<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; 布线测试</title>
	<atom:link href="http://www.faxytech.com/tag/%e5%b8%83%e7%ba%bf%e6%b5%8b%e8%af%95/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>超六类安装完成测试如何验收？</title>
		<link>http://www.faxytech.com/archives/cat6a.html</link>
		<comments>http://www.faxytech.com/archives/cat6a.html#comments</comments>
		<pubDate>Mon, 12 Dec 2016 01:26:26 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[布线测试]]></category>
		<category><![CDATA[超五类测试]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8371</guid>
		<description><![CDATA[A.超六类网线安装测试一般要求 1、应对安装中的每条电缆链路执行以下测试： a.接线图 b.长度 c.插入损耗 d.NEXT损耗 e.PS NEXT损耗 f.ACR-N损耗 g.ACR-F损耗 h.PS ACR-F损耗 i.回波损耗 j.传输延迟 k.延迟... ]]></description>
			<content:encoded><![CDATA[<h4>A.超六类网线安装测试一般要求</h4>
<p>1、应对安装中的每条电缆链路执行以下测试：</p>
<p>a.接线图</p>
<p>b.长度</p>
<p>c.<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span></p>
<p>d.<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>损耗</p>
<p>e.PS NEXT损耗</p>
<p>f.<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span>损耗</p>
<p>g.<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>损耗</p>
<p>h.PS ACR-F损耗</p>
<p>i.<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span></p>
<p>j.传输延迟</p>
<p>k.延迟偏差</p>
<p>l.直流(d.c.)环路电阻</p>
<p>m.直流(d.c.)电阻不平衡</p>
<p>n.屏蔽层连通性(如有)</p>
<p>o.横向转换损耗(TCL)</p>
<p>p.等电平横向转换转移损耗(ELTCTL)</p>
<p>遵循以下标准规定的现场测试规范：</p>
<ul>
<li><em>ISO/IEC 11801(2002)</em><em>：信息技术</em><em>– </em><em>用户建筑群普通电缆线路</em></li>
<li><em>ISO/IEC 11801</em><em>：信息技术</em><em>– </em><em>用户建筑群普通电缆线路 修正</em><em>1</em></li>
<li><em>ISO/IEC 11801</em><em>：信息技术</em><em>– </em><em>用户建筑群普通电缆线路 修正</em><em>2</em></li>
<li><em>IEC 61935-1 ed 4.0</em><em>：</em><em>ISO/IEC 11801</em><em>标准规定的平衡通信电缆的测试 </em><em>第</em><em>1</em><em>部分：已安装电缆</em>
<p>这些标准被统称为“ISO E<sub>A</sub>类标准”</li>
</ul>
<p>本文档使用的术语由以下标准定义或与其一致：</p>
<ul>
<li>“<em>ISO/IEC 14763-2</em><em>：信息技术 </em><em>— </em><em>用户建筑群布线的实施和操作 </em><em>- </em><em>第</em><em>2</em><em>部分：规划与安装</em></li>
</ul>
<p>2.对于已安装的双绞线水平链路，应从电信机房的IDF到工作区的墙式电信插座之间进行测试，以便符合ISO E<strong><sub>A</sub></strong>类标准中规定的“<em>永久链路</em>”性能。</p>
<p>3.百分之百的已安装电缆链路必须满足以上A.1中所述标准的要求，这些要求的详细内容请参见章节B。如有任何链路未能通过测试，必须对其进行诊断和修正。采取修正措施之后，必须重新进行测试，以证明修正后的链路满足性能要求。所有链路的最终测试结果和合格结果必须按照以下章节C的规定列在测试结果文件中。</p>
<p>4.负责执行测试的技术人员应参加过相应培训计划并获得证书。相应的培训计划包括但不仅限于BiCSi、ACP (电缆专家协会)或福禄克网络的<span class='wp_keywordlink'><a href="http://www.faxytech.com/edu" title="CCTT培训">CCTT</a></span> (<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%b8%83%e7%ba%bf%e6%b5%8b%e8%af%95" title="查看 布线测试 的全部文章" target="_blank">布线测试</a></span>认证工程师)培训伙伴提供的安装认证计划。</p>
<p>5.测试设备(测试仪)应满足标准IEC 61935-1：“<em>平衡和同轴信息技术布线测试的技术规范</em><em>– </em><em>第</em><em>1</em><em>部分：</em><em>ISO/IEC</em><em>标准规定的平衡布线 </em>”中规定的IIIe级现场测试仪精度要求。</p>
<p>注：如同一标准所述，符合IV级和/或V级要求与E<strong><sub>A</sub></strong>类设施的测试没有任何关联。</p>
<p>6.包含相应接口适配器的测试仪必须满足规定的精度要求。永久链路测试配置的精度要求(基本精度<em>加</em>适配器的影响)参见标准<em>IEC 61935-1</em><em>的表</em><em>14 – IEC</em><em>指导规定的</em><em>IIIE</em><em>级现场测试仪精度性能参数。</em></p>
<p><em>7.</em>永久链路适配器加NEXT/FEXT损耗应介于测试插头的下限和上限之间，符合标准IEC 60512-27-100 Ed 1.0：“电气设备连接器 &#8211; 测试和测量 &#8211; 第27-100部分：60603-7系列连接器500 Mhz以下信号完整度测试 &#8211; 测试27a至27g”对6A类的要求。此类测试插头通常被称为“真正同心的测试插头”。理想的测试插头与附录A.4“基于PCB的1 TFC总成”中所示的PCB式的版本完全相同。</p>
<p>8.为了达到厂商规定的测量精度，测试仪应在厂商推荐的<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>周期之内进行校准。</p>
<p>9.测试仪接口适配器必须具有高质量，测试仪接口适配器的盘绕和储存都不应造成电缆扭曲或缠绕。为了实现最佳精度，规定了测试仪的永久链路接口适配器的性能，可将其进行校准，将回波损耗测量的参考面扩展到永久链路接口。承包人应该证明已经在厂商建议的周期内对接口进行了校准。为确保工作中的正常操作不会造成可测量的回波损耗发生变化，适配器电缆不应采用双绞线结构。</p>
<p>10.被测链路的合格或不合格条件取决于要求的单项测试的结果(详细信息见表1“已安装平衡布线测试参数”的“内部传输”部分)。任何标注为“不合格”或“不合格*”的结果都造成被测链路测试“不合格”。只有每项测试参数均为“合格”或“合格<strong>*</strong>”时，整体结果才为“合格”。</p>
<p>11.每个参数的合格或不合格结果都通过将实测值与该参数的规定测试限值进行比较确定。如果测试结果与测试限值的相近程度超过现场测试仪的精度指标，则该参数的测试结果应用星号(*)标注。如果认为测试仪的精度优于IIIe级精度(ISO/IEC 619351-1：表9 &#8211; IIIE级测试仪器的最差条件插入损耗、NEXT、ACR-N、ELFEXT/ACR-F和回波损耗测量精度/永久链路限值处的链路精度)并用于判断裕量结果，测试仪制造商必须提供来自于独立实验室的“最差条件”测试数据，以支持这一观点。何种程度的“*”结果影响被测元件的批准或否决应在相应详细规范中定义，或者作为合同规范的一部分商定。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h4>B.<span style="font-size: 1em;">超六类网线安装<strong>测试</strong></span><strong>性能测试参数</strong></h4>
<p><strong>1.EA类的测试参数在标准ISO/IEC 11801：</strong>信息技术 – 客户建筑群普通电缆线路的修订2中定义。每条链路的测试应包含以下所有参数，详情见下文。为了通过测试，所有测量值(从1 MHz至500 MHz范围的每种频率下)都必须满足或超过以上所述标准规定的限值。频率步长应不超过0.5 Mhz (100 MHz以下时)和5 Mhz (500 MHz以下时)。</p>
<p><strong>2.接线图</strong><br />
如果每对线对的端对端连接是正确的，则应记录为合格。接线图结果应包括屏蔽层的连通性(如有)。</p>
<p><strong>3.插入损耗(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>)</strong><br />
插入损耗是衡量永久链路或通道中信号损耗的一项指标。术语“衰减”过去曾经用于表示“插入损耗”。应在1 MHz至500 MHz范围内测试插入损耗，最大步长为1 MHz。为了提高计算衰减串扰比(ACR)参数的精度，测量插入损耗时的频率间隔最好与NEXT损耗相同。最小测试结果存档(汇总结果)：判断最差线对(4种可能中的1种)。最差线对的测试结果必须显示实测的最高衰减值(最差条件)、最差条件值发生时的频率以及该频率下的测试限值。</p>
<p><strong>4.NEXT损耗</strong><br />
应在链路的每一段、对每一种线对组合(总共12种线对组合)进行线对之间的<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>损耗(缩写为NEXT损耗)测试。在1至500 MHz范围内测量该参数。NEXT损耗测量干扰线对发射端(近端)对另一线对的串扰。最小测试结果存档(汇总结果)：判断NEXT裕量最差(2)的线对组合和 NEXT值最差(最差条件)的线对组合。在被测链路的每一端测量NEXT。必须根据每一端的测试判断这些线对组合。报告的每种情况应该包括发生时的频率以及该频率下的测试限值。</p>
<p><strong>5.PS NEXT损耗</strong><br />
应该评估和报告被测链路两端的每个线对的测试结果(共8个测试结果)。PS NEXT损耗表示其他线对实际传输信号时对该线对的组合近端串扰影响(统计)。与NEXT一样，必须在1至500 MHz范围内对该测试参数进行评估：判断裕量最差的线对和PS NEXT值最差的线对。必须根据每一端的测试判断这些线对。报告的每种情况应该包括发生时的频率以及该频率下的测试限值。</p>
<p><strong>6.ACR-N，线对到线对</strong><br />
近端衰减串扰比是根据线对到线对的NEXT损耗和插入损耗计算得到的。应该在被测链路的每一端对每种线对组合进行测量。ACR-N测量近端串扰相对于到达链路起点的被衰减信号的相对强度。在1至500 MHz范围内测量ACR-N。最小测试结果存档(汇总结果)：判断裕量最差的线对组合以及ACR-N值最差的线对组合。必须根据每一端的测试判断这些线对。报告的每种情况应该包括发生时的频率以及该频率下的测试限值。</p>
<p><strong>7.PS ACR-N，线对到线对</strong><br />
近端功率和衰减串扰比是计算得到的参数，表示其中三个线对对第四个线对的NEXT影响。应该在被测链路的每一端对每种线对组合进行测量。PS ACR-N测量全部近端串扰的功率和相对于到达链路起点的被衰减信号的相对强度。在1至500 MHz范围内测量PS ACR-N。最小测试结果存档(汇总结果)：判断裕量最差的线对组合以及PS ACR-N值最差的线对组合。必须根据每一端的测试判断这些线对。报告的每种情况应该包括发生时的频率以及该频率下的测试限值。</p>
<p><strong>8.ACR-F，线对到线对</strong><br />
远端衰减串扰比是根据线对到线对的FEXT损耗计算得到的。应该在被测链路的每一端对每种线对组合进行测量。FEXT损耗测量干扰线对发射端外的另一端(远端)对另一线对的串扰。通过测量FEXT，计算得到ACR-F损耗，必须进行评估并在测试结果中报告。ACR-F测量远端串扰相对于到达链路末端的被衰减信号的相对强度。该项测试一般有24种线对组合。在1至500 MHz范围内测量ACR-F。最小测试结果存档(汇总结果)：判断裕量最差的线对组合以及ACR-F值最差的线对组合。必须根据每一端的测试判断这些线对。报告的每种情况应该包括发生时的频率以及该频率下的测试限值。</p>
<p><strong>9.PS ACR-F损耗</strong><br />
远端功率和衰减串扰比是计算得到的参数，表示其中三个线对对第四个线对的FEXT影响。该项测试一般有8种线对组合。在1至500 MHz范围内对每个线对进行评估。最小测试结果存档(汇总结果)：必须根据每一端的测试判断最差组合的线对。报告的每种情况应该包括发生时的频率以及该频率下的测试限值。</p>
<p><strong>10.回波损耗</strong><br />
回波损耗(RL)表示每个线对上反射的总能量。在被测链路的每一端对每个线对执行回波损耗测量。也在1至500范围内测量该参数。最小测试结果存档(汇总结果)：判断裕量最差的线对和回波损耗值最差的线对。必须根据每一端的测试判断这些线对。报告的每种情况应该包括发生时的频率以及该频率下的测试限值。</p>
<p><strong>11.传输延迟</strong><br />
传输延迟指信号从链路的一端传输到另一端所需的时间。对四个线对中的每个线对执行该项测试。最小测试结果存档(汇总结果)：判断传输延迟最差的线对。报告应包括实测传输延迟值以及测试限值</p>
<p><strong>12.延迟偏差</strong><br />
该参数表示四个线对的传输延迟之间的差异。传输延迟最短的线对作为参考线对，其延迟偏差值为零。最小测试结果存档(汇总结果)：判断传输延迟最差的线对(传输延迟最大)。报告应包括实测延迟偏差值以及测试限值。</p>
<p><strong>13.直流(d.c.)环路电阻</strong><br />
该参数表示每个线对导线的总直流电阻。</p>
<p><strong>14.直流(d.c.)电阻不平衡 </strong><br />
该参数表示每个线对的每根导线的直流电阻和线对间的直流电阻之间的差异，以确定已安装链路是否支持PoE (以太网供电)。</p>
<p><strong>15.屏蔽层连通性</strong><br />
如果TR、CP或TO处的电缆和连接硬件之间的屏蔽层不连续，则应报告屏蔽层开路。此外，对于仅连接地线并严重影响TI表面传输<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>的现象，也应报告为屏蔽层开路。</p>
<p><strong>16.横向转换损耗(TCL)</strong><br />
近端不平衡衰减，通过计算布线系统中一个线对上差模功率与共模功率之比测得，系统中只注入差模功率。<br />
注：由于缺乏针对链路的限值，所以应采用通道的限值。与预期链路相比，该项要求可认为是宽松的。</p>
<p><strong>17.等电平横向转换转移损耗(ELTCTL) </strong><br />
远端不平衡衰减，通过计算布线系统中差模功率与共模功率之比测得，系统中只注入差模功率。该值为TCTL。从TCTL中减去被测通道/链路的插入损耗，即得到EL TCTL。根据实测差模和共模电压之比进行计算。<br />
注：由于缺乏针对链路的限值，所以应采用通道的限值。与预期链路相比，该项要求可认为是宽松的。</p>
<p>&nbsp;</p>
<h4>C.<span style="font-size: 1em;">超六类网线安装</span><span style="font-size: 1em;">测试结果文档编制</span></h4>
<p>&nbsp;</p>
<p>1.测试结果/测量值应传输至基于Windows?的数据库应用程序，支持对这些测试记录进行维护、检查和存档。必须保证在每项测试结束时将测量结果不加修改地传输到PC，也就是“和在测试仪中保存的一样”，并且随后也不能修改这些结果。</p>
<p>2.对于已完成的工作，应该以CD-ROM或DVD的形式储存和提供数据库，包括查看、检查以及打印任何测试报告选项所需的软件工具。</p>
<p>3.应提供纸质测试结果，其中列出测试的所有链路以及以下汇总信息：</p>
<p>a.链路标识，应与总体系统文件中定义的命名规则一致。</p>
<p>b.被测链路的总体合格/不合格评估结果，包括NEXT裕量(总体最差条件)。</p>
<p>c.测试仪存储器中保存数据时的日期和时间。</p>
<p>&nbsp;</p>
<p>4.以电子形式提供的一般信息，以及每条链路的测试结果信息：</p>
<p>a.最终用户规定的位置标识。</p>
<p>b.链路标识，应与总体系统文件中定义的命名规则一致。</p>
<p>c.被测链路的总体合格/不合格评估结果。</p>
<p>d.处理测试结果时依据的标准的名称。</p>
<p>e.电缆类型以及长度计算时使用的NVP值。</p>
<p>f.测试仪存储器中保存数据时的日期和时间。</p>
<p>g.测试仪的品牌、型号及序列号。</p>
<p>h.测试仪接口的标识。</p>
<p>i.测试仪的最后校准日期。</p>
<p>j.测试仪软件的版本以及测试仪中测试标准数据库的版本。</p>
<p>k.测试结果信息必须包含关于章节B中所列并在C5和C6中详细介绍的每个测试参数的信息。</p>
<p>&nbsp;</p>
<p>5.在链路(在通道)详细测试结果。以电子数据库形式提供的详细测试结果数据必须包含以下信息：</p>
<p>对于频率相关的每个测试参数，测试期间每一频率下的实测值。PC数据库程序必须能够处理储存的数据，以便显示和打印测量参数的彩色图形。PC软件还必须提供汇总的数字格式，其中以数字形式提供一些关键信息，请参照上文所述的每个测试参数的汇总结果规定(最小数字测试结果文件)。</p>
<p><strong>长度</strong><strong>：</strong>判断电气长度最短的线对，长度值四舍五入到0.1 m (1)。</p>
<p><strong>传输延迟：</strong>判断传输延迟最短的线对，以纳米(ns)为单位的测量值以及测试限值。</p>
<p><strong>延迟偏差：</strong>判断延迟偏差最大的线对，以纳米(ns)为单位的计算值以及测试限值。</p>
<p><strong>插入损耗(衰减)：</strong>按照章节B关于最差线对的介绍，存档最小测试结果。</p>
<p><strong>回波损耗：</strong>按照章节B关于最差线对的介绍，从链路的每一端进行测量，存档最小测试结果。</p>
<p><strong>NEXT、ACR-N、ACR-F、TCL和ELTCTL：</strong>按照章节B关于最差线对组合的介绍，从链路的每一端进行测量，存档最小测试结果。</p>
<p><strong>PS NEXT、PS ACRN和PS ACR-F：</strong>按照章节B关于最差线对的介绍，从链路的每一端进行测量，存档最小测试结果。</p>
<p>&nbsp;</p>
<p>1：额定传输速度(NVP)表示电信号在电缆链路中相对于真空中光速(3&#215;108 m/s)的速度。线对双绞线的绝缘特性对NVP的影响很小。通常情况下，用“平均”NVP值表示数据电缆中的全部四个线对。</p>
<p>2：“裕量”表示实测值与对应测试限值之差。对于通过测试的链路，“最差条件裕量”表示整个频率范围内最小的裕量；即实测性能“最接近”测试限值的点。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/cat6a.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DSX-5000,OFP-100-Q,CFP-100-Q成为2014数据中心布线利器</title>
		<link>http://www.faxytech.com/archives/2014-liqi.html</link>
		<comments>http://www.faxytech.com/archives/2014-liqi.html#comments</comments>
		<pubDate>Wed, 22 Jan 2014 01:01:12 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[新闻资讯]]></category>
		<category><![CDATA[CFP-100-Q]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[OFP-100-Q]]></category>
		<category><![CDATA[吴世军]]></category>
		<category><![CDATA[布线测试]]></category>
		<category><![CDATA[数据中心]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=3508</guid>
		<description><![CDATA[&#160; &#160; 2014数据中心布线测试利器福禄克网络（Fluke Networks）Versiv （DSX-5000,OFP-100-Q,CFP-100-Q)线缆认证分析仪。 &#160; &#160; 谈及数据中心，人们第一反应通常是服务器、存储、网络产品，随之而... ]]></description>
			<content:encoded><![CDATA[<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	&nbsp; &nbsp; 2014<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%95%b0%e6%8d%ae%e4%b8%ad%e5%bf%83" title="查看 数据中心 的全部文章" target="_blank">数据中心</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%b8%83%e7%ba%bf%e6%b5%8b%e8%af%95" title="查看 布线测试 的全部文章" target="_blank">布线测试</a></span>利器福禄克网络（<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span>）<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> （<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp-100-q.html" title="fluke OFP-100-Q">OFP-100-Q</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="福禄克Fluke CFP-100-Q">CFP-100-Q</a></span>)<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="线缆认证分析仪">线缆认证分析仪</a></span>。
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	&nbsp; &nbsp; 谈及数据中心，人们第一反应通常是服务器、存储、网络产品，随之而来则是相应的架构。而用来连接服务器、存储、网络产品之间的<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>或是光纤却很少被人所提及。殊不知，它们却是数据中心里最大的隐患。&ldquo;这也是最容易被人们忽视的地方，没有人详细的了解每一根线缆要经过什么样的测试。&rdquo;福禄克网络公司培训经理<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%90%b4%e4%b8%96%e5%86%9b" title="查看 吴世军 的全部文章" target="_blank">吴世军</a></span>对此说道。
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	　　&ldquo;交换机、服务器、存储设备之间可以看做是一个三角结构。根据数据结构的不同，对于光纤或是铜缆都有着不同的需求。&rdquo;对此，福禄克网络在北美地区的一份调查显示，在错误的标准选择下，100根线缆大约有7根线缆需要返工。返工将影响一个月45工时，对于项目承包商来说损失的不仅是返工的成本，同时也影响了用户的口碑。吴世军对此做了进一步的说明：测试的意义不在于网络的通或不通，而是能否真正达到设计的负载量。&ldquo;设计足够跑高清视频的带宽只用文本传输来测试，等到真正上了业务线缆问题就暴露无遗了。&rdquo;
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	<br />
	福禄克网络公司培训经理吴世军
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	　　在这一点上，福禄克网络将丰田公司的精益管理系统引入了新一代的Versiv布线认证产品系列中，有效的提升测试准确性。&ldquo;用户在测试之前就可以知悉如何设置标准、相应的参考值以及测试方法，这就避免在真正测试时候造成错误。&rdquo;吴世军强调，错误的测试结果往往会导致错误的验收结果。而现在，Versiv可以在测试前根据网络架构协助用户做好相应的准备：&ldquo;计划是第一步，要测多少根线，选择哪些操作员负责万兆的核心层测试、哪些操作员负责千兆的接入层测试;配置是第二步，核心层的测试光纤标准选择，接入层的测试铜缆标准选择，自动匹配相应参考值。&rdquo;
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	　　测试仪器的&ldquo;全面进化&rdquo;
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	　　以往，测试仪器就是测试仪器，携带笔记本电脑配合做好项目管理是必不可少的。&ldquo;测试人员每天也许要跑几个地点，而测试设备也许要经手几个人，如果不能在测试完成后立刻将数据导出，那么等待他们的通常就是未存数据被覆盖。&rdquo;而新一代Versiv在项目管理上的特性对于国内的多人、多项目共用一台设备的普遍现状来说不可谓不贴心。
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	　　&ldquo;现在的Versiv可以说是一体化结构，把一个项目分为七个流程，从开始的计划、设置、测试直到最后的报告生成，七步走全部由一台仪器完成。&rdquo;此外，吴世军表示客户对于新一代Versiv的最多反馈就是易用性提高了。&ldquo;以前的产品是拨表按键方式，十几个键需要手动去调整;现在的Versiv则是触摸屏搭配一键测试。&rdquo;新一代Versiv产品采用了模块化设计的方式，测试人员只需要携带一台设备及相应模块即可完成对铜缆、光纤、乃至无线网络的测试。
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	<img alt="福禄克Fluke Versiv" src="http://www.faxytech.com/wp-content/uploads/2013/06/Versiv1.jpg" />
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	　　面对新的标准和技术，福禄克网络还做出了哪些变化？&ldquo;随着带宽的变大，同样的线缆要跑上更高的速度，这也意味着更高的质量。对于我们的设备来说，在带宽和精度上都要跟上，我们已经从四级精度上升到五级精度了。&rdquo;据吴世军介绍，为保证集成商或施工方能更快的完成测试项目，福禄克网络还大大提高了测试速度。&ldquo;以前6A的线缆测试需要20秒钟，现在同样的测试只需要10秒钟。&rdquo;换句话说，完成同样的工作量，现在施工方只需要更少的员工;而触摸屏带来的更高易用性，也使得施工方不必花过多的时间用来做培训。这些因素都为施工方创造了更大的利润空间。
</p>
<p style="margin: 8px 0px; font-family: 宋体; font-size: 13px; line-height: 20px;">
	　　&ldquo;新产品比上一代产品有更高的购买价值。&rdquo;据吴世军介绍，Versiv的上一代产品是在2004年推出的，至今仍受到众多用户的。而更早的一代推出时间则是在1995年。&ldquo;第五代Versiv的生命周期也将有十年以上，其所见即所得的获取方式将在未来获得更广泛的认可。&rdquo;吴世军如是说。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/2014-liqi.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克网络布线测试新品“威测”(Versiv)震撼发布</title>
		<link>http://www.faxytech.com/archives/versiv-620.html</link>
		<comments>http://www.faxytech.com/archives/versiv-620.html#comments</comments>
		<pubDate>Thu, 20 Jun 2013 03:18:22 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[新闻资讯]]></category>
		<category><![CDATA[CertiFiber Pro]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[Versiv]]></category>
		<category><![CDATA[威测]]></category>
		<category><![CDATA[布线测试]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[福禄克网络]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=3020</guid>
		<description><![CDATA[深圳 ?中国 2013年6月20日 福禄克网络布线测试新品“威测”(Versiv)震撼发布 亲爱的福禄克网络客户朋友，作为福禄克代理商，我们诚挚的邀请您关注福禄克网络最新发布的布线测试平台——威测... ]]></description>
			<content:encoded><![CDATA[<p>深圳 ?中国 2013年6月20日</p>
<p><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>网络<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%b8%83%e7%ba%bf%e6%b5%8b%e8%af%95" title="查看 布线测试 的全部文章" target="_blank">布线测试</a></span>新品“<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-versiv.html" title="威测">威测</a></span>”(<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span>)震撼发布</p>
<p>亲爱的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b%e7%bd%91%e7%bb%9c" title="查看 福禄克网络 的全部文章" target="_blank">福禄克网络</a></span>客户朋友，作为福禄克代理商，我们诚挚的邀请您关注福禄克网络最新发布的布线测试平台——<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%a8%81%e6%b5%8b" title="查看 威测 的全部文章" target="_blank">威测</a></span>(<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/versiv" title="查看 Versiv 的全部文章" target="_blank">Versiv</a></span>)。威测是一款很强大的平台化产品，包含多个可更换的模块，支持<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>、光纤以及光时域反射(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>)的测试；同时，创新的软件也提高了测试的速度与精度，并简化了测试设置，规划以及出报告的流程。这款模块化的测试平台绝对是布线测试的不二之选！威测(Versiv)家族提升了线缆验证中每一步的速度。前瞻性的设计支持铜缆验证，光纤损耗以及OTDR测试以及硬件平台的升级。开创性的ProjX管理系统以及触摸式交互界面保证了工作既快又好的完成。使用<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>管理软件对测试结果进行分析并生成专业的测试报告。</p>
<p><img src="http://dsx5000.faxytech.com/wp-content/uploads/2013/06/versiv1.png" alt="福禄克Versiv" /></p>
<p>左：福禄克中国区总经理刘强?????? 右：福禄克渠道培训经理吴世军</p>
<p>威测(Versiv)家族包括:</p>
<p>1、创新的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span><span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="线缆分析仪">线缆分析仪</a></span>:——最先进的铜缆认证测试仪<br />
2、最新的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> Pro?OLTS测试仪——快而简便的光纤认证测试<br />
3、用企业定制的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/optifiber-otdr.html" title="福禄克Fluke OptiFiber">OptiFiber</a></span>?Pro?OTDR?——提供了革新的光纤故障和认证测试<br />
4、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/onetouch-at.html" title="OneTouch">OneTouch</a></span>?AT?Network?Assistant——一客户端至“云”端的一键式网络性能故障诊断设备<br />
在一项针对全球布线专业人士的调研发现：误操作，布线复杂性以及返工导致平均每1000根线缆的安装就需要增加1周的工作量。威测(Versiv:trademark:)正是为了应对这些日益凸显的挑战而产生的。它超越了测试和故障诊断本身，更强调整个线缆认证的生命周期。它的全新功能帮助布线集成商管理今天线缆认证的复杂性，减少误操作。<br />
☆您是否了解测试错误可导致每年3万美金的损失？<br />
☆您是否知道90%的项目经理会认为测试错误令他们损失利润？</p>
<p><img src="http://www.faxytech.com/wp-content/uploads/2013/06/Versiv1.jpg" alt="福禄克Fluke Versiv" /></p>
<p>威测(Versiv)的新特性:<br />
1、ProjX管理系统<br />
2、简便以及高效的设置、同时管理多个测试任<br />
3、支持100个项目以及存储超过12000个图形化的测试结果<br />
4、触摸式：触控式的交互界面简化了测试的设置，去除了错误及加快了故障诊断</p>
<p>LinkWare:管理软件：管理一个测试工程中的所有结果，创建综合性的报告?模块化设计<br />
<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-5000" title="查看 DSX-5000 的全部文章" target="_blank">DSX-5000</a></span>:双绞线铜缆认证<br />
CertiFiber?Pro:光纤损耗测试<br />
OptiFiber?Pro:光纤OTDR故障诊断及认证<br />
OneTouch?AT:无线及有线网络分析<br />
DSX线缆分析仪可测试和验证双绞线Cat5e，6，6A及FA。</p>
<p>采用触摸式人机交互，ProjX系统及LinkWare软件使验证更快捷。</p>
<p>CertiFiber?Pro?OLTS是一个<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>，3秒完成双波长双光纤测试。采用触摸式人机交互，ProjX系统及LinkWare软件使验证更快捷。</p>
<p>福禄克网络（<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fluke" title="查看 Fluke 的全部文章" target="_blank">Fluke</a></span> Network）专业发展历程：</p>
<p>众所周知福禄克网络一直以来非常地专注网络测试方案，因为专注所以Fluke ?Networks非常的专业。在专业的前提下福禄克网络不断地创新，推出新的产品。事实上福禄克网络是在线缆测试和网络测试业界公认的领导者，1995年福禄克网络推出了<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsp-4000series.html" title="福禄克FLuke DSP">DSP</a></span>线缆测试仪，在当时也是非常震撼的一款产品，可以说直到20年后的今天仍然有用户在使用，尽管福禄克网络之后又发展了新的产品。2004年福禄克网络推出了<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>系列的线缆测试仪产品，今天福禄克网络在线缆测试仪领域又推出了“威测”系列。大家可以看到，福禄克网络这种重磅的线缆测试产品都差不多是9年的时间间隔，所以我们说十年磨一剑。同时了解福禄克网络的人可能更多地知道福禄克网络是一个专业领先的线缆和网络测试设备的厂家，事实上早在2003年福禄克网络就已开始进入了无线测试的领域。2003年，专业的AirMagnet产品就已推出，而在2007年，通过<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ntm.html" title="福禄克FLuke NTM">NTM</a></span>网络海量存储<a href="http://www.search.hc360.com/cgi-bin/seinterface.cgi?word=%B7%D6%CE%F6%D2%C7" target="_blank">分析仪</a>，福禄克网络又进入了网络性能管理和应用性能管理的领域。在今年的2月份福禄克网络又推出了一体化的网络分析和性能分析产品<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/truview.html" title="福禄克Fluke TruView">TruView</a></span>。所以今天的福禄克网络一方面在线缆测试、网络测试、手持工具这样的设备上不断创新推出新的产品，同时在网络性能管理、应用性能管理方向上不断的创新，也推出很多新的解决方案。</p>
<p>更多信息请访问www.faxytech.com</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/versiv-620.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>布线工艺要求-通过布线认证测试的基础</title>
		<link>http://www.faxytech.com/archives/buxian-gongyi.html</link>
		<comments>http://www.faxytech.com/archives/buxian-gongyi.html#comments</comments>
		<pubDate>Thu, 02 Dec 2010 02:35:57 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[布线工艺]]></category>
		<category><![CDATA[布线注意要点]]></category>
		<category><![CDATA[布线测试]]></category>
		<category><![CDATA[布线要求]]></category>
		<category><![CDATA[布线认证测试]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=265</guid>
		<description><![CDATA[布线工程的质量大多数情况下是要靠现场的施工工艺来保证的，一个布线工程能否顺利通过验收测试，很大程度上要取决于布线中的工艺水平。这里针对布线中的几个方面，简单介绍一下布线... ]]></description>
			<content:encoded><![CDATA[<p>布线工程的质量大多数情况下是要靠现场的施工工艺来保证的，一个布线工程能否顺利通过验收测试，很大程度上要取决于布线中的工艺水平。这里针对布线中的几个方面，简单介绍一下布线施工的工艺要求。</p>
<p>水平电缆敷设</p>
<ul>
<li>在敷设之前，先检查所有管槽是否已经完成并符合要求，路由及拟安装信<br />
息口的位置是否与设计相符；</li>
<li>核对电缆的规格和型号；</li>
<li>在管里穿线时，要避免电缆受到过度拉引，每米的拉力不能超过 7 公斤，<br />
必要时可在管内加少量滑石粉以减少线揽与管内壁之间的磨察；</li>
<li>水平线槽中敷设电缆时，电缆应顺直，尽量避免交叉；</li>
<li>布线事不能伤保护套和踩踏线缆；</li>
<li>水平线缆在信息输出口处预留 30-50cm ；</li>
<li>水平线缆敷设时，两端应做好标签，填好放线记录表；</li>
<li>对于有安装天花的区域，所有的水平线缆敷设工作最好在天花施工前完成；</li>
<li>所有线缆不应外露。</li>
</ul>
<p>垂直主干敷设</p>
<ul>
<li>垂直主干敷设时一定要避免因电缆自重使电缆受到过大的拉力；</li>
<li>垂直主干自上而下敷设时，每隔三层须将电缆全部抽回楼面，绑扎好上面<br />
的电缆后再向下敷设；</li>
<li>垂直线槽中敷设主干电缆时，每隔 1.5-2 米应绑扎固定，水平电缆在垂直<br />
线槽中敷设时应每 20 根绑扎一捆，然后每隔 1.5-2 米进行绑扎固定。</li>
<li>主干电缆弯曲半径为电缆外径的 10 倍，在线槽中排布整齐，电缆在绑扎时<br />
松紧适度，不可绑扎得过紧；</li>
<li>垂直主干在两端预留 5-6 米；</li>
<li>敷设垂直主干时应做好标签，并填好放线记录；</li>
<li>所有线缆不应外露。</li>
</ul>
<p>光缆敷设</p>
<ul>
<li>光缆的弯曲半径应至少为光缆外径的 15 倍，在施工过程中应至少于 20 倍；</li>
<li>布放光缆时，光缆盘转动应与布放速度同步，光缆索引的速度一般每分 15 米；</li>
<li>布放光缆时，光缆出盘处要保持松弛的弧度，并保留缓冲的余量，又不宜过多，避免光缆出现背扣；</li>
<li>光缆在两端预留长度为 5-10 米；</li>
<li>敷设光缆时应做好标签，并填好放线记录；</li>
<li>所有光缆不应外露。</li>
</ul>
<p>配线架安装及端接</p>
<ul>
<li>分配线架挂墙安装时，下端应高于 0.3 米，上端应低于 2 米；</li>
<li>配线架挂墙安装时应保证垂直，垂直偏差度不得大于 3mm ；</li>
<li>分配线间配线架采用壁挂式机柜包装；机柜垂直倾斜误差不应大于 3 mm ，<br />
底座水平误差每平方米不大应于 2mm;</li>
<li>系统端接前应确认电缆和光缆敷设已经完成，配线间土建及装修工程完工完成，具有洁净的环境和良好的照明条件，配线架已安装好，核对电缆编号无误；</li>
<li>剥除电缆护套时应采用专用电缆开线器，不得刮伤绝缘层，电缆中间不得产生断接现象；</li>
<li>端接前须准备好配线架端接表，电缆端接依照端接表进行。</li>
</ul>
<p>信息插座安装</p>
<p>?? 信息插座安装前必须确认所有装修工作完成，核对信息口编号是否有误；所有信息插座按标准进行卡接；</p>
<p>?? 信息插座安装在墙体上时，宜高出地面 30cm;</p>
<p>?? 信息插座安装完毕后应立即依照平面图在面板上做好编号。</p>