<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; Fiber QuickMap</title>
	<atom:link href="http://www.faxytech.com/tag/fiber-quickmap/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>福禄克光纤测试仪的区别？如何正确选择一级二级测试的设备？</title>
		<link>http://www.faxytech.com/archives/choose-fluke.html</link>
		<comments>http://www.faxytech.com/archives/choose-fluke.html#comments</comments>
		<pubDate>Wed, 28 Oct 2020 01:59:17 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[Fiber QuickMap]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[MultiFiber Pro]]></category>
		<category><![CDATA[VisiFault]]></category>
		<category><![CDATA[福禄克网络]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11776</guid>
		<description><![CDATA[今天和大家一起更深入地走进福禄克网络的产品，帮助大家能够更快地找到适合自己工作需求的“得力助手” 。 &#160; 首先为大家介绍一下福禄克网络都有哪些测试光纤的产品，我们根据不同... ]]></description>
			<content:encoded><![CDATA[<p>今天和大家一起更深入地走进<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b%e7%bd%91%e7%bb%9c" title="查看 福禄克网络 的全部文章" target="_blank">福禄克网络</a></span>的产品，帮助大家能够更快地找到适合自己工作需求的“得力助手” 。</p>
<p>&nbsp;</p>
<p>首先为大家介绍一下福禄克网络都有哪些测试光纤的产品，我们根据不同的使用场景和不同类型主要分为三大类：</p>
<p>第一类是认证级仪表，它是根据标准对光纤链路进行认证，并给出测试报告是否合规，这类仪表均属于同一平台，其模块化设计，可根据需求更换模块，进行不同的测试内容。其中包括T1一级测试（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> PRO）、T2二级测试(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span> PRO)，事实上，这里也应该包括认证级光纤端面检测（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fiberinspector-mini.html" title="FiberInspector 袖珍光纤视频显微镜">FiberInspector</a></span>）产品FI-7000 &amp;<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fi-3000-mpo.html" title="福禄克FLUKE FI-3000">FI-3000</a></span>，但是为了让分类更清晰化，我们将光纤端面检测类的产品归在了一起做介绍。</p>
<p>第二类是我们刚才提到的光纤端面检测设备，其中有两款属于认证级，一个是FI-7000另一个是FI-3000，FI-3000是针对<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span>光纤端面进行检测的，我们单独把光纤端面检测类的产品设为一类，还有一个更为重要的原因，是因为光纤很大一部分故障都是由于光纤端面脏污引起的，这也是为什么标准中加入了光纤端面检测部分；</p>
<p>第三类属于维护和故障诊断类仪表，包括断点定位设备（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-quickmap.html" title="福禄克Fluke Fiber QuickMap">Fiber QuickMap</a></span>）；光纤损耗测试工具（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/simplifiber-pro.html" title="福禄克FLUKE SimpliFiber Pro光纤测试仪">SimpliFiber</a></span> PRO）；MPO<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="MultiFiber Pro">MultiFiber Pro</a></span>）；还有可视故障定位仪（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/visifault.html" title="福禄克FLUKE VISIFAULT红光笔">VisiFault</a></span>），也就是我们常说的红光笔，这类产品主要是满足对光纤链路日常维护所使用的。</p>
<p>接下来介绍一下不同场景下经常使用哪些产品。使用场景我们分为两大类，第一类是新建或升级的机房（数据中心），大家都知道数据链路的可靠、稳定传输是保障网络运行的基础，尤其是在网络飞速发展的今天，还要为我们的网络留有一定的冗余空间来应对速率的不断提升，那么我们如何做到这点呢？又如何检测其质量呢？</p>
<p>&nbsp;</p>
<p>在新建或升级机房（数据中心）的时候做好数据链路的认证、合规测试是非常重要的。在这里我们需要涉及到的设备有认证级仪表、认证级光纤端面检测仪表和必要的光纤清洁工具，也就是我们前面提到的CFP、OFP、FI-7000（FI-3000）这几类产品。适用对象为布线系统专业人员，在进行工程验收测试上置信度是最为严格的，所有的测试都是依据标准进行的；另一类是日常维护，故障检测。主要涉及到的产品除了我们之前提到的维护类工具外，还包括<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>（OFP），提供合规、更为智能、简单、可视化的故障定位分析仪，当然还要包括必不可少的光纤端面检测设备和清洁工具。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/choose-fluke.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克网络分析仪	多模光纤测试仪Fiber QuickMap</title>
		<link>http://www.faxytech.com/archives/fiber-quickmap-tech.html</link>
		<comments>http://www.faxytech.com/archives/fiber-quickmap-tech.html#comments</comments>
		<pubDate>Fri, 02 Jun 2017 12:19:49 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[Fiber QuickMap]]></category>
		<category><![CDATA[光纤测试仪]]></category>
		<category><![CDATA[网络分析仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8906</guid>
		<description><![CDATA[福禄克网络分析仪 多模光纤测试仪Fiber QuickMap ·用于多模光纤，50/125?m，62.5/125 ?m·850 nm 输出波长几秒时间内检测长达 4,921 英尺（1,500 米）的光纤·定位多模光纤中的严重弯曲、高损失接合处、... ]]></description>
			<content:encoded><![CDATA[<p>福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/network" title="网络分析仪">网络分析仪</a></span>	多模<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-quickmap.html" title="福禄克Fluke Fiber QuickMap">Fiber QuickMap</a></span></p>
<p>·用于多模光纤，50/125?m，62.5/125 ?m·850 nm 输出波长几秒时间内检测长达 4,921 英尺（1,500 米）的光纤·定位多模光纤中的严重弯曲、高损失接合处、断路和脏连接器</p>
<p>·测量和定位高损耗接头</p>
<p>·定位光纤末端</p>
<p>·发现由光纤端面污染或连接不良造成的高误码率根源</p>
<p>·开始测试之前，检测活跃的光纤信号</p>
<p>·快速设置。连接光纤并按下“测试”按钮。无需冗长的设置·快速找到问题。六秒测试时间 — 无需长达数小时的盲目故障诊断</p>
<p>·更改折射率 (IOR) 以提高光纤长度精度</p>
<p>·在昏暗区域也清晰易读。背光照明显示屏带自动关断功能</p>
<p>·可拆卸 SC 适配器非常容易清洁</p>
<p>·可以选配 LC、ST 和 FT 可更换适配器</p>
<p>·电池寿命长， 可执行 1,500 次测试（典型值）</p>
<p>·结构坚固；经过振动和 1 米跌落试验	（投标人填写）</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/fiber-quickmap-tech.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克Fiber QuickMap灯闪烁故障</title>
		<link>http://www.faxytech.com/archives/quickmap-active-line.html</link>
		<comments>http://www.faxytech.com/archives/quickmap-active-line.html#comments</comments>
		<pubDate>Fri, 23 Sep 2016 00:44:03 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[Fiber QuickMap]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8087</guid>
		<description><![CDATA[我们在使用福禄克Fiber QuickMap时候，有时候会发现Fiber QuickMap灯闪烁故障。当我们把Fiber QuickMAP插入一个850nm的激光光源，并且按下TEST键的时候，福禄克的Fiber QuickMap讲显示下面的屏幕。这个时候... ]]></description>
			<content:encoded><![CDATA[<h3 id="article-title"><span style="font-size: 13px; font-weight: normal;">我们在使用<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-quickmap.html" title="福禄克Fluke Fiber QuickMap">Fiber QuickMap</a></span>时候，有时候会发现<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fiber-quickmap" title="查看 Fiber QuickMap 的全部文章" target="_blank">Fiber QuickMap</a></span>灯闪烁故障。</span><span style="font-size: 13px; font-weight: normal;">当我们把Fiber QuickMAP插入一个850nm的激光光源，并且按下TEST键的时候，福禄克的Fiber QuickMap讲显示下面的屏幕。这个时候请尽快断开福禄克测试仪。</span></h3>
<div id="article-body"><span>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/FiberQuickMapActiveLineFlashing.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8088" title="FiberQuickMapActiveLineFlashing" src="http://www.faxytech.com/wp-content/uploads/2016/09/FiberQuickMapActiveLineFlashing.gif" alt="" width="162" height="350" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p></span></div>
<div>福禄克Fiber QuickMAP设计是承受是-7dbm光源（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/vcsel.html" title="VCSEL垂直腔面发射激光管">VCSEL</a></span>光源一般是-6dbm)。单光源大于仪器承受范围，设备会损坏。如果出现了故障，请联系连讯达。</div>
<div></div>
<div></div>
<h3><strong>福禄克Fiber QuickMAP产品简介：</strong></h3>
<div>
<div id="3365q">
<div><strong>一键式测试</strong></div>
</div>
<div id="3365a">
<p>Fiber QuickMap 可直接用在箱子外面而无需用户设置。只要打开它，连接到要测试的多模链路，然后按下“TEST”按钮即可获得所需通道的可视性，从而能快速排除故障或验证连通性。无需修改设置、光纤类型或标准。</p>
</div>
<p><a name="3366"></a></p>
<div id="3366q">
<div><strong>六秒钟故障排除</strong></div>
</div>
<div id="3366a">
<p>Fiber QuickMap 故障排除工具，是一种单端设备，将您的故障排除时间从几小时减少到几秒钟。它的平均测试时间为六秒，可快速提供可视性和必要的数据以找出并修复多模光纤布线的任何问题。通常用于故障排除的工具普遍是低效、无效的，或两者兼而有之。可视化故障定位仪、激光器或手电筒，尽管很容易使用，但极大限制了故障排除的能力，因为他们无法分辨或找出有问题的损耗或反射事件。它们还要求用户在追踪布线长度时与其保持视觉接触以找到故障。这一过程不仅耗时，也是不现实的，因为在许多数据中心和校园环境中链路是在地砖下、墙后或地下运行。功率表和源头于测试整个通道以验证功率和损耗是重要的，但对于故障排除是低效的，因为用户必须按顺序挨个测试通道链路，这可能要花几个小时，取决于通道的长度和链路的数量。</p>
</div>
<p><a name="3364"></a></p>
<div id="3364q">
<div><strong>获取多模通道的关键可视性</strong></div>
</div>
<div id="3364a">
<p>对通道中所有连接事件的可视性是很重要的，因为他们是企业环境中大部分光纤故障出现的地方。Fiber QuickMap 故障排除工具可显示整个链路中多个* 连接事件的距离，直至链路的末端（或断点）。</p>
<p>* 最多可显示九个事件</p>
</div>
<p><a name="3362"></a></p>
<div id="3362q">
<div><strong>找出误码率的原因</strong></div>
</div>
<div id="3362a">
<p>虽然连接器反射在光纤布线中是一种正常的现象，但反射过多实际上可以引起问题，尤其是在高带宽（10+ Gbps）系统。过度反射（通常由端面变脏或打磨差造成）干扰发射机输出，从而导致误码问题。如果能找到并测量高反射事件，可有助于优化网络性能。</p>
</div>
<p><a name="3363"></a></p>
<div id="3363q">
<div><strong>找出企业光纤故障最常见的原因</strong></div>
</div>
<div id="3363a">
<p>发现多模通道中高损耗的事件是至关重要的，因为他们是大多数企业的光纤故障源。这些宏弯、受污染或损坏的光纤端面，可能导致高损耗，但使用可视化故障定位仪、手电筒和功率表是看不到它们的。然而，凭借 Fiber QuickMap，用户可以快速定义损耗阈值来标记并找出高损耗的事件。</p>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/quickmap-active-line.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【福禄克】FLUKE Fiber QuickMap 多模光纤一键故障诊断</title>
		<link>http://www.faxytech.com/archives/fluke-fiber-quickmap.html</link>
		<comments>http://www.faxytech.com/archives/fluke-fiber-quickmap.html#comments</comments>
		<pubDate>Thu, 21 Jul 2011 10:31:41 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[福禄克光缆测试产品]]></category>
		<category><![CDATA[Fiber QuickMap]]></category>
		<category><![CDATA[FLUKE Fiber QuickMap]]></category>
		<category><![CDATA[光纤测试]]></category>
		<category><![CDATA[光纤测试仪]]></category>
		<category><![CDATA[多模光纤一键故障诊断]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=1265</guid>
		<description><![CDATA[FLUKE Fiber QuickMap 多模光纤一键故障诊断一键测试概览 一键测试 &#8211; 无需用户设置即可使用 六秒测试时间，避免长达数小时的盲目故障诊断 定位通道中的多个事件，全面掌握可能有问题的链... ]]></description>
			<content:encoded><![CDATA[<h4>FLUKE <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-quickmap.html" title="福禄克Fluke Fiber QuickMap">Fiber QuickMap</a></span> <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%a4%9a%e6%a8%a1%e5%85%89%e7%ba%a4%e4%b8%80%e9%94%ae%e6%95%85%e9%9a%9c%e8%af%8a%e6%96%ad" title="查看 多模光纤一键故障诊断 的全部文章" target="_blank">多模光纤一键故障诊断</a></span>一键测试概览</h4>
<p><a href="http://www.faxytech.com/wp-content/uploads/2011/07/Fiber-QuickMap.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignright size-full wp-image-1266" title="福禄克Fluke Fiber QuickMap" src="http://www.faxytech.com/wp-content/uploads/2011/07/Fiber-QuickMap.jpg" alt="福禄克Fluke Fiber QuickMap" width="246" height="187" /></a>一键测试 &#8211; 无需用户设置即可使用</p>
<p>六秒测试时间，避免长达数小时的盲目故障诊断</p>
<p>定位通道中的多个事件，全面掌握可能有问题的链路和连接</p>
<p>定位高损失事件或断路，这些是多模光纤故障的最常见原因</p>
<p>定位和测量高反射事件，这是导致网络性能降低和高误码率的原因</p>
<p>各种工具包配置，包括其他诊断工具，如功率表、光源和光纤检测显微镜，方便实现“光纤最佳实践”，提高技术人员的故障诊断能力</p>
<div id="box_overview">
<h4>FLUKE <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fiber-quickmap" title="查看 Fiber QuickMap 的全部文章" target="_blank">Fiber QuickMap</a></span> 多模光纤一键故障诊断一键测试概述</h4>
<p>为支持 10、40，和 100 千兆流量，企业网中安装了越来越多的 OM3 和 OM4 多模光纤，光纤设施的可靠性也变得越来越重要。因此，企业技术人员对整个光纤通道中的一个组件进行测量和故障诊断以避免网络故障（或迅速恢复）的基本能力就成为“光纤最佳实践”之一。技术人员用反复试验的方法花费大量时间进行诊断，最终问题升级到由有 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span> 经验的技术人员来解决的方法已经行不通。每个技术人员都应有一套几秒内即可找到问题所在的方便工具。</p>
<p><span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> 的 Fiber QuickMap 即是一种可迅速有效地找到多模光纤中的连接和断路问题的企业光纤故障诊断工具。由于 Fiber QuickMap 可迅速提供高损失和高反射事件等故障的距离，它已成为所有光纤技术人员不可或缺的故障诊断工具。</p>
</div>
<div id="box_features">
<h4><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fluke-fiber-quickmap" title="查看 FLUKE Fiber QuickMap 的全部文章" target="_blank">FLUKE Fiber QuickMap</a></span> 多模光纤一键故障诊断一键测试特性</h4>
<p><a name="3365"></a></p>
<div id="3365q">
<div><strong>一键式测试</strong></div>
</div>
<div id="3365a">
<p>Fiber QuickMap 可直接用在箱子外面而无需用户设置。只要打开它，连接到要测试的多模链路，然后按下“TEST”按钮即可获得所需通道的可视性，从而能快速排除故障或验证连通性。无需修改设置、光纤类型或标准。</p>
</div>
<p><a name="3366"></a></p>
<div id="3366q">
<div><strong>六秒钟故障排除</strong></div>
</div>
<div id="3366a">
<p>Fiber QuickMap 故障排除工具，是一种单端设备，将您的故障排除时间从几小时减少到几秒钟。它的平均测试时间为六秒，可快速提供可视性和必要的数据以找出并修复多模光纤布线的任何问题。通常用于故障排除的工具普遍是低效、无效的，或两者兼而有之。可视化故障定位仪、激光器或手电筒，尽管很容易使用，但极大限制了故障排除的能力，因为他们无法分辨或找出有问题的损耗或反射事件。它们还要求用户在追踪布线长度时与其保持视觉接触以找到故障。这一过程不仅耗时，也是不现实的，因为在许多数据中心和校园环境中链路是在地砖下、墙后或地下运行。功率表和源头于测试整个通道以验证功率和损耗是重要的，但对于故障排除是低效的，因为用户必须按顺序挨个测试通道链路，这可能要花几个小时，取决于通道的长度和链路的数量。</p>
</div>
<p><a name="3364"></a></p>
<div id="3364q">
<div><strong>获取多模通道的关键可视性</strong></div>
</div>
<div id="3364a">
<p>对通道中所有连接事件的可视性是很重要的，因为他们是企业环境中大部分光纤故障出现的地方。Fiber QuickMap 故障排除工具可显示整个链路中多个* 连接事件的距离，直至链路的末端（或断点）。</p>
<p>* 最多可显示九个事件</p>
</div>
<p><a name="3362"></a></p>
<div id="3362q">
<div><strong>找出误码率的原因</strong></div>
</div>
<div id="3362a">
<p>虽然连接器反射在光纤布线中是一种正常的现象，但反射过多实际上可以引起问题，尤其是在高带宽（10+ Gbps）系统。过度反射（通常由端面变脏或打磨差造成）干扰发射机输出，从而导致误码问题。如果能找到并测量高反射事件，可有助于优化网络性能。</p>
</div>
<p><a name="3363"></a></p>
<div id="3363q">
<div><strong>找出企业光纤故障最常见的原因</strong></div>
</div>
<div id="3363a">
<p>发现多模通道中高损耗的事件是至关重要的，因为他们是大多数企业的光纤故障源。这些宏弯、受污染或损坏的光纤端面，可能导致高损耗，但使用可视化故障定位仪、手电筒和功率表是看不到它们的。然而，凭借 Fiber QuickMap，用户可以快速定义损耗阈值来标记并找出高损耗的事件。</p>
</div>
</div>
<div id="box_models_&amp;_accessories">
<h4>FLUKE Fiber QuickMap 多模光纤一键故障诊断一键测试型号和配件</h4>
<div>型号</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>FQM-MAIN</td>
<td>Fiber QuickMap 企业光纤故障诊断工具和随身包</td>
</tr>
<tr>
<td>FQM-KIT</td>
<td>Fiber QuickMap 故障诊断套件：包括 Fiber QuickMap、SC/ SC 和 SC/LC（50 和 62.5 μm）混合测试参考线和随身包</td>
</tr>
<tr>
<td>FTS900</td>
<td>Fiber QuickMap 故障诊断套件：包括 Fiber QuickMap、SC/ LC（50 和 62.5 μm）混合测试参考线、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/visifault.html" title="福禄克FLUKE VISIFAULT红光笔">VisiFault</a></span> VFL 和随身包</td>
</tr>
<tr>
<td>FTS1000</td>
<td>Fiber QuickMap 故障诊断套件：包括 Fiber QuickMap、SC/SC 和 SC/LC（50 和 62.5μm）混合测试参考线、VisiFault VFL、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/simplifiber-pro.html" title="福禄克FLUKE SimpliFiber Pro光纤测试仪">SimpliFiber</a></span> Pro 功率表和多模源和便携箱</td>
</tr>
<tr>
<td>FTS1100</td>
<td>Fiber QuickMap 故障诊断套件：包括 Fiber QuickMap、SC/SC 和 SC/LC（50 和 62.5μm）混合测试参考线、VisiFault VFL、SimpliFiber Pro 功率表和多模光源、FT500 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fiberinspector-mini.html" title="FiberInspector 袖珍光纤视频显微镜">FiberInspector</a></span> Mini 视频显微镜和便携箱</td>
</tr>
<tr>
<td>SFPOWERMETER</td>
<td>包括 SimpliFiber Pro 光功率计、SC 适配器</td>
</tr>
<tr>
<td>SFMULTIMODESOURCE</td>
<td>SimpliFiber Pro 多模 850/1300 光源</td>
</tr>
<tr>
<td>FT525</td>
<td>FiberInspector Mini 和清洁套件：包括 FiberInspector Mini；全套清洁工具（清洁管、十张清洁卡、溶剂笔、2.5mm 端口清洁棉签和 1.25mm 端口清洁棉签）和便携箱</td>
</tr>
<tr>
<td>NFC-Kit-Case</td>
<td>光纤清洁套件和便携箱</td>
</tr>
<tr>
<td>NFC-Kit-Box</td>
<td>光纤清洁套件</td>
</tr>
<tr>
<td>NFK2-1SMPLX-SC</td>
<td>参考测试线，62.5/125 μm，SC/SC，1 m</td>
</tr>
<tr>
<td>NFK2-1SMPLX-LC</td>
<td>参考测试线，62.5/125 μm，SC/LC，1 m</td>
</tr>
<tr>
<td>NFK1-1SMPLX-ST</td>
<td>参考测试线，62.5/125 μm，SC/ST，1 m</td>
</tr>
<tr>
<td>NFK2-1SMPLX-SC</td>
<td>参考测试线，50/125 μm，SC/SC，1 m</td>
</tr>
<tr>
<td>NFK2-1SMPLX-LC</td>
<td>参考测试线，50/125 μm，SC/LC，1 m</td>
</tr>
<tr>
<td>NFK2-1SMPLX-ST</td>
<td>参考测试线，50/125 μm，SC/ST，1 m</td>
</tr>
<tr>
<td>NF300SM</td>
<td>ST/ST 光纤适配器</td>
</tr>
<tr>
<td>NF-OPRT-SC</td>
<td>可互换的 SC Fiber QuickMap 替换端口</td>
</tr>
</tbody>
</table>
<div>零配件</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>NFK1-LAUNCH</td>
<td>NFK1-LAUNCH，发射电缆套件，SC/SC，62.5UM</td>
</tr>
<tr>
<td>NFK1-LAUNCH-FC</td>
<td>NFK1-LAUNCH-FC，发射电缆套件，SC/FC，62.5UM</td>
</tr>
<tr>
<td>NFK1-LAUNCH-LC</td>
<td>NFK1-LAUNCH-LC，发射电缆套件，SC/LC，62.5UM</td>
</tr>
<tr>
<td>NFK1-LAUNCH-ST</td>
<td>NFK1-LAUNCH-ST，发射电缆套件，SC/ST，62.5UM</td>
</tr>
<tr>
<td>NFK2-LAUNCH</td>
<td>NFK2-LAUNCH，发射电缆套件，SC/SC，50UM</td>
</tr>
<tr>
<td>NFK2-LAUNCH-FC</td>
<td>NFK2-LAUNCH-FC，发射电缆套件，SC/FC，50UM</td>
</tr>
<tr>
<td>NFK2-LAUNCH-LC</td>
<td>NFK2-LAUNCH-LC，发射电缆套件，SC/LC，50UM</td>
</tr>
<tr>
<td>NFK2-LAUNCH-ST</td>
<td>NFK2-LAUNCH-ST，发射电缆套件，SC/ST，50UM</td>
</tr>
<tr>
<td>NFK2-LAUNCH-E2K</td>
<td>NFK2-LAUNCH-E2K，发射电缆套件，SC/E2K，50UM</td>
</tr>
</tbody>
</table>
</div>
<div id="box_specifications">
<h4>FLUKE Fiber QuickMap 多模光纤一键故障诊断一键测试规格</h4>
<table id="SpecTable1" border="0" cellspacing="0">
<tbody>
<tr>
<td colspan="2"><strong>型号</strong></td>
</tr>
<tr>
<td>带电池的工作<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span></td>
<td>0?C 至 50?C</td>
</tr>
<tr>
<td>非操作温度</td>
<td>-20?C 至 60?C</td>
</tr>
<tr>
<td>工作相对温度（无冷凝）</td>
<td>95% (10?C &#8211; 35?C) 75% (35?C &#8211; 40?C) 不受控制 &lt; 10?C</td>
</tr>
<tr>
<td>振动</td>
<td>任意，5 Hz 至 500 Hz，MIL-PRF- 28800F 类 2</td>
</tr>
<tr>
<td>冲击</td>
<td>1m 跌落试验</td>
</tr>
<tr>
<td>海拔</td>
<td>3000m</td>
</tr>
<tr>
<td>EMC</td>
<td>EN 61326-1：2004</td>
</tr>
<tr>
<td>电池类型</td>
<td>2 AA 碱性电池（无电池充电器）</td>
</tr>
<tr>
<td>电池寿命</td>
<td>1500 测试（典型）</td>
</tr>
<tr>
<td>激光安全性</td>
<td>1 类 CDRH 符合 EN 60825-2</td>
</tr>
<tr>
<td>LCD 类型</td>
<td>背光黑白（段）</td>
</tr>
<tr>
<td>折射率范围</td>
<td>1.45 至 1.5（出厂默认是 1.496）</td>
</tr>
<tr>
<td>自动关闭</td>
<td>若没有按键，则 5 min 后会自动关闭。背照灯首先关闭。</td>
</tr>
<tr>
<td>出厂<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>间隔</td>
<td>无</td>
</tr>
<tr>
<td>输出波长</td>
<td>850 nm ± 10 nm</td>
</tr>
<tr>
<td>激光类别</td>
<td>1 类 CDRH 符合 EN 60825-2</td>
</tr>
<tr>
<td>动态范围</td>
<td>&gt;11 dB</td>
</tr>
<tr>
<td>最大距离</td>
<td>1500 m 或 4921 ft</td>
</tr>
<tr>
<td>显示最大事件数量</td>
<td>9</td>
</tr>
<tr>
<td>距离精度（0 m 至 1500 m 或 0 ft 至 4921 ft）</td>
<td>±（1 m + 0.1 % x 长）对于反射事件<sup>1</sup> ±（3 m + 0.1 % x 长）对于非反射事件<sup>2</sup></td>
</tr>
<tr>
<td>测试速度</td>
<td>一般 &lt; 6 s</td>
</tr>
<tr>
<td>连接器</td>
<td>可拆卸/易清洁的 SC 适配器, UPC 打磨剂</td>
</tr>
<tr>
<td>测试光缆类型</td>
<td>50/125 ?m 或 62.5/125 ?m 多模</td>
</tr>
<tr>
<td>检测反射事件<sup>3</sup></td>
<td>-35 dB 默认阈值（用户可选：-20 dB 至 -45 dB 5 dB 增量）</td>
</tr>
<tr>
<td>反射精度<sup>4</sup></td>
<td>-4 dB</td>
</tr>
<tr>
<td>最大反射测量</td>
<td>-20 dB</td>
</tr>
<tr>
<td>检测损失事件<sup>5</sup></td>
<td>0.70 dB 默认阈值（用户可配置从 0.5 dB 至 6.1 dB 0.2 dB 增量）</td>
</tr>
<tr>
<td>隔板质量</td>
<td>若无已连接的光纤或连接器太脏，则故障诊断器将显示 0 m 或 0 ft。</td>
</tr>
<tr>
<td>检测带电光缆</td>
<td>检测从 600 nm 至 1050 nm 的光信号，若有信号则显示“有效线路”。第一次检测后每隔 3 秒检查一次信号。+7 dB 最大输入功率。</td>
</tr>
<tr>
<td>认证</td>
<td><img src="http://myaccount.flukenetworks.com/NR/rdonlyres/9E6D6663-A67E-4EB7-8604-E6E0CAE221E5/0/CE.jpg" border="0" alt="" /> 符合相关欧盟<br />
指令<br />
<img src="http://myaccount.flukenetworks.com/NR/rdonlyres/4A94F766-77FE-4AEB-B8D5-7207997B80C0/0/35x35_Australian_Gray.jpg" border="0" alt="" /> 符合相关澳大利亚标准<br />
<img src="http://myaccount.flukenetworks.com/NR/rdonlyres/F8C356F7-B22D-4D08-B1F2-593EFD84FC50/0/35x35_Canadian.jpg" border="0" alt="" /> 通过加拿大标准协会 CSA 认证<br />
C22.2 No. 61010.1.04<br />
<img src="http://myaccount.flukenetworks.com/NR/rdonlyres/C8DCBDDD-DA1E-49C4-8EA1-50865F87977B/0/FC_symbol.jpg" border="0" alt="" /> 符合 FCC 规定第 A 部分 A 类的规定</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table id="SpecTable1">
<tbody>
<tr>
<td colspan="2">1.± 用户可配置的折射率 (IOR) 误差 ± 事件位置错误。反射事件的事件位置错误：±1 m 从 1 m 至 1.5 km。</td>
</tr>
<tr>
<td colspan="2">2.± 用户可配置的折射率 (IOR) 误差 ± 事件位置错误。非反射事件的事件位置错误：±2 m（对于长度 ?15 m），其他 ±1 m。</td>
</tr>
<tr>
<td colspan="2">3.查找并给出反射率大于 -55 dB 的事件位置。隔板反射率 &lt; 35 dB 时检测隔板连接器后 &gt;1m 的事件。事件反射率 &lt; 35 dB 时检测事件后 &gt;3 m 的事件。</td>
</tr>
<tr>
<td colspan="2">4.反射散射系数 -63 dB @ 850 nm，使用校准的 -14 dB 参考。</td>
</tr>
<tr>
<td colspan="2">5.隔板反射率 &lt;-35 dB 且之前的事件 &lt;-35 dB 时，检测隔板连接器或任何之前事件之后 &gt;10 m 的事件。事件之前最大的链路损失 &lt;7 dB。</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
</div>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/fluke-fiber-quickmap.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>