		<item>
		<title>升级10Gb光纤网络，我们需要CertiFiber OptiFiber保驾护航</title>
		<link>http://www.faxytech.com/archives/10g-fiber.html</link>
		<comments>http://www.faxytech.com/archives/10g-fiber.html#comments</comments>
		<pubDate>Mon, 31 Oct 2016 01:16:01 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[10Gb]]></category>
		<category><![CDATA[CertiFiber]]></category>
		<category><![CDATA[CFP-100-M]]></category>
		<category><![CDATA[CFP-100-Q]]></category>
		<category><![CDATA[CFP-100-S]]></category>
		<category><![CDATA[OFP-100-Q]]></category>
		<category><![CDATA[OptiFiber]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8179</guid>
		<description><![CDATA[自光纤标准10GBASE-SR发布以来，将LAN中的骨干布线设施升级到支持10 Gb的活动已经持续了数年，但许多企业业务在此之前并不需要这种速度。 数据中心快速升级到25、40甚至100 Gb速率，以支持虚拟... ]]></description>
			<content:encoded><![CDATA[<p>自光纤标准10GBASE-SR发布以来，将LAN中的骨干布线设施升级到支持10 Gb的活动已经持续了数年，但许多企业业务在此之前并不需要这种速度。</p>
<p>数据中心快速升级到25、40甚至100 Gb速率，以支持虚拟服务器数量的快速增加，从而容纳比以往更多的应用以及需要访问、发送和存储的大量数据。同时，LAN中高速传输数据的需求也达到前所未有的高度，包括有线和无线连接。尽管大学和金融机构等大型企业已经升级了其LAN骨干网，但仍有大量其他机构才刚刚意识到1 Gb速率显然不能满足要求。现在散发的大多数资料信息都集中在将数据中心的光纤设施升级到支持40 Gb和100 Gb速率，但我们认为现在才升级到10 Gb的用户不应该被遗忘，并且会从重新审视关键事项中获益。</p>
<p>&nbsp;</p>
<p>讨论升级到10 Gb光纤速率时，归根结底要看布线是否支持这样的速率，有许多关于光纤类型和通道总长度的事项需要考虑。LAN骨干设施常用的多模光纤中，<strong>信号变差是由于模式色散造成的</strong>。发生模式色散时，光脉冲在一定距离内传播并在不同的时间到达接收器，从而造成误码。这是高速传输的限制因素。较新型的光纤经过特殊设计以防止模式色散，旧型62.5?m多模光纤不在此列。采用这种光纤分布式数据接口(FDDI)级光纤的网络在10 Gb速率下被限制到大约26米——很不切合实际的距离：大多数LAN骨干网一般要求接近300米的距离。为了达到要求的LAN骨干网络距离，光纤就必须升级到激光优化的50?m多模光纤<strong>，OM3支持距离长达300米的10 Gb速率</strong>，<strong>OM4支持距离长达400米的10 Gb速率</strong>。</p>
<p><strong>降低损耗</strong></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/10/10g.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8180" title="降低损耗" src="http://www.faxytech.com/wp-content/uploads/2016/10/10g.jpg" alt="" width="600" height="331" /></a></p>
<p>除了光纤类型和距离外，能够真正说明骨干光纤是否支持10 Gb速率的关键参数是<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>。通过该参数，我们能够知道一个端对端通道中的信号损耗达到多少，并且强度仍然足以支持应用。</p>
<p>尽管有些安装方在1 Gb系统时凭侥幸没有计算衰减，但当我们向10 Gb速率升级时，这种做法不可取。10 Gb通道的最大衰减量已经从1 Gb应用时的3.5dB降为2.6dB (850 nm OM3光纤)。衰减与许多因素有关——发送器中使用的光源、电缆类型、通道总长度、连接及接头的数量和质量。对损耗影响最大以及妨碍10 Gb速率支持能力的最常见原因是光纤端面污染。电信机房并不总是最清洁的环境，夹在光纤端面之间的任何灰尘或碎屑都会造成信号损耗、背向反射甚至损害设备。无论哪种类型的光纤，正确的光纤清洁和检查都是确保支持10 Gb所不可缺少的一部分。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/10/cfp-100-q.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8181" title="cfp-100-q" src="http://www.faxytech.com/wp-content/uploads/2016/10/cfp-100-q.jpg" alt="" width="601" height="467" /></a></p>
<p>即使您选择了正确的电缆类型，并确信能够接受距离限制以及最大程度清洁和检查了光纤端面，但唯一能够100%保证支持IEEE 802.3 10GBASE-SR应用的措施是对光纤链路进行认证。</p>
<p>使用<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> ?Pro等光损耗测试仪(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克Fluke CFP-100-Q">CFP-100-Q</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-S">CFP-100-S</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-M">CFP-100-M</a></span>)测量衰减的1级测试是认证的方法之一，而使用<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> ?Pro等光时域反射计(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span>)进行2级测试则能够给出光纤通道中每个元件(及光纤、连接器和接头)的衰减，以及也可能影响损耗的事件，例如光纤弯曲。如果没有<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>，就很难发现并修复有些损耗源。为了便于认证，您需要测试仪能够根据IEEE应用标准以及TIA和ISO/IEC规定的布线标准，给出合格或不合格结果。与计算衰减或花费数小时解读OTDR轨迹相比，合格或不合格指示要容易得多、快速得多。幸运的是，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber Pro">CertiFiber Pro</a></span>和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-optifiber-pro-otdr.html" title="福禄克Fluke OptiFiber Pro">OptiFiber Pro</a></span>提供了这种功能。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/10g-fiber.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克CertiFiber PRO 测试中APC与UPC的原文理解(CFP-100-Q,CFP-100-M,CFP-100-S)</title>
		<link>http://www.faxytech.com/archives/apc-upc.html</link>
		<comments>http://www.faxytech.com/archives/apc-upc.html#comments</comments>
		<pubDate>Mon, 19 Sep 2016 13:14:42 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[APC]]></category>
		<category><![CDATA[CFP-100-M]]></category>
		<category><![CDATA[CFP-100-Q]]></category>
		<category><![CDATA[CFP-100-S]]></category>
		<category><![CDATA[UPC]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8079</guid>
		<description><![CDATA[APC connectors and the CertiFiber Pro CertiFiber PRO(CFP-100-Q,CFP-100-M,CFP-100-S)光纤测试仪的APC连接器。 The CertiFiber Pro accepts APC connectors in the?INPUT port ONLY. The APC connector can be attached to the INPUT port because the INPUT p... ]]></description>
			<content:encoded><![CDATA[<div id="kb-article">
<h3 id="article-title"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/apc" title="查看 APC 的全部文章" target="_blank">APC</a></span> connectors and the <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> Pro</h3>
<p>CertiFiber PRO(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克Fluke CFP-100-Q">CFP-100-Q</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-M">CFP-100-M</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-S">CFP-100-S</a></span>)<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>的APC连接器。</p>
<div id="article-body">
<p>The <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber Pro">CertiFiber Pro</a></span> accepts APC connectors in the?INPUT port ONLY. The APC connector can be attached to the INPUT port because the INPUT port is a non-contact mating. This design feature allows you to set a 1 jumper reference for SC, ST, FC, SC/APC and LC/APC fiber testing.</p>
<p>该福禄克FLUKE?CertiFiber PRO(<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-q" title="查看 CFP-100-Q 的全部文章" target="_blank">CFP-100-Q</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-m" title="查看 CFP-100-M 的全部文章" target="_blank">CFP-100-M</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-s" title="查看 CFP-100-S 的全部文章" target="_blank">CFP-100-S</a></span>)光纤测试仪的APC端口，只使用于输入端口。APC端口能够适用于输入端口，因为输入端口是非接触式连接。此设计功能允许您设置光纤测试参考为1个跳接对于SC，ST，FC，SC /APC和LC /?APC</p>
<div id="gt-res-c">
<div id="gt-res-p">
<div id="gt-res-data"></div>
</div>
</div>
<p>The?<strong>OUTPUT port uses a <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/upc" title="查看 UPC 的全部文章" target="_blank">UPC</a></span> connector</strong>. This makes a physical contact with the test reference cord. As a result, you cannot insert SC/APC connectors in the OUTPUT port of the tester. No damage will occur; you will simply get a warning from the tester about the received power being too low.</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/certifiber-port.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8080" title="certifiber APC与UPC端口" src="http://www.faxytech.com/wp-content/uploads/2016/09/certifiber-port.png" alt="certifiber APC与UPC端口" width="268" height="359" /></a></p>
<p>&nbsp;</p>
<p><strong>APC – Angled Physical Contact</strong><br />
These connectors are color coded green and are found in single mode fiber applications. The end face is slanted 8 degrees. The slight angle reduces back reflections in the core because the reflections are absorbed into the cladding. With CertiFiber Pro, you will need two hybrid UPC to APC cords and two APC to APC cords. Details on the methodology can be found in the two links below:</p>
<ul>
<li>Certifying LC/APC links with the CertiFiber Pro</li>
<li>Certifying SC/APC links with the CertiFiber Pro</li>
</ul>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/apc-upc.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8081" title="apc-upc" src="http://www.faxytech.com/wp-content/uploads/2016/09/apc-upc.png" alt="" width="270" height="274" /></a></p>
<p>&nbsp;</p>
<p><strong>UPC – Ultra Physical Contact</strong><br />
These connectors are color coded blue for single mode and beige for multimode. The end face of the fiber has an apex so the core makes direct contact to the other core in a mated connection. A PC (Physical Contact) connector has a flat end face increasing the likelihood that an air gap will be present because the cladding can touch before the core does due to its less rounded end face geometry. That air gap with result in an increase in reflectance &#8211; something fiber systems do not want to see.</p>
<p>拓展阅读：</p>
<p>PC指的是紧密接触（physical contact)，同样是紧密接触，根据<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>的不同，连接器分为PC, SPC，UPC和APC。SPC指的是super physical contact, UPC指的是ultra physical contact。PC, SPC和UPC工业标准规定的回波损耗分别为-35dB, -40dB和-50dB (回波损耗是指有多少比例的光又被连接器的端面反射，回波损耗越小越好，当然你也可以说回波损耗的值越大越好，不考虑前面那个负号）。不同的连接器原则上不能混接，但PC, SPC和UPC的光纤端面都是平面的，差别在磨的质量，所以，PC,SPC和UPC的混连还不至于对连接器形成永久性的物理损伤。<br />
APC则完全不同，它的端面被磨成一个8度角，就是减少反射，其工业标准的回波损耗为-60dB。APC连接器只能与APC相连接。由于APC的结构与PC完全不同，如果用法兰盘将这两种连接器连接，就会损坏连接器的光纤端面。连接APC到PC的办法：通过PC到APC转换的光纤跳线来实现。另外要说明的是APC连接器通常是绿色的（而黄色的光纤则只是单模光纤），而且人眼就能看到光纤端面的倾斜。<br />
因此，为了避免实验过程中连接器使用的混乱（避免毁坏光谱仪等输入端口），今后我们在购买激光器，跳线等时，应统一要求厂家给配APC连接器。<br />
FC/PC FC/UPC FC/APC能够混合连接，信号<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>不会很大，按照国标插损应该是小于0.5dB。应用主要取决于适配器的类型，一般通信ODF架用FC多，设备光口用SC多，ST在局域网和广电较多。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
<div id="article-author">
<p>&nbsp;</p>
</div>
</div>
<p>&nbsp;</p>
<div><span style="color: #4b4b4b; font-family: Verdana, Geneva, Arial, Helvetica, sans-serif; line-height: 18px;"><br />
</span></div>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/apc-upc.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克CertiFiber PRO （CFP-100-Q,CFP-100-M,CFP-100-S)如何认证MPO光纤</title>
		<link>http://www.faxytech.com/archives/certifiber-mpo.html</link>
		<comments>http://www.faxytech.com/archives/certifiber-mpo.html#comments</comments>
		<pubDate>Mon, 22 Aug 2016 01:08:11 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[CertiFiber Pro]]></category>
		<category><![CDATA[CFP-100-M]]></category>
		<category><![CDATA[CFP-100-Q]]></category>
		<category><![CDATA[CFP-100-S]]></category>
		<category><![CDATA[MPO光]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7958</guid>
		<description><![CDATA[本文将为您介绍一种在 MPO 光纤两端使用福禄克CertiFiber PRO （CFP-100-Q,CFP-100-M,CFP-100-S)，从而来认证包含12根多模光纤的 MPO 链路的方法。 同样的方法可用于认证包含8根光纤的 MPO 链路，因为这种... ]]></description>
			<content:encoded><![CDATA[<p>本文将为您介绍一种在 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span> 光纤两端使用<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> PRO （<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克Fluke CFP-100-Q">CFP-100-Q</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-M">CFP-100-M</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-S">CFP-100-S</a></span>)，从而来认证包含12根多模光纤的 MPO 链路的方法。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/08/MPO.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7959" title="fluke CertiFiber PRO测试仪MPO" src="http://www.faxytech.com/wp-content/uploads/2016/08/MPO.png" alt="fluke CertiFiber PRO测试仪MPO" width="608" height="112" /></a></p>
<p>同样的方法可用于认证包含8根光纤的 MPO 链路，因为这种方法需要使用扇形光缆 (LC到MPO)，用户需要了解其安装所需的极性。(使用福禄克公司的 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="MultiFiber Pro">MultiFiber Pro</a></span> 可以更快的得到测试结果，而且 MultiFiber Pro 还可以自动检测出极性。小编将在下一期的文章中介绍如何使用 MultiFiber Pro 来认证 MPO 链路)</p>
<p>&nbsp;</p>
<p>您将会用到以下设备：</p>
<p>- <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-m" title="查看 CFP-100-M 的全部文章" target="_blank">CFP-100-M</a></span> 或者 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-q" title="查看 CFP-100-Q 的全部文章" target="_blank">CFP-100-Q</a></span></p>
<p>- MRC-50EFC-SCLCKIT (1个)</p>
<p>- MRC-50-LCLC (2个)</p>
<p>- 双端 LC 背靠背适配器 (单模)</p>
<p>- MPO母头 to LC 扇形光缆 (2个) &#8211; 可从被测光纤供应商处获得</p>
<p>&nbsp;</p>
<p>此外，仔细的光纤端面检查在这项工作中是极其重要的，没有检查这个环节，你将会得到错误的测试结果。光纤端面检查工作包括MPO和LC连接器的双端连接面。USB FI-1000 光纤端面检查仪 (下图所示) 自带了检查MPO适配器的配件，您可以直接插入到 福禄克CertiFiber PRO （CFP-100-Q,CFP-100-M,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-s" title="查看 CFP-100-S 的全部文章" target="_blank">CFP-100-S</a></span>)的 USB 端口即可使用。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/08/FI1000.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7960" title="福禄克FI1000光纤显微镜 检测MPO" src="http://www.faxytech.com/wp-content/uploads/2016/08/FI1000.jpg" alt="福禄克FI1000光纤显微镜 检测MPO" width="611" height="274" /></a></p>
<p>1、向您的线缆供应商询问的他们的测试极限值。现在我们将会使用TIA-568.3-D多模3跳线参考。也许你曾经被告知：“永远不要用2个或3个跳线参考来进行链路测试”。然而，当MPO干线光纤测试时，就需要3个跳线参考。</p>
<p>注意要选择“No. of Connections/Splices: 4/0，非常重要！</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/08/test-setup.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7961" title="测试仪设置" src="http://www.faxytech.com/wp-content/uploads/2016/08/test-setup.jpg" alt="测试仪设置" width="299" height="404" /></a></p>
<p>&nbsp;</p>
<p>2、在条件允许下，检查并清洁所有的光纤端面。</p>
<p>&nbsp;</p>
<p>3、将 SC to LC EF-TRC 测试跳线 插入到主机和远程单元的输出口 (OUTPUT Ports) ：</p>
<p>(这里不要使用对弯曲不敏感的多模跳线)</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/08/certifiber.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7962" title="certifiber" src="http://www.faxytech.com/wp-content/uploads/2016/08/certifiber.jpg" alt="" width="427" height="274" /></a><img src="data:image/png;base64,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" alt="" /></p>
<p>&nbsp;</p>
<p>4、将主机和远程单元连接在一起：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/08/certifiber-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7963" title="certifiber-2" src="http://www.faxytech.com/wp-content/uploads/2016/08/certifiber-2.jpg" alt="" width="310" height="343" /></a><img src="data:image/png;base64,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" alt="" /></p>
<p>&nbsp;</p>
<p>5、从 Home 主界面开始，依次点击 SET REF (设置参考) &gt; ?OK (好) &gt;?SKIP WIZARD (忽略引导) &gt;?SET REFERENCE (设置参考)。</p>
<p>注意！当您在使用本方法时，不要在<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber Pro">CertiFiber Pro</a></span>点击 RUN WIZARD （运行引导）。</p>
<p>&nbsp;</p>
<p>6、点击 <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span> (下一步) &gt; HOME 键。</p>
<p>&nbsp;</p>
<p>7、当参考结束时，只从输入端口 (INPUT Ports) 断开连接：</p>
<p>&nbsp;</p>
<p>8、在主机的输入端口 (INPUT Port) 中插入一个完好的LC to LC测试参考线：</p>
<p><img src="data:image/png;base64,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" alt="" /></p>
<p>9、在远程单元的输入端口 (INPUT Port) 插入一个完好的LC to LC测试参考线：</p>
<p><img src="data:image/png;base64,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" alt="" /></p>
<p>10、使用一个用于单模的LC 背靠背适配器来连接主机和远程单元 (使用单模是因为能够提供更好的对齐)：</p>
<p><img src="data:image/png;base64,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" alt="" /></p>
<p>11、点击 TEST (测试) 并且确保所报告的损耗小于等于0.15dB。否则停止认证。</p>
<p>(请忽略这里连接器显示屏上所显示的数值，确保每根光纤的损耗都小于等于0.15dB。如此处所示，此处的损耗值是0.05dB和0.04dB，因此我们可以继续进行下一步)。</p>
<p><img src="data:image/png;base64,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" alt="" /><a href="http://www.faxytech.com/wp-content/uploads/2016/08/result.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7964" title="result" src="http://www.faxytech.com/wp-content/uploads/2016/08/result.jpg" alt="" width="330" height="436" /></a></p>
<p>&nbsp;</p>
<p>12、点击 SAVE (保存)，将这些 TRCs 都是小于等于0.15dB的结果记录在案，记得起个好记的名字以便将来可以找到。</p>
<p>13、当两根光纤的损耗值都小于等于0.15dB后，轻按 HOME 键并依次点击 SET REF &gt; OK &gt; SKIP WIZARD (忽略引导) &gt; SET REFERENCE (设置参考值)：</p>
<p>14、参考值设定之后，断开主机和远程单元间的连接：</p>
<p>15、在主机和远程单元之间插入一对LC to LC测试参考线：</p>
<p><img src="data:image/png;base64,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" alt="" /></p>
<p>16、轻按 HOME (主界面) 并点击 TEST (测试) 选项，确保所报告的损耗小于等于0.15dB，否则就无法进行下一步：</p>
<p>17、点击 SAVE (保存)，将刚刚添加的“现场<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>跳线”小于等于0.15dB的结果记录在案，记得起个好记的名字以便将来可以找到。</p>
<p>18、轻按 HOME (主界面) 并依次点击 SET REF &gt; OK &gt; SKIP WIZARD (忽略引导) &gt; SET REFERENCE (设置参考值)。</p>
<p>19、去掉刚刚插入的一对LC to LC 测试参考线</p>
<p>20、将一个 LC to MPO母头 的扇形光纤连接到主机：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/08/certifiber-mpo.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7965" title="certifiber-mpo" src="http://www.faxytech.com/wp-content/uploads/2016/08/certifiber-mpo.jpg" alt="" width="443" height="149" /></a><img src="data:image/png;base64,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" alt="" /></p>
<p>21、将一个LC to MPO母头 的扇形光纤连接到远程单元：<img src="data:image/png;base64,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" alt="" /></p>
<p>22、将您想要认证的MPO线缆连接进去：<img src="data:image/png;base64,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" alt="" /></p>
<p>23、点击 TEST (测试)。</p>
<p>24、点击 SAVE( 保存)来存储两根光纤的损耗值。</p>
<p>25、现在转到测试下一对光纤，完成后可同法测试所有的线对：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/08/certifiber-final.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7966" title="certifiber-final" src="http://www.faxytech.com/wp-content/uploads/2016/08/certifiber-final.jpg" alt="" width="500" height="183" /></a></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/certifiber-mpo.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克CFP-100-Q，CFP-100-M，CFP-100-S光纤一级测试指南</title>
		<link>http://www.faxytech.com/archives/tier1.html</link>
		<comments>http://www.faxytech.com/archives/tier1.html#comments</comments>
		<pubDate>Tue, 15 Sep 2015 02:29:01 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[CFP-100-M]]></category>
		<category><![CDATA[CFP-100-Q]]></category>
		<category><![CDATA[CFP-100-S]]></category>
		<category><![CDATA[光纤一级测试指南]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6765</guid>
		<description><![CDATA[福禄克CFP-100-Q，CFP-100-M，CFP-100-S光纤一级测试指南，控制网络损耗成为网络工程师一项越来越重要的任务，因为损耗预算越来越紧张，而对网络的需求却不断增加，解决这一问题的关键在于做... ]]></description>
			<content:encoded><![CDATA[<p>福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克Fluke CFP-100-Q">CFP-100-Q</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-M">CFP-100-M</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-S">CFP-100-S</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e4%b8%80%e7%ba%a7%e6%b5%8b%e8%af%95%e6%8c%87%e5%8d%97" title="查看 光纤一级测试指南 的全部文章" target="_blank">光纤一级测试指南</a></span>，控制网络损耗成为网络工程师一项越来越重要的任务，因为损耗预算越来越紧张，而对网络的需求却不断增加，解决这一问题的关键在于做好光纤的损耗测试。小编建议您，损耗测试要在每次安装光纤链路后进行，以确保安装工作满足布线基础设施标准规定的光纤损耗预算要求。</p>
<p><img class="alignnone" title="福禄克CFP-100-Q，CFP-100-M，CFP-100-S光纤一级测试指南" src="http://www.faxytech.com/wp-content/uploads/2013/06/CertiFiber.jpg" alt="福禄克CFP-100-Q，CFP-100-M，CFP-100-S光纤一级测试指南" width="293" height="231" /></p>
<p><img src="file:///d:/users/administrator/appdata/roaming/360se6/User Data/temp/CertiFiber.jpg" alt="" /></p>
<p><strong>最佳实践2：损耗/长度光纤测试（1级认证）</strong></p>
<p>光纤测试要符合TIA-568-C、ISO/IEC-11801和ISO/IEC14673-3等国际公认标准的要求，以便确保高质量安装。</p>
<p><strong>选择适用的工具</strong></p>
<ul>
<li>在两个方向自动测量双芯光纤，首选光纤损耗测试仪(OLTS)。</li>
<li>手动，测量单根光纤通路，可选光源/功率计(LSPM)套件和可视故障定位仪。</li>
</ul>
<p>&nbsp;</p>
<p><strong>1</strong><strong>级光纤认证步骤</strong></p>
<ul>
<li>测试之前，利用一根测试参考线(TRC)、一根损耗已知(可以忽略不计)的转接线将稳定的光源连接至功率计</li>
<li>设置和记录光源的参考功率水平，并将其作为随后进行的功率损耗测量的基线</li>
<li>断开功率计上的TRC，将第二根TRC连接至功率计端口。利用精密的隔板接头将两根TRC连接在一起</li>
<li>测量损耗，确保TRC良好（多模，≤0.15 dB；单模，≤ 0.25 dB），并保存测试</li>
<li>断开隔板接头，连接被测链路，测量损耗</li>
<li>OLTS将依据标准和被测长度显示“合格”或“不合格”结果。LSPM将只测量损耗（需要手动计算限值和裕量）</li>
</ul>
<p>注：使用LSPM，而不是类似于<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> Pro（<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-q" title="查看 CFP-100-Q 的全部文章" target="_blank">CFP-100-Q</a></span>单多模，<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-s" title="查看 CFP-100-S 的全部文章" target="_blank">CFP-100-S</a></span>单模，<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-m" title="查看 CFP-100-M 的全部文章" target="_blank">CFP-100-M</a></span>多模）的OLTS时，还需要可视故障定位仪、光纤长度计和进行手动计算。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/tier1.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克CertiFiber PRO（CFP-100-Q,CFP-100-M,CFP-100-S)如何选择跳线和转换接头？</title>
		<link>http://www.faxytech.com/archives/certifiber-tx.html</link>
		<comments>http://www.faxytech.com/archives/certifiber-tx.html#comments</comments>
		<pubDate>Mon, 01 Jun 2015 00:55:45 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[CertiFiber Pro]]></category>
		<category><![CDATA[CFP-100-M]]></category>
		<category><![CDATA[CFP-100-Q]]></category>
		<category><![CDATA[CFP-100-S]]></category>
		<category><![CDATA[跳线]]></category>
		<category><![CDATA[转换接头]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6274</guid>
		<description><![CDATA[福禄克CertiFiber?PRO如何选择跳线和转换接头？ 无论是福禄克CertiFiber?PRO中的CFP-100-Q还是CFP-100-M，CFP-100-S光纤测试仪标配都是LC接头解决方案。那么如果要测试SC，ST，FC接头如何选配跳线和转换接... ]]></description>
			<content:encoded><![CDATA[<p>福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span>?PRO<span style="font-family: 宋体;">如何选择<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%b7%b3%e7%ba%bf" title="查看 跳线 的全部文章" target="_blank">跳线</a></span>和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%bd%ac%e6%8d%a2%e6%8e%a5%e5%a4%b4" title="查看 转换接头 的全部文章" target="_blank">转换接头</a></span>？</span></p>
<p>无论是福禄克<span style="font-family: 'Times New Roman';">CertiFiber?PRO</span><span style="font-family: 宋体;">中的</span><span style="font-family: 'Times New Roman';"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克Fluke CFP-100-Q">CFP-100-Q</a></span></span><span style="font-family: 宋体;">还是</span><span style="font-family: 'Times New Roman';"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-M">CFP-100-M</a></span></span><span style="font-family: 宋体;">，</span><span style="font-family: 'Times New Roman';"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-S">CFP-100-S</a></span></span><span style="font-family: 宋体;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>标配都是</span><span style="font-family: 'Times New Roman';">LC</span><span style="font-family: 宋体;">接头解决方案。那么如果要测试</span><span style="font-family: 'Times New Roman';">SC</span><span style="font-family: 宋体;">，</span><span style="font-family: 'Times New Roman';">ST</span><span style="font-family: 宋体;">，</span><span style="font-family: 'Times New Roman';">FC</span><span style="font-family: 宋体;">接头如何选配跳线和转换接头呢？</span></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/06/certifiber-pro.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-6275" title="福禄克FLuke certifiber pro 光纤测试仪" src="http://www.faxytech.com/wp-content/uploads/2015/06/certifiber-pro.png" alt="福禄克FLuke certifiber pro 光纤测试仪" width="531" height="240" /></a></p>
<p>前沿：首先分单模和多模之分。</p>
<p>例如：多模50??ST<span style="font-family: 宋体;">解决方案。 </span></p>
<p>ST<span style="font-family: 宋体;">的跳线应该选择：</span><span style="font-family: 'Times New Roman';">MRC-50EFC-SCSTKIT</span></p>
<p>&nbsp;</p>
<table>
<tbody>
<tr>
<td width="133" valign="center">MRC-50EFC-SCSTKIT</td>
<td width="430" valign="center">用于测试?<span style="font-family: Arial;">50um?ST </span><span style="font-family: 宋体;">端接光纤（</span><span style="font-family: Arial;">2?SC/ST</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">2?ST/ST</span><span style="font-family: 宋体;">）的多模式环型通量兼容测试参考导线工具包 </span><span style="font-family: Arial;">(2m)</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>光纤跳线的组成是：<span style="font-family: 'Times New Roman';">2?SC/ST</span><span style="font-family: 宋体;">、</span><span style="font-family: 'Times New Roman';">2?ST/ST </span><span style="font-family: 宋体;">。所以我们还需要购买</span><span style="font-family: 'Times New Roman';">2</span><span style="font-family: 宋体;">个</span><span style="font-family: 'Times New Roman';">ST</span><span style="font-family: 宋体;">转换器用于光功率接口。型号为：</span><span style="font-family: 'Times New Roman';">NFA-ST</span><span style="font-family: 宋体;">。</span></p>
<p>&nbsp;</p>
<table>
<tbody>
<tr>
<td width="288" valign="center">NFA-ST</td>
<td width="288" valign="center">2?<span style="font-family: 宋体;">件套装用于 </span><span style="font-family: Arial;">CFP </span><span style="font-family: 宋体;">功率计端口的 </span><span style="font-family: Arial;">ST </span><span style="font-family: 宋体;">可互换的适配器。</span></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>同理：多模<span style="font-family: 'Times New Roman';">62.5</span><span style="font-family: 宋体;">解决方案。（</span>注意标配已含<span style="font-family: 'Times New Roman';">LC</span><span style="font-family: 宋体;">，就可以不配</span>）</p>
<p>&nbsp;</p>
<p><strong>第一：跳线选择。</strong></p>
<table>
<tbody>
<tr>
<td width="288" valign="center">MRC-625EFC-SCLCKIT</td>
<td width="288" valign="center">用于测试?<span style="font-family: Arial;">62.5um?LC </span><span style="font-family: 宋体;">端接光纤（</span><span style="font-family: Arial;">2?SC/LC</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">2?LC/LC</span><span style="font-family: 宋体;">）的多模式环型通量兼容测试参考导线工具包 </span><span style="font-family: Arial;">(2m)</span></td>
</tr>
<tr>
<td width="288" valign="center">MRC-625EFC-SCSCKIT</td>
<td width="288" valign="center">用于测试?<span style="font-family: Arial;">62.5um?SC </span><span style="font-family: 宋体;">端接光纤（</span><span style="font-family: Arial;">4?SC/SC</span><span style="font-family: 宋体;">）的符合多模环通量的测试参考线工具包 </span><span style="font-family: Arial;">(2m)</span></td>
</tr>
<tr>
<td width="288" valign="center">MRC-625EFC-SCSTKIT</td>
<td width="288" valign="center">用于测试?<span style="font-family: Arial;">62.5um?ST </span><span style="font-family: 宋体;">端接光纤（</span><span style="font-family: Arial;">2?SC/ST</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">2?ST/ST</span><span style="font-family: 宋体;">）的多模式环型通量兼容测试参考导线工具包 </span><span style="font-family: Arial;">(2m)</span></td>
</tr>
<tr>
<td width="288" valign="center">MRC-625EFC-SCFCKIT</td>
<td width="288" valign="center">用于测试?<span style="font-family: Arial;">62.5um?FC </span><span style="font-family: 宋体;">端接光纤（</span><span style="font-family: Arial;">2?SC/LC</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">2?FC/FC</span><span style="font-family: 宋体;">）的多模式环型通量兼容测试参考导线工具包 </span><span style="font-family: Arial;">(2m)</span></td>
</tr>
</tbody>
</table>
<p><strong>第二：转换接头：NFA-LC???NFA-SC?????NFA-ST????NFA-FC</strong></p>
<p>&nbsp;</p>
<p>单模光纤跳线解决方案如下：</p>
<table>
<tbody>
<tr>
<td width="288" valign="center">SRC-9-SCSC-KIT</td>
<td width="288" valign="center">单模测试参考线工具包?<span style="font-family: Arial;">(2m)</span><span style="font-family: 宋体;">，用于测试 </span><span style="font-family: Arial;">SC </span><span style="font-family: 宋体;">端接光纤 </span><span style="font-family: Arial;">(4?SC/SC)</span></td>
</tr>
<tr>
<td width="288" valign="center">SRC-9-SCLC-KIT</td>
<td width="288" valign="center">用于测试?<span style="font-family: Arial;">LC </span><span style="font-family: 宋体;">端接光纤（</span><span style="font-family: Arial;">2?SC/LC</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">2?LC/LC</span><span style="font-family: 宋体;">）的单模测试参考线工具包 </span><span style="font-family: Arial;">(2m) </span></td>
</tr>
<tr>
<td width="288" valign="center">SRC-9-SCFC-KIT</td>
<td width="288" valign="center">用于测试?<span style="font-family: Arial;">FC </span><span style="font-family: 宋体;">端接光纤（</span><span style="font-family: Arial;">2?SC/FC</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">2?FC/FC</span><span style="font-family: 宋体;">）的单模测试参考线工具包 </span><span style="font-family: Arial;">(2m)</span></td>
</tr>
<tr>
<td width="288" valign="center">SRC-9-SCST-KIT</td>
<td width="288" valign="center">用于测试?<span style="font-family: Arial;">ST </span><span style="font-family: 宋体;">端接光纤（</span><span style="font-family: Arial;">2?SC/ST</span><span style="font-family: 宋体;">、</span><span style="font-family: Arial;">2?ST/ST</span><span style="font-family: 宋体;">）的单模测试参考线工具包 </span><span style="font-family: Arial;">(2m)</span></td>
</tr>
</tbody>
</table>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/06/SRC-9-SCLC-KIT.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-6276" title="SRC-9-SCLC-KIT单模光纤跳线" src="http://www.faxytech.com/wp-content/uploads/2015/06/SRC-9-SCLC-KIT.png" alt="" width="675" height="508" /></a></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/06/SRC-9-SCLC-KIT.png" class="highslide-image" onclick="return hs.expand(this);"></a>PS：注意不要忘了光纤接头哦。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/certifiber-tx.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克FLuke CertiFiber PRO(CFP-100-M,-S,-Q)光纤测试仪视频教程</title>
		<link>http://www.faxytech.com/archives/certifiber-video.html</link>
		<comments>http://www.faxytech.com/archives/certifiber-video.html#comments</comments>
		<pubDate>Wed, 30 Jul 2014 06:31:58 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[CertiFiber Pro]]></category>
		<category><![CDATA[CFP-100-M]]></category>
		<category><![CDATA[福禄克视频]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=4360</guid>
		<description><![CDATA[福禄克FLuke CertiFiber PRO光纤测试仪视频，FLuke?DTX-1800已经风靡世界十多年，基于这一点，福禄克网络推出DSX系列（DSX-5000）就必然受到全球瞩目，DSX-5000不仅满足了现场的测试要求，即能根据客户... ]]></description>
			<content:encoded><![CDATA[<p>福禄克FLuke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> PRO<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>视频，FLuke?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>已经风靡世界十多年，基于这一点，福禄克网络推出DSX系列（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>）就必然受到全球瞩目，DSX-5000不仅满足了现场的测试要求，即能根据客户需求制定规则和项目，而加快了我们的测试进程，FLUKE DSX5000测试仪品质良好，使用非常方便，DSX最使人印象深刻的是它3秒能建立光纤连接。DSX-5000 9秒能建立<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>连接。作为福禄克网络代理深圳连讯公司常常把我们的好产品推荐给我们的重要客户。</p>
<p>福禄克DSX-5000配合CFP-Q-ADD就能测试光纤，深圳连讯推荐福禄克网络CertiFiber PRO光纤测试视频，更多操作问题可以联系连讯公司。</p>
<h4>福禄克Fluke CertiFiber PRO核心思想，主题功能概览：</h4>
<div>1、适用于所有<a title="铜缆测试仪" href="http://www.faxytech.com/products/testers/cable">铜缆</a>和光纤认证作业的更快速的系统验收。</div>
<div>2、ProjeX? 系统可管理作业要求和从设定到系统验收的整个流程，进而确保正确完成所有测试</div>
<div>3、Taptive? 用户界面可简化设定、消除错误并加速故障排除。</div>
<div>4、分析测试结果并运用?<a title="fluke LinkWare" href="http://www.faxy.com.cn/down/down1.html">LinkWare</a><sup>TM</sup>管理软件为铜线和光纤 (OLTS /?<a title="DTX OTDR" href="http://www.faxytech.com/archives/dtx-otdr.html">OTDR</a>) 创建专业测试报告</div>
<div>5、切换介质、测试类型或项目，而不损失您的作业空间</div>
<div>6、其设计一体化、模块化且着眼于未来，具有行业领先的铜缆和光纤布线认证和故障排除功能</div>
<div>7、提供有线和 Wi-Fi 网络故障处理模块</div>
<p><span style="color: #800000;">视频截图：</span><a href="http://www.faxytech.com/wp-content/uploads/2014/07/CertiFiber-PRO-Video.jpg"><br />
<img class="alignnone size-full wp-image-4361" title="CertiFiber PRO 光纤测试视频" src="http://www.faxytech.com/wp-content/uploads/2014/07/CertiFiber-PRO-Video.jpg" alt="CertiFiber PRO 光纤测试视频" width="643" height="481" /></a></p>
<p>视频地址：<a href="http://synocomm.gensee.com/webcast/site/vod/play-237cc825b9b4491689ce3cf80b14a58c?nickName=www.faxytech.com">http://synocomm.gensee.com/webcast/site/vod/play-237cc825b9b4491689ce3cf80b14a58c?nickName=www.faxytech.com</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/certifiber-video.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【福禄克】Fluke CertiFiber Pro(CFP-100-Q,CFP-100-M,CFP-100-S) 光纤测试仪</title>
		<link>http://www.faxytech.com/archives/certifiber-pro.html</link>
		<comments>http://www.faxytech.com/archives/certifiber-pro.html#comments</comments>
		<pubDate>Thu, 13 Jun 2013 03:10:39 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[福禄克光缆测试产品]]></category>
		<category><![CDATA[CertiFiber Pro]]></category>
		<category><![CDATA[CFP-100-M]]></category>
		<category><![CDATA[CFP-100-Q]]></category>
		<category><![CDATA[CFP-100-S]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[OTDR]]></category>
		<category><![CDATA[Versiv]]></category>
		<category><![CDATA[光纤损耗测试仪]]></category>
		<category><![CDATA[光纤测试仪]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=2990</guid>
		<description><![CDATA[深圳连讯（0755-83999818）有20年福禄克网络Fluke Networks仪表销售经验，价格全国最低，技术服务一流。福禄克Versiv 系列全新上市 CertiFiber Pro（ CFP-100-Q,CFP-100-M,CFP-100-S）热火销售中。 【福禄克】Fluk... ]]></description>
			<content:encoded><![CDATA[<p>深圳连讯（0755-83999818）有20年<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>网络<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span>仪表销售经验，价格全国最低，技术服务一流。福禄克<span style="font-size: 2em; font-weight: normal;"><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> </span><span style="font-size: 1em; font-weight: normal;">系列全新上市 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> Pro（ </span><span style="font-size: 1em;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克Fluke CFP-100-Q">CFP-100-Q</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-M">CFP-100-M</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克FLuke CFP-100-S">CFP-100-S</a></span>）热火销售中。</span></p>
<h4>【福禄克】<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fluke" title="查看 Fluke 的全部文章" target="_blank">Fluke</a></span> <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber Pro">CertiFiber Pro</a></span>(<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-q" title="查看 CFP-100-Q 的全部文章" target="_blank">CFP-100-Q</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-m" title="查看 CFP-100-M 的全部文章" target="_blank">CFP-100-M</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp-100-s" title="查看 CFP-100-S 的全部文章" target="_blank">CFP-100-S</a></span>) <span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>产品概述：</h4>
<h1><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/versiv" title="查看 Versiv 的全部文章" target="_blank">Versiv</a></span> Cabling Certification</h1>
<div><a href="http://www.faxytech.com/wp-content/uploads/2013/06/CertiFiber.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="size-full wp-image-2999 alignright" title="福禄克Fluke CertiFiber PRO光纤测试仪" src="http://www.faxytech.com/wp-content/uploads/2013/06/CertiFiber.jpg" alt="福禄克Fluke CertiFiber PRO光纤测试仪" width="316" height="249" /></a></div>
<div>1、适用于所有<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>和光纤认证作业的更快速的系统验收。</div>
<div>2、ProjeX? 系统可管理作业要求和从设定到系统验收的整个流程，进而确保正确完成所有测试</div>
<div>3、Taptive? 用户界面可简化设定、消除错误并加速故障排除。</div>
<div>4、分析测试结果并运用 <span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span><sup>TM</sup>管理软件为铜线和光纤 (OLTS / <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>) 创建专业测试报告</div>
<div>5、切换介质、测试类型或项目，而不损失您的作业空间</div>
<div>6、其设计一体化、模块化且着眼于未来，具有行业领先的铜缆和光纤布线认证和故障排除功能</div>
<div>7、提供有线和 Wi-Fi 网络故障处理模块</div>
<h4>【福禄克】Fluke <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/certifiber-pro" title="查看 CertiFiber Pro 的全部文章" target="_blank">CertiFiber Pro</a></span>(CFP-100-Q,CFP-100-M,CFP-100-S) <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e6%b5%8b%e8%af%95%e4%bb%aa" title="查看 光纤测试仪 的全部文章" target="_blank">光纤测试仪</a></span>产品功能特性：</h4>
<div id="14728a">
<p><strong>独特功能：</strong></p>
<ul>
<li> 与以前使用的<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="电缆测试仪">电缆测试仪</a></span>相比，Versiv 能使用户完成更多的作业，加速完成测试过程的每个步骤</li>
<li> ProjX 管理系统使从初始设置到系统验收整个过程的工作变得简便易行。它避免了一些冗余步骤，并可确保所有测试均能一次性正确完成</li>
<li> 通过 Taptive 用户界面，各种技术水平的技术人员进行高级数据分析、以及安装和操作易如反掌。</li>
<li> LinkWare 管理软件可提供一流的测试结果分析和专业的测试报告</li>
</ul>
</div>
<div id="14729a">
<p><strong>标准：</strong></p>
<ul>
<li> 配合 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span>? Pro <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/otdr" title="查看 OTDR 的全部文章" target="_blank">OTDR</a></span> 使用时，可合并 OLTS 第 1 层（基本层）、OTDR 第 2 层（扩展层）认证、端面检测和报告</li>
<li> 设置参考向导可根据 ISO/IEC 验证测试参考导线 (TRC) 14763-3 并避免负损耗错误</li>
<li> ANSI/TIA 和 ISO/IEC 标准需要符合环形通量要求的光发射条件</li>
</ul>
</div>
<p><a name="14730"></a></p>
<div id="14730q">
<div><strong>性能：</strong></div>
</div>
<div id="14730a">
<ul>
<li> 三秒自动测试 — （比传统测试仪快四倍）包括：对两种波长的两根光纤进行光损耗测量，以及距离测量和光损耗预算计算</li>
<li> 提供根据产业标准或定制测试限值进行的自动通过/失败分析</li>
<li> 识别造成“负损耗”结果的不正确测试程序</li>
<li> 板载 (USB) 检测相机记录光纤端面图像</li>
<li> 所有典型连接器类型（SC、ST、LC 和 FC）均可使用的可互换功率计适配器，实现最准确的单一跳线参考法</li>
<li> 内置视频故障定位器，可用于执行基本诊断和极性检测</li>
<li> 在单个光纤上的双波长测量功能使测试仪可以用于只需一个光纤链路的应用中。</li>
<li> 无需其他设备或流程即可符合 TIA-526-14-B 和 IEC 61280-4-1 环形通量要求</li>
</ul>
</div>
<div id="14760q">
<p><strong>ProjX? 管理系统</strong></p>
</div>
<div id="14760a">
<p><a title="福禄克FLuke Versiv" href="http://www.faxytech.com/archives/fluke-versiv.html">Versiv</a> 的 ProjX? 系统可管理从设置到系统验收过程的作业，确保正确完成所有的测试。输入作业的测试详情后，ProjX 会将其储存在一个用整个团队容易理解的名称命名的项目文件中。更改模块或作业时，无需重新输入详情。通过利用 U 盘或电子邮件分享测试限制、电缆类型和测试结果，为执行相同作业的多个测试仪提供支持。简便且高效。</p>
</div>
<div id="14761q">
<p><strong><a title="查看 Taptive 的全部文章" href="http://www.faxytech.com/tag/taptive" target="_blank">Taptive</a>? 用户界面</strong></p>
</div>
<div id="14761a">
<p><a title="福禄克FLuke Versiv" href="http://www.faxytech.com/archives/fluke-versiv.html">Versiv</a> 由现场测试仪的最高级用户界面?<a title="查看 Taptive 的全部文章" href="http://www.faxytech.com/tag/taptive" target="_blank">Taptive</a> 驱动。凭借基于手势指示的界面，各种技术水平的技术人员和项目经理能避免代价不菲的错误，并通过减少击键操作、设置向导、刷卡、缩放来提高作业速度，还可以随时获取更多数据。</p>
<p>现在，您可以像使用智能手机那样轻松地测试多个介质类型和要求。只需选择您正在进行的 ProjX 作业，大显示屏就会确认需要执行的测试。<a title="查看 Taptive 的全部文章" href="http://www.faxytech.com/tag/taptive" target="_blank">Taptive</a> 有助于您更快速、轻松地接入整个布线基础设施。</p>
<table>
<tbody>
<tr>
<td><a href="http://www.faxytech.com/wp-content/uploads/2013/06/Versiv.jpg" class="highslide-image" onclick="return hs.expand(this);"><img title="Versiv" src="http://www.faxytech.com/wp-content/uploads/2013/06/Versiv.jpg" alt="Versiv" width="360" height="479" /></a></td>
</tr>
<tr>
<td align="right"><a title="查看 Taptive 的全部文章" href="http://www.faxytech.com/tag/taptive" target="_blank">Taptive</a> 用户界面可简化设置，<br />
消除错误和加快故障排除。</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>
<div id="14765q">
<p><strong><a title="福禄克导数据软件" href="http://www.faxytech.com/archives/linkware-6-2.html">LinkWare</a>? 管理软件</strong></p>
</div>
<div id="14765a">
<p>项目经理有全面的工作流程监控和测试结果整合功能。</p>
<p><a title="福禄克导数据软件" href="http://www.faxytech.com/archives/linkware-6-2.html">LinkWare</a> 将数据收集到便于客户理解的单一报告中，突出展现质量和工艺。<a title="福禄克导数据软件" href="http://www.faxytech.com/archives/linkware-6-2.html">LinkWare</a> Stats 提供将测试结果转化为图形的自动统计报告，直观展示性能。该报告甚至能以一种压缩、图形化的格式汇总完整的布线和光纤基础设施，以便轻松检验余量和不规则点。</p>
<table>
<tbody>
<tr>
<td><a href="http://www.faxytech.com/wp-content/uploads/2013/06/LinkWare1.jpg" class="highslide-image" onclick="return hs.expand(this);"><img title="LinkWare" src="http://www.faxytech.com/wp-content/uploads/2013/06/LinkWare1.jpg" alt="LinkWare" width="600" height="423" /></a></td>
</tr>
<tr>
<td align="right"><a title="福禄克导数据软件" href="http://www.faxytech.com/archives/linkware-6-2.html">LinkWare</a> 可以快速创建<br />
易于客户理解的完全集成报告</td>
</tr>
</tbody>
</table>
</div>
<p><strong>Linkware 8.0 软件下载地址：<a href="http://www.faxy.com.cn/down/down1.html"><span style="color: #ff0000;">http://www.faxy.com.cn/down/down1.html</span></a></strong></p>
<div>
<h4>【福禄克】Fluke CertiFiber Pro(CFP-100-Q,CFP-100-M,CFP-100-S) 光纤测试仪技术规格：<span style="font-weight: normal;"> </span></h4>
</div>
<table border="0" cellspacing="0" cellpadding="2" bordercolor="black">
<tbody>
<tr>
<td colspan="2" bgcolor="#cccccc"><strong>功率表规格</strong></td>
</tr>
<tr bgcolor="#efefef">
<td>输入连接器</td>
<td>可互换的接头适配器（LC 标准、SC、ST 和 FC 可选）</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>探测器类型</td>
<td>InGaAs</td>
</tr>
<tr bgcolor="#efefef">
<td>波长</td>
<td>850 nm、1300 nm、1310 nm、1550 nm</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>功率测量范围</td>
<td>0 dBm 至 -65 dBm (850 nm) 0 dBm 至 -70 dBm（所有其他波长）</td>
</tr>
<tr bgcolor="#efefef">
<td>功率测量的不确定性<sup>1,2</sup></td>
<td>&lt; +/- 5% +/- 32 pW</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>测量的线性度<sup>3</sup></td>
<td>&lt; ± 0.1 dB</td>
</tr>
<tr bgcolor="#efefef">
<td>重新<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>周期</td>
<td>一年</td>
</tr>
<tr bgcolor="#f7f7f7">
<td colspan="2"><span style="font-size: xx-small;">1.+/- 100 pW @ 850 nm<br />
2.在以下条件下：功率水平 100 μW (-10 dBm)，连续波 (CW)，吸收功率 850 nm 和 1310 nm。发散光束，50/125 μm 时 NA = 0.20，9/125 时 μm NA = 0.14。环境<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span> 23° ± 1°C。带陶瓷插芯的 SC/UPC 连接器。5 分钟预热时间后。符合 NIST 的要求。<br />
3.850 nm 和 1310 nm 时为 -3 dBm 至 -55 dBm。环境温度 23° ± 1°C。5 分钟预热时间后。</span></td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="2" bordercolor="black">
<tbody>
<tr>
<td colspan="3" bgcolor="#cccccc"><strong>损耗/长度规格</strong></td>
</tr>
<tr bgcolor="#efefef">
<td><strong>技术规格</strong></td>
<td><strong>CertiFiber Pro 多模模块</strong></td>
<td><strong>CertiFiber Pro 单模模块</strong></td>
</tr>
<tr bgcolor="#f7f7f7">
<td>测试速度（不包括参考时间）</td>
<td colspan="2">智能远端模式：&lt; 3 秒 （2 波长，单向，自动波长检测）<br />
远端信号源模式：≤ 2 秒 （2 波长，单向，自动波长检测）<br />
环回模式：≤ 2 秒 （2 波长，单向，自动波长检测）</td>
</tr>
<tr bgcolor="#efefef">
<td>输入/输出连接器</td>
<td colspan="2">可互换的接头适配器（LC 标准、SC、ST 和 FC 可选）</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>启动条件<sup>1,2</sup></td>
<td colspan="2">符合 TIA-526-14-B、ISO/IEC 14763-3 和 IEC 61280-4-1 合规性要求的环型通量</td>
</tr>
<tr bgcolor="#efefef">
<td>所测光纤类型</td>
<td>50/125 ?m 或 62.5/125 ?m</td>
<td>单模</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>光源类型和波长</td>
<td>LED 光源 850 nm ± 30 nm 1300 nm ± 20 nm</td>
<td>Fabry-Perot 激光二极管 1310 nm ± 20 nm 1550 nm ± 30 nm</td>
</tr>
<tr bgcolor="#efefef">
<td>最大长度测量</td>
<td>12 km</td>
<td>130 km</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>长度测量的准确性</td>
<td>± 1.5 m ± 长度的 1 %</td>
<td>± 1.5 m ± 长度的 1 %</td>
</tr>
<tr bgcolor="#efefef">
<td>输出功率（额定）</td>
<td>≥ -24 dBm，EF-TRC</td>
<td>≥ -4 dBm</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>输出功率稳定性<sup>3</sup></td>
<td>8 小时内 ± 0.05 dB，15分钟内 ± 0.03 dB</td>
<td>8 小时内 ± 0.1 dB，15分钟内 ± 0.08 dB</td>
</tr>
<tr bgcolor="#efefef">
<td colspan="3"><span style="font-size: xx-small;">1.EF-TRC 输出<br />
2.EF 测试设备之间可能会出现差异，但 EF 合规性可有 95% 的置信系数<br />
3.15 分钟预热后与功率水平有关 – 常温</span></td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="2" bordercolor="black">
<tbody>
<tr>
<td colspan="3" bgcolor="#cccccc"><strong>损耗/长度规格（待续）</strong></td>
</tr>
<tr bgcolor="#efefef">
<td>光源波长</td>
<td>850 nm、1300 nm、1310 nm、1550 nm</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>功率测量范围</td>
<td>0 dBm 至 -65 dBm (850 nm) 0 dBm 至 -70 dBm（所有其他波长）</td>
</tr>
<tr bgcolor="#efefef">
<td>功率测量的不确定性?<sup>2，3</sup></td>
<td>&lt; +/- 5% +/- 32 pW</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>测量的线性度<sup>4</sup></td>
<td>&lt; ± 0.1 dB</td>
</tr>
<tr bgcolor="#efefef">
<td>重新校准周期</td>
<td>一年</td>
</tr>
<tr bgcolor="#f7f7f7">
<td colspan="3"><span style="font-size: xx-small;">1.在常温下，15 分钟预热后与功率水平有关。<br />
2.+/- 100 pW @ 850 nm<br />
3.在以下条件下：功率水平 100 μW (-10 dBm)，连续波 (CW)，吸收功率 850 nm 和 1310 nm。发散光束，50/125 μm 时 NA = 0.20，9/125 时 μm NA = 0.14。环境温度 23° ± 1°C。带陶瓷插芯的 SC/UPC 连接器。5 分钟预热时间后。符合 NIST 的要求。<br />
4.850 nm 和 1310 nm 时为 -3 dBm 至 -55 dBm。环境温度 23° ± 1°C。5 分钟预热时间后。</span></td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="2" bordercolor="black">
<tbody>
<tr>
<td colspan="2" bgcolor="#cccccc"><strong>所选规范</strong></td>
</tr>
<tr>
<td colspan="2" bgcolor="#efefef"><strong>可视化故障定位器 (VFL)</strong></td>
</tr>
<tr bgcolor="#f7f7f7">
<td><strong>标题</strong></td>
<td><strong>要求</strong></td>
</tr>
<tr bgcolor="#efefef">
<td>输出功率</td>
<td>&gt;-5 dBm<br />
&lt;0 dBm<br />
SMF-28 单模光纤<br />
连续波<br />
SC/UPC 连接器</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>工作波长</td>
<td>650 nm 额定</td>
</tr>
<tr bgcolor="#efefef">
<td>输出模式</td>
<td>连续波<br />
脉冲模式（2 Hz &#8211; 3 Hz 闪烁频率）</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>接头适配器</td>
<td>2.5 mm 通用</td>
</tr>
<tr bgcolor="#efefef">
<td>激光安全</td>
<td>II 类 CDRH<br />
超过操作温度范围</td>
</tr>
</tbody>
</table>
<table border="0" cellspacing="0" cellpadding="2" bordercolor="black">
<tbody>
<tr>
<td colspan="2" bgcolor="#cccccc"><strong>环境规格</strong></td>
</tr>
<tr bgcolor="#efefef">
<td><strong>标题</strong></td>
<td><strong>要求</strong></td>
</tr>
<tr bgcolor="#f7f7f7">
<td>操作温度</td>
<td>-18° C 至 45° C</td>
</tr>
<tr bgcolor="#efefef">
<td>贮存温度</td>
<td>-30° C 至 +60° C</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>相对工作湿度&nbsp;</p>
<p>&nbsp;</p>
<p>% 相对湿度，无冷凝</td>
<td>0 % &#8211; 90 %，32 °F &#8211; 95 °F (0° C &#8211; 35° C)<br />
0 % &#8211; 70 %，95 °F &#8211; 113 °F (35° C &#8211; 45° C)</td>
</tr>
<tr bgcolor="#efefef">
<td>振动</td>
<td>随机、2 g、5 Hz-500 Hz</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>冲击</td>
<td>1 米跌落试验（无论是否带有模块和适配器）</td>
</tr>
<tr bgcolor="#efefef">
<td>安全</td>
<td>CSA C22.2 No. 1,010.1：1992<br />
EN 61010-1 第 1 版 + 第 1 次修订，2</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>污染等级</td>
<td>2</td>
</tr>
<tr bgcolor="#efefef">
<td>海拔</td>
<td>工作时：4,000 米；贮存时：12,000 米</td>
</tr>
<tr bgcolor="#f7f7f7">
<td>EMC</td>
<td>EN 61326–1</td>
</tr>
</tbody>
</table>
<h4>【福禄克】Fluke CertiFiber Pro(CFP-100-Q,CFP-100-M,CFP-100-S) 光纤测试仪选型指南：</h4>
<div>型号</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>CFP-100-M</td>
<td>1 个 Versiv 主机和远端、 (2) 个 CertiFiber Pro Multimode OLTS 模块、SC/LC 符合 EF 标准 MM TRC 工具包 50 um、TRC 便携包、(2) 个 SC/SC 适配器、(2) 个手拎带、(2) 个肩带、便携包、USB 接口电缆、LinkWare? 软件 CD、用户手册 CD、(2) 个交流电充电器、校准说明和入门指南。</td>
</tr>
<tr>
<td>CFP-100-S</td>
<td>1 个 Versiv? 主机与远端、(2) 个 CertiFiber Pro Singlemode OLTS 模块、SC/LC SM TRC 工具包、TRC 便携包、(2) 个 LC/LC 适配器、(2) 个手拎带、(2) 个肩带、便携包、USB 接口电缆、LinkWare 软件 CD、用户手册 CD、(2) 个交流电充电器、校准说明和入门指南。</td>
</tr>
<tr>
<td>CFP-100-Q</td>
<td>1 个 Versiv 主机和远端、(2) 个 CertiFiber Pro Quad OLTS 模块、SC/LC 符合 EF 标准 MM TRC 工具包 50 ?m、SC/LC SM TRC 工具包、TRC 便携包、(2) 个 LC/LC Simplex 适配器、(2) 手拎带、(2) 个肩带、便携包、USB 接口电缆、LinkWare 软件 CD、用户手册 CD、(2) 个交流电充电器、 校准说明和入门指南。</td>
</tr>
<tr>
<td><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-cfp-mi.html" title="福禄克FLuke OFP-CFP-MI">OFP-CFP-MI</a></span></td>
<td>1 个 Versiv 主机与远端、(2) 个 CertiFiber Pro Quad OLTS 模块、OptiFiber Quad OTDR 模块、(2) 个 手拎带、(2) 个肩带、(2) 个便携包、USB 接口电缆、LinkWare 软件 CD、 用户手册 CD、(2) 个交流适配器、(2) 个一键式清洁器 (1.25/2.50 mm)、2 根 SC/LC 多模发射电缆—50 ?m、 1 根 SC/SC 多模发射电缆—50 ?m、USB 光纤检测视频探头及 4个探尖、SC/SC Simplex 适配器 、(2) 个 LC/LC Simplex 适配器、SC/LC 符合 EF 标准的 MM TRC 工具包 50 ?m、TRC 便携包、TPAK 光纤悬挂工具包、校准说明和入门指南。</td>
</tr>
<tr>
<td><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-cfp-si.html " title="福禄克FLuke OFP-CFP-SI">OFP-CFP-SI</a></span></td>
<td>1 Versiv 主机与远端、(2) 个 CertiFiber Pro Quad OLTS 模块、OptiFiber Quad OTDR 模块、(2) 个手拎带、(2) 个肩带、(2) 个便携包、USB 接口电缆、LinkWare 软件 CD、用户手册 CD、(2) 个交流电充电器、(2) 个一键式清洁器 (1.25/2.50 mm)、2 根 SC/LC 单模发射电缆 —9 ?m、 1 根 SC/SC 单模发射电缆—9 ?m、USB 光纤检测视频探头及 4 个探尖、 SC/SC Simplex 适配器、 (2) 个 LC/LC Simplex 适配器、 SC/LC SM TRC 工具包、TRC 便携包、 TPAK 光纤悬挂工具包、校准说明和入门指南</td>
</tr>
<tr>
<td><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-cfp-qi.html" title="福禄克Fluke OFP-CFP-QI">OFP-CFP-QI</a></span></td>
<td>1 个 Versiv 主机与远端、(2) 个 CertiFiber Pro Quad OLTS 模块、OptiFiber Quad OTDR 模块、(2) 个手拎带、(2) 个肩带、(2) 个便携包、USB 接口电缆、LinkWare 软件 CD、用户手册 CD、(2) 交流电充电器、(2) 一键式清洁器(1.25/2.50 mm)、(2) 根 SC/LC 多模发射电缆 —50 ?m、(2) 根 SC/LC 单模发射电缆—9 ?m、1 根 SC/SC 多模发射电缆—50 ?m、1 根 SC/SC 单模发射电缆—9 ?m、USB 光线检测视频探头及4 个探尖、SC/SC Simplex 适配器、(2) 个 LC/LC Simplex 适配器、SC/LC 符合 EF 标准的 MM TRC 工具包 50 ?m、SC/LC SM TRC 工具包、TRC 便携包、TPAK 光纤悬挂工具包、校准说明和入门指南</td>
</tr>
<tr>
<td>OFP-Q-ADD</td>
<td>OptiFiber Quad OTDR 模块、(2) 根 SC/LC 多模发射电缆—50 ?m、(2) 根 SC/LC 单模发射电缆—9 ?m、1 根 SC/SC 多模发射电缆—50 ?m、1 根 SC/SC 单模发射电缆—9 ?m、SC/SC Simplex 适配器、LC/LC Simplex 适配器、TPAK 光纤悬挂工具、便携包、校准说明和入门指南。</td>
</tr>
<tr>
<td>CFP-Q-ADD</td>
<td>CertiFiber Pro 附加工具包 &#8211; 包括 (2) CertiFiber Pro 四模式 OLTS 模块、符合 SC/LC EF 标准的 MM TRC 便携包 50 ?m、SC/LC SM TRC 便携包、TRC 便携箱、(2) LC/LC Simplex 适配器、大便携箱、用户手册 CD、校准声明和入门指南。</td>
</tr>
<tr>
<td>CFP-Q-ADD-R</td>
<td>1 个 Versiv 远端、(2) 个 CertiFiber Pro Quad OLTS 模块、SC/LC 符合 EF 标准的 MM TRC 工具包 50 ?m、 SC/LC SM TRC 工具包、TRC 便携包、(2) 个 LC/LC Simplex 适配器、(2) 个手拎带、(2) 个肩带、大号便携包、用户手册 CD、交流电充电器、校准说明和入门指南。</td>
</tr>
<tr>
<td>CFP-MM-ADD</td>
<td>(2) 个 CertiFiber Pro Multimode OLTS 模块、SC/LC 符合 EF 标准的 MM TRC 工具包 50 ?m、TRC 便携包、(2) 个 SC/SC 适配器、大号便携包、校准说明和入门指南。</td>
</tr>
<tr>
<td>CFP-SM-ADD</td>
<td>(2) 个 CertiFiber Pro 单模 OLTS 模块、SC/LC SM TRC 工具包、 TRC 便携包、(2) 个 LC/LC 适配器、大号便携包、校准说明和入门指南。</td>
</tr>
</tbody>
</table>
<div>零配件</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>CFP-MM-Mod</td>
<td>CERTIFIBER PRO 多模备用模块</td>
</tr>
<tr>
<td>CFP-SM-Mod</td>
<td>CERTIFIBER PRO 单模备用模块</td>
</tr>
<tr>
<td>CFP-QUAD Mod</td>
<td>CERTIFIBER PRO quad 备用模块</td>
</tr>
<tr>
<td>OFP-FI</td>
<td>带有 SC、FC、ST、LC 闷头和跳接线尖的 DI-1000 Inspector 探头</td>
</tr>
<tr>
<td>VERSIV-M</td>
<td>Versiv 主单元备用部件</td>
</tr>
<tr>
<td>VERSIV-RU</td>
<td>Versiv 远端单元备用部件</td>
</tr>
<tr>
<td>VERSIV-CASE1</td>
<td>Versiv 便携包</td>
</tr>
<tr>
<td>VERSIV-CASE2</td>
<td>Versiv 大便携包</td>
</tr>
<tr>
<td>VERSIV-CASE3</td>
<td>VERSIV 硬质箱</td>
</tr>
<tr>
<td>VERSIV-TSET</td>
<td>Versiv 耳机</td>
</tr>
<tr>
<td>VERSIV-电池</td>
<td>Versiv 电池</td>
</tr>
<tr>
<td>VERSIV-ACUN</td>
<td>Versiv 充电器</td>
</tr>
<tr>
<td>VERSIV-STRP</td>
<td>Versiv 便携带工具包</td>
</tr>
<tr>
<td>VERSIV-STND</td>
<td>Versiv 演示架</td>
</tr>
<tr>
<td>TRC-CASE</td>
<td>用于测试参考线的便携箱</td>
</tr>
<tr>
<td>SRC-9-SCSC-KIT</td>
<td>单模测试参考导线工具包 (2m)，用于测试 SC 终端光纤 (4 SC/SC)</td>
</tr>
<tr>
<td>SRC-9-SCLC-KIT</td>
<td>用于测试 LC 端接光纤（2 SC/LC、2 LC/LC）的单模测试参考线工具包 (2m)</td>
</tr>
<tr>
<td>SRC-9-SCFC-KIT</td>
<td>用于测试 FC 端接光纤（2 SC/FC、2 FC/FC）的单模测试参考线工具包 (2m)</td>
</tr>
<tr>
<td>SRC-9-SCST-KIT</td>
<td>用于测试 ST 端接光纤（2 SC/ST、2 ST/ST）的单模测试参考线工具包 (2m)</td>
</tr>
<tr>
<td>SRC-9-SCSC</td>
<td>用于测试 SC 端接光纤 (SC/SC) 的单模测试参考线 (2m)</td>
</tr>
<tr>
<td>SRC-9-SCLC</td>
<td>用于测试 LC 端接光纤 (SC/LC) 的单模测试参考线 (2m)</td>
</tr>
<tr>
<td>SRC-9-SCFC</td>
<td>用于测试 FC 端接光纤 (SC/FC) 的单模测试参考线 (2m)</td>
</tr>
<tr>
<td>SRC-9-SCST</td>
<td>用于测试 ST 端接光纤 (SC/ST) 的单模测试参考线 (2m)</td>
</tr>
<tr>
<td>SRC-9-LCLC</td>
<td>用于测试 LC 端接光纤 (LC/LC) 的单模测试参考线 (2m)</td>
</tr>
<tr>
<td>SRC-9-FCFC</td>
<td>用于测试 FC 端接光纤 (FC/FC) 的单模测试参考线 (2m)</td>
</tr>
<tr>
<td>SRC-9-STST</td>
<td>用于测试 ST 端接光纤 (ST/ST) 的单模测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-50EFC-SCLCKIT</td>
<td>用于测试 50um SC 端接光纤（2 SC/LC、2 SC/SC）的符合多模环形通量的测试参考线工具包 (2m)</td>
</tr>
<tr>
<td>MRC-50EFC-SCSSCKIT</td>
<td>用于测试 50um SC 端接光纤（4 SC/SC）的符合多模环形通量的测试参考线工具包 (2m)</td>
</tr>
<tr>
<td>MRC-50-EFC-SCSC</td>
<td>用于测试 50um SC 端接光纤 (SC/SC) 的符合多模环形通量的测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-50-EFC-SCLC</td>
<td>用于测试 50um SC 端接光纤 (SC/LC) 的符合多模环形通量的测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-50-EFC-SCFC</td>
<td>用于测试 50um SC 端接光纤 (SC/FC) 的符合多模环形通量的测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-50-EFC-SCST</td>
<td>用于测试 50um SC 端接光纤 (SC/ST) 的符合多模环形通量的测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-625EFC-SCLCKIT</td>
<td>用于测试 62.5um SC 端接光纤（2 SC/LC、2 SC/SC）的符合多模环形通量的测试参考线工具包 (2m)</td>
</tr>
<tr>
<td>MRC-625EFC-SCSSCKIT</td>
<td>用于测试 62.5um SC 端接光纤（4 SC/SC）的符合多模环形通量的测试参考线工具包 (2m)</td>
</tr>
<tr>
<td>MRC-625-EFC-SCSC</td>
<td>用于测试 62.5um SC 端接光纤 (SC/SC) 的符合多模环形通量的测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-625-EFC-SCLC</td>
<td>用于测试 62.5um SC 端接光纤 (SC/LC) 的符合多模环形通量的测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-625-EFC-SCFC</td>
<td>用于测试 62.5um SC 端接光纤 (SC/FC) 的符合多模环形通量的测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-625-EFC-SCST</td>
<td>用于测试 62.5um SC 端接光纤 (SC/ST) 的符合多模环形通量的测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-50-SCSC</td>
<td>用于测试 50um SC 端接光纤 (SC/SC) 的多模测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-50-LCLC</td>
<td>用于测试 50um SC 端接光纤 (LC/LC) 的多模测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-50-FCFC</td>
<td>用于测试 50um SC 端接光纤 (FC/FC) 的多模测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-50-STST</td>
<td>用于测试 50um SC 端接光纤 (ST/ST) 的多模测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-625-SCSC</td>
<td>用于测试 62.5um SC 端接光纤 (SC/SC) 的多模测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-625-LCLC</td>
<td>用于测试 62.5um SC 端接光纤 (LC/LC) 的多模测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-625-FCFC</td>
<td>用于测试 62.5um SC 端接光纤 (FC/FC) 的多模测试参考线 (2m)</td>
</tr>
<tr>
<td>MRC-625-STST</td>
<td>用于测试 62.5um SC 端接光纤 (ST/ST) 的多模测试参考线 (2m)</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/certifiber-pro.html/feed</wfw:commentRss>
		<slash:comments>9</slash:comments>
		</item>