<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; elfext</title>
	<atom:link href="http://www.faxytech.com/tag/elfext/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>ACR-F，正式名称为等电平远端串音 (ELFEXT) 英文版</title>
		<link>http://www.faxytech.com/archives/acr-f-elfext.html</link>
		<comments>http://www.faxytech.com/archives/acr-f-elfext.html#comments</comments>
		<pubDate>Thu, 04 Jan 2018 08:31:33 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[ACR-F]]></category>
		<category><![CDATA[elfext]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=9575</guid>
		<description><![CDATA[In June 2008, Fluke Networks adopted the new nomenclature ACR-F as defined in ANSI/TIA-568-C.2 as well as various European and International Standards. ACR-F is an acronym for Attenuation Crosstalk Ratio Far-end. ACR-F is a calculated result, rather than... ]]></description>
			<content:encoded><![CDATA[<p>In June 2008, <span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> adopted the new nomenclature <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span> as defined in ANSI/TIA-568-C.2 as well as various European and International Standards. <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-f" title="查看 ACR-F 的全部文章" target="_blank">ACR-F</a></span> is an acronym for <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="Attenuation">Attenuation</a></span> Crosstalk Ratio Far-end.</p>
<p>ACR-F is a calculated result, rather than a measurement. It is derived by subtracting the Insertion Loss of the disturbing pair from the Far End Crosstalk (FEXT) this pair induces in an adjacent pair. This normalizes the results for length. Consider the FEXT and attenuation measured on two links constructed of the same materials with the same workmanship, but different lengths.</p>
<p><strong>50 m link example:</strong></p>
<p>&nbsp;</p>
<blockquote dir="ltr">
<blockquote dir="ltr">
<blockquote dir="ltr"><p>FEXT = 45 dB<br />
Insertion Loss = 11 dB</p>
<p>ACR-F = 45 &#8211; 11 = 34 dB</p></blockquote>
</blockquote>
</blockquote>
<p>&nbsp;</p>
<p>Another way to understand ACR-F is to think of far-end Attenuation Crosstalk Ratio (ACR) as the same thing.</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2018/01/acr-f.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9576" title="acr-f" src="http://www.faxytech.com/wp-content/uploads/2018/01/acr-f.gif" alt="" width="400" height="114" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;<br />
<strong>Results Interpretation</strong><br />
Compare the results of measurements made from both ends of the link to the appropriate ISO or TIA limits. There are 12 ACR-F measurements made from each end, for a total of 24. This is because the Insertion Loss can vary slightly depending upon which pair is energized. So as an example, the field tester will energize Pair 1 and listen on Pair 2 at the far end. Then it will energize Pair 2 and listen on Pair 1 at the far end.</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2018/01/acr-f-r.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9577" title="acr-f-r" src="http://www.faxytech.com/wp-content/uploads/2018/01/acr-f-r.gif" alt="" width="532" height="324" /></a><br />
ACR-F that is too high is indicative of either excessive Insertion Loss, higher than expected FEXT, or both.</p>
<p><strong>Troubleshooting Recommendations</strong><br />
Experience has shown us that ACR-F issues are normally caused by a cable issue/fault.</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/acr-f-elfext.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克网络：ACR-F取代ELFEXT</title>
		<link>http://www.faxytech.com/archives/acr-replace-elfext.html</link>
		<comments>http://www.faxytech.com/archives/acr-replace-elfext.html#comments</comments>
		<pubDate>Wed, 04 Nov 2015 04:41:35 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[ACR-F]]></category>
		<category><![CDATA[elfext]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6959</guid>
		<description><![CDATA[2008年6月，福禄克网络在ANSI/TIA-568-C.2?中采用了与欧洲标准和国际标准一样的新参数ACR-F。ACR-F是一个叫做：衰减远端串扰比。 ACR-F是一个计算结果，而不是测量值。它是通过两条相邻线对减去远... ]]></description>
			<content:encoded><![CDATA[<p>2008<span style="font-family: 宋体;">年</span><span style="font-family: Arial;">6</span><span style="font-family: 宋体;">月</span>，福禄克网络在ANSI/TIA-568-C.2?中采用了与欧洲标准和国际标准一样的新参数<span style="font-family: Arial;"><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span></span><span style="font-family: 宋体;">。</span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-f" title="查看 ACR-F 的全部文章" target="_blank">ACR-F</a></span><span style="font-family: 宋体;">是一个</span>叫做：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>远端串扰比。</p>
<p>ACR-F<span style="font-family: 宋体;">是一个计算结果，而不是测量值。它是通过</span>两条相邻线对减去远端串扰（FEXT<span style="font-family: 宋体;">）衰减的信号得出的值。长度不一样结果也会不一样。使用同样材料和做工的两条链路衰减和</span><span style="font-family: Arial;">FEXT</span><span style="font-family: 宋体;">会不一样，因为长度不一样。</span></p>
<p><span style="font-family: 宋体;"><br />
</span></p>
<p>举个栗子：50M<span style="font-family: 宋体;">链路标准：</span></p>
<p><span style="color: #ff0000;"><strong>FEXT（远端串扰） =?45?dB </strong></span></p>
<p><span style="color: #ff0000;"><strong>Insertion?Loss(<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>） =?11?dB</strong></span></p>
<p><span style="color: #ff0000;"><strong>ACR-F （远端衰减串扰比)</strong></span><strong style="color: #ff0000;">=?45?-?11?=?34?dB</strong></p>
<p><strong style="color: #ff0000;"><br />
</strong></p>
<p>另外一种方法去理解ACR-F<span style="font-family: 宋体;">就是，认为是远端的</span><span style="font-family: Arial;">ACR-F</span><span style="font-family: 宋体;">。和下面的图片一样。</span></p>
<p><strong><a href="http://www.faxytech.com/wp-content/uploads/2015/11/fext.png" class="highslide-image" onclick="return hs.expand(this);"><img title="fext 远端串扰" src="http://www.faxytech.com/wp-content/uploads/2015/11/fext.png" alt="fext 远端串扰" width="400" height="114" /></a></strong></p>
<p>结论说明（用英文原文）<br />
Compare?the?results?of?measurements?made?from?both?ends?of?the?link?to?the?appropriate?ISO?or?TIA?limits.?There?are?12?ACR-F?measurements?made?from?each?end,?for?a?total?of?24.?This?is?because?the?Insertion?Loss?can?vary?slightly?depending?upon?which?pair?is?energized.?So?as?an?example,?the?field?tester?will?energize?Pair?1?and?listen?on?Pair?2?at?the?far?end.?Then?it?will?energize?Pair?2?and?listen?on?Pair?1?at?the?far?end.</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/11/acr-f1.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-6961" title="acr-f" src="http://www.faxytech.com/wp-content/uploads/2015/11/acr-f1.png" alt="acr-f" width="532" height="324" /></a></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2015/11/acr-f1.png" class="highslide-image" onclick="return hs.expand(this);"></a>ACR-F?that?is?too?high?is?indicative?of?either?excessive?Insertion?Loss,?higher?than?expected?FEXT,?or?both.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/acr-replace-elfext.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Fluke DTX-1800常见故障分析及解决方法</title>
		<link>http://www.faxytech.com/archives/faq-fail.html</link>
		<comments>http://www.faxytech.com/archives/faq-fail.html#comments</comments>
		<pubDate>Mon, 01 Dec 2014 13:12:56 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[elfext]]></category>
		<category><![CDATA[串扰]]></category>
		<category><![CDATA[常见故障]]></category>
		<category><![CDATA[开路]]></category>
		<category><![CDATA[等电平远端串扰]]></category>
		<category><![CDATA[线序]]></category>
		<category><![CDATA[衰减]]></category>
		<category><![CDATA[解决方法]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=5502</guid>
		<description><![CDATA[Fluke DTX-1800常见故障分析及解决方法由深圳市连讯达电子技术开发有限公司整理提供，深圳连讯有着17年福禄克测试行业经验领先优势，拥有大量技术尖兵，欢迎来电咨询探讨技术问题。如果需... ]]></description>
			<content:encoded><![CDATA[<p>Fluke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%b8%b8%e8%a7%81%e6%95%85%e9%9a%9c" title="查看 常见故障 的全部文章" target="_blank">常见故障</a></span>分析及<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%a7%a3%e5%86%b3%e6%96%b9%e6%b3%95" title="查看 解决方法 的全部文章" target="_blank">解决方法</a></span>由深圳市连讯达电子技术开发有限公司整理提供，深圳连讯有着17年福禄克测试行业经验领先优势，拥有大量技术尖兵，欢迎来电咨询探讨技术问题。如果需要购买Fluke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-1800可以直接拨打官方客服热线：400-688-2580</p>
<p>Fluke DTX-1800技术规格说明：</p>
<table id="SpecTable0" border="1" cellspacing="0" cellpadding="0" width="100%" bordercolor="#000000">
<tbody>
<tr>
<td valign="top"><strong>电缆类型 </strong><strong>标准的链路接口适配器</strong></td>
<td valign="top"><strong>LAN</strong><strong>网用屏蔽和非屏蔽双</strong><strong>绞线（STP</strong><strong>，FTP</strong><strong>，SSTP</strong><strong>和UTP</strong><strong>）：</strong>&nbsp;</p>
<ul>
<li>TIA 3类、4类、5类、超5类和6类：100Ω</li>
<li>ISO/IEC C 级和 D 级：100Ω和120Ω</li>
<li>ISO/ IEC E 级，100W ISO/ IEC F 级，100Ω</li>
<li>6类/E级 永久链路适配器插头类型和寿命：屏蔽和非屏蔽双绞线，TIA 3类、4类、5类、超5类和6类，以及ISO/IEC C级、D级和E级永久链路</li>
<li>6类/E级 通道适配器插头类型和寿命：屏蔽和非屏蔽双绞线，TIA 3类、4类、5类、超5类和6类，以及ISO/IEC C级、D级和E级通道</li>
</ul>
</td>
</tr>
<tr>
<td valign="top">
<div><strong>测试标<strong>准</strong></strong></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</td>
<td valign="top">
<ul>
<li>TIA/EIA-568B标准： 3类和超5类</li>
<li>TIA TSB-95标准：5类（1000BASE-T）</li>
<li>TIA/EIA-568B.2-1标准：6类（TIA/EIA-568B.2附录1）</li>
<li>ISO/IEC 11801标准：C级、D级和E级</li>
<li>ISO/IEC 11801标准：F级EN 50173标准：C级、D级和E级</li>
<li>EN 50173标准：F级ANSI TP-PMD</li>
<li>10BASE5，10BASE2，10BASE-T，100BASE-TX，1000BASE-T</li>
<li>IEEE 802.5 （屏蔽线，IBM 1型，150W）令牌环，4Mbps和16Mbps</li>
</ul>
</td>
</tr>
<tr>
<td valign="top"><strong>自</strong><strong>动测试速</strong><strong>度</strong></td>
<td valign="top">完整的双向6类双绞线链路自动测试时间：12秒或更少<br />
完整的双向 ISO/IEC F 级链路自动测试时间：32秒</td>
</tr>
<tr>
<td valign="top"><strong>支持的</strong><strong>测试参</strong><strong>数</strong></td>
<td valign="top">（测试参数及测试的频率范围由所选择的测试标准所决定）接线图、<br />
长度、<br />
传输时延、<br />
时延偏离、<br />
支流环路电阻、<br />
<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>）、<br />
<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>，远端回波损耗<br />
<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>、远端近端<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e4%b8%b2%e6%89%b0" title="查看 串扰 的全部文章" target="_blank">串扰</a></span><br />
<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%a1%b0%e5%87%8f" title="查看 衰减 的全部文章" target="_blank">衰减</a></span>串扰比，远端衰减串扰比<br />
综合等效远端串扰，远端综合等效远端串扰<br />
综合近端串扰，远端综合近端串扰<br />
综合衰减串扰比、远端综合衰减串扰比</td>
</tr>
</tbody>
</table>
<p>由上所知Fluke DTX-1800有着非常优势的技术，能满足各种国际和国内标准，支持多项参数测试。但是如果我们测试完成后，如何去发现这些参数是由于什么问题引起的呢？</p>
<p>第一点：<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%ba%bf%e5%ba%8f" title="查看 线序 的全部文章" target="_blank">线序</a></span>、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%bc%80%e8%b7%af" title="查看 开路 的全部文章" target="_blank">开路</a></span></p>
<p>? 导线在连接器或分线盒处接错针脚<br />
? 连接故障<br />
? 连接器已损坏<br />
? 电缆已损坏<br />
? 在设置中选择了错误的线对<br />
? 电缆应用错误</p>
<p>第二点：线序、 c<br />
导线在连接器或分线盒处接错针脚。</p>
<p>第三点：线序、 线对反接<br />
导线在连接器或分线盒处接错针脚。</p>
<p>第四点：线序、 线对跨接<br />
? 导线在连接器或分线盒处接错针脚。<br />
? 568A 和568B 接线标准混淆（12 和36 交叉）。<br />
? 在不需要的位置使用了交叉电缆（12 和36 交叉）。</p>
<p>第五点：线序、 短路<br />
? 连接器已损坏<br />
? 电缆已损坏<br />
? 导电性材料粘连在连接器的针脚之间<br />
? 连接器端接不当<br />
? 电缆应用错误</p>
<p>第六点：串扰和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%ad%89%e7%94%b5%e5%b9%b3%e8%bf%9c%e7%ab%af%e4%b8%b2%e6%89%b0" title="查看 等电平远端串扰 的全部文章" target="_blank">等电平远端串扰</a></span>（ELFEXT）故障<br />
? 连接器处线对过于松散<br />
? 跳线质量低劣<br />
? 连接器质量不佳<br />
? 电缆质量不佳<br />
? 电缆压紧（电缆分接头过紧、收缩、纽绞等）<br />
? 耦合器使用不当<br />
? 布线附近存在电气噪声源<br />
? 选择了错误应用</p>
<p>第七点：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>故障<br />
? 跳线或电缆阻抗不是100 ?（阻抗不匹配）<br />
? 跳线处理时引起阻抗变化<br />
? 插座盒内电缆数量过多<br />
? 配线盒内工作回路过密<br />
? 连接器处线对过于松散<br />
? 连接器质量不佳<br />
? 电缆阻抗不一致<br />
? 电缆压紧（电缆分接头过紧、收缩、纽绞等）<br />
? 插头和插孔匹配不良<br />
? 电缆包覆皮沾水<br />
? 选择了错误应用</p>
<p>第八点：介入损耗（衰减）故障<br />
? 布线过长<br />
? 跳线质量低劣<br />
? 连接不良<br />
? 安装的电缆类型错误<br />
? 选择了错误应用</p>
<p>如果您时间遇到了测试问题，可以像我们提交留言或者直接拨打我们电话：0755-83999818</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/faq-fail.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>浅谈FLuke DTX系列测试仪标准名称的改变</title>
		<link>http://www.faxytech.com/archives/standard-change.html</link>
		<comments>http://www.faxytech.com/archives/standard-change.html#comments</comments>
		<pubDate>Tue, 18 Sep 2012 01:03:44 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[acr]]></category>
		<category><![CDATA[ACR-F]]></category>
		<category><![CDATA[ACR-N]]></category>
		<category><![CDATA[dtx]]></category>
		<category><![CDATA[elfext]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[PSACR]]></category>
		<category><![CDATA[PSACR-F]]></category>
		<category><![CDATA[PSACR-N]]></category>
		<category><![CDATA[PSELFEXT]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=2294</guid>
		<description><![CDATA[???? 在全球知名品牌测试仪福禄克（fluke）公布DTX测试仪的最新固件版本后，在测试时会发现有一些参数是生面孔但是又似曾相识例如：ACR-N、PSACR-N、ACR-F、PSACR-F，但是ACR、PSACR、ELFEXT、PSELFEXT却... ]]></description>
			<content:encoded><![CDATA[<div><span style="color: #000000;">???? 在全球知名品牌测试仪<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>（fluke）公布<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>测试仪的最新固件版本后，在测试时会发现有一些参数是生面孔但是又似曾相识例如：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span>、PS<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-n" title="查看 ACR-N 的全部文章" target="_blank">ACR-N</a></span>、<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>、PS<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-f" title="查看 ACR-F 的全部文章" target="_blank">ACR-F</a></span>，但是ACR、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/psacr" title="查看 PSACR 的全部文章" target="_blank">PSACR</a></span>、ELFEXT、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/pselfext" title="查看 PSELFEXT 的全部文章" target="_blank">PSELFEXT</a></span>却不见了。在FLUKE官方的注释文档中就表示，ACR=ACR-N、PSACR=<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/psacr-n" title="查看 PSACR-N 的全部文章" target="_blank">PSACR-N</a></span>,ELFEXT=ACR-F，PSELFEXT=<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/psacr-f" title="查看 PSACR-F 的全部文章" target="_blank">PSACR-F</a></span>。<br />
??? 为什么ACR、PSACR、ELFEXTPSELFEXT可以被ACR-X取代呢？这首先要从ACR的概念说起。</span></div>
<div><span style="color: #000000;">? ? ACR（AttenuationtoCrosstalkRatio）<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>与<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>差：是指近端串扰损耗与衰减的差值。ACR是一个十分重要的物理量，是线对上信噪比的一个指标。ACR=0时表明在该线对上传输的信号强度与噪音强度一致，接收方无法识别哪些是有用的信号，哪些是噪声信号。因此，对应ACR=0的频率点越高越好。ACR的概念如下图所示：</span></div>
<div><span style="color: #000000;">? ? ELFEXT(EqualLeverFar End Crosstalk) 等(效)电平远端串扰：FEXT类似于<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>，但信号是从近端发出的，而串扰信号则是在远端测量到的。FEXT也必须从链路的两端来进行测量。可是，FEXT并不是一种很有效的测试指标。电缆长度对测量到的FEXT值的影响会很大，这是因为信号的强度与它所产生的串扰及信号在发送端的衰减程度有关。因此两条一样的电缆，会因为长度不同而有不同的FEXT值，所以就必须以ELFEXT值的测量来代替FEXT值的测量。EXFEXT值其实就是FEXT值减去衰减量后的值，也可以将ELFEXT理解成远端的ACR。ELFEXT的概念如下图所示：</span></div>
<div><span style="color: #000000;">? ? 至此，便可以看出，ACR与ELFEXT之间的有微妙的关系，只是近端与远端的区别。参数只是更改了一下名字但是参数的意义以及标准都没有变化。ACR-N代表ACRNearEnd即近端ACR，ACR-F代表ACRFar End即远端ACR。PS ACR-N、PS ACR-F自是不用赘言。</span></div>
<div><span style="color: #000000;">?? 截止目前为止（2012.9.17）福禄克软件版本为2.63，如有需要请联系连讯工程师：0755-83999818 83999298 </span></div>
<div>?</div>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/standard-change.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克测试仪中ACR与ELFEXT比较及电池校准</title>
		<link>http://www.faxytech.com/archives/fluke_713.html</link>
		<comments>http://www.faxytech.com/archives/fluke_713.html#comments</comments>
		<pubDate>Wed, 13 Jul 2011 13:46:10 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[acr]]></category>
		<category><![CDATA[elfext]]></category>
		<category><![CDATA[电池]]></category>
		<category><![CDATA[福禄克测试仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=1231</guid>
		<description><![CDATA[在全球知名品牌测试仪福禄克（fluke）公布DTX测试仪（DTX-1800，DTX-1200，DTX-LT）的最新固件版本后，在测试时会发现有一些参数是生面孔但是又似曾相识例如：ACR-N、PSACR-N、ACR-F、PSACR-F，但是ACR... ]]></description>
			<content:encoded><![CDATA[<p>在全球知名品牌测试仪福禄克（fluke）公布<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>测试仪（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-lt.html" title="福禄克FLUKE DTX-LT测试仪">DTX-LT</a></span>）的最新固件版本后，在测试时会发现有一些参数是生面孔但是又似曾相识例如：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span>、PSACR-N、<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>、PSACR-F，但是ACR、PSACR、ELFEXT、PSELFEXT却不见了。在FLUKE官方的注释文档中就表示，ACR=ACR-N、PSACR=PSACR-N,ELFEXT=ACR-F，PSELFEXT=PSACR-F。</p>
<p>　　为什么ACR、PSACR、ELFEXT、PSELFEXT可以被ACR-X取代呢？这首先要从ACR的概念说起。</p>
<p>　　ACR（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="Attenuation">Attenuation</a></span> toCrosstalkRatio）<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>与<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>差：是指近端串扰损耗与衰减的差值。ACR是一个十分重要的物理量，是线对上信噪比的一个指标。ACR=0时表明在该线对上传输的信号强度与噪音强度一致，接收方无法识别哪些是有用的信号，哪些是噪声信号。因此，对应ACR=0的频率点越高越好。ACR的概念如下图所示：</p>
<p><img src="http://i01.yizimg.com/ComFolder/33261/downpic/2011118143431929.jpg" alt="" align="center" /></p>
<p>?　　ELFEXT (Equal Lever Far EndCrosstalk)等(效)电平远端串扰：FEXT类似于<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>，但信号是从近端发出的，而串扰信号则是在远端测量到的。FEXT也必须从链路的两端来进行测量。可是，FEXT并不是一种很有效的测试指标。电缆长度对测量到的FEXT值的影响会很大，这是因为信号的强度与它所产生的串扰及信号在发送端的衰减程度有关。因此两条一样的电缆，会因为长度不同而有不同的FEXT值，所以就必须以ELFEXT值的测量来代替FEXT值的测量。EXFEXT值其实就是FEXT值减去衰减量后的值，也可以将ELFEXT理解成远端的ACR。ELFEXT的概念如下图所示：</p>
<p><img src="http://i01.yizimg.com/ComFolder/33261/downpic/2011118143432444.gif" alt="" align="center" /></p>
<p>　　至此，便可以看出，ACR与ELFEXT之间的有微妙的关系，只是近端与远端的区别。参数只是更改了一下名字但是参数的意义以及标准都没有变化。ACR-N代表ACRNearEnd即近端ACR，ACR-F代表ACR Far End即远端ACR。PS ACR-N、PS ACR-F自是不用赘言。</p>
<p>　　　</p>
<p>?<strong>什么是<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%94%b5%e6%b1%a0" title="查看 电池 的全部文章" target="_blank">电池</a></span>重新<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>，我们为什么需要它？<br />
</strong>在我们经常使用的FLUKE的网络测试设备上，锂离子电池的电量都是以“电量计”的形式显示的。从电量计中，我们可以准确的读出设备中的电池还有多少剩余电量，精确到以1%为单位。FLUKE的网络测试设备长久以来一直以这种方式显示电池的电量信息。</p>
<p>很多人可能都遇到过在设备出现低电量报警之后软启动，电量计又显示还剩20-30%电量的问题，或者是系统提示已经充满电，但是电池电量计只显示到90%，而不是100%。这时，我们就需要动手对电池的电量进行重新校准了。</p>
<p>尽管制造商们不推荐对锂电池进行深度放电（锂电池的这个特性和NiCd镍镉电池恰恰相反），但在锂电池每工作30-40个充电循环之后，还是建议对锂电池进行一次深度放电（对一般的FLUKE的网络测试设备来说这相当于使用了一年，到一年半），这样做的目的是校准电池上的电量<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克计量">计量</a></span>芯片。放电的原则很简单：慢速放电到设备的电量计显示接近0%，通常FLUKE的测试设备都会提供相应的快捷方式或者组合功能键实现电量校准的功能。然后电池的电量计量芯片就会从那里重新为电池计量电量。你要做的只是像每天给设备充电一样进行正常的充电，记住要关闭你的FLUKE的网络测试设备，然后再充电到设备上的LED指示灯指示充电完成。如果你坚持这样做，电池的寿命会变得更长。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/fluke_713.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
