<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; 光纤接头</title>
	<atom:link href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e6%8e%a5%e5%a4%b4/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>福禄克测试过程中光纤接头的主要故障</title>
		<link>http://www.faxytech.com/archives/jt-fault.html</link>
		<comments>http://www.faxytech.com/archives/jt-fault.html#comments</comments>
		<pubDate>Mon, 18 Jul 2016 11:01:14 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[光纤损耗]]></category>
		<category><![CDATA[光纤接头]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7838</guid>
		<description><![CDATA[我们在用福禄克DTX-1800或者DSX-5000测试光纤过程中，经常会面临测试不通过的情况，很多客户可能经常找不出原因，今天连讯达工程师为大家分析光纤接头的几种故障现象。再优秀和快速的非打... ]]></description>
			<content:encoded><![CDATA[<p>我们在用福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>或者<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>测试光纤过程中，经常会面临测试不通过的情况，很多客户可能经常找不出原因，今天连讯达工程师为大家分析<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e6%8e%a5%e5%a4%b4" title="查看 光纤接头 的全部文章" target="_blank">光纤接头</a></span>的几种故障现象。再优秀和快速的非打磨光纤头端接工艺，仍然会因为操作不当或材料受损问题造成接续不良。可能导致出现接续故障的因素大致包括：a.污染、b.光纤碎裂、c.光纤的不良切割或折断、d.预置打磨光纤与切割光纤接续缝隙过大、e.过偏的光纤切割角度。</p>
<p>故障定位：a.污染（图七a）</p>
<p>光纤连接头出现污染可能的原因有：</p>
<p>? 使用了受到污染的切割工具（通过无水酒精擦拭工具表面）</p>
<p>? 切割完成后再次擦拭了光纤（绝对不要在切割后擦拭光纤）</p>
<p>? 将连接头或光纤置于带灰尘的表面</p>
<p>? 处于满是灰尘的环境</p>
<p>? 插入已折断的光纤，用力过度</p>
<p>需要注意的是如果污染一旦被带入到光纤接头内部，特别是和接合凝胶接触后，将很难再被清除出来，这也意味着光纤连接头的报废。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-a.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7839" title="fluke-a" src="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-a.jpg" alt="" width="500" height="150" /></a></p>
<p>&nbsp;</p>
<p>故障定位：</p>
<p>b.光纤碎裂（图七b）</p>
<p>可能导致光纤碎裂的原因有：</p>
<p>?插入用力过度产生的光纤碎片污染</p>
<p>?插入已折断的光纤引起碎裂</p>
<p>嵌入的光纤碎片将引起光纤缝隙和光学故障，并且嵌入的光纤碎片是很难被清除出来的，这种情况下光纤接头将报废。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-b.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7840" title="fluke-b" src="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-b.jpg" alt="" width="500" height="146" /></a></p>
<p>&nbsp;</p>
<p>故障定位：c. 光纤的不良切割或折断（图七c）</p>
<p>造成光纤切割不良或折断的原因有：</p>
<p>?钝的或有裂口的切割刀锋 – 不能正常切割光纤</p>
<p>?切割工具上弯曲的标尺舌在光纤上施加了过度集中的弯力</p>
<p>?光纤弯折过多或者弯曲半径过紧</p>
<p>?在切割中没有用力或者用力不足</p>
<p>当没有碎片产生或没有受到污染的情况下，这种故障允许光纤连接头被重新切割接续一次。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-c.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7841" title="fluke-c" src="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-c.jpg" alt="" width="500" height="116" /></a></p>
<p>&nbsp;</p>
<p>故障定位：d. 预置打磨光纤与切割光纤接续缝隙过大（图七d）</p>
<p>造成接续缝隙过大的原因有：</p>
<p>? 光纤切割长度太短</p>
<p>? 光纤未完全导入, 或在端接时被回拉</p>
<p>? 在室外光缆接合时，光纤被推回到了护套管中</p>
<p>过大的光纤缝隙只允许被纠正一次。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-d.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7842" title="fluke-d" src="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-d.jpg" alt="" width="500" height="120" /></a></p>
<p>&nbsp;</p>
<p>故障定位：e. 过偏的光纤切割角度（图七e）</p>
<p>在接续现场，切割角度过偏很难被觉察。引发切割角度过偏的因素有：</p>
<p>? 切割工具上的弯曲舌在光纤上施加过分集中的弯曲力</p>
<p>? 光纤弯折过大或者弯曲半径过紧</p>
<p>? 在切割中没有用力或者用力不足</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-3.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7843" title="fluke-3" src="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-3.jpg" alt="" width="500" height="141" /></a></p>
<p>一般光纤切割后，典型的切割角度为1-3度，即便使用更精密的切割刀，光纤切割后仍然有0.5-1度的偏角。出现偏角的情况可以通过使用可见红光源（VFL）输入，并且缓慢旋转被切割的光纤端面，在PROclick连接头的可视窗口内监视直到红光消失的方法来解决。如图七f。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-f.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7844" title="fluke-f" src="http://www.faxytech.com/wp-content/uploads/2016/07/fluke-f.jpg" alt="" width="500" height="268" /></a></p>
<p>&nbsp;</p>
<p>通过上面的介绍，不难看出非打磨光纤现场接续对于接续工艺和操作技术的敏感，非打磨现场端接技术的关键还是在于安装人员必须保持统一的切割和端接工艺，并且为使安装过程受控和避免返工，在接续中总是通过检测（如可视光源检测）以建立在端接过程中的信心，降低接续失败的风险。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/jt-fault.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克OptiFiber PRO如何测试不同接头光纤跳线？</title>
		<link>http://www.faxytech.com/archives/optifiber-adapter.html</link>
		<comments>http://www.faxytech.com/archives/optifiber-adapter.html#comments</comments>
		<pubDate>Mon, 10 Aug 2015 07:49:50 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[OptiFiber Pro]]></category>
		<category><![CDATA[OTDR]]></category>
		<category><![CDATA[光纤接头]]></category>
		<category><![CDATA[光纤跳线]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6601</guid>
		<description><![CDATA[福禄克OptiFiber PRO如何测试不同接头光纤跳线？众所周知，福禄克OptiFiber?PRO光纤测试仪中的OFP-100-Q单多模测试仪OTDR，OFP-100-M多模测试仪OTDR，OFP-100-S单模测试仪OTDR标准的福禄克光纤接头是SC头，... ]]></description>
			<content:encoded><![CDATA[<p>福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> PRO如何测试不同接头<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e8%b7%b3%e7%ba%bf" title="查看 光纤跳线 的全部文章" target="_blank">光纤跳线</a></span>？众所周知，福禄克<span style="font-family: 'Times New Roman';">OptiFiber?PRO</span><span style="font-family: 宋体;"><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>中的</span><span style="font-family: 'Times New Roman';"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span></span><span style="font-family: 宋体;">单多模测试仪</span><span style="font-family: 'Times New Roman';"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span></span><span style="font-family: 宋体;">，</span><span style="font-family: 'Times New Roman';"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-m.html" title="fluke OFP-100-M">OFP-100-M</a></span></span><span style="font-family: 宋体;">多模测试仪</span><span style="font-family: 'Times New Roman';"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/otdr" title="查看 OTDR 的全部文章" target="_blank">OTDR</a></span></span><span style="font-family: 宋体;">，</span><span style="font-family: 'Times New Roman';"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-s.html" title="福禄克Fluke OFP-100-S">OFP-100-S</a></span></span><span style="font-family: 宋体;">单模测试仪</span><span style="font-family: 'Times New Roman';">OTDR</span><span style="font-family: 宋体;">标准的福禄克<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e6%8e%a5%e5%a4%b4" title="查看 光纤接头 的全部文章" target="_blank">光纤接头</a></span>是</span><span style="font-family: 'Times New Roman';">SC</span><span style="font-family: 宋体;">头，那么我们如果要测试其他光纤类型，如何找到合适的解决方案呢？</span></p>
<p>方法有二，一种是通过配置光纤转换器，一种是通过光纤跳线转换。</p>
<p>&nbsp;</p>
<h4><strong>方法一：光纤接头型号有：</strong></h4>
<table>
<tbody>
<tr>
<td width="108" valign="center">PA-SC</td>
<td width="455" valign="center">OTDR?源端口可互换?SC?适配器</td>
</tr>
<tr>
<td width="108" valign="center">PA-LC</td>
<td width="455" valign="center">OTDR?源端口可互换?LC?适器</td>
</tr>
<tr>
<td width="108" valign="center">PA-ST</td>
<td width="455" valign="center">OTDR?源端口可互换?ST?适配器</td>
</tr>
<tr>
<td width="108" valign="center">PA-FC</td>
<td width="455" valign="center">OTDR?源端口可互换?FC?适配器</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4>方法二：光纤跳线：</h4>
<p>50多模：MMC-50-SCLC????????MMC-50-SCST ? ? ? MMC-50-SCFC???????MMC-50-SCSC</p>
<p>62.5多模：MMC-62-SCSLC????????MMC-62-SCST ? ? ? MMC-62-SCFC???????MMC-62-SCSC</p>
<p>9单模：??SMC-9-SCLC??????????SMC-9-SCST???????????SMC-9-SCFC?????????SMC-9-SCSC</p>
<p>参考图片：</p>
<p><img class="alignnone" title="福禄克光纤跳线图片" src="http://www.faxy-tech.com/UploadFiles/Product/2015-01-09/20150109125007522.jpg" alt="福禄克光纤跳线图片" width="540" height="449" /></p>
<p><img src="file:///d:/users/administrator/appdata/roaming/360se6/User Data/temp/20150109130818190.jpg" alt="" /></p>
<p><img src="file:///d:/users/administrator/appdata/roaming/360se6/User Data/temp/20150109130818190.jpg" alt="" /></p>
<p><img src="file:///d:/users/administrator/appdata/roaming/360se6/User Data/temp/20150109125007522.jpg" alt="" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/optifiber-adapter.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DTX1800不同接头测试方案【案例图解】</title>
		<link>http://www.faxytech.com/archives/dtx1800-nfa.html</link>
		<comments>http://www.faxytech.com/archives/dtx1800-nfa.html#comments</comments>
		<pubDate>Tue, 02 Sep 2014 02:24:56 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DTX-EFM2]]></category>
		<category><![CDATA[dtx1800]]></category>
		<category><![CDATA[光纤接头]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=4659</guid>
		<description><![CDATA[福禄克网络公司于2004年推出Fluke ?DTX-1800 Calbe Analzyer认证分析仪，一直受到全球瞩目和信赖，凭借其优越的性能优势，在中国市场占有率超过90%，今天深圳市连讯达电子技术开发有限公司工程师... ]]></description>
			<content:encoded><![CDATA[<p>福禄克网络公司于2004年推出Fluke ?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span> Calbe Analzyer认证分析仪，一直受到全球瞩目和信赖，凭借其优越的性能优势，在中国市场占有率超过90%，今天深圳市连讯达电子技术开发有限公司工程师为大家介绍<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克DTX 1800">DTX1800</a></span>光纤模块<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-xfm2.html" title="DTX系列分析仪仪光纤测试模块">DTX-MFM2</a></span>和<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-xfm2.html" title="DTX系列光缆测试模块">DTX-SFM2</a></span>以及新产品<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-EFM2的不同光纤的测试解决方案。</p>
<p>福禄克光缆模块的优点有：</p>
<ol>
<li>随时可用的背插式光缆模块</li>
<li> 12 秒钟的自动测试比现有仪器快5 倍</li>
<li>通过<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span> 软件提供一级光缆认证测试报告</li>
<li> 内置的可视故障定位器（VFL）可查找光缆，验证连通性和极性，并能发现断点</li>
<li>通过对讲机、查找光缆、监测、双向测试和单光缆测试等功能提高测试速度</li>
<li>可作为福禄克网络公司的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> 光缆认证（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>）分析仪的智能远端</li>
</ol>
<p>众所周知，福禄克DTX1800标配<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e6%8e%a5%e5%a4%b4" title="查看 光纤接头 的全部文章" target="_blank">光纤接头</a></span>是SC。那如何才能对不同接头进行测试呢？例如：我需要测试LC接头的万兆光纤。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/DTX-1800-SC.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-4662" title="DTX-1800光纤模块SC接头" src="http://www.faxytech.com/wp-content/uploads/2014/09/DTX-1800-SC.jpg" alt="DTX-1800光纤模块SC接头" width="500" height="375" /></a></p>
<p>福禄克DTX1800 的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dtx-efm2" title="查看 DTX-EFM2 的全部文章" target="_blank">DTX-EFM2</a></span>标配连接头为SC接头。</p>
<p>如果我们需要测试LC的光纤。购买福禄克万兆光纤跳线型号为：NFK2-DPLX-LC 50um</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/dtx1800-lc2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-4664" title="福禄克dtx1800 LC连接头" src="http://www.faxytech.com/wp-content/uploads/2014/09/dtx1800-lc2.jpg" alt="福禄克dtx1800 LC连接头" width="502" height="374" /></a></p>
<p>细心的朋友应该发现，NFK2-DPLX-LC的原装光纤跳线的接头类型是：2对跳线。一对中一条是：SC-LC，另一条是LC-LC。这意味着什么呢？我们DTX-EFM2的标准连接头SC头已经不能完全适用了。必须把DTX1800光纤模块上的一个连接头换成LC头，换句话说：DTX-EFM2的模块必须有一个是SC连接器一个是LC连接器。而标准配置是2个SC连接器。OUTPUT输出端口是固定SC头，不能更换，那就只能更换INPUT端口换成LC接头。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/LC-adpter.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-4665" title="LC-adpter" src="http://www.faxytech.com/wp-content/uploads/2014/09/LC-adpter.jpg" alt="" width="500" height="375" /></a></p>
<p>上图为福禄克DTX系列光纤模块的LC转换适配器</p>
<p>在福禄克DTX-1800主机的光纤模块上更换LC适配器，就形成以下连接模型，我们就可以测试我现场工程要测试的LC连接接头的光纤了。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/09/dtx1800-lc.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-4663" title="dtx1800测试仪LC连接跳线" src="http://www.faxytech.com/wp-content/uploads/2014/09/dtx1800-lc.jpg" alt="dtx1800测试仪LC连接跳线" width="500" height="375" /></a></p>
<p>方案总结：如果我们需要测试不同光纤类型，购买了福禄克原装跳线的同时，不要忘记购买转换适配器。具体请联系连讯达公司。0755-83999818</p>