<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; MultiFiber Pro</title>
	<atom:link href="http://www.faxytech.com/tag/multifiber-pro/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>福禄克光纤测试仪的区别？如何正确选择一级二级测试的设备？</title>
		<link>http://www.faxytech.com/archives/choose-fluke.html</link>
		<comments>http://www.faxytech.com/archives/choose-fluke.html#comments</comments>
		<pubDate>Wed, 28 Oct 2020 01:59:17 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[Fiber QuickMap]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[MultiFiber Pro]]></category>
		<category><![CDATA[VisiFault]]></category>
		<category><![CDATA[福禄克网络]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11776</guid>
		<description><![CDATA[今天和大家一起更深入地走进福禄克网络的产品，帮助大家能够更快地找到适合自己工作需求的“得力助手” 。 &#160; 首先为大家介绍一下福禄克网络都有哪些测试光纤的产品，我们根据不同... ]]></description>
			<content:encoded><![CDATA[<p>今天和大家一起更深入地走进<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b%e7%bd%91%e7%bb%9c" title="查看 福禄克网络 的全部文章" target="_blank">福禄克网络</a></span>的产品，帮助大家能够更快地找到适合自己工作需求的“得力助手” 。</p>
<p>&nbsp;</p>
<p>首先为大家介绍一下福禄克网络都有哪些测试光纤的产品，我们根据不同的使用场景和不同类型主要分为三大类：</p>
<p>第一类是认证级仪表，它是根据标准对光纤链路进行认证，并给出测试报告是否合规，这类仪表均属于同一平台，其模块化设计，可根据需求更换模块，进行不同的测试内容。其中包括T1一级测试（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> PRO）、T2二级测试(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> PRO)，事实上，这里也应该包括认证级光纤端面检测（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fiberinspector-mini.html" title="FiberInspector 袖珍光纤视频显微镜">FiberInspector</a></span>）产品FI-7000 &amp;<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fi-3000-mpo.html" title="福禄克FLUKE FI-3000">FI-3000</a></span>，但是为了让分类更清晰化，我们将光纤端面检测类的产品归在了一起做介绍。</p>
<p>第二类是我们刚才提到的光纤端面检测设备，其中有两款属于认证级，一个是FI-7000另一个是FI-3000，FI-3000是针对<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span>光纤端面进行检测的，我们单独把光纤端面检测类的产品设为一类，还有一个更为重要的原因，是因为光纤很大一部分故障都是由于光纤端面脏污引起的，这也是为什么标准中加入了光纤端面检测部分；</p>
<p>第三类属于维护和故障诊断类仪表，包括断点定位设备（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-quickmap.html" title="福禄克Fluke Fiber QuickMap">Fiber QuickMap</a></span>）；光纤损耗测试工具（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/simplifiber-pro.html" title="福禄克FLUKE SimpliFiber Pro光纤测试仪">SimpliFiber</a></span> PRO）；MPO<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="MultiFiber Pro">MultiFiber Pro</a></span>）；还有可视故障定位仪（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/visifault.html" title="福禄克FLUKE VISIFAULT红光笔">VisiFault</a></span>），也就是我们常说的红光笔，这类产品主要是满足对光纤链路日常维护所使用的。</p>
<p>接下来介绍一下不同场景下经常使用哪些产品。使用场景我们分为两大类，第一类是新建或升级的机房（数据中心），大家都知道数据链路的可靠、稳定传输是保障网络运行的基础，尤其是在网络飞速发展的今天，还要为我们的网络留有一定的冗余空间来应对速率的不断提升，那么我们如何做到这点呢？又如何检测其质量呢？</p>
<p>&nbsp;</p>
<p>在新建或升级机房（数据中心）的时候做好数据链路的认证、合规测试是非常重要的。在这里我们需要涉及到的设备有认证级仪表、认证级光纤端面检测仪表和必要的光纤清洁工具，也就是我们前面提到的CFP、OFP、FI-7000（FI-3000）这几类产品。适用对象为布线系统专业人员，在进行工程验收测试上置信度是最为严格的，所有的测试都是依据标准进行的；另一类是日常维护，故障检测。主要涉及到的产品除了我们之前提到的维护类工具外，还包括<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>（OFP），提供合规、更为智能、简单、可视化的故障定位分析仪，当然还要包括必不可少的光纤端面检测设备和清洁工具。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/choose-fluke.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>利用MultiFiber Pro解决8芯MPO测试难题</title>
		<link>http://www.faxytech.com/archives/8mpo.html</link>
		<comments>http://www.faxytech.com/archives/8mpo.html#comments</comments>
		<pubDate>Mon, 07 Nov 2016 00:59:32 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[8芯MPO]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[MultiFiber Pro]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8221</guid>
		<description><![CDATA[从10 Gb以太网开始，多年以来，数据中心的多模光纤骨干网广泛使用即插即用12芯MPO解决方案，其中12芯MPO组件连接MPO转LC终端盒或模块，将12芯MPO连接转换为6组双工LC连接。 使用预端接即插即用... ]]></description>
			<content:encoded><![CDATA[<p>从10 Gb以太网开始，多年以来，数据中心的多模光纤骨干网广泛使用即插即用12芯<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span>解决方案，其中12芯MPO组件连接MPO转LC终端盒或模块，将12芯MPO连接转换为6组双工LC连接。</p>
<p>使用预端接即插即用MPO方案具有诸多好处，包括安装快速、减少路径填充，以及工厂端接的性能。其广泛应用还有另外一个原因，就是很容易移植到要求MPO连接器的、更高速率的40 Gb和100 Gb，只需拆下MPO转LC终端盒并换上MPO直通适配器即可。</p>
<p>有多家电缆和连接件厂商现在提供适用于40 Gb和100 Gb应用的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/8%e8%8a%afmpo" title="查看 8芯MPO 的全部文章" target="_blank">8芯MPO</a></span>解决方案。我们接下来深入了解一下。</p>
<p>&nbsp;</p>
<p><strong>避免浪费</strong></p>
<p>除了预端接电缆的好处外，如果用于40 Gb和100 Gb应用，12芯MPO方案浪费33%的光纤。因为40GBASE-SR4和100GBASE-SR4应用仅使用12芯中的8芯——4芯发送和4芯接收，速率为10或25 Gb/s。另外4芯不使用。</p>
<p><img src="http://www.faxy-tech.com/UploadFiles/Others/MultiFiber-Pro-7.jpg" alt="" /></p>
<p><img src="data:image/png;base64,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" alt="" /></p>
<p>当40 Gb和100 Gb部署成为现实时，使用MPO接口的有源设备投入市场，有些连接件厂商通过使用带终端盒的24芯MPO组件，转换为8芯MPO，从而解决光纤浪费问题。其他厂商提供混合跳线，将单个24芯MPO分为三组8芯MPO。</p>
<p>但是这些方案本身存在问题。将24芯MPO转换为8芯MPO的终端盒为每个通道引入了附加损耗。混合跳线难以管理，意味着如果某一个8芯MPO连接损坏，为了更换混合跳线，就必须断开全部三个端口。</p>
<p>&nbsp;</p>
<p><strong>神奇的数字8</strong></p>
<p>为简化40 Gb和100 Gb部署，并使其更加可靠、提高性价比以及避免浪费，电缆和连接件厂商现在提供带有8芯trunk组件和8芯MPO连接的8芯MPO方案。</p>
<p>关于这类方案，值得注意的是其不改变密度——8芯MPO和12芯MPO所占的面积相同。利用8芯MPO转4组双工LC的终端盒，仍然可用于10 Gb应用。</p>
<p>那关于测试呢？也完全相同，没错。由于40 Gb和100 Gb应用仅使用12芯MPO中的8芯，所以两种连接器的外形一样，没有什么不同。</p>
<p>所以，放心用您的<a>Fluke Networks MultiFiber Pro</a>进行测试，与测试12芯MPO通道完全相同。无论是8根还是12根光纤，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="MultiFiber Pro">MultiFiber Pro</a></span>都是同时扫描所有光纤，用清晰明了的图形显示测试结果。甚至能够测试极性是否正确，以及检测MPO系统中的单根光纤故障。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/8mpo.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>如何利用福禄克MultiFiber Pro测试MPO (MFTK1200,MFTK-SM1310)</title>
		<link>http://www.faxytech.com/archives/multifiber-mpo.html</link>
		<comments>http://www.faxytech.com/archives/multifiber-mpo.html#comments</comments>
		<pubDate>Fri, 02 Sep 2016 02:27:03 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[MFTK-SM1310]]></category>
		<category><![CDATA[MFTK1200]]></category>
		<category><![CDATA[MPO]]></category>
		<category><![CDATA[MultiFiber Pro]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8006</guid>
		<description><![CDATA[现在在数据中心，MPO光纤已经开始变成一种趋势了。那么如何进行有效的MPO测试呢？在MPO测试中通常接线有三种类型：分为A接法，B接法，C接法。 MPO测试中的A方法 MPO测试中的B方法 &#160; 那么... ]]></description>
			<content:encoded><![CDATA[<p>现在在数据中心，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span>光纤已经开始变成一种趋势了。那么如何进行有效的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/mpo" title="查看 MPO 的全部文章" target="_blank">MPO</a></span>测试呢？在MPO测试中通常接线有三种类型：分为A接法，B接法，C接法。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/MPO.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8007" title="MPO测试的A方法" src="http://www.faxytech.com/wp-content/uploads/2016/09/MPO.jpg" alt="MPO测试的A方法" width="640" height="203" /></a></p>
<p>MPO测试中的A方法</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/MPO-B.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8008" title="MPO测试中的B方法" src="http://www.faxytech.com/wp-content/uploads/2016/09/MPO-B.jpg" alt="MPO测试中的B方法" width="640" height="189" /></a></p>
<p>MPO测试中的B方法</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/MPO-C.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8009" title="MPO测试的C方法" src="http://www.faxytech.com/wp-content/uploads/2016/09/MPO-C.jpg" alt="MPO测试的C方法" width="640" height="199" /></a></p>
<p>&nbsp;</p>
<p>那么，有没有一种简单快速的办法，能够高效的完成 MPO 光纤测试呢？那就要请出我们今天的主角——MPO 测试的喀秋莎——<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="MultiFiber Pro">MultiFiber Pro</a></span>：</p>
<p><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/multifiber-pro" title="查看 MultiFiber Pro 的全部文章" target="_blank">MultiFiber Pro</a></span> 可以用来快速认证包含8根、10根或者12根多模光纤的 MPO 链路，并且可以自动识别并报告极性类别。本文将为您介绍在 MPO 光纤两端使用 MultiFiber Pro 认证 MPO 光纤的方法。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/MPO1.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8010" title="MPO" src="http://www.faxytech.com/wp-content/uploads/2016/09/MPO1.jpg" alt="" width="522" height="116" /></a></p>
<p>在涉及测试跳线时，MultiFiber Pro有个很大的好处是不挑跳线，您可以使用B型跳线来测试A型链路，反之也可，这同样也适用于C型链路。此外，如果您只用12根光纤中的8根来支持 40GBASE-SR4，或者只用10根来支持 100GBASE-SR10，MultiFiber Pro 将会自动将其识别为有效的链路，即使未使用的光纤不存在，也不会认为链路是有故障的，如下图所示：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/40GMPO.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8011" title="40GMPO" src="http://www.faxytech.com/wp-content/uploads/2016/09/40GMPO.jpg" alt="" width="616" height="350" /></a></p>
<p><strong>您将会用到以下设备：</strong></p>
<p>- <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MFTK1200">MFTK1200</a></span></p>
<p>- 公对公 MPO 1米测试跳线 （2根）（注意：使用母头测试跳线插入光源或光功率计将会导致不稳定的读数）</p>
<p>- MPO 背靠背适配器</p>
<p>&nbsp;</p>
<p>此外，仔细的光纤端面检查在这项工作中是极其重要的，没有检查这个环节，您将会得到较差或不可预测的测试结果。USB FI-1000 光纤端面检查仪 (下图所示) 自带了检查 MPO 适配器的配件，您可以通过插入到 <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> 平台来使用。</p>
<p>&nbsp;</p>
<h4><strong>测试极限值</strong></h4>
<p>您需要计算所测链路的预期损耗值，并将此输入到 MultiFiber Pro。我们无法告诉您什么是合适的测试极限值，您必须咨询布线系统的设计者，有关于测试极限值应用的信息可以在<a title="Click here to download the test limits document" target="_blank">Versiv 测试极限值文档中</a>查到。</p>
<h4><strong>输入测试极限值</strong></h4>
<p>1、按F3键来选择所需的波长。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/0.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8012" title=" MultiFiber Pro" src="http://www.faxytech.com/wp-content/uploads/2016/09/0.gif" alt=" MultiFiber Pro" width="200" height="251" /></a></p>
<p>2、长按MENU/SELECT（菜单/选择）大约3秒，等待显示。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/menu.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8013" title="menu-MultiFiber Pro" src="http://www.faxytech.com/wp-content/uploads/2016/09/menu.jpg" alt="menu-MultiFiber Pro" width="206" height="267" /></a></p>
<p>3、按F1键来移动光标至LOSS LIMIT（损耗极限）。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/LOSS-mulitFIber.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8014" title="LOSS-mulitFIber" src="http://www.faxytech.com/wp-content/uploads/2016/09/LOSS-mulitFIber.png" alt="" width="200" height="251" /></a></p>
<p>4、按MENU/SELECT（菜单/选择）键进行选择。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/select-multifiber.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8015" title="select-multifiber" src="http://www.faxytech.com/wp-content/uploads/2016/09/select-multifiber.jpg" alt="" width="210" height="261" /></a></p>
<p>5、使用F1和F2键来改变dB值，与您的要求匹配。</p>
<p>6、完成后点击MENU/SELECT（菜单/选择）保存。</p>
<p>7、再次长按MENU/SELECT（菜单/选择）大约三秒，退出设置菜单。</p>
<p>&nbsp;</p>
<h4><strong>进行测量</strong></h4>
<p>1、打开光源和光功率计，并且让它们稳定运行至少5分钟，如果仪器一直在同一<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>的测试区域内存放，那么五分钟的时长已经足够。如果仪器存放的区域和使用测试的区域有着明显的温差，那么您就需要让仪器稳定运行更长的时间。我们将会在第六步对光源的稳定性进行检查。</p>
<p>2、使用第一根公对公 MPO 测试跳线，将光源和光功率计连接在一起。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/pinned-multifiber.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8016" title="pinned-multifiber" src="http://www.faxytech.com/wp-content/uploads/2016/09/pinned-multifiber.gif" alt="" width="334" height="324" /></a></p>
<p>&nbsp;</p>
<p>3、正常的情况下，您可以在光功率计屏幕上看到所有12个通道都有5根表示强度的横线，最多不应该少于4根。如果在某一个通道上只有3根或者更少，说明这根测试跳线已经不能用，应该换根新的。同时 MultiFiber Pro 的测试端口也需要清洁。如果您坚持使用不良的测试跳线，那么测试结果将无法确保准确。</p>
<p>4、点击 MENU/SELECT（菜单/选择）键，您将会在屏幕上看到 SET REF（设置参考值）。（参考值设置将会自动开始）</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/set-multifiber-pro.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8017" title="set-multifiber-pro" src="http://www.faxytech.com/wp-content/uploads/2016/09/set-multifiber-pro.gif" alt="" width="200" height="293" /></a></p>
<p>5、完成后，SAVE（保存）将会出现在F1键的上方，按下F1键，屏幕上将会显示0.00 dB。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/pinned-multifiber-2.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8018" title="pinned-multifiber-2" src="http://www.faxytech.com/wp-content/uploads/2016/09/pinned-multifiber-2.gif" alt="" width="334" height="324" /></a></p>
<p>6、保持测试跳线不断开，观测光源的稳定性大约30秒，如果您看到损耗值有所改变，重复第四步，直到您得到一个稳定的读数。</p>
<p>7、从光功率计一端断开连接：（不要从光源断开连接）</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-7.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8019" title="multifiber-7" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-7.gif" alt="" width="576" height="209" /></a></p>
<p>8、使用极性对调工具，将#1测试跳线由公头改为母头：（不要换测试跳线）</p>
<p><img src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-7.gif" alt="" width="576" height="209" /></p>
<p>9、在光功率计上，插入第二根公对公 MPO测试跳线：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-9.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8020" title="multifiber-9" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-9.gif" alt="" width="576" height="209" /></a></p>
<p>10、连接光源和光功率计，确保所有通道的损耗值不超过0.35dB：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-11.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8021" title="multifiber-11" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-11.gif" alt="" width="467" height="334" /></a></p>
<p>11、断开光源和光功率计的连接：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-11-2.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8022" title="multifiber-11-2" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-11-2.gif" alt="" width="576" height="209" /></a></p>
<p>12、使用极性对调工具，将#2测试跳线由公头改为母头：（不要换测试跳线）</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-12.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8023" title="multifiber-12" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-12.gif" alt="" width="576" height="209" /></a></p>
<p>13、连接想要认证的链路。在6秒后，所有的12根光纤的光损耗都会被测量。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-131.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8025" title="multifiber-13" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-131.gif" alt="" width="576" height="222" /></a></p>
<p>14、点击F1来保存您的结果。（所有的12根光纤的结果将会被同时保存）</p>
<p>&nbsp;</p>
<p><strong>特别提示</strong></p>
<p>- 当您浏览LOSS(损耗)时，每个横线代表着您输入的测试极限值的25%。</p>
<p>- 损耗值的读数小于-0.09将会导致测试失败，如果此情况发生，便说明您的光源不稳定，请重新设置参考。</p>
<p>- MPO测试跳线应该经常的检查和更换，供应商建议多模 MPO/MTPs的测试跳线的标准寿命在500至1000次的拔插之间。</p>
<p>- MultiFiber Pro将会保存3000根光纤的损耗结果。</p>
<p>- 测试结果可以通过USB线传输到<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span> PC端。</p>
<p>&nbsp;</p>