		<item>
		<title>DSX-5000适配器是否可用于DSX-8000？DSX-8000与DSX-5000兼容性</title>
		<link>http://www.faxytech.com/archives/dsx-adapter.html</link>
		<comments>http://www.faxytech.com/archives/dsx-adapter.html#comments</comments>
		<pubDate>Mon, 26 Nov 2018 01:17:24 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[DSX-8000]]></category>
		<category><![CDATA[兼容性]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[适配器]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=10455</guid>
		<description><![CDATA[福禄克FLUKE DSX-5000 适配器是否可用于 DSX-8000？DSX-8000 适配器是否可用于 DSX-5000？ 下面的图表显示了两种测量模块及其适配器之间的兼容性... ]]></description>
			<content:encoded><![CDATA[<div><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>FLUKE <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span> <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e9%80%82%e9%85%8d%e5%99%a8" title="查看 适配器 的全部文章" target="_blank">适配器</a></span>是否可用于 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span>？<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-8000" title="查看 DSX-8000 的全部文章" target="_blank">DSX-8000</a></span> 适配器是否可用于 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-5000" title="查看 DSX-5000 的全部文章" target="_blank">DSX-5000</a></span>？ 下面的图表显示了两种测量模块及其适配器之间的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%bc%e5%ae%b9%e6%80%a7" title="查看 兼容性 的全部文章" target="_blank">兼容性</a></span>。</div>
<div></div>
<div><a href="http://www.faxytech.com/wp-content/uploads/2018/11/DSX-1.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-10456" title="DSX-1" src="http://www.faxytech.com/wp-content/uploads/2018/11/DSX-1.png" alt="" width="670" height="220" /></a></div>
<div><a href="http://www.faxytech.com/wp-content/uploads/2018/11/DSX-1.png" class="highslide-image" onclick="return hs.expand(this);"></a><a href="http://www.faxytech.com/wp-content/uploads/2018/11/DSX-2.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-10457" title="DSX-2" src="http://www.faxytech.com/wp-content/uploads/2018/11/DSX-2.png" alt="" width="669" height="366" /></a></div>
<div><a href="http://www.faxytech.com/wp-content/uploads/2018/11/DSX-2.png" class="highslide-image" onclick="return hs.expand(this);"></a><a href="http://www.faxytech.com/wp-content/uploads/2018/11/DSX-3.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-10458" title="DSX-3" src="http://www.faxytech.com/wp-content/uploads/2018/11/DSX-3.png" alt="" width="671" height="186" /></a></div>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-adapter.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克FLUKE DSX系列（DSX-5000,DSX-8000)测试同轴电缆解决方案</title>
		<link>http://www.faxytech.com/archives/dsx-coax-2.html</link>
		<comments>http://www.faxytech.com/archives/dsx-coax-2.html#comments</comments>
		<pubDate>Thu, 27 Sep 2018 06:58:36 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[DSX-8000]]></category>
		<category><![CDATA[dsx-coax]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=10303</guid>
		<description><![CDATA[When it comes to copper testing, we talk a lot about category balanced twisted-pair copper cabling like Category 6, Category 6A and Category 8. And although this cabling type is widely deployed to support everything Ethernet transmission of voice, data a... ]]></description>
			<content:encoded><![CDATA[<p>When it comes to copper testing, we talk a lot about category balanced twisted-pair copper cabling like Category 6, Category 6A and Category 8. And although this cabling type is widely deployed to support everything Ethernet transmission of voice, data and video, that doesn’t mean it’s the only copper cabling you could encounter.</p>
<p>当谈到通缆测试的时候，我们大部分都是讨论双绞线的测试，例如：CAT6，CAT6A和CAT8。尽管这类布线类型已经广泛用于部署语音、数据和视频网络传输，但这并不意味着你只会面临这类布线系统。</p>
<p>Coaxial cabling (sometimes just “coax” for short) has long been used for distribution of data and video signals, and it was one of the first media to support Ethernet with 10BASE2 and 10BASE5 that transmitted 10 Gb/s up to 185 meters or 500 meters, respectively. The term “coaxial” refers the fact that the cable’s center conductor and shield share the same axis, or center point. Some coaxial cable may include multiple shields, such as a quad shielded coax that includes two layers that each consist of a braided shield over a foil shield. It’s the shielding that makes coaxial cable highly resistant to electromagnetic interference and able to carry high frequency signals over long distances.</p>
<p>同轴电缆布线很长一段时间用来传输数据和视频信号，它也是第一批支持10Base2和10Base5（10Base2 在185m可以数据达到10Gb/s ，10Base5在500m可以达到10Gb/s），“同轴”的意思是电缆的中心导体和屏蔽共用同一轴线或中心点。一些同轴电缆也许包含多层屏蔽，例如：四屏蔽同轴电缆，该同轴电缆包括2层，每一层由箔屏蔽上的编织屏蔽组成。正是这种屏蔽使得同轴电缆具有高度抗电磁干扰的能力，并能够在长距离上传输高频信号。</p>
<p>While we often think of coax as being only deployed in residential applications for broadband video and cable TV (CATV), it can still be found in commercial enterprise environment for everything from closed circuit television (CCTV), audio and video, to radio antenna and even some network connections. It therefore makes sense to understand this cable media and how to test it.</p>
<p>虽然我们通常认为同轴电缆仅部署在宽带视频和有线电视(CATV)的住宅应用中，但是它仍然可以在商业企业环境中找到，从闭路电视(CCTV)、音频和视频、到无线电天线甚至一些网络连接。因此，理解这种同轴电缆和如何测试它是有意义的。</p>
<p><strong>The Primary Types</strong></p>
<p><strong>主要类型</strong></p>
<p>There are several different types of coax cables to support a wide range of specialty applications, such as satellite communications, industrial, military and marine applications. The three most common non-industrial coax types are RG6, RG11 and RG59, with RG6 being the most common type you will likely encounter in the enterprise for applications like CCTV and CATV. RG11 has a larger center conductor than RG6, which means it has lower insertion loss and can transmit signals further than RG6. However, thicker RG11 cables cost more and are extremely inflexible, making them impractical for deployment in premise applications and better suited for use in longer-run outside plant installations or for straight backbone links. RG59 is more flexible than RG6, but it features even higher loss and is rarely used anymore except in low-bandwidth, low-frequency analog video applications where distances are short and pathway space is limited (think back-up camera in your car).</p>
<p>有几种不同类型的同轴电缆，以支持广泛的专业应用，如卫星通信，工业，军事和海洋应用。最常见的三种非工业同轴电缆类型是RG6、RG11和RG59，其中RG6是您在企业中可能遇到的用于CCTV和有线电视等应用的最常见类型。RG11具有比RG6大的中心导体，这意味着它具有更低的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>，并且可以比RG6发送更多的信号。然而，较厚的RG11电缆成本更高，并且极其不灵活，使得它们不适合部署在房屋应用中，并且更适合于在长时间运行的外部工厂安装或用于直骨干链路。RG59比RG6更灵活，但是它具有更高的损耗，并且除了在低带宽、低频的模拟视频应用中（距离很短并且路径空间有限）之外，很少再使用它（想想你车中的备用摄像机）。</p>
<p>Coaxial cables also come in various impedances—typically 50, 75 and 93 ohm. 50 ohm coaxial offers higher power handling and is primarily used for radio transmitters like Ham radios, CBs and walkie-talkies. 75 ohm cable does a better job of maintaining signal strength and is primarily used for connecting any type of receiving device such as CATV receivers, high-definition TVs and digital recorders. Originally used in mainframe IBM networks in the 1970s and early 1980s, 93 ohm coax is rare and expensive. While 75 ohm coax is likely the impedance you will encounter in most present-day applications, it’s important to note that all components in a coaxial cabling system should have the same impedance to avoid internal reflections at connection points that can cause signal loss and poor video quality.</p>
<p>同轴电缆也有各种<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>，通常为50, 75欧姆和93欧姆。50欧姆同轴提供更高的功率处理，主要用于无线电发射器，如无线电台，广播和对讲机。75欧姆电缆在保持信号强度方面做得更好，主要用于连接任何类型的接收设备，如有线电视接收机、高清电视和数字记录器。最初在20世纪70年代和80年代初的大型IBM网络中使用，93欧姆同轴电缆是罕见的和昂贵的。虽然75欧姆同轴电缆可能是您在当今大多数应用中遇到的阻抗类型，但需要注意的是，同轴电缆系统中的所有组件都应该具有相同的阻抗，以避免在连接点处出现内部反射，从而可能导致信号丢失和视频质量下降。</p>
<p>&nbsp;</p>
<p>Digital Signal 3 (DS3) signals used to carry traffic in central offices (also referred to as a T3 line) also use coaxial cable, including 75 ohm Type 735 and Type 734. Type 735 cable can be used to cover distances up to 69 meters, while Type 734 cable can be used up to 137 meters. RG6 cable may also be used to carry DS3 signals but over shorter distances.</p>
<p>数字信号3(DS3)信号用于在中央办公室承载业务(也称为T3线路)也使用同轴电缆，包括75欧姆735型和734型。735型电缆可以用来覆盖69米的距离，而734型电缆可以使用到137米。RG6电缆也可用于承载DS3信号，但在更短的距离。</p>
<p>&nbsp;</p>
<p><strong>Testing Made Easy</strong></p>
<p>测试容易</p>
<p>&nbsp;</p>
<p>对于任何同轴电缆，安装的成功依赖于使用高品质的元件和正确的安装方法，尤其是连接器的安装。Insertion loss, which is affected by the overall length of the installed link, is the primary parameter that ensures coaxial cabling will support the intended application.</p>
<p>&nbsp;</p>
<p>ANSI/TIA-568-4.D specifies requirements for 75 ohm broadband coaxial cabling, cords and connecting hardware to support CATV, satellite television and other broadband applications. For the Cabling Subsystem 1 between the outlet and the first distribution point, the length limit is 46 meters for RG6 and 90 meters for RG11. For a Cabling Subsystem 2 between distribution points, the length limit remains at 46 meters for RG6 and increases to 100 meters for RG11. For each of these deployments, TIA-568-4.D specifies insertion loss limits over the frequency range of 5 to 1002 MHz.</p>
<p>按照ANSI / TIA 568 &#8211; 4.D标准75欧姆同轴宽带布线，支持有线电视、卫星电视和其他宽带应用。对于布线子系统，长度限制是46米和90米RG6 RG11为中心。fo布线子系统2点之间的长度分布，限制仍然在46米for RG6 RG11和增加到100米。for each of these deployments，TIA 568 &#8211; 4.D指定插入损耗范围为5Mhz至1002Mhz。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2018/09/Coax-Cable.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-10304" title="Coax-Cable" src="http://www.faxytech.com/wp-content/uploads/2018/09/Coax-Cable.jpg" alt="" width="300" height="289" /></a></p>
<p>Testing is made easy with <span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span>’?DSX-CHA003 Coax Adapter for use with?DSX CableAnalyzer? Series Copper Cable Certifiers. With support for RG6 and RG11 coaxial cabling, the DSX-CHA003 Coax Adapter tests to the TIA insertion loss limits over the full frequency range. Because insertion loss is strongly influenced by the length of the installed link whereby a shorter link may pass even when performance has been significantly degraded by cable damage or poorly installed connectors, the DSX CableAnalyzer also provides Length-Scaled test limits that automatically adjust insertion loss limit based on the actual measured length of the cabling segment.</p>
<p>使用Fluke Networks的DSX-CHA003同轴适配器进行测试很容易，该同轴适配器用于DSX电缆分析仪系列铜电缆认证。在RG6和RG11同轴电缆的支持下，DSX-CHA003同轴适配器在全频范围内测试TIA插入损耗极限。因为插入损耗强烈地受到所安装的链路的长度的影响，因此即使由于电缆损坏或连接器安装不良而导致性能显著下降，较短的链路也可能通过，所以DSX CableAnalyzer还提供了长度缩放的测试限制，该测试限制自动进行广告。基于电缆段实际测量长度的插入损耗极限。</p>
<p>The DSX CableAnalyzer also provides Length-Scaled DS-3 test limits for Type 734, Type 735 and RG6 coaxial cabling used in central office applications. And while only encountered in rare lower-speed applications where a distance greater than 100 meters is required, the DSX CableAnalyzer can also test 50 ohm coaxial cabling used to support legacy 10BASE2 or 10BASE5 Ethernet.</p>
<p>DSX电缆分析仪还提供了用于中央办公室应用的734型、735型和RG6型同轴电缆的长度缩放DS-3测试标准。虽然只在需要大于100米的距离的罕见的低速应用中遇到，但是DSX电缆分析仪还可以测试用于支持传统10BASE2或10BASE5以太网的50欧姆同轴电缆。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-coax-2.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DSX系(DSX2-8000，DSX2-5000)测试单个连接器（RJ45）链路</title>
		<link>http://www.faxytech.com/archives/mptl-3.html</link>
		<comments>http://www.faxytech.com/archives/mptl-3.html#comments</comments>
		<pubDate>Wed, 26 Sep 2018 06:19:03 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[DSX-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[MTPL]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=10293</guid>
		<description><![CDATA[原文：福禄克网络? 翻译：深圳连讯达 Modified Single Connector Permanent Link &#8211; DSX CableAnalyzer 改进的单永久链路测试-DSX系列仪器（DSX2-8000，DSX2-5000）测试仪 Since the release of the Bicsi based Modified One Con... ]]></description>
			<content:encoded><![CDATA[<div id="kb-article">
<p id="article-title">原文：<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>网络? 翻译：深圳连讯达</p>
<p>Modified Single Connector Permanent Link &#8211; DSX CableAnalyzer</p>
<p>改进的单永久链路测试-DSX系列仪器（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx2-8000.html" title="福禄克FLUKE DSX2-8000">DSX2-8000</a></span>，<span class='wp_keywordlink'><a href="http://www.faxy-tech.com/Products/DSX2-5000.html" title="福禄克FLUKE DSX2-5000">DSX2-5000</a></span>）测试仪</p>
<div id="article-body">
<p>Since the release of the Bicsi based Modified One Connector Permanent Link, the TIA has released the Modular Plug Terminated Link (MPTL). The MPTL model is more useful as it uses a Patch Cord Adapter to test the field installed modular plug. Details are available through this KB:</p>
<p>自从BICSI发布了修改型一连接器永久链接以来，TIA已经发布了模块化插头终端链接（MPTL）。MPTL模型更有用，因为它使用一个接插适配器来测试现场安装的模块化插头。</p>
<p>Modular Plug Terminated Link (MPTL) Test Limits for <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span> and <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span></p>
<p><strong>The following information is prior to TIA?MPTL release:</strong></p>
<div>
<div dir="ltr">
<div>
<p><a href="https://fanyi.baidu.com/translate?aldtype=16047&amp;query=Modified+Single+Connector+Permanent+Link+-&amp;keyfrom=baidu&amp;smartresult=dict&amp;lang=auto2zh###"></a></p>
<div><a title="添加到收藏夹"></a></div>
</div>
</div>
</div>
<div>
<div>
<div>
<div dir="ltr">
<p>以下信息是TIA MPTL发布之前的信息：</p>
</div>
</div>
</div>
</div>
<p>With the?<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-5000" title="查看 DSX-5000 的全部文章" target="_blank">DSX-5000</a></span> CableAnalyzer, it is possible to?test a link when the?far end of the cable has been?terminated with a RJ45 plug.</p>
<p>使用DSX-5000电缆认证分析仪，当电缆的远端用RJ45插头时，可以使用一条永久和一个通道进行测试。</p>
<p>Testing this to obtain a warranty from a cabling vendor? You should consult with them on their requirements, since they are issuing the warranty and not <span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span>. Their word is final.</p>
<p>这个测试是否一样可以获得布线供应商的保修服务？你应该去咨询布线供应商是否可行，因为是他们提供产品保修，而不是福禄克网络。</p>
<p>BICSI recognizes this style of link and certain standards bodies are looking to define this link definition.</p>
<p>BICSI承认这种链接模式，并且某些标准机构正在寻找定义这个链接定义。</p>
<p>Connect the DSX-5000 CableAnalyzer as shown?below. The main unit?must be at the patch panel end.</p>
<p>福禄克DSX-5000连接图如下：<span style="color: #ff0000;"><strong>永久链路必须在主机端。</strong></span></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2018/09/MPTL.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-10294" title="MPTL" src="http://www.faxytech.com/wp-content/uploads/2018/09/MPTL.gif" alt="" width="600" height="410" /></a></p>
<p><strong>Selecting the test limit:</strong></p>
<p><strong>测试标准的选择：</strong></p>
<p><strong><a href="http://www.faxytech.com/wp-content/uploads/2018/09/mod-conn1.png" class="highslide-image" onclick="return hs.expand(this);"><img title="mod-conn" src="http://www.faxytech.com/wp-content/uploads/2018/09/mod-conn1.png" alt="" width="300" height="400" /></a></strong></p>
<p><strong><a href="http://www.faxytech.com/wp-content/uploads/2018/09/mod-conn1.png" class="highslide-image" onclick="return hs.expand(this);"></a>Six option<br />
</strong></p>
<ul>
<li>Tap the test limit from the?<strong>HOME SCREEN &gt; </strong><strong>EDIT &gt; </strong><strong>Test Limit &gt;</strong> <strong>MORE</strong></li>
<li><strong>主页 -点击屏幕-点击编辑-测试标准-更多</strong></li>
<li>Slide down to?<strong>Application</strong> and tap to see:</li>
<li>选择<strong>应用标准</strong>ons are available. Cat 5e,?Cat 6 Cat 6A and the (+All) options which adds?ELTCTL,?TCL,?Resistance Unbalance within a pair,?Resistance Unbalance between pairs,?CMRL and?CDNEXT measurements.</li>
<li>Tap?<strong>SAVE &gt; </strong><strong>USE SELECTED.</strong></li>
</ul>
<p>Unlike the <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span> CableAnalyzer, this will not complain/warn about a Permanent Link adapter being mixed with a Channel Adapter. If you get a message indicating the?patch cord at the far end is bad, it means you have failed to maintain the twists in the cable entering the back of the RJ45 plug. You will need to re-terminate the RJ45 plug.</p>
</div>
<div id="article-author">
<p>&nbsp;</p>
</div>
</div>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/mptl-3.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DSX-5000：温度对应福禄克插入损耗（衰减）测试的影响</title>
		<link>http://www.faxytech.com/archives/dsx-il-temp.html</link>
		<comments>http://www.faxytech.com/archives/dsx-il-temp.html#comments</comments>
		<pubDate>Wed, 05 Sep 2018 09:23:35 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[插入损耗]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[衰减]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=10253</guid>
		<description><![CDATA[在ANSI/TIA、ISO/IEC和IEEE中发现的插入损耗限制是基于在20℃（68μF）下运行的链路。随着温度的升高，你可以预期你的链接的插入损耗也会增加。在设计中没有考虑到这一点可能会导致传输错误。... ]]></description>
			<content:encoded><![CDATA[<p>在ANSI/TIA、ISO/IEC和IEEE中发现的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>限制是基于在20℃（68μF）下运行的链路。随着<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>的升高，你可以预期你的链接的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%8f%92%e5%85%a5%e6%8d%9f%e8%80%97" title="查看 插入损耗 的全部文章" target="_blank">插入损耗</a></span>也会增加。在设计中没有考虑到这一点可能会导致传输错误。在某些情况下，预期的应用可能不起作用。</p>
<p>布线标准为这一主题提供了极好的指导。</p>
<p>ANSI/TIA568C.2附录G<br />
电缆可以安装在天花板空气空间、提升管轴和非空调建筑如仓库和制造工厂中，其中温度可以显著高于20℃，以确保符合CLAU规定的通道插入损耗。SE 62.7，根据电缆长度上的环境平均温度、安装电缆的插入损耗裕度和电缆的插入损耗温度系数，水平电缆距离可能需要降低到90米以下。</p>
<p>ISO/IEC 11801:2011表32——水平沟道长度方程<br />
对于高于20℃的工作温度，对于屏蔽电缆，H应减少0.2%，每C C减少0.4%，每C C（20℃至40℃），未屏蔽电缆的0%，6%C（＞40℃～60℃）。其中H是长度。</p>
<p>该ANSI/TIA568C.2标准继续以表格的形式提供额外的指导：</p>
<p>&nbsp;</p>
<p>The Insertion Loss limits found in ANSI/TIA, ISO/IEC and IEEE are based on the link operating at 20 ?C (68 ?F). As temperature increases, you can expect the Insertion Loss of your link to increase too. Failing to take this into account in your design may result in transmission errors. In some cases, the intended application may not work.</p>
<div>
<p>The cabling standards provide excellent guidance on this subject. You are encouraged to purchase these online at either?<a href="https://global.ihs.com/" target="_blank">https://global.ihs.com</a> or?<a href="http://www.iso.org/" target="_blank">http://www.iso.org</a>.</p>
<p><strong>ANSI/TIA-568-C.2 </strong>Annex G<br />
<em>Cables may be installed in return air plenums, in ceiling spaces, riser shafts and non air-conditioned buildings such as warehouses and manufacturing plants where the temperature can be significantly higher than 20 ?C. In order to ensure compliance with the channel insertion loss specified in clause 6.2.7, the horizontal cable distance may need to be reduced below 90 meters depending upon the average temperature of the environment over the length of the cable, the insertion loss margin of the installed cabling, and the insertion loss temperature coefficient of the cable.</em></p>
<p><strong>ISO/IEC 11801:2011</strong> Table 32 – Horizontal channel length equations<br />
<em>For operating temperatures above 20 ?C, H should be reduced by 0,2 % per ?C for screened cables; 0,4 % per ?C (20 ?C to 40 ?C) and 0,6 % per ?C (&gt;40 ?C to 60 ?C) for unscreened cables. </em>Where H is length.</p>
<p>This ANSI/TIA-568-C.2 standard goes on to provide additional guidance in the form of a table:</p>
<div>
<table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="121" valign="top"><strong> </strong>&nbsp;</p>
<p><strong> </strong></p>
<p><strong>Temperature</strong></p>
<p><strong>(?C?(?F))</strong></td>
<td width="105" valign="top"><strong>Maximum</strong>&nbsp;</p>
<p><strong>horizontal?unscreened cable?length?(m)</strong></td>
<td width="105" valign="top"><strong>Maximum</strong>&nbsp;</p>
<p><strong>horizontal screened cablelength?(m)</strong></td>
<td width="105" valign="top"><strong> </strong>&nbsp;</p>
<p><strong>Length?de-rating?(m)</strong></p>
<p><strong>(unscreened)</strong></td>
<td width="105" valign="top"><strong> </strong>&nbsp;</p>
<p><strong>Length?de-rating?(m)(screened)</strong></td>
</tr>
<tr>
<td width="121" valign="top">20?(68)&nbsp;</p>
<p>25?(77)</p>
<p>30?(86)</p>
<p>35?(95)</p>
<p>40?(104)</p>
<p>45?(113)</p>
<p>50?(122)</p>
<p>55?(131)</p>
<p>60?(140)</td>
<td width="105" valign="top">90.0&nbsp;</p>
<p>89.0</p>
<p>87.0</p>
<p>85.5</p>
<p>84.0</p>
<p>81.7</p>
<p>79.5</p>
<p>77.2</p>
<p>75.0</td>
<td width="105" valign="top">90.0&nbsp;</p>
<p>89.5</p>
<p>88.5</p>
<p>87.7</p>
<p>87.0</p>
<p>86.5</p>
<p>85.5</p>
<p>84.7</p>
<p>83.0</td>
<td width="105" valign="top">0.0&nbsp;</p>
<p>1.0</p>
<p>3.0</p>
<p>4.5</p>
<p>6.0</p>
<p>8.3</p>
<p>10.5</p>
<p>12.8</p>
<p>15.0</td>
<td width="105" valign="top">0.0&nbsp;</p>
<p>0.5</p>
<p>1.5</p>
<p>2.3</p>
<p>3.0</p>
<p>3.5</p>
<p>4.5</p>
<p>5.3</p>
<p>6.0</td>
</tr>
</tbody>
</table>
</div>
<p>Some field testers allow you to adjust the insertion loss PASS/FAIL line based on temperature. This is not permitted per ANSI/TIA, ISO/IEC and IEEE. If your cable is to be subjected to an elevated temperature, your design must take this into account by reducing the length of the link, not by relaxing the Insertion Loss limit.</p>
<p><span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>或者<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-5000" title="查看 DSX-5000 的全部文章" target="_blank">DSX-5000</a></span>? does not allow you to adjust the Insertion Loss in any of its field testers based on temperature.</p>
</div>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-il-temp.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克FLUKE DSX-5000和DSX-8000实现百通的Belden 2183标准。</title>
		<link>http://www.faxytech.com/archives/dsx-belden-2183.html</link>
		<comments>http://www.faxytech.com/archives/dsx-belden-2183.html#comments</comments>
		<pubDate>Mon, 03 Sep 2018 09:00:57 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[Belden 2183]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[DSX-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=10243</guid>
		<description><![CDATA[Implementing limits on the Fluke Networks Versiv Belden’s 4K UHD Media Cables, 2183P and 2183R, are specifically designed to deliver 4K content over HDBaseT up to 100 m, support HDBaseT 5Play and carry the UL 4299 Power Over HDBaseT (PoH) certification... ]]></description>
			<content:encoded><![CDATA[<h1 id="article-title">Implementing limits on the <span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span></h1>
<div id="article-body">
<p>Belden’s 4K UHD Media Cables, 2183P and 2183R, are specifically designed to deliver 4K content over HDBaseT up to 100 m, support HDBaseT 5Play and carry the UL 4299 Power Over HDBaseT (PoH) certification, all in a small, flexible design.</p>
<p>There are specific field testing limits for these cables designed by Belden and <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fluke" title="查看 Fluke 的全部文章" target="_blank">Fluke</a></span> Networks. There are three limits that are available, Channel and Permanent Link that we are familiar with, and a third test limit named Direct Attach. The Direct Attach limit can be used when the installed link does not have any jacks and is just a plug to plug link, essentially a long patch cord. It is important to use this limit if you are working with field installed RJ-45 plugs.</p>
<p>In order to test the Direct Attach links, Belden recommends the use of their AX104552 couplers and attaching these directly to the end of the DSX-PLA004 permanent link adapters.</p>
<p><img class="alignnone size-full wp-image-10244" title="1connections" src="http://www.faxytech.com/wp-content/uploads/2018/09/1connections.png" alt="" width="623" height="567" /></p>
<p>&nbsp;</p>
<p><img class="alignnone size-full wp-image-10245" title="2actualRevconnect" src="http://www.faxytech.com/wp-content/uploads/2018/09/2actualRevconnect.png" alt="" width="1109" height="349" /></p>
<p>Permanent Link Adapter =&gt; AX104552 coupler =&gt; Rev Connect Plug</p>
<p>&nbsp;</p>
<p>Regular Direct Attach links are tested with Patch Cord Adapters.</p>
<p>This document describes step-by-step instructions for selecting these test limits in the Fluke Versiv Tester.</p>
<p>You can configure <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/belden-2183" title="查看 Belden 2183 的全部文章" target="_blank">Belden 2183</a></span> limits from Linkware Live, or from the tester. Instructions for setting up a project through Linkware Live are located?here.</p>
<p>&nbsp;</p>
<p><img class="alignnone size-full wp-image-10246" title="DSX-8000-choose-limit" src="http://www.faxytech.com/wp-content/uploads/2018/09/DSX-8000-choose-limit.png" alt="" width="1024" height="650" /></p>
<p>&nbsp;</p>
<ol>
<li> Select Project</li>
<li> New Project</li>
<li> Name your Project</li>
<li> Select Test Set Up or NEW TEST</li>
<li> Select Cable Type</li>
<li> More</li>
<li> Manufacturers</li>
<li> Belden</li>
</ol>
<p><img class="alignnone size-full wp-image-10247" title="DSX-8000-choose-limit2" src="http://www.faxytech.com/wp-content/uploads/2018/09/DSX-8000-choose-limit2.png" alt="" width="974" height="634" />?</p>
<p>&nbsp;</p>
<ol>
<li> Select your cable type, Riser or Plenum</li>
<li> Test Limit</li>
<li> More (this page shows the Last Used limits</li>
<li> Vendor</li>
<li> Selct your limit, Channel or Permanent Link or Direct Attach</li>
<li> SAVE</li>
<li> Back or HOME key</li>
<li> Push TEST to start</li>
</ol>
<p>&nbsp;</p>
</div>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-belden-2183.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DSX-600，DSX-5000与DSX-8000的区别？</title>
		<link>http://www.faxytech.com/archives/dsx-different.html</link>
		<comments>http://www.faxytech.com/archives/dsx-different.html#comments</comments>
		<pubDate>Tue, 07 Nov 2017 10:22:03 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[DSX-600]]></category>
		<category><![CDATA[DSX-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=9385</guid>
		<description><![CDATA[功能 DSX-600 DSX-5000 DSX-8000 说明 必不可少的 Cat 6A 和 Class EA?铜缆测试仪 Cat 6A 和 Class FA?铜缆测试仪 最快、最准确的 Cat 8 和 Class I/II 铜缆测试仪 Cat 3 – Cat 6A / Class EA √ √ √ Cat 6A / Class FA √ √ C... ]]></description>
			<content:encoded><![CDATA[<table>
<tbody>
<tr>
<th>功能</th>
<th><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-600.html" title="福禄克DSX-600">DSX-600</a></span></th>
<th> <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span></th>
<th><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span></th>
</tr>
<tr>
<td>说明</td>
<td>必不可少的 Cat 6A 和 Class EA?<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>测试仪</td>
<td>Cat 6A 和 Class FA?铜缆测试仪</td>
<td>最快、最准确的 Cat 8 和 Class I/II 铜缆测试仪</td>
</tr>
<tr>
<td>Cat 3 – Cat 6A / Class EA</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Cat 6A / Class FA</td>
<td></td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>Cat 8 / Class I/II</td>
<td></td>
<td></td>
<td>√</td>
</tr>
<tr>
<td>最大频率</td>
<td>500 MHz</td>
<td>1000 MHz</td>
<td>2000 MHz</td>
</tr>
<tr>
<td>自动测试时间</td>
<td>10 秒 Class EA/Cat 6A<br />
9 秒 Class E/Cat 6</td>
<td>10 秒 Class EA/Cat 6A<br />
9 秒 Class E/Cat 6</td>
<td>16 秒 Cat 8 / Class I/II<br />
8 秒 Class EA/Cat 6A<br />
7 秒 Class E/Cat 6</td>
</tr>
<tr>
<td>屏蔽完整性测试</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>内存</td>
<td>≈ 12,000 Cat 6A 带图</td>
<td>≈ 12,000 Cat 6A 带图</td>
<td>≈ 12,000 Cat 6A 带图</td>
</tr>
<tr>
<td>电池寿命</td>
<td>≈ 8 小时</td>
<td>≈ 8 小时</td>
<td>≈ 8 小时</td>
</tr>
<tr>
<td>线缆标识符长度</td>
<td>60 字符</td>
<td>60 字符</td>
<td>60 字符</td>
</tr>
<tr>
<td>永久链路适配器</td>
<td>可选</td>
<td>√</td>
<td></td>
</tr>
<tr>
<td>ProjXTM?项目管理</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>TaptiveTM?手势用户界面</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>先进的故障信息诊断</td>
<td>有限 – (HDTDR &amp; HDTDX)</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>PoE 电阻不平衡</td>
<td></td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>集成外部串扰功能</td>
<td></td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>LinkWareTM?专业报告</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>LinkWareTM?实时支持</td>
<td>√</td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>TCL 测量</td>
<td></td>
<td>√</td>
<td>√</td>
</tr>
<tr>
<td>同轴适配器</td>
<td>可选</td>
<td>可选</td>
<td>可选</td>
</tr>
<tr>
<td>M12 适配器</td>
<td>可选</td>
<td>可选</td>
<td>可选</td>
</tr>
<tr>
<td><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-patchcord-adapter.html" title="跳线适配器">跳线适配器</a></span></td>
<td></td>
<td>可选</td>
<td>可选</td>
</tr>
<tr>
<td>光纤 – OLTS、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span> 和检测</td>
<td></td>
<td>可选</td>
<td>可选</td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
<td>模块化 <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> 系列面向未来的设计支持 TIA Cat 8 和 ISO Class I/II、单模和多模光纤损耗、OTDR 测试以及检测。先进的诊断能够使用简单的语言即时指出线缆故障原因和位置。两款 Versiv 铜缆测试仪均提供支持先进技术的测量，包括 NBASE-T 和其他应用的外来串扰，以及以太网供电 (PoE) 的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>不平衡。</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-different.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【PoE】-数据电缆测试入门和常见测试问题解答</title>
		<link>http://www.faxytech.com/archives/poe.html</link>
		<comments>http://www.faxytech.com/archives/poe.html#comments</comments>
		<pubDate>Tue, 12 Sep 2017 01:11:23 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[dsx8000]]></category>
		<category><![CDATA[PoE]]></category>
		<category><![CDATA[平衡参数]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=9263</guid>
		<description><![CDATA[【PoE】 ?Power of Ethernet，直译为以太网供电，意指用以太网的网线给对端连接的设备供电，就像电话机那样(电话机不用本地供电)。供电电源由以太网交换机经网线提供。跟电话机一样，通常也... ]]></description>
			<content:encoded><![CDATA[<p>【<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/poe" title="查看 PoE 的全部文章" target="_blank">PoE</a></span>】 ?Power of Ethernet，直译为以太网供电，意指用以太网的网线给对端连接的设备供电，就像电话机那样(电话机不用本地供电)。供电电源由以太网交换机经网线提供。跟电话机一样，通常也是 48V 的直流电。PoE 目前分四级，Class 1 供电 3.6 瓦，Class 4 为 25.5 瓦。设备的耗电功率不能超过 PoE 等级。导线又细又长的线对是不能支持 ?PoE Class 4 的。</p>
<p>随着POE设备的越来越多，许多客户要求可以测试POE的设备。所以标准组织如TIA等，都加入了<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%b9%b3%e8%a1%a1%e5%8f%82%e6%95%b0" title="查看 平衡参数 的全部文章" target="_blank">平衡参数</a></span>的测试。而福禄克支持平衡参数的设备有，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span> 八类<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="线缆分析仪">线缆分析仪</a></span>和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span> 超七类线缆分析仪都支持。标准选择是后面加（+ALL）的标准。</p>
<p>&nbsp;</p>
<p>参考阅读：</p>
<h2><a href="http://dsx5000.faxytech.com/dsx5000-banlance/" target="_blank">Fluke DSX-5000:为什么要测试平衡参数特性？</a></h2>
<p>地址：<a href="http://dsx5000.faxytech.com/dsx5000-banlance/" target="_blank">http://dsx5000.faxytech.com/dsx5000-banlance/</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/poe.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>如何用FLUKE测试仪快速定位故障？</title>
		<link>http://www.faxytech.com/archives/find-fault.html</link>
		<comments>http://www.faxytech.com/archives/find-fault.html#comments</comments>
		<pubDate>Tue, 08 Aug 2017 00:58:13 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSP-4000]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[线缆测试仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=9162</guid>
		<description><![CDATA[初次使用福禄克仪器的同学可能不太明白要怎么从测试结果中获得故障定位信息，深圳连讯达有一些易读易懂的故障示意图，这里我们做一点简单的入门介绍。 &#160; DSP系列线缆分析仪： DSP系... ]]></description>
			<content:encoded><![CDATA[<p>初次使用福禄克仪器的同学可能不太明白要怎么从测试结果中获得故障定位信息，深圳连讯达有一些易读易懂的故障示意图，这里我们做一点简单的入门介绍。</p>
<p>&nbsp;</p>
<p><strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsp-4000series.html" title="福禄克FLuke DSP">DSP</a></span>系列<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="线缆分析仪">线缆分析仪</a></span>：</strong></p>
<p>DSP系列（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsp-4000series.html" title="福禄克Fluke　DSP4000">DSP4000</a></span>,DSP4300）是上个世纪90年代初期设计的产品，最高测试规格是Cat6电缆链路，英文界面配中文说明书。不合格的链路标记为FAIL（失败），合格的标记为PASS（通过）。参数合格的标记为“√?”，有问题的标记为”×”。按下主屏幕下对应的F1键，就会显示故障部位的示意图。用户可以使用仪器上面的四个方向键和Enter键来察看故障位置和可能的故障原因。故障图形是一根电缆链路的示意图，链路中的小方块一般表示连接器(模块)，旁边有故障文字说明，数字表示故障点所在的位置(距离)。文字均为英文。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/08/DSP.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9163" title="福禄克DSP" src="http://www.faxytech.com/wp-content/uploads/2017/08/DSP.jpg" alt="" width="512" height="259" /></a></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/08/DSP-permlink.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9164" title="DSP-permlink永久链路适配器" src="http://www.faxytech.com/wp-content/uploads/2017/08/DSP-permlink.jpg" alt="DSP-permlink永久链路适配器" width="512" height="235" /></a></p>
<p>进阶：</p>
<p>如果你懂得了上述<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>、RL、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>不连续等参数的原理，则可以使用测试结果屏幕中最后罗列的两个高精度故障诊断专利工具“HDTDX”(高精度时域串扰)和“HDTDR”(高精度时域反射)来直观地察看、定位故障参数的劣化程度和精确位置。</p>
<p>DSP系列电缆分析仪不支持新的抗干扰能力（平衡参数TCL、TECT等）的测试。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>系列线缆分析仪：</strong></p>
<p>DTX系列线缆分析仪（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1500.html " title="福禄克FLuke DTX-1500">DTX-1500</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span>）的设计跟DSP相似，可以测试Cat7+链路。测试完成后按下F1键就可以察看故障示意图，操作方法同DSP，但文字说明可以是中文的。也同样有“HDTDX”和“HDTDR”两个专利分析定位故障的工具。测试速度更快，示意图更易懂。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/08/DTX-1800.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9165" title="DTX-1800" src="http://www.faxytech.com/wp-content/uploads/2017/08/DTX-1800.jpg" alt="" width="512" height="391" /></a></p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/08/dtx-1800-rl.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9166" title="dtx-1800-rl" src="http://www.faxytech.com/wp-content/uploads/2017/08/dtx-1800-rl.jpg" alt="" width="512" height="385" /></a></p>
<p><img src="data:image/gif;base64,iVBORw0KGgoAAAANSUhEUgAAAAEAAAABCAYAAAAfFcSJAAAADUlEQVQImWNgYGBgAAAABQABh6FO1AAAAABJRU5ErkJggg==" alt="" /></p>
<p><img src="data:image/gif;base64,iVBORw0KGgoAAAANSUhEUgAAAAEAAAABCAYAAAAfFcSJAAAADUlEQVQImWNgYGBgAAAABQABh6FO1AAAAABJRU5ErkJggg==" alt="" /></p>
<p>&nbsp;</p>
<p><strong>DSX系列线缆分析仪：</strong></p>
<p>&nbsp;</p>
<p>这是新一代的线缆分析仪，属于<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span>系列手持测试平台，采用模块化设计。目前的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>线缆分析仪模块支持Cat7A链路测试，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span>支持Cat8链路测试。采用智能手机触摸屏，测试后直接显示故障示意图。初学者可以直接点击“WireMap”和“故障信息”标签，查看其中的线序错误和“红色”失败提示符，进一步点击还可以显示可能的故障原因说明，按下问号还会给出专业解释和纠错方法等专家建议。同样地，保留了专利的“HDTDR”和“HDTDX”故障专业诊断定位工具。并且对与高频故障的定位精度相较DTX有较大提升。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/08/dsx.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9167" title="dsx-5000" src="http://www.faxytech.com/wp-content/uploads/2017/08/dsx.jpg" alt="" width="512" height="240" /></a></p>
<p><img src="data:image/gif;base64,iVBORw0KGgoAAAANSUhEUgAAAAEAAAABCAYAAAAfFcSJAAAADUlEQVQImWNgYGBgAAAABQABh6FO1AAAAABJRU5ErkJggg==" alt="" /></p>
<p>&nbsp;</p>
<p>Versiv系列可以像手机那样多点触控屏幕放大、缩小参数曲线，方便查看细节。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/08/DSX-5000-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9168" title="DSX-5000-2" src="http://www.faxytech.com/wp-content/uploads/2017/08/DSX-5000-2.jpg" alt="" width="512" height="369" /></a></p>
<p>DSX系列支持抗外来干扰能力测试，是目前唯一具备支持现场不平衡参数测试的手持式<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%ba%bf%e7%bc%86%e6%b5%8b%e8%af%95%e4%bb%aa" title="查看 线缆测试仪 的全部文章" target="_blank">线缆测试仪</a></span>(TIA568C:2010/ISO11801:2010)。由于采用模块化设计，更换模块后可以完成完整的光纤一级测试(T1测试，默认EF光源)和二级测试(T2测试，最小0.5米事件死区)。</p>
<p>&nbsp;</p>
<p><img src="data:image/gif;base64,iVBORw0KGgoAAAANSUhEUgAAAAEAAAABCAYAAAAfFcSJAAAADUlEQVQImWNgYGBgAAAABQABh6FO1AAAAABJRU5ErkJggg==" alt="" /><a href="http://www.faxytech.com/wp-content/uploads/2017/08/DSX5000-3.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9169" title="DSX5000-3" src="http://www.faxytech.com/wp-content/uploads/2017/08/DSX5000-3.jpg" alt="" width="512" height="366" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/find-fault.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克测试仪DTX-1500,DSX-600,DTX-1800,DSX-5000,DSX-8000的区别。</title>
		<link>http://www.faxytech.com/archives/cabletester-choose.html</link>
		<comments>http://www.faxytech.com/archives/cabletester-choose.html#comments</comments>
		<pubDate>Wed, 02 Aug 2017 04:33:10 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[新闻资讯]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[DSX-600]]></category>
		<category><![CDATA[DSX-8000]]></category>
		<category><![CDATA[DTX-1500]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=9140</guid>
		<description><![CDATA[福禄克电缆测试仪选购指南（DTX-1800,DSX-5000,DSX-8000) 我们经常听到一句话就是：“我们的网线要过福禄克测试”。那这个是什么意思呢？福禄克测试指的是用福禄克测试仪对网线质量进行认证，... ]]></description>
			<content:encoded><![CDATA[<p><strong><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="电缆测试仪">电缆测试仪</a></span>选购指南（</strong><strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span>)</strong></p>
<p><span style="font-family: 宋体;">我们经常听到一句话就是：</span>“我们的网线要过福禄克测试”。那这个是什么意思呢？福禄克测试指的是用福禄克测试仪对网线质量进行认证，那么是不是所有的福禄克测试仪都可以测试呢？答案是否定的。</p>
<p><span style="font-family: 宋体;">福禄克（</span>FLUKE<span style="font-family: 宋体;">）是一个品牌。能测试网线的是属于福禄克网络的一部分业务，而且对于要过福禄克测试的，一般是通常是要求能出具测试报告的。 那么福禄克的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-cexian.html" title="测线仪">测线仪</a></span></span><span style="font-family: Calibri;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/mt-8200-60-kit.html" title="福禄克FLuke MT-8200-60-KIT 寻线器">MT-8200-60-KIT</a></span></span><span style="font-family: 宋体;">和</span><span style="font-family: Calibri;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/microscanner2.html" title="福禄克Microscanner2">MS2-100</a></span></span><span style="font-family: 宋体;">就不能满足了。最低要求也得</span><span style="font-family: Calibri;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/cableiq.html" title="福禄克FLUKE CABLEIQ测试仪">CIQ-100</a></span></span><span style="font-family: 宋体;">了。</span></p>
<p><span style="font-family: 宋体;">那既然</span><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/cableiq.html" title="CIQ">CIQ</a></span>-100<span style="font-family: 宋体;">可以出测试报告，那么我为什么还要选择高端的</span><span style="font-family: Calibri;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-1500</span><span style="font-family: 宋体;">，</span><span style="font-family: Calibri;">DTX-1800</span><span style="font-family: 宋体;">，</span><span style="font-family: Calibri;"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-5000" title="查看 DSX-5000 的全部文章" target="_blank">DSX-5000</a></span></span><span style="font-family: 宋体;">或者</span><span style="font-family: Calibri;"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-8000" title="查看 DSX-8000 的全部文章" target="_blank">DSX-8000</a></span></span><span style="font-family: 宋体;">测试仪。这就是我们今天连讯达工程师要讲的内容。</span></p>
<p>&nbsp;</p>
<p><strong><span style="font-family: 宋体;">第一：关于</span>CIQ-100<span style="font-family: 宋体;">的说明。</span></strong><strong> </strong></p>
<p><span style="font-family: 宋体;">如果只是自己做的工程，或者只要对线材进行速率判断的，判断线材是不是满足</span>10M<span style="font-family: 宋体;">、</span><span style="font-family: Calibri;">100M</span><span style="font-family: 宋体;">或者</span><span style="font-family: Calibri;">1000M</span><span style="font-family: 宋体;">的要求，那么</span><span style="font-family: Calibri;">CIQ-100</span><span style="font-family: 宋体;">就够了。</span></p>
<p>&nbsp;</p>
<p><strong>第二：什么时候要用到认证测试仪？</strong><strong> </strong></p>
<p><span style="font-family: 宋体;">大多数客户不仅仅是要速度，而且要对线材的电气性能进行测试：如<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>，</span><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span><span style="font-family: 宋体;">，回拨损耗，电阻，接线图，长度等参数进行测试。那么就必须要认证级别的测试仪了。</span></p>
<p>&nbsp;</p>
<p><strong>第三：认证测试仪的区别？</strong></p>
<p><span style="font-family: 宋体;">如果只是要测试到</span>CAT5E<span style="font-family: 宋体;">，</span><span style="font-family: Calibri;">CAT6</span><span style="font-family: 宋体;">，</span><span style="font-family: Calibri;">CAT6A</span><span style="font-family: 宋体;">的线缆，那么选择</span><span style="font-family: Calibri;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1500.html " title="福禄克FLuke DTX-1500">DTX-1500</a></span></span><span style="font-family: 宋体;">无疑是性价比最高的设备，购买这一款就够了。如果考虑后期有光纤要测试，需要拓展光纤模块，那么就可以选择</span><span style="font-family: Calibri;">DTX-1800</span><span style="font-family: 宋体;">。（光纤模块不便宜，价格比设备还贵）。</span><span style="font-family: Calibri;">DTX-1800</span><span style="font-family: 宋体;">比</span><span style="font-family: Calibri;"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dtx-1500" title="查看 DTX-1500 的全部文章" target="_blank">DTX-1500</a></span></span><span style="font-family: 宋体;">带宽更大一些，多了</span><span style="font-family: Calibri;">CAT7</span><span style="font-family: 宋体;">类的测试标准。 </span><span style="font-family: Calibri;">DSX-5000</span><span style="font-family: 宋体;">的比</span><span style="font-family: Calibri;">DTX-1800</span><span style="font-family: 宋体;">多了</span><span style="font-family: Calibri;">CAT7A</span><span style="font-family: 宋体;">的标准。</span><span style="font-family: Calibri;">DSX-8000</span><span style="font-family: 宋体;">比</span><span style="font-family: Calibri;">DSX-5000</span><span style="font-family: 宋体;">多了</span><span style="font-family: Calibri;">CAT8</span><span style="font-family: 宋体;">的标准。</span></p>
<p><span style="font-family: 宋体;">结论：个人觉得，如果是测试仪</span>CAT5E<span style="font-family: 宋体;">或者</span><span style="font-family: Calibri;">CAT6</span><span style="font-family: 宋体;">网线，选择</span><span style="font-family: Calibri;">DTX-1500</span><span style="font-family: 宋体;">。如果有光纤或者看您有</span><span style="font-family: Calibri;">CAT7</span><span style="font-family: 宋体;">类线材，选择</span><span style="font-family: Calibri;">DTX-1800</span><span style="font-family: 宋体;">。如果更高要求，例如要测试7A，就选择DSX-5000，如果要测试CAT8类线材就是</span><span style="font-family: Calibri;">DSX-8000</span><span style="font-family: 宋体;">。价格是从</span><span style="font-family: Calibri;">DTX-1500</span><span style="font-family: 宋体;">到</span><span style="font-family: Calibri;">DTX-1800</span><span style="font-family: 宋体;">，到</span><span style="font-family: Calibri;">DSX-5000</span><span style="font-family: 宋体;">再到</span><span style="font-family: Calibri;">DSX-8000</span><span style="font-family: 宋体;">依次上涨。具体价格联系</span><span style="font-family: Calibri;">0755-83999818</span></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/cabletester-choose.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【专业文章】福禄克DTX系列(DTX-1800),DSX系列(DSX5000,DSX8000)如何导出报告?</title>
		<link>http://www.faxytech.com/archives/report-output.html</link>
		<comments>http://www.faxytech.com/archives/report-output.html#comments</comments>
		<pubDate>Wed, 19 Jul 2017 03:04:57 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[报告]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=9085</guid>
		<description><![CDATA[福禄克网线测试仪的测试操作实际上是很简单的，那么我们在测试结束后要怎么导出仪器里的报告呢，其实也是非常简单的，接下来我们来讲解一下怎么导出报告。 （本教程适用型号：DTX-1800... ]]></description>
			<content:encoded><![CDATA[<p><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>网线测试仪的测试操作实际上是很简单的，那么我们在测试结束后要怎么导出仪器里的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%8a%a5%e5%91%8a" title="查看 报告 的全部文章" target="_blank">报告</a></span>呢，其实也是非常简单的，接下来我们来讲解一下怎么导出报告。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/07/DTX-1800-report.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9086" title="DTX-1800-report" src="http://www.faxytech.com/wp-content/uploads/2017/07/DTX-1800-report.png" alt="" width="303" height="402" /></a></p>
<p>（本教程适用型号：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-1500、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span>、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-600.html" title="福禄克DSX-600">DSX-600</a></span>等线缆认证测试仪）</p>
<p>&nbsp;</p>
<p><strong>准备工作：</strong></p>
<p>仪器主机*1台</p>
<p>Linkware软件（最新版下载地址：http://www.faxytech.com/<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="linkware">linkware</a></span>）</p>
<p>USB数据线*1根 ?普通电脑win7 XP 系统都可以</p>
<p><img src="http://mmbiz.qpic.cn/mmbiz_png/fgnkxfGnnkRLI7MTliaNGhvhLRsGkLpoy1EgPYJLI51Aicg8ATQ682Yjq9nQ7IZmjajxHJf9ZDXiaXicIHz4tafpfQ/0.png?tp=webp&amp;wxfrom=5&amp;wx_lazy=1" alt="" /></p>
<p>&nbsp;</p>
<p><img src="http://mmbiz.qpic.cn/mmbiz_png/fgnkxfGnnkRLI7MTliaNGhvhLRsGkLpoyM3ryE6BTbhBv96hRUxXWjxrUMibmmgQ6T2h8MG7UTH9h89ROhzckPtw/0.png?tp=webp&amp;wxfrom=5&amp;wx_lazy=1" alt="" /><strong>操作步骤</strong><img src="http://mmbiz.qpic.cn/mmbiz_png/fgnkxfGnnkRLI7MTliaNGhvhLRsGkLpoybvs4Q6j1r3wWJ6aqXhiazPEkSXB5V7RPz6piaE4QLbNoXNoGUb5CC21A/0.png?tp=webp&amp;wxfrom=5&amp;wx_lazy=1" alt="" /></p>
<p><strong>①</strong>在电脑上安装<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> 的软件Linkware。安装好后出现如下图片。默认为英文版。</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/07/linkware.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9087" title="linkware" src="http://www.faxytech.com/wp-content/uploads/2017/07/linkware.jpg" alt="" width="640" height="461" /></a></p>
<p>&nbsp;</p>
<p><strong>②</strong>对于中国用户可能不习惯英文界面。我们可以通过选择options – Language -chinese(Simplified)。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9088" title="linkware-2" src="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-2.jpg" alt="" width="640" height="461" /></a></p>
<p>&nbsp;</p>
<p><strong>③</strong>将仪器开机，用数据线连接至电脑。点击软件上【红色带闪电的箭头】，软件会自动识别连接仪器的型号。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-3.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9089" title="linkware-3" src="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-3.jpg" alt="" width="640" height="461" /></a></p>
<p>&nbsp;</p>
<p><strong><br />
</strong></p>
<p><strong>④</strong>点击后，会弹出如下界面，这时候就可以选择 1、导入测试中所有的结果。 2、选择需要导入的结果。这时就可以根据自己的需求来选择了。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-4.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9090" title="linkware-4" src="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-4.jpg" alt="" width="640" height="461" /></a></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-5.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9091" title="linkware-5" src="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-5.jpg" alt="" width="640" height="461" /></a></p>
<p>（↑成功导出测试报告界面↑）</p>
<p>&nbsp;</p>
<p><strong>⑤</strong>点击左上角的PDF按键，把当前的测试报告转换成PDF文件。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-6.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9092" title="linkware-6" src="http://www.faxytech.com/wp-content/uploads/2017/07/linkware-6.jpg" alt="" width="640" height="360" /></a></p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2017/07/report.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9093" title="report" src="http://www.faxytech.com/wp-content/uploads/2017/07/report.jpg" alt="" width="640" height="489" /></a></p>
<p>（↑报告导出效果展示↑）</p>
<p>以上就是导出报告的全过程了，现在还等什么，赶紧拿着报告给甲方验收呀，咱老板为了这工程收款的事都愁死啦~</p>