<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; fluke维修</title>
	<atom:link href="http://www.faxytech.com/tag/fluke%e7%bb%b4%e4%bf%ae/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>福禄克DTX-1800常见故障</title>
		<link>http://www.faxytech.com/archives/dtx1800-fault.html</link>
		<comments>http://www.faxytech.com/archives/dtx1800-fault.html#comments</comments>
		<pubDate>Fri, 03 Jun 2016 01:29:19 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[fluke维修]]></category>
		<category><![CDATA[常见故障]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7685</guid>
		<description><![CDATA[深圳连讯达20年来，专注于福禄克测试仪的销售与技术支持服务。现在DTX-1800系列仪器已经上市已经有10多年历史了，所以难免会有些仪器出现故障的现象。经过分析，基本DTX-1800常见故障现象如... ]]></description>
			<content:encoded><![CDATA[<p>深圳连讯达20年来，专注于福禄克测试仪的销售与技术支持服务。现在<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>系列仪器已经上市已经有10多年历史了，所以难免会有些仪器出现故障的现象。经过分析，基本<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-1800<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%b8%b8%e8%a7%81%e6%95%85%e9%9a%9c" title="查看 常见故障 的全部文章" target="_blank">常见故障</a></span>现象如下：</p>
<p><strong>a，</strong>设备无法开机；</p>
<p><strong>b，</strong>设备反复重启；</p>
<p><strong>c，</strong><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>无法通过；</p>
<p><strong>d，</strong><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>、RL测试指标误差较大；</p>
<p><strong>e，</strong>指示灯常亮、无法关机；</p>
<p><strong>f，</strong>系统报错，找不到远端，反复来回测试</p>
<p><strong>g，</strong>其他不明故障。。。。</p>
<p>通过梳理这些<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克DTX 1800">DTX1800</a></span>维修案例典型性错误，我们发现很多是基于用户长时间的使用，没有对设备进行基本的维护保养，导致长年累月的小毛病最终酿成大的悲剧，有时候设备的清洁没有搞好，导致显示板灰尘累积的结果下，操控失灵，严重的导致短路，烧掉不必要的元器件。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dtx1800-fault.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修</title>
		<link>http://www.faxytech.com/archives/f15b-f17b-wx2.html</link>
		<comments>http://www.faxytech.com/archives/f15b-f17b-wx2.html#comments</comments>
		<pubDate>Fri, 20 May 2016 10:30:08 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[F17B]]></category>
		<category><![CDATA[fluke 15b]]></category>
		<category><![CDATA[fluke维修]]></category>
		<category><![CDATA[故障维修]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7604</guid>
		<description><![CDATA[首先要检查表笔与VΩ插孔和COM插孔是否接触不良，如果接触正常，第二步检查VΩ插接孔接的保护原件PTC，RV三只压敏是否损坏，一般来说这些保护元件坏的机率很小，我只能说是一般情况下。 ... ]]></description>
			<content:encoded><![CDATA[<p>首先要检查表笔与VΩ插孔和COM插孔是否接触不良，如果接触正常，第二步检查VΩ插接孔接的保护原件PTC，RV三只压敏是否损坏，一般来说这些保护元件坏的机率很小，我只能说是一般情况下。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/05/fluke-15b-wx1.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7605" title="直流电压挡无法测量故障维修" src="http://www.faxytech.com/wp-content/uploads/2016/05/fluke-15b-wx1.png" alt="" width="647" height="213" /></a></p>
<p>如果上面的保护元件没有损坏，则第三步要检查开关S1是否出现接触不良或V字片接触不良导致电源档无法使用，如果正常的话，第四步检查FS9721外接的分压电阻有无虚焊，开路，或烧坏，如果分压电阻没有烧坏，开路的，首先要补焊一边分压电阻，防止分压电阻虚焊或氧化，因为是贴片电阻，容易虚焊，如果补焊完，直流电压档还是无法使用，那么直接更换FS9721_LP3来修复。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/05/fluke-15b-wx2.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7606" title="直流电压挡无法测量故障维修" src="http://www.faxytech.com/wp-content/uploads/2016/05/fluke-15b-wx2.png" alt="" width="613" height="368" /></a></p>
<p>直流mv裆显示<strong>OL</strong>不能测量<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%95%85%e9%9a%9c%e7%bb%b4%e4%bf%ae" title="查看 故障维修 的全部文章" target="_blank">故障维修</a></span>：有的时候将档位打到mv档的时候，仪表显示<strong>OL</strong>，并不是说该仪表损坏，需要将挡位打到别的挡，在打到mv档，如果仪表显示<strong>0.000</strong>的话，则说明mv挡位正常，如果每次打到mv挡都显示<strong>OL</strong>则说明<strong>B</strong><strong>FS9</strong><strong>721</strong>已经损坏需要更换FS9721进行修复。</p>
<p>&nbsp;</p>
<p><strong>其他Fluke 15B 与<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/f17b" title="查看 F17B 的全部文章" target="_blank">F17B</a></span>维修参考：</strong></p>
<p><strong>点击</strong>：<a href="http://www.faxytech.com/archives/f15-f17-wx.html">FLUKE 15B+与17B+维修故障1</a><strong><a href="http://www.faxytech.com/archives/f15-f17-wx.html">：</a></strong><a title="福禄克F15B+和F17B+电路故障维修经验系列- 电表开机无任何显示" href="http://www.faxytech.com/archives/f15-f17-wx.html">电表开机无任何显示</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-wx2.html">FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-wx3.html">FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障4：AC/DC 电流挡不能测量故障" href="http://www.faxytech.com/archives/f15b-f17b-wx4.html">FLUKE 15B+与17B+维修故障4：AC/DC 电流挡不能测量故障</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障5：17B 温度挡不能测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-5.html">FLUKE 15B+与17B+维修故障5：17B 温度挡不能测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点" href="http://www.faxytech.com/archives/f15-f17-wx6.html">FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点</a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/f15b-f17b-wx2.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克F15B+和F17B+电路故障维修经验系列- 电表开机无任何显示</title>
		<link>http://www.faxytech.com/archives/f15-f17-wx.html</link>
		<comments>http://www.faxytech.com/archives/f15-f17-wx.html#comments</comments>
		<pubDate>Tue, 17 May 2016 07:13:00 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[F15B+维修]]></category>
		<category><![CDATA[F17B+维修]]></category>
		<category><![CDATA[fluke万用表维修]]></category>
		<category><![CDATA[fluke维修]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7596</guid>
		<description><![CDATA[导读：福禄克F15B+和F17B+电路故障维修经验系列，下面的图上我们可以看出F15B和F17B的区别在于15B没有温度测量功能，而F17B有温度测量功能，F15B比F17B少了两个按钮，分别足相对值REL和频率，其... ]]></description>
			<content:encoded><![CDATA[<table cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="0.866667" height="0"></td>
</tr>
<tr>
<td></td>
<td><span style="font-size: 13px; line-height: 19px;">导读：福禄克F15B+和F17B+电路故障维修经验系列，下面</span><span style="font-size: 13px; line-height: 19px;">的图上我们可以看出F</span><span style="font-family: 'Times New Roman';">15</span><span style="font-size: 13px; line-height: 19px;">B和F</span><span style="font-family: 'Times New Roman';">17</span><span style="font-size: 13px; line-height: 19px;">B的区别在于</span><span style="font-family: 'Times New Roman';">15</span><span style="font-size: 13px; line-height: 19px;">B没有<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>测量功能，而F</span><span style="font-family: 'Times New Roman';">17</span><span style="font-size: 13px; line-height: 19px;">B有温度测量功能，F</span><span style="font-family: 'Times New Roman';">15</span><span style="font-size: 13px; line-height: 19px;">B比F</span><span style="font-family: 'Times New Roman';">17</span><span style="font-size: 13px; line-height: 19px;">B少了两个按钮，分别足相对值REL和频率，其实F</span><span style="font-family: 'Times New Roman';">15B</span><span style="font-family: 宋体;">改造F</span><span style="font-family: 'Times New Roman';">17B</span><span style="font-family: 宋体;">非常简单，F</span><span style="font-family: 'Times New Roman';">15B</span><span style="font-family: 宋体;">就是用的F</span><span style="font-family: 'Times New Roman';">17B</span><span style="font-family: 宋体;">的板，导电开关己经印刷在板子上了，只要加上两个按钮，在加上三个运放和两个电位器就可以改造成</span><span style="font-family: 'Times New Roman';">17B</span><span style="font-family: 宋体;">并且有温度测量功能。</span>&nbsp;</p>
<p>&nbsp;</p>
<p>下面为福禄克<span style="font-family: 'Times New Roman';">15B/17B</span><span style="font-family: 宋体;">的拆机图，他们的区别就是在于少了三个运放和两个电位器，从图上我们可以着出该<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fluke-multimeter" title="Fluke福禄克万用表">万用表</a></span>采用台湾富晶公司生产的</span>FS9721_LP3带微处理器的3/4<span style="font-family: 宋体;">位</span>AD转换器，该A/D转换器集成电压，电流，电阻，蜂鸣，频率，AC/DC转换（内置运算放人器）等功能，外接4M石英晶体振荡器做时钟振荡器，16脚的IC为HC148是一个异或门是用在小数点驱动电路作用是驱动小数点进行动态显示，左面有一个八脚IC<span style="font-family: 宋体;">，</span><span style="font-family: 'Times New Roman';">LT</span>1097<span style="font-family: 宋体;">， </span><span style="font-family: 'Times New Roman';">1097 </span><span style="font-family: 宋体;">下面有个五脚的</span>IC LMC7111， mA插孔附近也有一个五角的IC<span style="font-family: 宋体;">，</span><span style="font-family: 'Times New Roman';">TMP35</span> ，这三个IC分别做温度挡测量电路，做温度/<span style="font-family: 宋体;">电压转换。</span></p>
<p><span style="font-family: 宋体;"><a href="http://www.faxytech.com/wp-content/uploads/2016/05/fluke-15b-xl.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7597" title="福禄克15B+与F17B+万用表电路板" src="http://www.faxytech.com/wp-content/uploads/2016/05/fluke-15b-xl.png" alt="福禄克15B+与F17B+万用表电路板" width="608" height="639" /></a></span></p>
<h4>Fluke 15B+与Fluke 17B+电表开机无任何显示：</h4>
<p>首先要检<span style="font-family: 'Times New Roman';">3V</span><span style="font-family: 宋体;">电源电池是否有电，如果</span><span style="font-family: 'Times New Roman';">3V</span><span style="font-family: 宋体;">电源正常，则第二步要检测电池触片是否氧化，接触不良，电池触片折断，与电路板开焊等，如果都没问题，第三部分检查波段开关，下图中的</span><span style="font-family: 'Times New Roman';">S1</span><span style="font-family: 宋体;">，是否出现波段开关</span><span style="font-family: 'Times New Roman';">V</span><span style="font-family: 宋体;">子片变形接触不良，导致电表无显示，如果都都没有问题，则要重点检测液晶屏和导电胶，是否导电橡胶氧化或液晶显示屏损坏导致无法显示，如果导电橡胶和液晶屏均正常，则要检查主芯片部分。首先检查主芯片工作条件</span><span style="font-family: 'Times New Roman';">3V</span><span style="font-family: 宋体;">电源加到</span><span style="font-family: 'Times New Roman';">48</span><span style="font-family: 宋体;">脚和</span><span style="font-family: 'Times New Roman';">44</span><span style="font-family: 宋体;">脚，两只表笔分别测量</span><span style="font-family: 'Times New Roman';">48</span><span style="font-family: 宋体;">脚和</span><span style="font-family: 'Times New Roman';">44</span><span style="font-family: 宋体;">脚必须要有</span><span style="font-family: 'Times New Roman';">2.8V</span><span style="font-family: 宋体;">以上电源，如果没有就是</span><span style="font-family: 'Times New Roman';">S1</span><span style="font-family: 宋体;">开关到</span><span style="font-family: 'Times New Roman';">9721</span><span style="font-family: 宋体;">的</span><span style="font-family: 'Times New Roman';">48</span><span style="font-family: 宋体;">脚有开路，如果有</span><span style="font-family: 'Times New Roman';">2.8V</span><span style="font-family: 宋体;">电源电表无显示则要检查外接</span><span style="font-family: 'Times New Roman';">4M</span><span style="font-family: 宋体;">晶振是否起振，如果晶振没问题，电表还无显示，那边则说明</span><span style="font-family: 'Times New Roman';">FS9721_LP3</span><span style="font-family: 宋体;">性能不良，虚焊或击穿导致电表无法开机，如果</span><span style="font-family: 'Times New Roman';">FS9721_LP3</span><span style="font-family: 宋体;">击穿的话，整机电流会很大的直接更换主芯片即可修复。</span></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/05/FS9721_LP3.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7598" title="FS9721_LP3" src="http://www.faxytech.com/wp-content/uploads/2016/05/FS9721_LP3.png" alt="FS9721_LP3" width="592" height="399" /></a></p>
<p><span style="font-family: 宋体;"><br />
</span></p>
<p><strong>其他Fluke 15B 与F17B维修参考：</strong></p>
<p><strong>点击</strong>：<a href="http://www.faxytech.com/archives/f15-f17-wx.html">FLUKE 15B+与17B+维修故障1</a><strong><a href="http://www.faxytech.com/archives/f15-f17-wx.html">：</a></strong><a title="福禄克F15B+和F17B+电路故障维修经验系列- 电表开机无任何显示" href="http://www.faxytech.com/archives/f15-f17-wx.html">电表开机无任何显示</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-wx2.html">FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-wx3.html">FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障4：AC/DC 电流挡不能测量故障" href="http://www.faxytech.com/archives/f15b-f17b-wx4.html">FLUKE 15B+与17B+维修故障4：AC/DC 电流挡不能测量故障</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障5：17B 温度挡不能测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-5.html">FLUKE 15B+与17B+维修故障5：17B 温度挡不能测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点" href="http://www.faxytech.com/archives/f15-f17-wx6.html">FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点</a></p>
<p>&nbsp;</p>
<p><span style="font-family: 宋体;"><br />
</span></td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/f15-f17-wx.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克维修小技巧:DTX-1800升级的时候断电故障</title>
		<link>http://www.faxytech.com/archives/wexiu_dtx1800.html</link>
		<comments>http://www.faxytech.com/archives/wexiu_dtx1800.html#comments</comments>
		<pubDate>Tue, 10 Nov 2015 06:53:25 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[DTX1800升级]]></category>
		<category><![CDATA[fluke维修]]></category>
		<category><![CDATA[福禄克维修]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6979</guid>
		<description><![CDATA[深圳连讯达维修部工程师为大家讲解福禄克维修小技巧：DTX-1800升级的时候断电故障。我们在升级福禄克DTX-1800仪器或者DTX-1500，DTX-1200，DTX-LT等福禄克测试仪的时候，我们是不能断电的。因为如... ]]></description>
			<content:encoded><![CDATA[<p>深圳连讯达维修部工程师为大家讲解<span class='wp_keywordlink'><a href="http://www.faxytech.com/fluke-maintenance" title="福禄克维修">福禄克维修</a></span>小技巧：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>升级的时候断电故障。我们在升级福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-1800仪器或者<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1500.html " title="福禄克FLuke DTX-1500">DTX-1500</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-lt.html" title="福禄克FLUKE DTX-LT测试仪">DTX-LT</a></span>等福禄克测试仪的时候，我们是不能断电的。因为如果福禄克电池电量不够，就会出现故障。</p>
<p><span style="color: #ff0000;"><strong>现象1：福禄克DTX-1800屏幕变白.</strong></span></p>
<p><span style="color: #ff0000;"><strong>现象2：福禄克DTX-1800 ?的USB线缆无反应。</strong></span></p>
<p>连讯达工程师提示您，可以尝试以下步骤。</p>
<p>— 关掉DTX<span style="font-family: 宋体;">系列仪器（</span><span style="font-family: Arial;">DTX-1800</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-1500</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-1200</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-LT</span><span style="font-family: 宋体;">等）。</span></p>
<p><span style="font-family: 宋体;">—</span> 按下【灯光】键和【Talk<span style="font-family: 宋体;">】键。</span></p>
<p>— 保持他们按下状态，打开DTX<span style="font-family: 宋体;">仪器。</span></p>
<p><span style="font-family: 宋体;">—</span>松开这些键。</p>
<p>— 等待DTX-1800<span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-1500</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-1200</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-LT</span><span style="font-family: 宋体;">更新成功。</span></p>
<p><span style="font-family: 宋体;">—</span> 使用linware?<span style="font-family: 宋体;">软件，</span><span style="font-family: Calibri;">DTX</span><span style="font-family: 宋体;">系列仪器通过</span><span style="font-family: Calibri;">USB</span><span style="font-family: 宋体;">连接电脑开始更新。</span></p>
<p><span style="font-family: 宋体;"><br />
</span></p>
<h4><span style="font-family: 宋体;">如果福禄克DTX-1800远端出现了故障。用USB线连接远端。</span></h4>
<p>— 关掉DTX系列仪器（DTX-1800，DTX-1500，DTX-1200，DTX-LT等）。</p>
<p>—?按下【灯光】键和【Talk】键。</p>
<p>— 保持他们按下状态，打开DTX仪器。</p>
<p>—松开这些键。</p>
<p>— 等待DTX-1800，DTX-1500，DTX-1200，DTX-LT更新成功。</p>
<p>—?使用linware?软件，DTX系列仪器通过USB连接电脑开始更新。</p>
<p>&nbsp;</p>
<p><strong>其他故障现象：</strong></p>
<p>现象3：主机无法开机，辅机无法开机。</p>
<p>现象4：找不到远端。</p>
<p>现象5：测试参数差。</p>
<p>现象5：接线图故障，通道接口维修。</p>
<p><span style="color: #ff0000;"><strong>请联系连讯达维修：13715297556许工0755-83999818-801</strong></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/wexiu_dtx1800.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Fluke维修：福禄克DSX-5000辅机(远端机)所有灯常长亮。</title>
		<link>http://www.faxytech.com/archives/dsx5000-light.html</link>
		<comments>http://www.faxytech.com/archives/dsx5000-light.html#comments</comments>
		<pubDate>Thu, 22 Oct 2015 03:10:19 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[DSX5000远端机灯亮]]></category>
		<category><![CDATA[fluke维修]]></category>
		<category><![CDATA[灯常亮]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6915</guid>
		<description><![CDATA[Fluke维修小技巧，深圳连讯达教您自己动手解决福禄克DSX-5000辅机(远端机)所有灯常长亮。 近期深圳连讯达收到有客户反映，福禄克DSX-5000的仪器的远端机，开机的时候，远端机常亮，不自动关... ]]></description>
			<content:encoded><![CDATA[<p>Fluke维修小技巧，深圳连讯达教您自己动手解决福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>辅机(远端机)所有灯常长亮。</p>
<p>近期深圳连讯达收到有客户反映，福禄克<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-5000" title="查看 DSX-5000 的全部文章" target="_blank">DSX-5000</a></span>的仪器的远端机，开机的时候，远端机常亮，不自动关闭。正常情况下，当福禄克DSX-5000开机的时候，仪器将会进行自检过程，如果您的远端机常亮并且不关闭。它可能出现了软件故障。你需要做如下操作：</p>
<p>1、关掉仪器<br />
2、同时按照TLAK键和TEST键。<br />
3、保持TLAK键和TEST键，然后开机。<br />
4、如果是所以灯还是亮。那么更新DSX-5000软件。</p>
<p>如果更新:http://www.faxy-tech.com/info/dsx5000-update.html</p>
<p>如果您对不是太懂，建议联系<span class='wp_keywordlink'><a href="http://www.faxytech.com/fluke-maintenance" title="福禄克维修">福禄克维修</a></span>点连讯达，进行最新的软件版更新。</p>
<p>&nbsp;</p>
<p>福禄克DSX-5000介绍：福禄克FLuke?DSX-5000 CableAnalyzer 可提高<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>认证的速度，Cat 6A 和 F<sub>A</sub> 级测试速度无可比拟，且符合最严苛的 IEC 草案 V 级精度标准。ProjX 管理系统有助于确保在第一次操作时就正确完成作业，并且有助于跟踪从设置到系统验收过程的进度。<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> 平台支持光纤测试模块（OLTS 和?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>），以及 Wi-Fi 分析和以太网故障排除。该平台易于升级以支持未来标准。使用 Taptive 用户界面更快速地进行故障排除，该界面可以图形方式显示故障源，包括串扰、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>和屏蔽故障。分析测试结果并使用?<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>? 管理软件创建专业的测试报告。</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2013/06/Fluke-DSX-50001.jpg" class="highslide-image" onclick="return hs.expand(this);"><img title="福禄克Fluke DSX-5000" src="http://www.faxytech.com/wp-content/uploads/2013/06/Fluke-DSX-50001.jpg" alt="福禄克Fluke DSX-5000" width="281" height="222" /></a></p>
<p><img src="file:///d:/users/administrator/appdata/roaming/360se6/User Data/temp/Fluke-DSX-50001.jpg" alt="" /></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx5000-light.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DTX1800测试RL损耗损耗不过奇怪状况</title>
		<link>http://www.faxytech.com/archives/dtx1800-rl.html</link>
		<comments>http://www.faxytech.com/archives/dtx1800-rl.html#comments</comments>
		<pubDate>Thu, 14 Aug 2014 01:23:44 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DTX1800故障]]></category>
		<category><![CDATA[fluke维修]]></category>
		<category><![CDATA[RL]]></category>
		<category><![CDATA[回波损耗]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=4470</guid>
		<description><![CDATA[客户问：Fluke DTX-1800正常测试情况下，出现如下问题：测试一根线RL不良之后，接着后面测试的线均不良，将测试仪的适配器拔出再插上继续进行测试，前面那根不良线又测试OK了，但测试一段... ]]></description>
			<content:encoded><![CDATA[<p>客户问：Fluke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>正常测试情况下，出现如下问题：测试一根线<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/rl" title="查看 RL 的全部文章" target="_blank">RL</a></span>不良之后，接着后面测试的线均不良，将测试仪的适配器拔出再插上继续进行测试，前面那根不良线又测试OK了，但测试一段时间又会出现同样的问题。请问有可能是什么原因？</p>
<p><strong>福禄克资深工程师回答：</strong>该换插座了，另外检查一下是否已经多次更换过插座，一般支持更换20-30次（依使用的野蛮程度定）。</p>
<p>客户问：没有那么多 ，最多换过3-5次</p>
<p><strong>福禄克资深工程师回答：</strong>如果只有3-5次，可以先看看适配器与机器借口是否有松动，打开<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克DTX 1800">DTX1800</a></span>适配器看看插座接口是否有松动，打开适配器还是要注意防静电的，南方用户这个季节可忽略静电问题。（夏季）</p>
<p>客户问：1、跳线测试和通道测试均出现上面所说的现象；2、其中跳线测试有换过很5、6次JACK，通道测试没有换过JACK；3、适配器与机器接口未见到有松动。请问还有什么故障可嫌疑的吗？</p>
<p><strong>福禄克资深工程师回答：</strong>1。被测链路/跳线有多长?短链路不要用通道适配器进行测试。2。(拆开)<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-patchcord-adapter.html" title="跳线适配器">跳线适配器</a></span>Jack基座检查否？有无松动？</p>
<p>大家可以尝试以上方法自己排除问题，如果还不能解决请联系连讯<span class='wp_keywordlink'><a href="http://www.faxytech.com/fluke-maintenance" title="福禄克维修">福禄克维修</a></span>中心。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dtx1800-rl.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>