		<item>
		<title>福禄克(DSX8000/DSX5000)外部串扰自动测试电缆（二）</title>
		<link>http://www.faxytech.com/archives/axtlak-2.html</link>
		<comments>http://www.faxytech.com/archives/axtlak-2.html#comments</comments>
		<pubDate>Wed, 17 Jun 2020 05:38:12 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[dsx8000]]></category>
		<category><![CDATA[外部串扰]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[自动测试电缆]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11541</guid>
		<description><![CDATA[执行外部串扰测试之前，必须利用 DTX-1800 或 DSX 测试仪（DSX2-8000、DSX2-5000）对电缆束中的每条电缆进行自动测试。自动测试会告诉您是否每条电缆都能支持 IEEE 802.3 10GBASE-T 标准。还能测量 AxTalk... ]]></description>
			<content:encoded><![CDATA[<p>执行<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%a4%96%e9%83%a8%e4%b8%b2%e6%89%b0" title="查看 外部串扰 的全部文章" target="_blank">外部串扰</a></span>测试之前，必须利用 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span> 或 DSX 测试仪（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx2-8000.html" title="福禄克FLUKE DSX2-8000">DSX2-8000</a></span>、<span class='wp_keywordlink'><a href="http://www.faxy-tech.com/Products/DSX2-5000.html" title="福禄克FLUKE DSX2-5000">DSX2-5000</a></span>）对电缆束中的每条电缆进行自动测试。自动测试会告诉您是否每条电缆都能支持 IEEE  802.3 10GBASE-T 标准。还能测量 AxTalk 分析仪所需的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>，以计算 PS ANEXT 和 PS AACR-F  的通过/失败限值。此外，AxTalk 分析仪还能让您从 <span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span> 数据库中选择受干扰链路和干扰链路。</p>
<p>注：您必须使用相同类型的测试仪  <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span> 或 DSX 8000或者DSX5000对链路进行自动测试和外部串扰测试。</p>
<p>&nbsp;</p>
<p><strong>执行自动测试</strong></p>
<ol>
<li>启动主测试仪和远程测试仪，然后将其连接到电缆束中某根电缆的另一端。利用永久链路适配器连接到配线板或墙壁插座。利用信道适配器连接到配线板。</li>
<li>在主测试仪上，选择一种双绞线对测试限制，以便在高达 500 MHz 的频率下进行测试（比如 TIA TSB-155、ISO  TR 24750、TIA Cat 6A 或 ISO EA 类）。</li>
<li>在主测试仪上将存储绘图数据设置为标准或扩展。</li>
<li>执行自动测试，然后保存测试结果。</li>
</ol>
<p>注：AxTalk  分析仪将会显示执行自动测试的电缆 ID。</p>
<p>5.对装置中的每条电缆执行自动测试，然后保存所有的测试结果。</p>
<p>注：有关自动测试的更多说明，请参阅您的测试仪随附的资料。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/axtlak-2.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>从福禄克DSP到DTX1800到DSX-5000与DSX8000，我们经历了什么？</title>
		<link>http://www.faxytech.com/archives/dsp-dtx-dsx8000.html</link>
		<comments>http://www.faxytech.com/archives/dsp-dtx-dsx8000.html#comments</comments>
		<pubDate>Thu, 27 Apr 2017 09:41:49 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dsp4000]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[dsx8000]]></category>
		<category><![CDATA[dtx1800]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8818</guid>
		<description><![CDATA[1、DSP4000系列电缆分析仪 1994年福禄克推出基于全数字处理技术的电缆分析仪，由于使用了DSP芯片，故取名DSP电缆分析仪。 这在当时是个划时代的产品。因为那时的电缆测试仪都是基于“扫频仪... ]]></description>
			<content:encoded><![CDATA[<h4><strong>1、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsp-4000series.html" title="福禄克Fluke　DSP4000">DSP4000</a></span>系列电缆分析仪</strong></h4>
<p>1994年<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>推出基于全数字处理技术的电缆分析仪，由于使用了<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsp-4000series.html" title="福禄克FLuke DSP">DSP</a></span>芯片，故取名DSP电缆分析仪。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/04/DSP4000.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8819" title="福禄克FLUKE DSP4000" src="http://www.faxytech.com/wp-content/uploads/2017/04/DSP4000.jpg" alt="福禄克FLUKE DSP4000" width="449" height="335" /></a></p>
<p>这在当时是个划时代的产品。因为那时的<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="电缆测试仪">电缆测试仪</a></span>都是基于“扫频仪+信号接收仪”原理设计的，使用模拟信号方式进行测试和分析。时至今日，台式的网分(NA或VNA)仍是这样的产品，并无大的变化。</p>
<p>同期，福禄克还有MicroTest模拟测试产品在售。</p>
<p>当时的测试对象是双绞线数据电缆和双绞线总线，由于速度低、信号端口多为2线对单向全双工(例如10/100Base-T以太网)，故主要要求对损耗、(线对间)串扰做测试。</p>
<p>进入上世纪90年代后期，随着1GBase-T的出现以及总线速度的提速，信号端口改为1线对双向全双工。这就带来单线对回波对自身的影响，故测试指标和功能增加了<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>(Return Loss)这个参数，且用回波损耗参数代替特性<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>参数进行测试。</p>
<p><img src="data:image/gif;base64,iVBORw0KGgoAAAANSUhEUgAAAAEAAAABCAYAAAAfFcSJAAAADUlEQVQImWNgYGBgAAAABQABh6FO1AAAAABJRU5ErkJggg==" alt="" /></p>
<p>这样的好处是避免了<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="特性阻抗">特性阻抗</a></span>连续性测试的麻烦，而回波损耗参数又可以通过傅立叶变换很容易得到TDR曲线，这条曲线非常直观地指示出阻抗不连续的物理定位(故障位置)。</p>
<p>同时，DSP还利用类似的TDX原理来定位串扰过大的物理位置。</p>
<p>福禄克公司并为此申请了HDTDR/HDTDX专利。</p>
<p>测试适配器方面，由于基本链路并不适合现场大量测试的稳定性，后来被永久链路替代。但永久链路仍存在测试跳线的不稳定性，于是2002年福禄克推出了专门的永久链路适配器，取代使用厂商跳线测试带来的测试不确定性。</p>
<p>随着六类线的推出，不同厂商间系统不兼容问题突出，永久链路的可更换测试尖头推出了适合厂商不兼容性的个性化模块PMxx，其中<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx_1800_pm06.html" title="PM06">PM06</a></span>是被标准推荐的居中性模块，用于认证厂商之间是否可以实现最低限度的“跳线可互换”。</p>
<p>&nbsp;</p>
<p>DSP系列电缆分析仪2004年下市。</p>
<p>&nbsp;</p>
<h4><strong>2、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克DTX 1800">DTX1800</a></span>系列电缆分析仪</strong></h4>
<p>随着网络速度越来越高，对电缆的潜力挖掘也进一步深入。由于北美主要推崇性价比优异的非屏蔽双绞线，福禄克公司预见到只考虑线对间串扰是不够的，于是于2004年推出了<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>系列<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="线缆分析仪">线缆分析仪</a></span>。</p>
<p><img src="http://www.faxy-tech.com/UploadFiles/Others/dtx1800-3.jpg" alt="" /><img src="data:image/gif;base64,iVBORw0KGgoAAAANSUhEUgAAAAEAAAABCAYAAAAfFcSJAAAADUlEQVQImWNgYGBgAAAABQABh6FO1AAAAABJRU5ErkJggg==" alt="" /></p>
<p>&nbsp;</p>
<p>除了测试速度比DSP更快以外，主要的变化就是可以支持缆间串扰测试(即外部串扰测试)。这对于万兆以太网尤其重要。测试精度IV级。</p>
<p>当然，DTX保留并增强了专利技术HDTDR/HDTDX，定位精度更高。</p>
<p><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>成为市场占有率最大的产品，并成为事实上的比对标准。</p>
<p>由于用户的恋旧情绪，DTX系列于2015年比计划延迟2年下市。</p>
<p>&nbsp;</p>
<h4>3、<strong>DSX5000系列电缆分析仪（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX8000">DSX8000</a></span>新品上市）</strong></h4>
<p>随着本世纪大量个人wifi设备的出现(外加基站/微波炉/无线视频探头等辐射)，以及数据机房单个机架用电量的增长(电力谐波和接地回路干扰增强)，加上工业以太网和物联网的快速推进，双绞线的电磁工作环境比上个世纪90年代恶化了不少。这导致上个世纪制定的测试指标虽然测试合格且参数优秀，但链路仍然可能出现丢包率超标的问题。针对这一情况，TIA和ISO都于2010年提出要对双绞线的抗外来辐射干扰能力(平衡参数)进行检测，并推出了三个新指标：不平衡电阻、TCL和ELTCTL。由于DTX设计时并未考虑这一新要求，故将平衡参数测试功能转到新设计的DSX电缆分析仪中。</p>
<p><img src="http://www.faxy-tech.com/UploadFiles/Others/4d(13).jpg" alt="" /></p>
<p><img src="data:image/gif;base64,iVBORw0KGgoAAAANSUhEUgAAAAEAAAABCAYAAAAfFcSJAAAADUlEQVQImWNgYGBgAAAABQABh6FO1AAAAABJRU5ErkJggg==" alt="" /></p>
<p>DSX电缆分析仪除速度提升，物理带宽提升外(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span> 1000MHz，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span> 2000MHz)，最主要的变化就是引入了抗外来辐射干扰的测试能力(平衡参数测试)，另外精度也达到新标准的要求(V/VI,?2G)，外部串扰测试能力内置为一体化，使用更加方便。</p>
<p>可以认为，DSX系列电缆分析仪是迄今为止唯一满足标准要求的手持式现场测试仪。</p>
<p>另外不平衡电阻这个参数还具有双重功能，除了可以直接引起双绞线的不平衡外，还可以引起PoE设备因为此参数超标而导致“48V电源输送成功但信号传输能力下降或失败”的特殊现象。</p>
<p>此外，DSX默认还能对高速率数据处传送要求避免的虚接地情况进行识别并定位故障的物理位置(DTX测需要改装一下测试跳线)。</p>
<p>测试参数的历史沿革和演变简单地说就是：</p>
<p>&nbsp;</p>
<p>90年代上半期: IL,?<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>等,?(HDTDR/HDTDX)</p>
<p>90年代末期:?IL,?NEXT,?RL等,?(HDTDR/HDTDX)</p>
<p>2000年代前半期:?IL,?NEXT,?RL等,?(HDTDR/HDTDX)</p>
<p>2000年代后半期:?IL,?NEXT,?RL,?AxTalk等,?(HDTDR/HDTDX)</p>
<p>2010年代:?IL,?NEXT,?RL,?AxTalk,?TCL,?ELTCTL,?UBR(不平衡电阻)等,?(HDTDR/HDTDX, 虚接地)</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/04/DSP-DTX-DSX.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8820" title="DSP4000升级DTX1800升级DSX5000" src="http://www.faxytech.com/wp-content/uploads/2017/04/DSP-DTX-DSX.jpg" alt="DSP4000升级DTX1800升级DSX5000" width="640" height="360" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsp-dtx-dsx8000.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DSX-8000与DSX-5000的区别？</title>
		<link>http://www.faxytech.com/archives/dsx8000-dsx5000.html</link>
		<comments>http://www.faxytech.com/archives/dsx8000-dsx5000.html#comments</comments>
		<pubDate>Mon, 27 Feb 2017 01:59:08 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[新闻资讯]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[DSX-8000]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[dsx8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[Versiv]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8611</guid>
		<description><![CDATA[本月，福禄克网络在中国发布了业界首款真正的 8 类现场测试仪—— DSX-8000，立即引起了业界专家的高度关注。近期不断有福友咨询8类线测试和DSX-8000的问题，小福把备受大家关注的问题整理... ]]></description>
			<content:encoded><![CDATA[<p>本月，福禄克网络在中国发布了业界首款真正的 8 类现场测试仪—— <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span>，立即引起了业界专家的高度关注。近期不断有福友咨询8类线测试和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-8000" title="查看 DSX-8000 的全部文章" target="_blank">DSX-8000</a></span>的问题，小福把备受大家关注的问题整理了一下，列在下面以飨各位福友。</p>
<h4><strong>NO.1 ?8 类布线有哪些相关标准？</strong></h4>
<p>8类布线相关的标准和主要要求如下：</p>
<p>2016年9月8日发布于的 IEEE 802.3bq 25G/40GBASE-T：此标准规定了双绞线信道上应用的最小传输特性以支持 25 Gbps 和 40 Gbps 的基于双绞线的布线。</p>
<p>2016年6月30日发布的 ANSI/TIA-568-C.2-1：规定了8类通道和永久链路并包括有电阻不平衡、TCL、ELTCTL 的限制。</p>
<p>2016年11月10日发布于的 ANSI/TIA-1152-A：规定了8类的现场测试仪测量和精度要求，包括8类测试仪的新 &#8220;2G&#8221; 精度要求。</p>
<p>2017将预期发布 ISO/IEC 标准，包括规定了 I/II 类信道和永久链路的 ISO/IEC 11801-99-1 以及规定了测试仪测量和精度要求的 IEC 61935-1 Ed5.0，包括与 ANSI/TIA1152-A 相同的 &#8220;2G&#8221; 要求。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/02/cat8.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8612" title="cat8" src="http://www.faxytech.com/wp-content/uploads/2017/02/cat8.jpg" alt="" width="500" height="331" /></a></p>
<h4><strong>No2 ?8 类解决方案预计何时发布？</strong></h4>
<p>撰写此文时，尚无任何供应商发布 8 类布线解决方案，虽然 <span class='wp_keywordlink'><a href="http://www.faxytech.com/products/cabling-system/panduit" title="Panduit">Panduit</a></span> 和 Leviton 宣布并展示了经过独立验证的解决方案。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/02/solution.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8613" title="Cat 8类解决方案" src="http://www.faxytech.com/wp-content/uploads/2017/02/solution.jpg" alt="" width="640" height="256" /></a></p>
<h4><strong>No.3 ?8 类布线的情况如何？</strong></h4>
<p>8 类解决方案专用于支持最长距离 30 米、速率高达 40 Gbps (40GBASE-T) 的以太网，使其成为主要面向数据中心的解决方案。<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>布线安装时成本较低，但是可以大大节省相关的耗电和电子成本。如果 8 类/ 40GBASE-T 得到广泛部署，那么支持它的交换机和服务器连接会比使用光纤的成本低得多。此外，25/40GBASE-T 标准支持自动协商机制，这为数据中心运营商提供了方便。</p>
<p>另外将来其他应用也可能会采用 8 类。</p>
<p>&nbsp;</p>
<h4><strong>No.4 ?为什么 DSX-8000 是首款“真正”的8 类现场测试仪？</strong></h4>
<p>DSX-8000 有四个“首创”功能使其成为“真正”的 8 类现场测试仪。</p>
<ul>
<li>首款具有完整 2 GHz 范围的永久链路和通道适配器。这些适配器可以在现场连接到已安装链路，这正是安装 8 类系统的承包商所需要的。</li>
<li>首款获得 8 类布线制造商认可的测试仪。认证已安装布线的主要原因之一就是获得制造商的保证。如果未获得他们的认可，认证就毫无意义。</li>
<li>首款经过独立验证满足 Cat 8 测试仪测量精度所需的 ANSI/TIA-1152-A 2G 级要求的测试仪。</li>
<li>首款根据 Level 2G 测试仪的要求测试电缆通路中屏蔽层连通性的测试仪（以及 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>）</li>
</ul>
<p><img src="http://www.faxy-tech.com/UploadFiles/Product/2017-02-08/20170208113022782.png" alt="" width="540" height="378" /></p>
<h4><strong>No.5 ?DSX-8000 能测试“低于” 8 类的标准吗？</strong></h4>
<p>是的，DSX-8000 可测试 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-5000" title="查看 DSX-5000 的全部文章" target="_blank">DSX-5000</a></span> 能测试的所有铜缆布线类型。</p>
<p>&nbsp;</p>
<h4><strong>No.6 ?DSX-8000 的测试时间是多少？</strong></h4>
<p>DSX-8000 是市场上最快的测试仪，6A 类认证只需八秒。8 类的测试时间是 16 秒。</p>
<p>&nbsp;</p>
<h4><strong>No.7 测试“电缆通路中屏蔽层连通性”的要求是什么？</strong></h4>
<p>这是 ANSI/TIA-1152-A 中对 Level 2G 测试仪的要求。8 类是一个屏蔽系统，要求电缆上的屏蔽层连接到屏蔽连接器的两端。这可提高串扰性能，特别是外部串扰。所以，能够验证屏蔽层是否连接正确是认证系统性能的关键。大部分测试仪（包括 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>）都使用简单的 DC 连通性测试进行此类验证。遗憾的是，这种测试会被测试信号的替代通路欺骗，例如通用地线或另一根电缆上的屏蔽层。DSX-5000 和 8000 采用更成熟的方法，可以测定“电缆通路中”屏蔽层的连通性是否可以维持。它也可以显示到屏蔽故障的距离，从而大幅简化了故障排除。</p>
<p>&nbsp;</p>
<p><strong>No.8 ?DSX-8000 还能执行哪些其他测试？</strong></p>
<p>DSX CableAnalyzer 系列（DSX-5000 和 DSX-8000）仍然是可执行以下测量的现场<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="电缆测试仪">电缆测试仪</a></span>：</p>
<ul>
<li>电阻不平衡：这对 PoE 的运行成功很重要</li>
<li>TCL 和 ELTCL 不平衡测量：这对 10GBase-T 的成功运行很重要。</li>
</ul>
<p>如上所述，这些测试是布线和连接器的 ANSI/TIA-568-C.2-1 标准的一部分，但不是现场测试仪必需的。DSX 用户在选择“测试限制”时选择 +ALL 即可使用这些测试</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/03/TCL1.png" class="highslide-image" onclick="return hs.expand(this);"><img title="横向变换损耗" src="http://www.faxytech.com/wp-content/uploads/2014/03/TCL1.png" alt="" width="192" height="256" /></a> <a href="http://www.faxytech.com/wp-content/uploads/2014/03/TCL2.png" class="highslide-image" onclick="return hs.expand(this);"><img title="横向变换损耗" src="http://www.faxytech.com/wp-content/uploads/2014/03/TCL2.png" alt="" width="192" height="256" /></a> <a href="http://www.faxytech.com/wp-content/uploads/2014/03/TCL3.png" class="highslide-image" onclick="return hs.expand(this);"><img title="横向变换损耗" src="http://www.faxytech.com/wp-content/uploads/2014/03/TCL3.png" alt="" width="192" height="256" /></a></p>
<h4><strong>No.9 ?DSX-8000 是否符合 ISO/IEC Class I/II 要求？</strong></h4>
<p>是的，但是 Class II 需要用于 TERA 和 GG-45 类型连接器的适配器。这些适配器将于 2017 年夏天推出。注意此时市场上还没有 Class II TERA 或 GG45 连接器。</p>
<p>&nbsp;</p>
<h4><strong>No.10 ?DSX-8000 是不是 <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> 产品系列的一部分？</strong></h4>
<p><strong>如果是，它是否使用和 DSX-5000 和其他 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/versiv" title="查看 Versiv 的全部文章" target="_blank">Versiv</a></span> 产品相同的 Versiv 框架和远端？</strong></p>
<p>是的，DSX-8000 是 Versiv 线缆认证系列的一部分并使用与其他 Versiv 产品（DSX-5000、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> Pro、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> Pro 和 FI-7000）相同的框架和远端。Versiv 系列采用模块化设计，配备可插拔的测试模块，可以提供四种类型的测试，以及报告生成软件和和用于管理工作的云服务。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2013/06/Versiv1.jpg" class="highslide-image" onclick="return hs.expand(this);"><img title="福禄克Fluke Versiv" src="http://www.faxytech.com/wp-content/uploads/2013/06/Versiv1.jpg" alt="福禄克Fluke Versiv" width="390" height="308" /></a></p>
<h4><strong>No.11 ?DSX-5000 适配器是否可用于 DSX-8000？</strong></h4>
<p><strong>DSX-8000 适配器是否可用于 DSX-5000？</strong></p>
<p>下面的图表显示了两种测量模块及其适配器之间的兼容性。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/02/dsx8000.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8614" title="dsx8000与DSX-5000的区别" src="http://www.faxytech.com/wp-content/uploads/2017/02/dsx8000.jpg" alt="dsx8000与DSX-5000的区别" width="640" height="553" /></a></p>
<p>&nbsp;</p>
<h4><strong>No.12 DSX-8000 是否兼容 Versiv / <span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span> PC / LinkWare Live？</strong></h4>
<p>是的，DSX-8000 完全兼容所有 Versiv 模块并兼容 LinkWare Live 和 LinkWare PC。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2013/06/LinkWare1.jpg" class="highslide-image" onclick="return hs.expand(this);"><img title="LinkWare" src="http://www.faxytech.com/wp-content/uploads/2013/06/LinkWare1.jpg" alt="LinkWare" width="480" height="338" /></a></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2013/06/LinkWare1.jpg" class="highslide-image" onclick="return hs.expand(this);"></a></p>
<h4><strong>No.13购买 Cat 8 测试仪时我应考虑哪些方面？</strong></h4>
<p>如果您要购买测试仪，您应认真地考虑是否应该升级购买到 DSX-8000。测试仪属于长期投资 – 有数千十多年的 DTX 现在仍在使用中。鉴于时间跨度这么大，所以很难预测您是否会遇到 Cat 8 技术。<strong>DSX-8000 和 DSX-5000 之间的成本差异相对较小，但之后升级到 Cat 8 的成本要高得多，所以 DSX-8000 会是更安全的投资。</strong></p>
<p><img src="http://www.faxy-tech.com/UploadFiles/Others/1d(23).jpg" alt="" width="480" height="360" /></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx8000-dsx5000.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Fluke Networks 屏蔽完整性解决方案(DTX与DSX的区别）</title>
		<link>http://www.faxytech.com/archives/fluke-shield.html</link>
		<comments>http://www.faxytech.com/archives/fluke-shield.html#comments</comments>
		<pubDate>Fri, 10 Feb 2017 01:30:15 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[dsx8000]]></category>
		<category><![CDATA[dtx]]></category>
		<category><![CDATA[dtx1800]]></category>
		<category><![CDATA[Fluke Networks]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8531</guid>
		<description><![CDATA[屏蔽布线系统现场测试一直要求测试仪能够验证直至测试远端的屏蔽连续性，但是部分现场测试仪会错误地报告，无法找出布线系统的潜在问题。 本文讨论测量屏蔽连续性相关的问题、它对布... ]]></description>
			<content:encoded><![CDATA[<div>
<div><a href="http://www.faxytech.com/wp-content/uploads/2017/02/DSX5000.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8532" title="福禄克FLUKE DSX5000" src="http://www.faxytech.com/wp-content/uploads/2017/02/DSX5000.jpg" alt="福禄克FLUKE DSX5000" width="464" height="320" /></a></div>
<div>
<div>
<p>屏蔽布线系统现场测试一直要求测试仪能够验证直至测试远端的屏蔽连续性，但是部分现场测试仪会错误地报告，无法找出布线系统的潜在问题。</p>
<p>本文讨论测量屏蔽连续性相关的问题、它对布线测试参数的影响以及 <span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> 屏蔽完整性方法如何正确地保证布线安装符合 TIA 1152A 的 2G 级要求。</p>
</div>
</div>
</div>
<div>
<p>屏蔽连续性路径</p>
<p>Continuity of the screen is often thought of as a simple electrical connection between the screen contacts of the near end and remote testers.虽然其中有 3 条主要路径，但只有一条路径可以保证布线终止正确，使线缆能够按设计的方式运行。</p>
<p>图 1 显示的是屏蔽未连接到线缆的永久链路，但它通过面板、机架和建筑接地线具有与远程测试仪的电气连接。在这种情况下，部分屏蔽测试仪可能会报告屏蔽连续性正确无误，即使布线屏蔽是开路。</p>
<div><a href="http://www.faxytech.com/wp-content/uploads/2017/02/shield.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8533" title="shield" src="http://www.faxytech.com/wp-content/uploads/2017/02/shield.jpg" alt="" width="656" height="260" /></a><br />
图 1 – 通过建筑地面的屏蔽路径&nbsp;</p>
</div>
</div>
<div>
<p>图 2 是另一个测试仪可能报告屏蔽连续性正确但实际是开路的情况。在这种情况下，远端机架未通过建筑地面连接，但相同的机架之间有另一个正确终止屏蔽的链路并为开路屏蔽的链路提供了屏蔽连续性路径。</p>
<div><a href="http://www.faxytech.com/wp-content/uploads/2017/02/shield-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8534" title="shield-2" src="http://www.faxytech.com/wp-content/uploads/2017/02/shield-2.jpg" alt="" width="656" height="200" /></a><br />
图 2 – 通过另一个兼容链路的屏蔽路径&nbsp;</p>
</div>
<p>部分测试仪会不可避免地得到这些错误结果，但 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx" title="查看 DSX 的全部文章" target="_blank">DSX</a></span> 5000/<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span> CableAnalyzers ?能够检测这些情况，仅报告待测线缆的屏蔽连续性。这样用户可以保证所测链路或通道的屏蔽连接能够实现所需的传输性能。</p>
</div>
<div>
<div>
<div>
<div>
<p>&nbsp;</p>
<h4><strong>屏蔽连续性和外来串扰</strong></h4>
<p>屏蔽布线系统不仅使用均衡的线缆设计，而且使用金属箔作为法拉第笼隔绝耦合线对间的干扰，所以有非常高的抗外来串扰性能。为了让其能够有效地运行，耦合到屏蔽层的信号应通过线缆屏蔽层引导到地下连接器屏蔽层、面板，然后从那里导入建筑地面。如果其中任意路径是开路，则屏蔽会浮向地面，从而降低隔离性能，增加外来串扰。这会造成很大的影响，在部分情况下会降低外来串扰性能，高达 15dB。</p>
<p>正确的屏蔽接地对 <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span> 和 FEXT 等其他参数也有重要意义，而且对使用屏蔽技术降低线对间串扰的系统尤为重要，例如 Class FA?和 Class II 布线。</p>
<p>结合传统 DC 连续性方法和屏蔽完整性技术，<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fluke-networks" title="查看 Fluke Networks 的全部文章" target="_blank">Fluke Networks</a></span> DSX 5000/8000 CableAnalyzer 能够正确地识别建筑地面或其他兼容布线导致的开路，从而确保布线能够提供兼容的外来串扰和 10/25/40Gb 应用支持。这些方法也可以找出到屏蔽故障的距离，在开路屏蔽的情况下极大地减少故障排除时间。</p>
<p>&nbsp;</p>
<h4><strong>工业标准符合性</strong></h4>
<p>屏蔽连续性测试一直在现场测试仪标准 TIA 1152 和 IEC 61935-1 中有所规定，但是并没有说明该连续性路径的相关指导。</p>
<p>TIA 1152A 第一次解决了这个问题，澄清了用于测试 8 类布线的 2G 级测试仪的屏蔽测试要求。</p>
</div>
</div>
<div>
<div>
<p><strong>“另外，众所周知，对于 2G 级测试仪，屏蔽连续性要沿布线路径进行测试”<br />
– TIA 1152A 第 4.2.2 条</strong></p>
</div>
</div>
<div>
<div>
<p>因为许多 V 级及以下测试仪不符合此规范，所以这仅适用于 8 类 2G 级测试仪，进一步强调了屏蔽连接的重要性和 8 类应用的外来串扰。</p>
<p>Fluke Networks 不仅符合高达 TIA 8 类和 ISO/IEC Class II 中关于 Level 2G DSX 8000 的要求，同样符合 V 级 DSX 5000，涵盖高达 TIA Class EA 和 ISO/IEC Class FA?的所有类别。</p>
</div>
</div>
</div>
</div>
<div>
<div>
<div>
<div>
<p>&nbsp;</p>
<h4><strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span> 和 DSX 系列测试仪之间的差异</strong></h4>
<p>对屏蔽连续性测量使用屏蔽完整性技术是 DSX 5000/<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX8000">DSX8000</a></span> CableAnalyzer 的标配。DTX CableAnalyzer 和部分其他线缆测试仪制造商依靠基本连续性测量技术，这会造成如表 1 所示的错误结果。</p>
</div>
</div>
<div>
<div>
<table>
<tbody>
<tr>
<th>所测布线的开路屏蔽</th>
<th>建筑地面连接</th>
<th>辅助兼容链路连接</th>
<th>DTX/其他屏蔽连续性结果</th>
<th>DSX 屏蔽连续性结果</th>
<th>正确的结果</th>
</tr>
<tr>
<td>否</td>
<td>否</td>
<td>否</td>
<td>?</td>
<td>?</td>
<td rowspan="4">DTX &amp; DSX</td>
</tr>
<tr>
<td>否</td>
<td>否</td>
<td>是</td>
<td>?</td>
<td>?</td>
</tr>
<tr>
<td>否</td>
<td>是</td>
<td>否</td>
<td>?</td>
<td>?</td>
</tr>
<tr>
<td>否</td>
<td>是</td>
<td>是</td>
<td>?</td>
<td>?</td>
</tr>
<tr>
<td>是</td>
<td>是</td>
<td>否</td>
<td>?</td>
<td>X</td>
<td rowspan="3">仅 DSX</td>
</tr>
<tr>
<td>是</td>
<td>否</td>
<td>是</td>
<td>?</td>
<td>X</td>
</tr>
<tr>
<td>是</td>
<td>是</td>
<td>是</td>
<td>?</td>
<td>X</td>
</tr>
<tr>
<td>是</td>
<td>否</td>
<td>否</td>
<td>X</td>
<td>X</td>
<td>DTX &amp; DSX</td>
</tr>
</tbody>
</table>
<p>表 1 – DSX 和 DTX 屏蔽测试结果</p>
</div>
</div>
<div>
<div>
<h4><strong>结论</strong></h4>
<p>布线屏蔽的正确终止是实现系统性能的关键，特别是外来串扰和内部串扰参数方面，但如果有其他布线或建筑接地路径与远程测试仪连接，则并非所有布线测试设备都能识别开路。</p>
<p>Fluke Networks DSX 5000 和 DSX 8000 CableAnalyzers 能够正确地根据 TIA 1152A 2G 级要求沿路径测试布线并检测到故障的距离以更快地排除故障。</p>
</div>
</div>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/fluke-shield.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DSX5000测试报告解释-二部分</title>
		<link>http://www.faxytech.com/archives/fluke-report-2.html</link>
		<comments>http://www.faxytech.com/archives/fluke-report-2.html#comments</comments>
		<pubDate>Mon, 09 Jan 2017 10:30:06 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[fluke报告]]></category>
		<category><![CDATA[测试报告]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8472</guid>
		<description><![CDATA[继续上文（福禄克DSX5000测试报告解读）：本次讲解福禄克报告参数二讲： 报告中紧接蓝色区域的部分为接线图测试和一个框起来的区域，包括被测电缆的关键指标。其中包括长度(以英尺或米... ]]></description>
			<content:encoded><![CDATA[<p>继续<a href="http://www.faxytech.com/archives/dsx5000-report.html">上文（福禄克DSX5000测试报告解读）</a>：本次讲解<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>报告参数二讲：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/01/dsx5000_测试报告样板.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8473" title="fluke dsx5000_测试报告样板" src="http://www.faxytech.com/wp-content/uploads/2017/01/dsx5000_测试报告样板.png" alt="fluke dsx5000_测试报告样板" width="522" height="676" /></a></p>
<p>报告中紧接蓝色区域的部分为接线图测试和一个框起来的区域，包括被测电缆的关键指标。其中包括长度(以英尺或米为单位，取决于用户设置)、传输延迟、延迟偏差、电阻和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>余量。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/01/insert-loss.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8474" title="fluke测试报告，插入损耗" src="http://www.faxytech.com/wp-content/uploads/2017/01/insert-loss.png" alt="fluke测试报告，插入损耗" width="325" height="135" /></a></p>
<p>插入损耗余量的详细信息可从右侧的插入损耗图中查看，包括基于最差条件线对的余量，以及所在的频率和该频率下的限值。</p>
<p><strong>例如</strong>，该报告显示，最差条件插入损耗余量发生在线对4-5、500 MHz，余量为1.8 dB，标准限值43.8 dB，也就是实际<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>是：42.8dB。因为长度是95.7m，衰减还有1.8db余量，那代表线材还可以的。衰减和长度关系很大，线缆越长，衰减悦达。</p>
<p>&nbsp;</p>
<p><strong>详细信息</strong></p>
<p><span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>报告的其他部分列出了最差条件线对的最差条件余量和最差条件值以及所在的频率和详细的图形结果，包括福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>(<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>)、功率和NEXT (<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/psnext-fluke.html" title="PSNEXT">PSNEXT</a></span>)、远端衰减串扰比(<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>)、功率和ACR-F (PSACR-F)、近端衰减串扰比(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span>)、功率和ACR-N (PSACR-N)，以及<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>(RL)。</p>
<p>根据所选限值的不同，测试也可能包括表示平衡和外部串扰的参数，例如横向转换损耗(TCL)、等电平TCTL (ELTCTL)、共模差分NEXT (CDNEXT)和共模回波损耗(CMRL)。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/01/NEXT1.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8477" title="NEXT" src="http://www.faxytech.com/wp-content/uploads/2017/01/NEXT1.png" alt="" width="392" height="192" /></a></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/01/NEXT-quxian.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8476" title="NEXT-quxian" src="http://www.faxytech.com/wp-content/uploads/2017/01/NEXT-quxian.png" alt="" width="434" height="161" /></a></p>
<p><strong>最差条件余量 VS 最差条件数值</strong></p>
<p>无论哪个参数，<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%b5%8b%e8%af%95%e6%8a%a5%e5%91%8a" title="查看 测试报告 的全部文章" target="_blank">测试报告</a></span>都显示DSX5000主机单元(MAIN)和智能远端单元(SR)两者的最差条件余量和数值。两者有何不同？</p>
<p>最差条件余量基于最接近限值的参数值，这是您最需要关注的情况。最差条件数值是参数值最差时的余量，此时参数值最差但不是相对于限值而言的。由于测试仪检测所有线对以及线对组合的最差条件余量和最差条件数值，所以最差条件余量和最差条件数值可能不在同一线对上。然而也可以是相同线对上的相同值。</p>
<p>该报告显示，主机单元的NEXT最差条件余量为6.5 dB，发生在线对3-6和7-8之间，频率为112.0 MHz；而远端单元的最差条件余量为9.4dB，发生在36.0 MHz。从图形中可以看出这两种情况，位于曲线最接近限值处。</p>
<p>&nbsp;</p>
<p><strong>何时判定不合格</strong></p>
<div>当电缆未通过测试时(以及在某种意义上不合格时)，您会在LinkWare报告的右上角看到一个红色的大“X”，测试摘要的结果为“不合格”(FAIL)。幸好，报告也会说明不合格的原因——也用红色表示，您不会遗漏掉的。</div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/fluke-report-2.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DTX-1800和DSX5000对于同轴电缆长度距离定义释义</title>
		<link>http://www.faxytech.com/archives/coax-length.html</link>
		<comments>http://www.faxytech.com/archives/coax-length.html#comments</comments>
		<pubDate>Tue, 30 Aug 2016 00:37:14 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dsx-coax]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[dtx-coax]]></category>
		<category><![CDATA[同轴电缆]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7987</guid>
		<description><![CDATA[我们都知道福禄克DTX-1800和DSX5000可以利用同轴测试模块DTX-COAX或者DSX-COAX，进行同轴电缆测试，那么他们的长度测试原理是什么呢？今天深圳连讯达工程师带大家一起来解读一下。 首先，对同轴... ]]></description>
			<content:encoded><![CDATA[<p>我们都知道<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>和DSX5000可以利用同轴测试模块<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-COAX或者DSX-COAX，进行<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%90%8c%e8%bd%b4%e7%94%b5%e7%bc%86" title="查看 同轴电缆 的全部文章" target="_blank">同轴电缆</a></span>测试，那么他们的长度测试原理是什么呢？今天深圳连讯达工程师带大家一起来解读一下。</p>
<p>首先，对同轴电缆的测试是基于TDR技术，测试结果与性能与同轴电缆的特性<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>密切相关；<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="特性阻抗">特性阻抗</a></span>的测试一般是测试电缆近似的特性阻抗，并非真正意义上的实际<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/trms.html" title="真有效值">真有效值</a></span>，如果在标准规定的范围之内，即可认可是合乎要&#8230;</p>
<p>首先，对同轴电缆的测试是基于TDR技术，测试结果与性能与同轴电缆的特性阻抗密切相关；<br />
特性阻抗的测试一般是测试电缆近似的特性阻抗，并非真正意义上的实际真有效值，如果在标准规定的范围之内，即可认可是合乎要求的，如果超过相关的标准，通过TDR技术大致可以定位出阻抗异常的点；<br />
同轴电缆的测试还有一个重要指标电阻。电阻的测量实际上测试的是电力和端接器的环路电阻，如果末端兵没有接上端接器或者电缆本身就是开路状态，那么电阻值会变为无穷大；反之电缆或端接器短路显示的电阻值近似为0欧姆；当测试的电阻值超过400欧姆，则报告错误；<br />
同轴电缆长度的测试是应该在开路状态下进行测试的，并且末端不允许接有端接器；因为端接器会吸收或者消除信号的反射，所以TDR技术是无法测试出长度参数 的，所以只能在未接端机器的情况下准确测试出同轴电缆的长度。实际测试距离基于不同的特性阻抗和线缆半径，标准中的长度极限值也设置各异，下表中截取了部分标准中关于对长度测量的定义：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/08/coax-length.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7988" title="coax-length" src="http://www.faxytech.com/wp-content/uploads/2016/08/coax-length.gif" alt="" width="800" height="452" /></a></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/coax-length.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DSX5000电缆测试仪系列技术规格书</title>
		<link>http://www.faxytech.com/archives/dsx5000qoi-tech.html</link>
		<comments>http://www.faxytech.com/archives/dsx5000qoi-tech.html#comments</comments>
		<pubDate>Fri, 25 Dec 2015 03:51:57 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[技术规格]]></category>
		<category><![CDATA[招标选型]]></category>
		<category><![CDATA[电缆测试仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7167</guid>
		<description><![CDATA[深圳连讯达公司作为国内最早从事福禄克销售工作的公司，18年来专业为客户提供技术选型，招投标工作。同时为了福禄克中国销售中心，福禄克产品价格优势明显，欢迎咨询！400-688-2580 &#160; ... ]]></description>
			<content:encoded><![CDATA[<p>深圳连讯达公司作为国内最早从事福禄克销售工作的公司，18年来专业为客户提供技术选型，招投标工作。同时为了福禄克中国销售中心，福禄克产品价格优势明显，欢迎咨询！400-688-2580</p>
<p>&nbsp;</p>
<h4><strong>★(<span style="font-family: 宋体;">一</span><span style="font-family: Arial;">)福禄克DSX5000</span><span style="font-family: 宋体;">电缆测试部分</span></strong></h4>
<p>1、?电缆链路测试<span style="font-family: Arial;">(</span><span style="font-family: 宋体;">永久链路</span><span style="font-family: Arial;">/</span><span style="font-family: 宋体;">通道，</span><span style="font-family: Arial;">Cat3/5/5e/6/6A/F</span><span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">FA</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">UTP/FTP/ScTP/STP/</span><span style="font-family: 宋体;">同轴</span><span style="font-family: Arial;">)</span></p>
<p>2、?符合<span style="font-family: Arial;">TIA</span><span style="font-family: 宋体;">标准的外部串扰测试</span></p>
<p>3、?真正符合国际相关布线和测试标准：如<span style="font-family: Arial;">TIA568B</span><span style="font-family: 宋体;">等</span></p>
<p>4、?高可重复性永久链路测试<span style="font-family: Arial;">(</span><span style="font-family: 宋体;">不同时间</span><span style="font-family: Arial;">/</span><span style="font-family: 宋体;">仪器之间的一致性。使用特制永久链路适配器</span><span style="font-family: Arial;">)</span></p>
<p>5、?支持永久链路厂商个性化产品接口测试</p>
<p>6、?快速自动测试<span style="font-family: Arial;">(</span><span style="font-family: 宋体;">完整的双向</span><span style="font-family: Arial;">6A</span><span style="font-family: 宋体;">类双绞线链路自动测试时间</span><span style="font-family: Arial;">10</span><span style="font-family: 宋体;">秒或更少</span><span style="font-family: Arial;">)</span></p>
<p>7、?提供测试数据的管理分析、数据下载和报告生成软件</p>
<p>8、?TCL?<span style="font-family: 宋体;">和</span><span style="font-family: Arial;">ELTCTL </span><span style="font-family: 宋体;">平衡测量，良好的平衡意味着对外部噪声干扰的免疫力更强，满足 </span><span style="font-family: Arial;">TIA</span><span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">ISO</span><span style="font-family: 宋体;">标准要求。</span></p>
<p>9、?高精度的电缆物理故障定位功能<span style="font-family: Arial;">(HDTDX</span><span style="font-family: 宋体;">和</span><span style="font-family: Arial;">HDTDR</span><span style="font-family: 宋体;">技术</span><span style="font-family: Arial;">)</span><span style="font-family: 宋体;">，精确查找串扰和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>异常故障</span></p>
<p>10、?手持式仪表，便于携带和现场使用</p>
<p>11、?全中文智能手机用户操作界面，具有在线操作提示功能，方便新手使用</p>
<p>12、?支持<span style="font-family: Arial;">USB</span><span style="font-family: 宋体;">接口，方便取出数据、配置仪器、编制符合</span><span style="font-family: Arial;">TIA606</span><span style="font-family: 宋体;">标准的电缆标识</span></p>
<p>13、?快速更换模块，适应不同的物理介质测试<span style="font-family: Arial;">(</span><span style="font-family: 宋体;">电缆</span><span style="font-family: Arial;">/</span><span style="font-family: 宋体;">光缆</span><span style="font-family: Arial;">)</span></p>
<p>14、?支持在线<span style="font-family: Arial;">(</span><span style="font-family: 宋体;">有线</span><span style="font-family: Arial;">)</span><span style="font-family: 宋体;">对讲功能，便于合理安排测试进程和工序</span></p>
<p><span style="font-family: 宋体;"><br />
</span></p>
<h4><strong>★(<span style="font-family: 宋体;">二</span><span style="font-family: Arial;">)福禄克DSX5000</span><span style="font-family: 宋体;">光纤测试部分</span></strong></h4>
<p>1、?支持多模、单模；</p>
<p>2、?支持光纤双波长、双光纤、双向测试，支持<span style="font-family: Arial;">A</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">B</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">C</span><span style="font-family: 宋体;">测试模式</span></p>
<p>3、?支持光纤一级测试<span style="font-family: Arial;">(</span><span style="font-family: 宋体;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span></span><span style="font-family: Arial;">/</span><span style="font-family: 宋体;">长度测试，</span><span style="font-family: Arial;">Tier?1</span><span style="font-family: 宋体;">，测试模块为光源</span><span style="font-family: Arial;">/</span><span style="font-family: 宋体;">光功率计一体化设计</span><span style="font-family: Arial;">)</span></p>
<p>4<span style="font-family: 宋体;">、</span><span style="font-family: Arial;">V</span><span style="font-family: 宋体;">级精度</span></p>
<p>a.?支持参数测试?<span style="font-family: Arial;">1?GHz</span></p>
<p>b.?第三方认证</p>
<p>5<span style="font-family: 宋体;">、不平衡电阻测量</span></p>
<p>c.?支持<span style="font-family: Arial;">IEEE?802.3af </span><span style="font-family: 宋体;">和</span><span style="font-family: Arial;">IEEE?802.3at?PoE </span><span style="font-family: 宋体;">检测</span></p>
<p>d.?满足<span style="font-family: Arial;">TIA</span><span style="font-family: 宋体;">、 </span><span style="font-family: Arial;">ISO</span><span style="font-family: 宋体;">和</span><span style="font-family: Arial;">IEEE </span><span style="font-family: 宋体;">等标准要求</span></p>
<p>6、?TCL?<span style="font-family: 宋体;">和</span><span style="font-family: Arial;">ELTCTL </span><span style="font-family: 宋体;">平衡测量</span></p>
<p>e.?良好的平衡意味着对外部噪声干扰的免疫力更强</p>
<p>f.?满足?<span style="font-family: Arial;">TIA</span><span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">ISO</span><span style="font-family: 宋体;">标准要求</span></p>
<p>g.?关键的噪声环境</p>
<p>7、?屏蔽效果测试</p>
<p>h.<span style="font-family: 宋体;">数据中心的机架地导致屏蔽测试误</span><span style="font-family: Arial;">“?PASS”</span></p>
<p>i.<span style="font-family: 宋体;">如果屏蔽层本身开路， </span><span style="font-family: Arial;">Wire?Map(</span><span style="font-family: 宋体;">接线图</span><span style="font-family: Arial;">)</span><span style="font-family: 宋体;">测试结果显示</span><span style="font-family: Arial;">“PASS”</span></p>
<p>j.DSX<span style="font-family: 宋体;">则会报告开路的位置</span></p>
<p>8、?仪器内置项目管理功能</p>
<p>k.<span style="font-family: 宋体;">可以预先配置多个设置不同项目</span></p>
<p>l.<span style="font-family: 宋体;">防止出错，比如选择了错误的极限值</span></p>
<p>m.<span style="font-family: 宋体;">用</span><span style="font-family: Arial;">USB</span><span style="font-family: 宋体;">传递配置给测试仪，也可以用</span><span style="font-family: Arial;">USB</span><span style="font-family: 宋体;">盘传递</span></p>
<p>9、?内建外部串扰测试功能</p>
<p>n.<span style="font-family: 宋体;">支持数据中心的</span><span style="font-family: Arial;">10GBASE-T</span><span style="font-family: 宋体;">链路的外部串扰测试</span></p>
<p>o.<span style="font-family: 宋体;">支持</span><span style="font-family: Arial;">ISO </span><span style="font-family: 宋体;">和</span><span style="font-family: Arial;">TIA</span><span style="font-family: 宋体;">标准</span></p>
<p>10、?CDNEXT?<span style="font-family: 宋体;">测试</span></p>
<p>p.<span style="font-family: 宋体;">共模</span><span style="font-family: Arial;">-</span><span style="font-family: 宋体;">差模</span><span style="font-family: Arial;"><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span></span><span style="font-family: 宋体;">测量</span></p>
<p>q.<span style="font-family: 宋体;">外部串扰问题的诊断工具</span></p>
<p>11、?存储超过<span style="font-family: Arial;">10,000 </span><span style="font-family: 宋体;">个测试结果</span></p>
<p>r.Cat6A/Class?EA<span style="font-family: 宋体;">测试结果含曲线数据和诊断数据</span></p>
<p>12、?NEXT?<span style="font-family: 宋体;">和</span><span style="font-family: Arial;">RL </span><span style="font-family: 宋体;">诊断</span></p>
<p>s.HDTDR?<span style="font-family: 宋体;">可定位阻抗异常</span><span style="font-family: Arial;">– </span><span style="font-family: 宋体;">并存储输出结果 </span></p>
<p>t.HDTDX?<span style="font-family: 宋体;">可定位串扰问题 </span><span style="font-family: Arial;">– </span><span style="font-family: 宋体;">并存储输出结果</span></p>
<p>13、?满足环通量<span style="font-family: Arial;">(EF)</span><span style="font-family: 宋体;">测试要求</span></p>
<p>u.光源符合<span style="font-family: Arial;">EF</span><span style="font-family: 宋体;">要求</span></p>
<p>v.<span style="font-family: 宋体;">匹配的测试参考跳线</span><span style="font-family: Arial;">(</span><span style="font-family: 宋体;">符合</span><span style="font-family: Arial;">TIA?TSB-4979</span><span style="font-family: 宋体;">标准要求</span><span style="font-family: Arial;">) </span></p>
<p>w.ANSI/TIA-526-14-B?<span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">IEC?61280-4-2</span><span style="font-family: 宋体;">要求</span><span style="font-family: Arial;">EF</span><span style="font-family: 宋体;">测试</span></p>
<p>x.<span style="font-family: 宋体;">线缆供应商</span><span style="font-family: Arial;">/</span><span style="font-family: 宋体;">制造商开始要求</span><span style="font-family: Arial;">EF</span><span style="font-family: 宋体;">测试</span><span style="font-family: Arial;">(</span><span style="font-family: 宋体;">质保前提</span><span style="font-family: Arial;">)</span></p>
<p>14、?3?<span style="font-family: 宋体;">秒完成自动测试</span></p>
<p>y.850?nm?<span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">1300?nm</span><span style="font-family: 宋体;">多模双光纤测试</span></p>
<p>z.1310?nm?<span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">1550?nm </span><span style="font-family: 宋体;">单模双光纤测试</span></p>
<p>15、??跟跳线基准设置<span style="font-family: Arial;">(SC</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">LC</span><span style="font-family: 宋体;">、 </span><span style="font-family: Arial;">ST </span><span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">FC</span><span style="font-family: 宋体;">连接器</span><span style="font-family: Arial;">)</span></p>
<p>aa.<span style="font-family: 宋体;">光缆质保要求使用</span><span style="font-family: Arial;">1</span><span style="font-family: 宋体;">根跳线设置参考值</span></p>
<p>ab.<span style="font-family: 宋体;">要求光功率计端口是可更换的</span></p>
<p>16、?测试参考跳线验证鉴定</p>
<p>ac.<span style="font-family: 宋体;">内建图形化参考设置引导流程</span></p>
<p>ad.<span style="font-family: 宋体;">包含测试参考跳线</span><span style="font-family: Arial;">(TRCs)</span><span style="font-family: 宋体;">的检定图示流程</span></p>
<p>ae.TRC?<span style="font-family: 宋体;">检定结果自动保存</span></p>
<p>17、?内置可是故障定位仪<span style="font-family: Arial;">(VFL)</span></p>
<p>af.<span style="font-family: 宋体;">定位光纤过度弯曲和机架连接部位的破损问题</span></p>
<p>ag.<span style="font-family: 宋体;">验证光纤极性</span></p>
<p>18、?Quad<span style="font-family: 宋体;">光纤测试模快</span></p>
<p>ah.<span style="font-family: 宋体;">双端口光源</span><span style="font-family: Arial;">(850/1300?nm </span><span style="font-family: 宋体;">端口和 </span><span style="font-family: Arial;">1310/1550?nm</span><span style="font-family: 宋体;">端口</span><span style="font-family: Arial;">)</span></p>
<p>ai.<span style="font-family: 宋体;">输入端口</span><span style="font-family: Arial;">4</span><span style="font-family: 宋体;">波长<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span></span><span style="font-family: Arial;">(850?nm</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">1300?nm</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">1310?nm </span><span style="font-family: 宋体;">和</span><span style="font-family: Arial;">1550?nm)</span></p>
<p>19、?一次存储两根光纤结果</p>
<p>aj.<span style="font-family: 宋体;">远端单元的测试结果自动发送到主机并进行分析和结果保存</span></p>
<p>20、?内置对讲机<span style="font-family: Arial;">(</span><span style="font-family: 宋体;">有线</span><span style="font-family: Arial;">)</span></p>
<p>ak.<span style="font-family: 宋体;">通过单多模光纤进行全双工对讲</span></p>
<p>21、?结果管理</p>
<p>al.<span style="font-family: 宋体;">测试结果统计分析</span></p>
<p>am.<span style="font-family: 宋体;">合并与一体的</span><span style="font-family: Arial;">OLTS</span><span style="font-family: 宋体;">、光纤端面检查结果</span></p>
<p>an.<span style="font-family: 宋体;">内置</span><span style="font-family: Arial;">PDF</span><span style="font-family: 宋体;">输出功能</span></p>
<p><span style="font-family: 宋体;"><br />
</span></p>
<h4><strong>★（三）福禄克DSX5000规格要求</strong></h4>
<p>1<span style="font-family: 宋体;">、屏蔽和非屏蔽的双绞 </span><span style="font-family: Arial;">LAN </span><span style="font-family: 宋体;">布线： </span><span style="font-family: Arial;">TIA </span><span style="font-family: 宋体;">类别</span><span style="font-family: Arial;">3</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">4</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">5</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">5e</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">6</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">6A</span><span style="font-family: 宋体;">：</span><span style="font-family: Arial;">100?Ω?ISO/IEC?Class?C</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">D</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">E</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">EA</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">F </span><span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">FA</span><span style="font-family: 宋体;">：</span><span style="font-family: Arial;">100? </span><span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">120? </span></p>
<p>2<span style="font-family: 宋体;">、标准链路接口适配器，</span><span style="font-family: Arial;">USB</span><span style="font-family: 宋体;">视频检查探头、一键式清洁器 </span></p>
<p>3<span style="font-family: 宋体;">、久链路适配器?插头类型：屏蔽的 </span><span style="font-family: Arial;">RJ45</span></p>
<p>4<span style="font-family: 宋体;">、通道适配器?插座类型：屏蔽的 </span><span style="font-family: Arial;">RJ45</span></p>
<p>5<span style="font-family: 宋体;">、功率表规格 </span></p>
<p>6<span style="font-family: 宋体;">、输入连接器?可互换的接头适配器 </span><span style="font-family: Arial;">LC </span></p>
<p>7<span style="font-family: 宋体;">、探测器类型 </span><span style="font-family: Arial;">InGaAs </span></p>
<p>8<span style="font-family: 宋体;">、波长 </span><span style="font-family: Arial;">850?nm</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">1300?nm</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">1310?nm</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">1550?nm </span></p>
<p>9<span style="font-family: 宋体;">、功率测量范围 </span><span style="font-family: Arial;">0?dBm </span><span style="font-family: 宋体;">至 </span><span style="font-family: Arial;">-65?dBm?(850?nm)?0?dBm </span><span style="font-family: 宋体;">至 </span><span style="font-family: Arial;">-70?dBm</span><span style="font-family: 宋体;">（所有其他波长） </span></p>
<p>10<span style="font-family: 宋体;">、功率测量的不确定性</span><span style="font-family: Arial;">1,2?&lt;?+/-?5%?+/-?32?pW </span></p>
<p>11<span style="font-family: 宋体;">、测量的线性度</span><span style="font-family: Arial;">3?&lt;?±?0.1?dB </span></p>
<p>12<span style="font-family: 宋体;">、校准周期?一年 </span></p>
<p>13<span style="font-family: 宋体;">、测试速度（不包括参考设置时间）</span></p>
<p>智能远端模式：<span style="font-family: Arial;">&lt;?3 </span><span style="font-family: 宋体;">秒?（</span><span style="font-family: Arial;">2 </span><span style="font-family: 宋体;">波长，单向，自动波长检测）</span></p>
<p>远端信号源模式：<span style="font-family: Arial;">≤?2 </span><span style="font-family: 宋体;">秒?（</span><span style="font-family: Arial;">2 </span><span style="font-family: 宋体;">波长，单向，自动波长检测）</span></p>
<p>环回模式：<span style="font-family: Arial;">≤?2 </span><span style="font-family: 宋体;">秒?（</span><span style="font-family: Arial;">2 </span><span style="font-family: 宋体;">波长，单向，自动波长检测）</span></p>
<p>14<span style="font-family: 宋体;">、输入</span><span style="font-family: Arial;">/</span><span style="font-family: 宋体;">输出连接器?可互换的接头适配器 </span><span style="font-family: Arial;">LC </span><span style="font-family: 宋体;">标准</span></p>
<p>15<span style="font-family: 宋体;">、发射条件??符合 </span><span style="font-family: Arial;">TIA-526-14-B</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">ISO/IEC?14763-3 </span><span style="font-family: 宋体;">和 </span><span style="font-family: Arial;">IEC?61280-4-1 </span><span style="font-family: 宋体;">合规性要求的环通量</span></p>
<p>16<span style="font-family: 宋体;">、所测光纤类型 </span><span style="font-family: Arial;">50/125??m </span><span style="font-family: 宋体;">或 </span><span style="font-family: Arial;">62.5/125??m</span><span style="font-family: 宋体;">、?单模 </span></p>
<p>17<span style="font-family: 宋体;">、光源类型和波长</span></p>
<p>LED?<span style="font-family: 宋体;">光源 </span><span style="font-family: Arial;">850?nm?±?30?nm?1300?nm?±?20?nm </span></p>
<p>Fabry-Perot?<span style="font-family: 宋体;">激光二极管 </span><span style="font-family: Arial;">1310?nm?±?20?nm?1550?nm?±?30?nm </span></p>
<p>18<span style="font-family: 宋体;">、最大测量长度???多模</span><span style="font-family: Arial;">12?km</span><span style="font-family: 宋体;">、单模 </span><span style="font-family: Arial;">130?km </span></p>
<p>19<span style="font-family: 宋体;">、长度测量的准确性 </span><span style="font-family: Arial;">±?1.5?m?± </span><span style="font-family: 宋体;">长度的 </span><span style="font-family: Arial;">1?% </span></p>
<p>20<span style="font-family: 宋体;">、输出功率（额定）?多模</span><span style="font-family: Arial;">≥?-24?dBm</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">EF-TRC</span><span style="font-family: 宋体;">；单模 </span><span style="font-family: Arial;">≥?-4?dBm </span></p>
<p>21<span style="font-family: 宋体;">、输出功率稳定性 </span><span style="font-family: Arial;">8 </span><span style="font-family: 宋体;">小时内 </span><span style="font-family: Arial;">±?0.05?dB</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">15</span><span style="font-family: 宋体;">分钟内 </span><span style="font-family: Arial;">±?0.03?dB?8 </span><span style="font-family: 宋体;">；</span></p>
<p>22<span style="font-family: 宋体;">、损耗</span><span style="font-family: Arial;">/</span><span style="font-family: 宋体;">长度规格?光源波长 </span><span style="font-family: Arial;">850?nm</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">1300?nm</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">1310?nm</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">1550?nm </span></p>
<p>23<span style="font-family: 宋体;">、功率测量范围 </span><span style="font-family: Arial;">0?dBm </span><span style="font-family: 宋体;">至 </span><span style="font-family: Arial;">-65?dBm?(850?nm)?0?dBm </span><span style="font-family: 宋体;">至 </span><span style="font-family: Arial;">-70?dBm</span><span style="font-family: 宋体;">（所有其他波长） </span></p>
<p>24<span style="font-family: 宋体;">、功率测量的不确定性</span><span style="font-family: Arial;">1</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">2?&lt;?+/-?5%?+/-?32?pW </span></p>
<p>25<span style="font-family: 宋体;">、测量的线性度</span><span style="font-family: Arial;">3?&lt;?±?0.1?dB </span></p>
<p>26<span style="font-family: 宋体;">、自动测试速度 </span><span style="font-family: Arial;">5e </span><span style="font-family: 宋体;">或 </span><span style="font-family: Arial;">6 </span><span style="font-family: 宋体;">类</span><span style="font-family: Arial;">/Class?D </span><span style="font-family: 宋体;">或 </span><span style="font-family: Arial;">E </span><span style="font-family: 宋体;">的全双向自动测试：</span><span style="font-family: Arial;">9 </span><span style="font-family: 宋体;">秒。完整的双向 </span><span style="font-family: Arial;">6A </span><span style="font-family: 宋体;">类 </span><span style="font-family: Arial;">EA </span><span style="font-family: 宋体;">级自动测试：</span><span style="font-family: Arial;">10 </span><span style="font-family: 宋体;">秒</span><span style="font-family: Arial;">, </span><span style="font-family: 宋体;">支持测试参数（测试参数的数量及测试的频率范围由所选择的测试标准决定）?接线图、长度、传播延迟、延迟偏差、直流回路电阻、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>（衰减）、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span> </span><span style="font-family: Arial;">(RL)</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">NEXT</span><span style="font-family: 宋体;">、衰减串扰比 </span><span style="font-family: Arial;">(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span>)</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;"><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>?(ELFEXT)</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">PS?ACR-F?(ELFEXT)</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">PS?NEXT</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">PS?ACR-N</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">PS?Alien?Near?End?Xtalk?(PS?ANEXT)</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">PS?Alien?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="Attenuation">Attenuation</a></span>?Xtalk?Ratio?Far?End?(PS?AACR-F)?, </span><span style="font-family: 宋体;">输入保护?能经受持续的电话电压和 </span><span style="font-family: Arial;">100?mA </span><span style="font-family: 宋体;">的过流。在 </span><span style="font-family: Arial;">ISDN </span><span style="font-family: 宋体;">上偶尔发生超压现象不会造成损坏</span></p>
<p>27<span style="font-family: 宋体;">、</span><span style="font-family: Arial;">6A </span><span style="font-family: 宋体;">类</span><span style="font-family: Arial;">/?EA</span><span style="font-family: 宋体;">级测试模式（或更低链路类别）?<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="线缆认证分析仪">线缆认证分析仪</a></span>模块超越 </span><span style="font-family: Arial;">TIA?1152</span><span style="font-family: 宋体;">标准的 </span><span style="font-family: Arial;">IIIe </span><span style="font-family: 宋体;">级要求以及 </span><span style="font-family: Arial;">IEC?61935-1 </span><span style="font-family: 宋体;">的 </span><span style="font-family: Arial;">IV </span><span style="font-family: 宋体;">级要求。 </span></p>
<p>FA?<span style="font-family: 宋体;">级测试模式?线缆认证分析仪模块超越 </span><span style="font-family: Arial;">IEC?61935-1 </span><span style="font-family: 宋体;">第四版草案中的 </span><span style="font-family: Arial;">V </span><span style="font-family: 宋体;">级要求。 </span></p>
<p>28<span style="font-family: 宋体;">、范围 </span><span style="font-family: Arial;">800?m?(2600?ft)?150?m?(490?ft) </span><span style="font-family: 宋体;">分辨率 </span><span style="font-family: Arial;">0.1?m </span><span style="font-family: 宋体;">或者 </span><span style="font-family: Arial;">1?ft?0.1?m </span><span style="font-family: 宋体;">或者 </span><span style="font-family: Arial;">1?ft</span><span style="font-family: 宋体;">，精度 </span><span style="font-family: Arial;">±?(0.3?m?+?2?%)</span><span style="font-family: 宋体;">；</span><span style="font-family: Arial;">0?m </span><span style="font-family: 宋体;">至 </span><span style="font-family: Arial;">150?m</span></p>
<p>29<span style="font-family: 宋体;">、范围 </span><span style="font-family: Arial;">4000?ns?750?ns</span><span style="font-family: 宋体;">，分辨率 </span><span style="font-family: Arial;">1?ns?1?ns</span><span style="font-family: 宋体;">，精度 </span><span style="font-family: Arial;">±?(2?ns?+?2?%)</span><span style="font-family: 宋体;">；</span><span style="font-family: Arial;">0?ns </span><span style="font-family: 宋体;">至 </span><span style="font-family: Arial;">750?ns</span></p>
<p>30<span style="font-family: 宋体;">、过载恢复时间?过电压后 </span><span style="font-family: Arial;">10 </span><span style="font-family: 宋体;">分钟内恢复额定精度。重复或长期过压之后需要重新设置基准。</span></p>
<p>31<span style="font-family: 宋体;">、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/resistance.html" title="直流环路电阻">直流环路电阻</a></span>测试?范围 </span><span style="font-family: Arial;">0?Ω </span><span style="font-family: 宋体;">至 </span><span style="font-family: Arial;">540?Ω?,</span><span style="font-family: 宋体;">分辨率 </span><span style="font-family: Arial;">0.1?Ω?,</span><span style="font-family: 宋体;">精度 </span><span style="font-family: Arial;">±?(1?Ω?+?1?%)</span></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx5000qoi-tech.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【江西南昌】福禄克FLuke DSX5000+1T-1500-2pk+OFP-100-Q铜缆光纤网络智能建筑解决方案</title>
		<link>http://www.faxytech.com/archives/jx-fluke.html</link>
		<comments>http://www.faxytech.com/archives/jx-fluke.html#comments</comments>
		<pubDate>Fri, 08 May 2015 01:31:38 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[客户案例]]></category>
		<category><![CDATA[新闻资讯]]></category>
		<category><![CDATA[1T-1500-2PK]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[GB 50312-2007]]></category>
		<category><![CDATA[GB50339]]></category>
		<category><![CDATA[GBT21671-2008]]></category>
		<category><![CDATA[OFP-100-Q]]></category>
		<category><![CDATA[南昌fluke]]></category>
		<category><![CDATA[智能建筑检测]]></category>
		<category><![CDATA[江西福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6132</guid>
		<description><![CDATA[【江西南昌】福禄克FLuke DSX5000+1T-1500-2pk+OFP-100-Q铜缆光纤网络智能建筑解决方案 ?- 南昌市建筑工程质量检测中心是由福禄克中国销售中心深圳市连讯达电子技术开发有限公司提供解决方案。 南... ]]></description>
			<content:encoded><![CDATA[<p>【江西南昌】福禄克FLuke DSX5000+<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/onetouch-at.html" title="福禄克Fluke 1T-1500">1T-1500</a></span>-2pk+<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>光纤网络智能建筑解决方案 ?- 南昌市建筑工程质量检测中心是由福禄克中国销售中心深圳市连讯达电子技术开发有限公司提供解决方案。</p>
<p>南昌市建筑工程质量检测中心新开始<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%99%ba%e8%83%bd%e5%bb%ba%e7%ad%91%e6%a3%80%e6%b5%8b" title="查看 智能建筑检测 的全部文章" target="_blank">智能建筑检测</a></span>，需要一套系统的检测设备，特咨询测试解决方案专家连讯达上门提供产品演示和方案设计，并且最终完成设备采购。本次南昌市建筑工程质量检测中心采用的是福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="线缆认证分析仪">线缆认证分析仪</a></span>专注网线的质量检测。严格按照国家<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="综合布线">综合布线</a></span>验收标准<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/gb-50312-2007" title="查看 GB 50312-2007 的全部文章" target="_blank">GB 50312-2007</a></span>和GB 50339进行质量测试。网络设备验收采用的是福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/1t-1500-2pk.html" title="福禄克Fluke 1T-1500-2PK">1T-1500-2PK</a></span>实现国家以太网标准GB/T21671-2008和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/gb50339" title="查看 GB50339 的全部文章" target="_blank">GB50339</a></span>国家以太网验收标准进行测试验收。光纤采用的是<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ofp-100-q" title="查看 OFP-100-Q 的全部文章" target="_blank">OFP-100-Q</a></span>实现光纤的二级认证。完美解决质量建筑综合布线和以太网验收方案。需了解详情：0755-83999818。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/05/jx-fluke1.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-6133" title="fluke案例中心南昌市建筑工程质量检测中心" src="http://www.faxytech.com/wp-content/uploads/2015/05/jx-fluke1.jpg" alt="" width="600" height="450" /></a></p>
<p>南昌市建筑工程质量检测中心办公服务大楼外景</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/05/fluke-jx-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-6134" title="南昌市建筑质量检测中心logo" src="http://www.faxytech.com/wp-content/uploads/2015/05/fluke-jx-2.jpg" alt="" width="600" height="450" /></a></p>
<p>南昌市建筑工程质量检测中心标识墙</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/05/fluke-jx-3.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-6135" title="福禄克FLuke DSX5000+1T-1500-2pk+OFP-100-Q铜缆光纤网络智能建筑解决方案 " src="http://www.faxytech.com/wp-content/uploads/2015/05/fluke-jx-3.jpg" alt="" width="600" height="450" /></a></p>
<p>福禄克铜缆光纤网络智能建筑解决方案图片</p>
<p>&nbsp;</p>
<p>南昌市建筑工程质量检测中心简介：南昌市建筑科学研究所（南昌市建筑工程质量检测中心）是一家专业从事建设工程材料、构件检测，建设工程结构检测，钢结构检测，桩基及地基基础检测，建筑门窗检测、建筑节能检测、设备安装检测、智能建筑检测及室内空气环境检测的科研技术服务机构。公司技术力量雄厚，检测门类齐全，拥有江西省建设厅颁发的建筑工程检测资质。所有检测项目均通过江西省质量技术监督局<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克计量">计量</a></span>认证。同时我中心一直积极开展科研项目并取得一定成效。</p>
<p>南昌市建筑工程质量监督站属编委注册的独立法人单位,隶属于南昌市城乡建设委员会。本中心拥有固定资产800多万元，建筑面积2600平方米，实验工作面积1600平方米。下设五个检测室（中心实验室、桩基检测室、结构检测室、道桥检测室、环境检测室），每个科室设立了一名质量监督员，负责质量监督工作。单位现有专业检测技术人员53名，其中具有中、高级专业技术职称人员28名；拥有各类高、精仪器设备263台套，是同行业省内规模最大的检测单位之一。本单位用于检测的仪器、设备、计量器具，均按计量法和计量认证工作要求进行定期检定或校验合格。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/jx-fluke.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>18年感恩回馈！购福禄克DSX5000等测试仪送精美礼品！</title>
		<link>http://www.faxytech.com/archives/18year-promotion.html</link>
		<comments>http://www.faxytech.com/archives/18year-promotion.html#comments</comments>
		<pubDate>Tue, 24 Mar 2015 10:30:20 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[新闻资讯]]></category>
		<category><![CDATA[18年感恩回馈]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[深圳连讯达]]></category>
		<category><![CDATA[精美礼品]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=5964</guid>
		<description><![CDATA[深圳市连讯达电子技术开发有限公司18周年感恩回馈-购买福禄克测试仪就可以获赠超精美礼品！ 致：连讯达用户 尊敬的连讯达用户，深圳市连讯达电子技术开发有限公司于2015年03月24日起掀开... ]]></description>
			<content:encoded><![CDATA[<p>深圳市连讯达电子技术开发有限公司18周年感恩回馈-购买福禄克测试仪就可以获赠超<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%b2%be%e7%be%8e%e7%a4%bc%e5%93%81" title="查看 精美礼品 的全部文章" target="_blank">精美礼品</a></span>！</p>
<p><strong>致：连讯达用户</strong><br />
尊敬的连讯达用户，深圳市连讯达电子技术开发有限公司于2015年03月24日起掀开了一波针对<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%b7%b1%e5%9c%b3%e8%bf%9e%e8%ae%af%e8%be%be" title="查看 深圳连讯达 的全部文章" target="_blank">深圳连讯达</a></span>18周年福禄克测试仪促销活动，以回馈深圳连讯达的广大用户。活动期间购买福禄克测试仪器以下型号，就有机会获得福禄克豪华原装便携包、Ipad mini、CASIO手表?、?美容仪、富光水杯等精美礼品。 ?希望大家踊跃参加！</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/03/lipin.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5965" title="福禄克网络测试仪优惠促销" src="http://www.faxytech.com/wp-content/uploads/2015/03/lipin.jpg" alt="" width="614" height="240" /></a></p>
<p>具体办法如下：</p>
<ul>
<li><strong>1、购买福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/aircheck-wifi-tester.html" title="福禄克Fluke Aircheck">Aircheck</a></span>-Faxy，<span class='wp_keywordlink'><a href="	http://www.faxytech.com/archives/linkrunner-at.html" title="福禄克FLuke LRAT-2000">LRAT-2000</a></span>-Faxy可获得福禄克原装原厂豪华便携包一个。</strong></li>
<li><strong>2、购买福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>-Faxy，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span>-Faxy 、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> PRO-Faxy送CASIO手表手表一只。</strong></li>
<li><strong>3、购买福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/mt-8200-60-kit.html" title="福禄克FLuke MT-8200-60-KIT 寻线器">MT-8200-60-KIT</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/microscanner2.html" title="福禄克Microscanner2">MS2-100</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/linkrunner-pro.html" title="福禄克FLUKE链路通测试仪">LRPRO</a></span>-1000任意型号3个。送富光精美水杯一个。</strong></li>
<li><strong>4、其中福禄克EtherSope经典测试仪<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/etherscope-2.html" title="福禄克FLUKE ES网络通二代">ES2-PRO</a></span><strong>-Faxy</strong>，可以任选礼品。</strong></li>
</ul>
<p>&nbsp;</p>
<p>还等什么？立即致电了解吧：400-688-2580</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/18year-promotion.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DSX5000功能展示：直流电阻不平衡测试：为您的 PoE 系统提供简单而经济的保证</title>
		<link>http://www.faxytech.com/archives/dsx5000-poe.html</link>
		<comments>http://www.faxytech.com/archives/dsx5000-poe.html#comments</comments>
		<pubDate>Fri, 13 Mar 2015 01:45:07 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dsx5000]]></category>
		<category><![CDATA[PoE]]></category>
		<category><![CDATA[不平衡测试]]></category>
		<category><![CDATA[直流电阻]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=5862</guid>
		<description><![CDATA[虽然 10/100BASE-T（即 10 和 100 Mbps）应用只需要两根双绞线进行传输，剩下一根四对绞线中的两根备用的双绞线供 PoE 使用，但千兆以太网需要所有四根双绞线才能进行双向传输。在这种情况下，P... ]]></description>
			<content:encoded><![CDATA[<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">虽然 10/100BASE-T（即 10 和 100 Mbps）应用只需要两根双绞线进行传输，剩下一根四对绞线中的两根备用的双绞线供 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/poe" title="查看 PoE 的全部文章" target="_blank">PoE</a></span> 使用，但千兆以太网需要所有四根双绞线才能进行双向传输。在这种情况下，PoE 通过同时传输数据的双绞线实现。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">这通常称为幻像供电，实现方式是在一根四对以太网线缆的两根双绞线之间施加一个共模电压，PoE 不能干扰数据传输。但是，PoE 连接中的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%9b%b4%e6%b5%81%e7%94%b5%e9%98%bb" title="查看 直流电阻 的全部文章" target="_blank">直流电阻</a></span>不平衡可能会产生严重问题。虽然 TIA 性能现场测试中并不要求进行电阻<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e4%b8%8d%e5%b9%b3%e8%a1%a1%e6%b5%8b%e8%af%95" title="查看 不平衡测试 的全部文章" target="_blank">不平衡测试</a></span>，但 IEEE 的 PoE 标准中指定了该测试，而为了保证设备获得所需的电力和数据，还需要很多努力使该测试成为现场测试要求。</p>
<p class="DS_Headline" _mce_style="font-size: 1.2em; font-weight: bold; color: #293f6a; vertical-align: top; line-height: 1.4em; word-spacing: normal; margin-bottom: 2px; padding-top: 0px; margin-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; white-space: normal; word-spacing: normal; font-size: 1.2em; font-weight: bold; color: rgb(41, 63, 106); vertical-align: top; line-height: 1.4em; margin-bottom: 2px; padding-top: 0px; margin-top: 0px;">了解 PoE 和直流电阻不平衡</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">IEEE 802.3af PoE 标准是为了通过双绞数据线为设备提供远程低电压而开发的。电力通过电源设备 (PSE) 注入，这通常是一种启用了 PoE 的开关或一种中跨电力设备。电力可由另一端的多种用电设备 (PD) 使用，包括语音电话、无线接入点 (WAP)、挂钟、传感器、摄像机、访问控制面板等。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">原始 IEEE 802.3af 标准通过双绞线最高可提供 15.4 W（13 W 可用）功率，而最新的 IEEE 802.3at PoE Plus 标准将最大功率值提高到 30 W（25.5 W 可用）。PoE Plus 是为需要更高功率的设备而开发的，如较高功率 WAP、泛倾斜变焦照相机、LED 显示屏等。实际上，为实现更复杂的信号处理和需要 PoE Plus 的更高帧速率，最新的 802.11ac 千兆 WiFi 标准有更高的功率要求。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">IEEE 标准为 PSE 指定了两种使用一根四对数据线缆中的两根双绞线来提供电力的方法—方法 A 和 B。在方法 B 中，电力是通过备用双绞线使用双绞线 1 和 4 提供的。这与仅使用两根双绞线（双绞线 2 和 3）的数据信号兼容，包括 10/100BASE-T 应用。在方法 A 中，电力与数据同时通过双绞线 2 和 3 提供，兼容两对和四对应用，包括 10/100BASE-T 和 1000BASE-T。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">在方法 A 中，电力通过应用共模电压经数据线对传输。电力通过 PD 变压器的中心分路器接收和返回，拆分双绞线中各导线之间的电流。双绞线中每条线的电阻相等时，直流电阻不平衡（两导线之间的电阻差）为零，电流均分，即为共模电流。</p>
<p style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 13px; line-height: 19px; white-space: normal;"><img _mce_style="width: 650px; height: 250px;" src="http://www.faxytech.com/wp-content/plugins/ueditor/ueditor/php/upload/7451426217859.jpg" _mce_src="http://www.faxytech.com/wp-content/plugins/ueditor/ueditor/php/upload/83011426217786.jpg" border="0" alt="" hspace="0" vspace="0" width="650" height="250" style="border: 0px; width: 650px; height: 250px;"/></p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">虽然设备可以承受轻微的直流电阻不平衡，但过大的不平衡可能导致变压器饱和。这最终会使以太网数据信号的波形变形，导致位错误、重复传输，甚至数据链路故障。</p>
<p class="DS_Headline" _mce_style="font-size: 1.2em; font-weight: bold; color: #293f6a; vertical-align: top; line-height: 1.4em; word-spacing: normal; margin-bottom: 2px; padding-top: 0px; margin-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; white-space: normal; word-spacing: normal; font-size: 1.2em; font-weight: bold; color: rgb(41, 63, 106); vertical-align: top; line-height: 1.4em; margin-bottom: 2px; padding-top: 0px; margin-top: 0px;">什么导致直流电阻不平衡？</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">可因多种原因在 PoE 数据链路中发生直流电阻不平衡。虽然 PSE 和终端设备都可能会发生中心分路器偏移之类的变压器问题，但直流电阻不平衡更经常是因为工艺差、端子不一致和线缆质量不达标引起的。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">长期以来，不良安装实践一直是网络性能问题的关键。保证最小弯曲半径和保持对绞靠近端点是实现性能参数的关键，对于 1000BASE-T 等较高频率应用更是如此。相对高频率传输特性来说 PoE 更依赖于特定长度线缆的直流电阻，因而某些安装实践会产生影响。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">各个导线终端的一致性对于避免直流电阻不平衡有重要意义。将各个导线压到网络插座中正确的 IDC 塔中以去除导线绝缘、露出铜，然后完成连接。在该实践过程中保持正确且一致的安插并不一定是件容易的事。插入导线需要一定的力度，不熟练、手部疲劳和较大的导线尺寸都会对一致性产生影响。当一对 PoE 线中的两根导线终端不一致时，就会发生直流电阻不平衡。使用正确的终端工具有助于提高 PoE 系统中终端的一致性并避免直流电阻不平衡（见侧栏上的终端工具）。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">除合格的终端外，还要有精密的制造流程，因为线缆和连接的整体质量也会影响直流电阻不平衡。制造高质量 UTP 线缆时需要仔细选择铜导线并通过严格的控制措施保持线缆的正确外形。如果低质量线缆的铜导线在直径、同心度（圆度）、轮廓和平滑度上出现差异，则 PoE 系统中出现直流电阻不平衡的可能性就会更高。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">目前业界越来越关心的一个问题就是有大量含铜镀铝 (CCA)、铜镀钢和其他非标准导线冒充 5e 类甚至 6 类线。虽然这些双绞线于那些寻找经济型网络解决方案的人很有吸引力，但 CCA 线不符合行业标准，也不支持 PoE 应用，因为它们的直流电阻较大，会比相同直径的实心铜导线高 55%。线的电阻越高发热就越大，所驱动设备获得的电压就越小。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">遗憾的是，测试直流电阻并不足以确定是否支持 PoE，因为部分 CCA 线在短链路中可以通过<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/resistance.html" title="直流环路电阻">直流环路电阻</a></span>测试。但是，无论链路长度如何，CCA 线的双绞线通常都会有直流电阻不平衡，因为它们导线之间缺乏一致性（见侧栏上直流环路电阻和直流电阻不平衡）。关于 CCA 线缆还有一些其他问题—它们的安装是非法的，达不到国家电气规范消防安全评级，因而违规并更容易引起火灾。</p>
<p class="DS_Headline" _mce_style="font-size: 1.2em; font-weight: bold; color: #293f6a; vertical-align: top; line-height: 1.4em; word-spacing: normal; margin-bottom: 2px; padding-top: 0px; margin-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; white-space: normal; word-spacing: normal; font-size: 1.2em; font-weight: bold; color: rgb(41, 63, 106); vertical-align: top; line-height: 1.4em; margin-bottom: 2px; padding-top: 0px; margin-top: 0px;">直流电阻不平衡测试</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">IEEE 标准 802.3-2012 规定导线之间的直流电阻不平衡最高为 3%，这意味着两根导线之间的直流电阻差不能超过一根双绞线总直流环路电阻的 3%。但是 TIA 和 IEC 标准都不要求将直流电阻不平衡作为现场测量。没有现场测试要求是因为没有能够测试直流电阻不平衡的现场测试仪，于是这最终成了仅实验室可以执行的测量。但有了 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span> CableAnalyzer 情况就不同了。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">直流电阻不平衡测试可以验证双绞线中的两根导线有相同的电阻，从而提供所需的共模电流以有效地支持 PoE 并避免同一双绞线上传输的数据信号发生失真。与仅测试直流环路电阻的其他现场测试仪不同，DSX-5000 可同时测量直流环路电阻和直流电阻不平衡。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">另外如下面的图 1 所示，DSX-5000 测量的直流环路电阻是一根双绞线中的两根导线的电阻和，而直流电阻不平衡测量的是两根导线的电阻差。</p>
<p style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 13px; line-height: 19px; white-space: normal;"><img _mce_style="width: 630px; height: 339px;" src="http://www.faxytech.com/wp-content/plugins/ueditor/ueditor/php/upload/18821426217859.jpg" _mce_src="http://www.faxytech.com/wp-content/plugins/ueditor/ueditor/php/upload/88381426217786.jpg" border="0" alt="" hspace="0" vspace="0" width="630" height="339" style="border: 0px; width: 630px; height: 339px;"/></p>
<p class="DS_Captions" _mce_style="font-size: 11px; font-style: italic; margin-top: 0px; margin-bottom: 20px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; line-height: 19px; white-space: normal; font-size: 11px; font-style: italic; margin-top: 0px; margin-bottom: 20px; padding-top: 0px;">图 1</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">虽然现场测试不要求，但 TIA 和 ISO/IEC 标准中均包含电阻不平衡测试极限（值），只是 TIA 标准仅为通道提供这些极限（值），如下面表 1 所示。</p>
<table cellpadding="5" width="100%" class="mceItemTable">
<tbody _mce_style="border: none;" style="border: none;">
<tr class="DS_Table_Header_Row" _mce_style="font-weight: bold; color: #ffffff; background-color: #293f6a; padding: 2px;" style="font-weight: bold; color: rgb(255, 255, 255); background-color: rgb(41, 63, 106); padding: 2px;">
<td rowspan="2" style="color: rgb(0, 0, 0); font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">DSX CableAnalyzer 测试极限名称</td>
<td colspan="2" style="color: rgb(0, 0, 0); font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">直流电阻不平衡</td>
</tr>
<tr class="DS_Table_Row_Grey" _mce_style="font-size: 12px; background-color: #ededed; padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: #000000; border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: #000000;" style="font-size: 12px; background-color: rgb(237, 237, 237); padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: rgb(0, 0, 0); border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: rgb(0, 0, 0);">
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">信道</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">永久链路</td>
</tr>
<tr class="DS_Table_Row_White" _mce_style="font-size: 12px; background-color: #ffffff; padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: #000000; border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: #000000;" style="font-size: 12px; background-color: rgb(255, 255, 255); padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: rgb(0, 0, 0); border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: rgb(0, 0, 0);">
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">TIA Cat 5e 永久链路 (+PoE)</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.20 或 3.0%</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);"><br/></td>
</tr>
<tr class="DS_Table_Row_Grey" _mce_style="font-size: 12px; background-color: #ededed; padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: #000000; border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: #000000;" style="font-size: 12px; background-color: rgb(237, 237, 237); padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: rgb(0, 0, 0); border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: rgb(0, 0, 0);">
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">TIA 6 类永久链路 (+PoE)</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.20 或 3.0%</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);"><br/></td>
</tr>
<tr class="DS_Table_Row_White" _mce_style="font-size: 12px; background-color: #ffffff; padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: #000000; border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: #000000;" style="font-size: 12px; background-color: rgb(255, 255, 255); padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: rgb(0, 0, 0); border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: rgb(0, 0, 0);">
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">TIA 6A 类永久链路 (+PoE)</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.20 或 3.0%</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);"><br/></td>
</tr>
<tr class="DS_Table_Row_Grey" _mce_style="font-size: 12px; background-color: #ededed; padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: #000000; border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: #000000;" style="font-size: 12px; background-color: rgb(237, 237, 237); padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: rgb(0, 0, 0); border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: rgb(0, 0, 0);">
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">ISO11801 PL Class D (+PoE)</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.20 或 3.0%</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.15 或 3.0%</td>
</tr>
<tr class="DS_Table_Row_White" _mce_style="font-size: 12px; background-color: #ffffff; padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: #000000; border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: #000000;" style="font-size: 12px; background-color: rgb(255, 255, 255); padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: rgb(0, 0, 0); border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: rgb(0, 0, 0);">
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">ISO11801 PL Class E (+PoE)</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.20 或 3.0%</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.15 或 3.0%</td>
</tr>
<tr class="DS_Table_Row_Grey" _mce_style="font-size: 12px; background-color: #ededed; padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: #000000; border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: #000000;" style="font-size: 12px; background-color: rgb(237, 237, 237); padding: 5px; border-right-width: thin; border-right-style: solid; border-right-color: rgb(0, 0, 0); border-bottom-width: thin; border-bottom-style: solid; border-bottom-color: rgb(0, 0, 0);">
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">ISO11801 PL2 Class Ea (+PoE)</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.20 或 3.0%</td>
<td style="font-size: 11px; margin: 8px; cursor: text; border-style: dashed; border-color: rgb(187, 187, 187);">0.15 或 3.0%</td>
</tr>
</tbody>
</table>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">如果您要对永久性链路进行测量，则测量仍然使用 DSX-5000，但 TIA 测试不使用“通过/失败”标准，如图 2 所示。如果您发现 PoE 问题并希望排除线缆原因，则这会是有用的信息。</p>
<p style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 13px; line-height: 19px; white-space: normal;"><img src="http://www.faxytech.com/wp-content/plugins/ueditor/ueditor/php/upload/99021426217860.jpg" _mce_src="http://www.faxytech.com/wp-content/plugins/ueditor/ueditor/php/upload/56481426217786.jpg" alt="" style="border: 0px;"/></p>
<p class="DS_Captions" _mce_style="font-size: 11px; font-style: italic; margin-top: 0px; margin-bottom: 20px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; line-height: 19px; white-space: normal; font-size: 11px; font-style: italic; margin-top: 0px; margin-bottom: 20px; padding-top: 0px;">图 2</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px; padding-top: 0px;">现在 TIA 现场测试标准已开放审查，我们可能有正当的理由将直流电阻不平衡测试设定为一种现场测试要求，从而帮助解决与 CCA 线相关的问题，以及更好地保证满足 IEEE 标准的强制 PoE 要求。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;">随着更多的企业部署千兆以太网，更多的 PoE 设备使用 IEEE 的方法 A 同时提供电力与数据，直流电阻不平衡测试将成为更加重要的问题。随着 PoE Plus 部署的不断增长，特别是需要它的 802.11ac WAP 的问世，直流电阻不平衡将成为更加重要的问题，因为更多的电流经过导线会使 PoE 更容易受到直流电阻和电阻不平衡的影响。而且，将来还会考虑更高功率的 PoE 以为需要 30 到 50 瓦的设备提供电力。</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;">别让您的 PoE 系统受到平衡的影响。通过 DSX-5000 进行直流电阻不平衡测试是现今和未来 PoE 系统的简便、低成本的保证。</p>
<p class="DS_Headline" _mce_style="font-size: 1.2em; font-weight: bold; color: #293f6a; vertical-align: top; line-height: 1.4em; word-spacing: normal; margin-bottom: 2px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; white-space: normal; word-spacing: normal; font-size: 1.2em; font-weight: bold; color: rgb(41, 63, 106); vertical-align: top; line-height: 1.4em; margin-bottom: 2px;">使用正确的终端工具提高终端一致性</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;">使用正确的终端工具jackrapid有助于提高 PoE 系统中终端的一致性并避免直流电阻不平衡。为电信线制作终端的打线工具有三种—手动、冲压和多线。手动打线工具的力量大部分来自人力，这会使线对中两根导线间更容易产生不一致。您很难每次为每根导线都使用相同的力，特别是手部疲劳时。</p>
<p style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 13px; line-height: 19px; white-space: normal;"><img _mce_style="width: 400px; height: 400px;" src="http://www.faxytech.com/wp-content/plugins/ueditor/ueditor/php/upload/82041426217860.jpg" _mce_src="http://www.faxytech.com/wp-content/plugins/ueditor/ueditor/php/upload/56421426217786.jpg" border="0" alt="" hspace="0" vspace="0" width="400" height="400" style="border: 0px; width: 400px; height: 400px;"/></p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;">对安装人员力量需要较少的冲压工具是更好的选择，但这些工具仍会造成导线间的终端不一致。保证终端一致的最佳选择是多线工具，如一次挤压便可为所有线对制作终端的 JackRapid，可对所有导线提供相同的力量。多线工具也可缓解手部疲劳，与使用单线终端工具相比制作接头的速度提高八倍，从而显著减少了安装时间。更快、更可靠且一致的终端组合可以减少高达 80% 的返工和成本。</p>
<p class="DS_Headline" _mce_style="font-size: 1.2em; font-weight: bold; color: #293f6a; vertical-align: top; line-height: 1.4em; word-spacing: normal; margin-bottom: 2px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; white-space: normal; word-spacing: normal; font-size: 1.2em; font-weight: bold; color: rgb(41, 63, 106); vertical-align: top; line-height: 1.4em; margin-bottom: 2px;">直流环路电阻与直流电阻不平衡</p>
<p class="DS_Body_Copy" _mce_style="font-size: 1em; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;" style="font-family: Georgia, &#39;Times New Roman&#39;, &#39;Bitstream Charter&#39;, Times, serif; font-size: 1em; white-space: normal; line-height: 1.4em; vertical-align: top; margin-top: 0px; margin-bottom: 22px;">直流环路电阻和直流电阻不平衡之间经常会产生混淆。提供特定的功率的能力取决于特定长度线缆的总直流环路电阻。直流环路电阻的计算方法是线对中两根导线的电阻和。根据 IEEE 标准，线对的通道直流环路电阻必须为 25 Ω 或以下，而恒定直流环路电阻必须为 21 Ω 或以下。</p>
<p><br/></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx5000-poe.html/feed</wfw:commentRss>