #000000; font-family: Simsun; font-size: medium; line-height: normal; text-align: center; background-color: #f5f5f5;"><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span>-电池</span></td>
<td><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/versiv" title="查看 Versiv 的全部文章" target="_blank">Versiv</a></span> 电池</td>
</tr>
<tr>
<td>TFS-CHGR</td>
<td>TFS 交流适配器/充电器，国际版</td>
</tr>
<tr>
<td>TFS-KIT-CASE</td>
<td>TFS 软包</td>
</tr>
<tr>
<td>TFS-HSTRAP</td>
<td>TFS 便携带</td>
</tr>
<tr>
<td>TFS-USB-CBL</td>
<td>USB 接口电缆标准 A &#8211; micro B</td>
</tr>
<tr>
<td>FI1000</td>
<td>OptiFiber Pro 的 FI-1000 FiberInspector USB 视频探头</td>
</tr>
<tr>
<td>FI1000-SCFC-TIP</td>
<td>SC 和 FC 隔板视频探头端头</td>
</tr>
<tr>
<td>FI1000-LC-TIP</td>
<td>LC 隔板视频探头端头</td>
</tr>
<tr>
<td>FI1000-ST-TIP</td>
<td>ST 隔板视频探头端头</td>
</tr>
<tr>
<td>FI1000-MU-TIP</td>
<td>MU 隔板视频探头端头</td>
</tr>
<tr>
<td>FI1000-E2KAPC-TIP</td>
<td>E2000/APC 隔板视频探头端头</td>
</tr>
<tr>
<td>FI1000-SCAPC-TIP</td>
<td>SC/APC 隔板视频探头端头</td>
</tr>
<tr>
<td>FI1000-E2K-TIP</td>
<td>E2000 隔板视频探头端头</td>
</tr>
<tr>
<td>FI1000-LCAPC-TIP</td>
<td>LC/APC 隔板视频探头端头</td>
</tr>
<tr>
<td>FI1000-2.5-UTIP</td>
<td>用于跳接线的 2.5 mm 通用视频探头端头</td>
</tr>
<tr>
<td>FI1000-1.25-UTIP</td>
<td>用于跳接线的 1.25 mm 通用视频探头端头</td>
</tr>
<tr>
<td>FI1000-2.5APC-UTIP</td>
<td>用于跳接线的 2.5 mm APC 通用视频探头端头</td>
</tr>
<tr>
<td>FI1000-MPO-UTIP</td>
<td>用于跳接线和隔板的 MPO/MTP 探头端头和转换旋钮</td>
</tr>
<tr>
<td>FI1000-MPOAPC-UTIP</td>
<td>用于跳接线和隔板的 MPO/APC 探头端头和转换旋钮</td>
</tr>
<tr>
<td>FI1000-1.25APC-TIP</td>
<td>用于跳接线的 1.25 mm APC 通用视频探头端头</td>
</tr>
<tr>
<td>FI1000-MPOAPC-RT</td>
<td>MPO/MTP APC 可替换端头不带转换旋钮</td>
</tr>
<tr>
<td>FI1000-MPO-RT</td>
<td>MPO/MTP 可替换端头不带转换旋钮</td>
</tr>
<tr>
<td>FI1000-TIP-KIT</td>
<td>LC,FC/SC 隔板、1.25和 2.5MM 通用端头（在一个盒子中）</td>
</tr>
<tr>
<td>TFS-STD</td>
<td>TFS 演示架</td>
</tr>
</tbody>
</table>
<div>支持</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>GLD-OFP-100-Q</td>
<td>OptiFiber Pro OTDR 提供 1 年金牌支持 &#8211; 型号： OFP-100-Q（也可提供 3 年支持：GLD3-OFP-100-Q）。</td>
</tr>
<tr>
<td>GLD-OFP-100-QI</td>
<td>OptiFiber Pro Quad OTDR 套件提供一年金牌支持，型号包括： OFP-100-QI（也可提供 3 年支持：GLD3-OFP-100-QI）。</td>
</tr>
<tr>
<td>GLD-OFP-100-M/S</td>
<td>OptiFiber Pro 多模或单模 OTDR 套件提供一年金牌支持，型号包括： OFP-100-M 或 OFP-100-S（也可提供 3 年支持：GLD3-OFP-100-M/S）。</td>
</tr>
<tr>
<td>GLD-OFP-100-MI/SI</td>
<td>带检测包的 OptiFiber Pro 多模或单模 OTDR 提供 1 年金牌支持 &#8211; 型号： OFP-100-MI 或 OFP-100-SI（也可提供 3 年支持：GLD3-OFP-100-MI/SI）。</td>
</tr>
<tr>
<td>GLD-OFP-MOD-Q</td>
<td>OptiFiber Pro Quad OTDR 套件提供一年金牌支持，型号包括： OFP-QUAD</td>
</tr>
<tr>
<td>GLD-OFP-MOD-M/S</td>
<td>OptiFiber Pro 多模或单模模块提供 1 年金牌支持 &#8211; 型号： OFP-MM 或 OFP-SM</td>
</tr>
<tr>
<td>GLD-FI</td>
<td>带选择性隔板和视频探头尖端的 DI-1000 Inspector 提供 1 年金牌支持 &#8211; - 型号： OFP-FI</td>
</tr>
<tr>
<td>GLD-TFS</td>
<td>带电池的 TFS 主机提供 1 年金牌支持 &#8211; 型号： TFS</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4>【福禄克】Fluke OptiFiber Pro OTDR(OFP-100-M,OFP-100-S)技术规格参数</h4>
<p><strong>OTDR 主要技术指标</strong></p>
<table id="SpecTable0" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td></td>
<td><strong>Multimode 模块</strong></td>
<td><strong>Singlemode 模块</strong></td>
<td><strong>Quad 模块</strong></td>
</tr>
<tr>
<td><strong>波长</strong></td>
<td>850 nm +/- 10 nm<br />
1300 nm +35/-15 nm</td>
<td>1310 nm +/- 25 nm<br />
1550 nm +/- 30 nm</td>
<td>850 nm +/- 10 nm<br />
1300 nm +35/-15 nm<br />
1310 nm +/- 25 nm<br />
1550 nm +/- 30 nm</td>
</tr>
<tr>
<td><strong>兼容光纤类型 </strong></td>
<td>50/125 ?m<br />
62.5/125 ?m</td>
<td>单模</td>
<td>50/125 ?m<br />
62.5/125 ?m<br />
单模</td>
</tr>
<tr>
<td><strong>事件死区 1</strong></td>
<td>850 nm ： 0.5 m（典型）<br />
1300 nm ： 0.7 m（典型）</td>
<td>1310 nm ： 0.6 m（典型）<br />
1550 nm ： 0.6 m（典型）</td>
<td>850 nm ： 0.5 m（典型）<br />
1300 nm ： 0.7 m（典型）<br />
1310 nm ： 0.6 m（典型）<br />
1550 nm ： 0.6 m（典型）</td>
</tr>
<tr>
<td><strong>衰减死区 2 </strong></td>
<td>850 nm ： 2.2 m（典型）<br />
1300 nm ： 4.5 m（典型）</td>
<td>1310 nm ： 3.6 m（典型）<br />
1550 nm ： 3.7 m（典型）</td>
<td>850 nm ： 2.2 m（典型）<br />
1300 nm ： 4.5 m（典型）<br />
1310 nm ： 3.6 m（典型）<br />
1550 nm ： 3.7 m（典型）</td>
</tr>
<tr>
<td><strong>动态范围3，5，6</strong></td>
<td>850 nm ： 一般为 28 dB<br />
1300 nm ： 一般为 30 dB</td>
<td>1310 nm ： 一般为 32 dB<br />
1550 nm ： 一般为 30 dB</td>
<td>850 nm ： 一般为 28 dB<br />
1300 nm ： 一般为 30 dB<br />
1310 nm ： 一般为 32 dB<br />
1550 nm ： 一般为 30 dB</td>
</tr>
<tr>
<td><strong>最大距离范围设置</strong></td>
<td>40 km</td>
<td>130 km</td>
<td>MM： 40 km<br />
SM： 130 km</td>
</tr>
<tr>
<td><strong>距离测量范围 4，5，7，8，9，10</strong></td>
<td>850 nm ： 9 km<br />
1300 nm ： 35 km</td>
<td>1310 nm ： 80 km<br />
1550 nm ： 130 km</td>
<td>850 nm ： 9 km<br />
1300 nm ： 35 km<br />
1310 nm ： 80 km<br />
1550 nm ： 130 km</td>
</tr>
<tr>
<td><strong>反射范围 4，5</strong></td>
<td>850 nm ： 一般为 -14 dB 至 -57 dB<br />
1300 nm ： 一般为 -14 dB 至 -62 dB</td>
<td>1310 nm ： 一般为 -14 dB 至 -65 dB<br />
1550 nm ： 一般为 -14 dB 至 -65 dB</td>
<td>850 nm ： 一般为 -14 dB 至 -57 dB<br />
1300 nm ： 一般为 -14 dB 至 -62 dB<br />
1310 nm ： 一般为 -14 dB 至 -65dB<br />
1550 nm ： 一般为 -14 dB 至 -65 dB</td>
</tr>
<tr>
<td><strong>采样分辨率</strong></td>
<td>3 cm 到 400 cm</td>
<td>3 cm 到 400 cm</td>
<td>3 cm 到 400 cm</td>
</tr>
<tr>
<td><strong>脉冲宽度（额定） </strong></td>
<td>850 nm ： 3, 5, 20, 40, 200 ns<br />
1300 nm ： 3, 5, 20, 40, 200, 1000 ns</td>
<td>1310/1550 nm： 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns</td>
<td>850 nm ： 3, 5, 20, 40, 200 ns<br />
1300 nm ： 3, 5, 20, 40, 200, 1000 ns<br />
1310/1550 nm： 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns</td>
</tr>
<tr>
<td rowspan="6"><strong>测试时间（每波长）</strong></td>
<td>自动设置： 一般为 5 秒</td>
<td>自动设置： 一般为 10 秒</td>
<td>自动设置：<br />
MM – 一般为 5 秒<br />
SM – 一般为 10 秒</td>
</tr>
<tr>
<td>快速测试设置：<br />
一般为 2 秒</td>
<td>快速测试设置：<br />
一般为 5 秒</td>
<td>快速测试设置：<br />
MM – 一般为 2 秒<br />
SM – 一般为 5 秒</td>
</tr>
<tr>
<td>最佳分辨率设置：<br />
2 到 180 秒</td>
<td>最佳分辨率设置：<br />
5 到 180 秒</td>
<td>最佳分辨率设置：<br />
MM – 2 到 180 秒 M<br />
SM – 5 到 180 秒</td>
</tr>
<tr>
<td>FaultMap 设置：<br />
2 秒（一般），180 秒（最大）</td>
<td>FaultMap 设置：<br />
10 秒（一般），180 秒（最大）</td>
<td>FaultMap 设置：<br />
MM &#8211; 2 秒（一般），MM &#8211; 180 秒（最大）<br />
SM &#8211; 10 秒（一般），SM &#8211; 180 秒（最大）</td>
</tr>
<tr>
<td>DataCenter OTDR 设置：<br />
1 秒（一般在 850 nm），7 秒（最大）</td>
<td>DataCenter OTDR 设置：<br />
20 秒（一般），40 秒（最大）</td>
<td>DataCenter OTDR 设置：<br />
MM – 1 秒（一般在 850 nm） MM – 7 秒（最大）<br />
SM – 20 秒（一般） SM – 40 秒（最大）</td>
</tr>
<tr>
<td>手动设置：<br />
3，5，10，20，40，60，90，120，180 秒</td>
<td>手动设置：<br />
3，5，10，20，40，60，90，120，180 秒</td>
<td>手动设置：<br />
-3，5，10，20，40，60，90，120，180 秒 SM &#8211; 3，5，10，20，40，60，90，120，180 秒</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<ol>
<li> 在低于最短脉冲宽度非饱和反射峰和 1.5 dB 之下测量。 反射峰多模 &lt; -40 dB，单模 &lt; &#8211; 50 dB。</li>
<li> 在偏离最短脉冲宽度反向散射 +/- 0.5 dB 处测量。 反射峰多模 &lt; -40 dB，单模 &lt; &#8211; 50 dB。</li>
<li> 对于 OM1 光纤典型的反向散射系数： 850: -65 dB, 1300: -72 dB.</li>
<li> OM2-OM4 光纤的典型反向散射和衰减系数： 850 nm ： -68 dB; 2.3 dB/km: 1300 nm ： -76 dB; 0.6 dB/km.</li>
<li> OM1-OM2 光纤的典型反向散射和衰减系数： 1310nm/1550nm ： -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.</li>
<li> SNR=1 方法，3 分钟平均，最大脉冲宽度。</li>
<li> 通常在 850 = 9 km 发现端点或通常在 7 km 发现 0.1 dB 事件（事件之前最大 18 dB 衰减）。</li>
<li> 通常在 1300 = 35 km 发现端点或通常在 30 km 发现 0.1 dB 事件（事件之前最大 18 dB 衰减）。</li>
<li> 通常在 1310 = 80 km 发现端点或通常在 60km 发现 0.1 dB 事件（事件之前最大 20 dB 衰减）。</li>
<li> 通常在 1550 = 130 km 发现端点或通常在 90 km 发现 0.1 dB 事件（事件之前最大 18 dB 衰减）。</li>
<li> 不包括折射率系数错误，也不包括自动事件位置错误。</li>
<li> dB 变化/1 dB 阶跃。</li>
<li> 应用于在 OTDR 可找到一个 0.1 dB 事件的距离范围内的轨迹反向散射。</li>
</ol>
<p>&nbsp;</p>
<p><strong>其它主要技术指标</strong></p>
<table id="SpecTable1" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td colspan="2">FiberInspector 探头技术指标</td>
</tr>
<tr>
<td>放大倍率</td>
<td>~ 200X 带 OptiFiber Pro 显示</td>
</tr>
<tr>
<td>光源</td>
<td>蓝色 LED</td>
</tr>
<tr>
<td>电源</td>
<td>TFS 主机</td>
</tr>
<tr>
<td>视野 (FOV)</td>
<td>水平： 425 ?m<br />
垂直： 320 ?m</td>
</tr>
<tr>
<td>最小可检测微粒大小</td>
<td>0.5 ?m</td>
</tr>
<tr>
<td>体积</td>
<td>大约 6.75 英寸 x 1.5 英寸（1175 毫米 x 35 毫米），无适配器端头</td>
</tr>
<tr>
<td>重量</td>
<td>200 g</td>
</tr>
<tr>
<td><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>范围</td>
<td>工作时： 32°F 至 122°F (0 °C 到 +50 °C)<br />
存放： -4°F 至 +158°F（-20°C 至 +70°C）</td>
</tr>
<tr>
<td>合格证</td>
<td>CE（使用主机时）</td>
</tr>
</tbody>
</table>
<table id="SpecTable2" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td colspan="2">VFL 技术指标</td>
</tr>
<tr>
<td>开关控制</td>
<td>机械开关和触摸屏幕上的按钮</td>
</tr>
<tr>
<td>输出功率</td>
<td>316 μW (-5 dBm) = 峰值功率 = 1.0 mW (0 dBm)</td>
</tr>
<tr>
<td>工作波长</td>
<td>650 nm 额定</td>
</tr>
<tr>
<td>谱宽 (RMS)</td>
<td>±3 nm</td>
</tr>
<tr>
<td>输出模式</td>
<td>连续波和脉冲模式（2 Hz &#8211; 3 Hz 闪烁频率）</td>
</tr>
<tr>
<td>接头适配器</td>
<td>2.5 mm 通用</td>
</tr>
<tr>
<td>激光安全性（类别）</td>
<td>II 类 CDRH 符合 EN 60825-2</td>
</tr>
</tbody>
</table>
<table id="SpecTable3" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td colspan="2">一般规格</td>
</tr>
<tr>
<td>重量</td>
<td>带模块和电池的主机： 3 磅，5 盎司（1.28 千克）</td>
</tr>
<tr>
<td>体积</td>
<td>带模块和电池的主机： 2.625 英寸 x 5.25 英寸 x 11.0 英寸（6.67 厘米 x 13.33 厘米 x27.94 厘米）</td>
</tr>
<tr>
<td>电池</td>
<td>锂离子电池组，7.2 V</td>
</tr>
<tr>
<td>电池寿命</td>
<td>八小时自动 OTDR 运行，双波长，无视频探头连接，150 m 光纤</td>
</tr>
<tr>
<td><strong>充电时间</strong></td>
<td></td>
</tr>
<tr>
<td>测试仪关</td>
<td>电量从 10% 充到 90% 需四小时</td>
</tr>
<tr>
<td>测试仪开</td>
<td>测试仪开启时电量从 10% 充到 90% 需要六小时</td>
</tr>
</tbody>
</table>
<table id="SpecTable4" border="0" cellspacing="0" cellpadding="0" width="100%" bordercolor="black">
<tbody>
<tr>
<td colspan="2">环境技术指标</td>
</tr>
<tr>
<td>工作温度*</td>
<td>-18?C 至 45?C</td>
</tr>
<tr>
<td>非操作温度</td>
<td>-30?C 至 60?C</td>
</tr>
<tr>
<td>操作高度</td>
<td>4,000 m (13123 ft)<br />
3200 米（10,500 英尺）带交流适配器</td>
</tr>
<tr>
<td>存储高度</td>
<td>12,000 米</td>
</tr>
<tr>
<td>EMC</td>
<td>EN 61326-1</td>
</tr>
</tbody>
</table>
<p>* 使用电池供电。 带 AC 适配器： 0?C 至 45?C。 每 15 分钟时间段时实时扫描功能不能使用超过 5 分钟。 使用实时扫描功能的最高环境温度为 35?C。<br />
* 请不要将电池保存于低于 -20°C (-4°F) 或高于 50°C (122°F) 的环境下超过一个星期，以免损坏电池容量。</p>