<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; acr</title>
	<atom:link href="http://www.faxytech.com/tag/acr/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>浅谈FLuke DTX系列测试仪标准名称的改变</title>
		<link>http://www.faxytech.com/archives/standard-change.html</link>
		<comments>http://www.faxytech.com/archives/standard-change.html#comments</comments>
		<pubDate>Tue, 18 Sep 2012 01:03:44 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[acr]]></category>
		<category><![CDATA[ACR-F]]></category>
		<category><![CDATA[ACR-N]]></category>
		<category><![CDATA[dtx]]></category>
		<category><![CDATA[elfext]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[PSACR]]></category>
		<category><![CDATA[PSACR-F]]></category>
		<category><![CDATA[PSACR-N]]></category>
		<category><![CDATA[PSELFEXT]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=2294</guid>
		<description><![CDATA[???? 在全球知名品牌测试仪福禄克（fluke）公布DTX测试仪的最新固件版本后，在测试时会发现有一些参数是生面孔但是又似曾相识例如：ACR-N、PSACR-N、ACR-F、PSACR-F，但是ACR、PSACR、ELFEXT、PSELFEXT却... ]]></description>
			<content:encoded><![CDATA[<div><span style="color: #000000;">???? 在全球知名品牌测试仪<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>（fluke）公布<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>测试仪的最新固件版本后，在测试时会发现有一些参数是生面孔但是又似曾相识例如：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span>、PS<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-n" title="查看 ACR-N 的全部文章" target="_blank">ACR-N</a></span>、<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>、PS<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-f" title="查看 ACR-F 的全部文章" target="_blank">ACR-F</a></span>，但是ACR、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/psacr" title="查看 PSACR 的全部文章" target="_blank">PSACR</a></span>、ELFEXT、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/pselfext" title="查看 PSELFEXT 的全部文章" target="_blank">PSELFEXT</a></span>却不见了。在FLUKE官方的注释文档中就表示，ACR=ACR-N、PSACR=<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/psacr-n" title="查看 PSACR-N 的全部文章" target="_blank">PSACR-N</a></span>,ELFEXT=ACR-F，PSELFEXT=<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/psacr-f" title="查看 PSACR-F 的全部文章" target="_blank">PSACR-F</a></span>。<br />
??? 为什么ACR、PSACR、ELFEXTPSELFEXT可以被ACR-X取代呢？这首先要从ACR的概念说起。</span></div>
<div><span style="color: #000000;">? ? ACR（AttenuationtoCrosstalkRatio）<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>与<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>差：是指近端串扰损耗与衰减的差值。ACR是一个十分重要的物理量，是线对上信噪比的一个指标。ACR=0时表明在该线对上传输的信号强度与噪音强度一致，接收方无法识别哪些是有用的信号，哪些是噪声信号。因此，对应ACR=0的频率点越高越好。ACR的概念如下图所示：</span></div>
<div><span style="color: #000000;">? ? ELFEXT(EqualLeverFar End Crosstalk) 等(效)电平远端串扰：FEXT类似于<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>，但信号是从近端发出的，而串扰信号则是在远端测量到的。FEXT也必须从链路的两端来进行测量。可是，FEXT并不是一种很有效的测试指标。电缆长度对测量到的FEXT值的影响会很大，这是因为信号的强度与它所产生的串扰及信号在发送端的衰减程度有关。因此两条一样的电缆，会因为长度不同而有不同的FEXT值，所以就必须以ELFEXT值的测量来代替FEXT值的测量。EXFEXT值其实就是FEXT值减去衰减量后的值，也可以将ELFEXT理解成远端的ACR。ELFEXT的概念如下图所示：</span></div>
<div><span style="color: #000000;">? ? 至此，便可以看出，ACR与ELFEXT之间的有微妙的关系，只是近端与远端的区别。参数只是更改了一下名字但是参数的意义以及标准都没有变化。ACR-N代表ACRNearEnd即近端ACR，ACR-F代表ACRFar End即远端ACR。PS ACR-N、PS ACR-F自是不用赘言。</span></div>
<div><span style="color: #000000;">?? 截止目前为止（2012.9.17）福禄克软件版本为2.63，如有需要请联系连讯工程师：0755-83999818 83999298 </span></div>
<div>?</div>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/standard-change.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克测试仪中ACR与ELFEXT比较及电池校准</title>
		<link>http://www.faxytech.com/archives/fluke_713.html</link>
		<comments>http://www.faxytech.com/archives/fluke_713.html#comments</comments>
		<pubDate>Wed, 13 Jul 2011 13:46:10 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[acr]]></category>
		<category><![CDATA[elfext]]></category>
		<category><![CDATA[电池]]></category>
		<category><![CDATA[福禄克测试仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=1231</guid>
		<description><![CDATA[在全球知名品牌测试仪福禄克（fluke）公布DTX测试仪（DTX-1800，DTX-1200，DTX-LT）的最新固件版本后，在测试时会发现有一些参数是生面孔但是又似曾相识例如：ACR-N、PSACR-N、ACR-F、PSACR-F，但是ACR... ]]></description>
			<content:encoded><![CDATA[<p>在全球知名品牌测试仪福禄克（fluke）公布<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>测试仪（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-lt.html" title="福禄克FLUKE DTX-LT测试仪">DTX-LT</a></span>）的最新固件版本后，在测试时会发现有一些参数是生面孔但是又似曾相识例如：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span>、PSACR-N、<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>、PSACR-F，但是ACR、PSACR、ELFEXT、PSELFEXT却不见了。在FLUKE官方的注释文档中就表示，ACR=ACR-N、PSACR=PSACR-N,ELFEXT=ACR-F，PSELFEXT=PSACR-F。</p>
<p>　　为什么ACR、PSACR、ELFEXT、PSELFEXT可以被ACR-X取代呢？这首先要从ACR的概念说起。</p>
<p>　　ACR（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="Attenuation">Attenuation</a></span> toCrosstalkRatio）<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>与<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>差：是指近端串扰损耗与衰减的差值。ACR是一个十分重要的物理量，是线对上信噪比的一个指标。ACR=0时表明在该线对上传输的信号强度与噪音强度一致，接收方无法识别哪些是有用的信号，哪些是噪声信号。因此，对应ACR=0的频率点越高越好。ACR的概念如下图所示：</p>
<p><img src="http://i01.yizimg.com/ComFolder/33261/downpic/2011118143431929.jpg" alt="" align="center" /></p>
<p>?　　ELFEXT (Equal Lever Far EndCrosstalk)等(效)电平远端串扰：FEXT类似于<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>，但信号是从近端发出的，而串扰信号则是在远端测量到的。FEXT也必须从链路的两端来进行测量。可是，FEXT并不是一种很有效的测试指标。电缆长度对测量到的FEXT值的影响会很大，这是因为信号的强度与它所产生的串扰及信号在发送端的衰减程度有关。因此两条一样的电缆，会因为长度不同而有不同的FEXT值，所以就必须以ELFEXT值的测量来代替FEXT值的测量。EXFEXT值其实就是FEXT值减去衰减量后的值，也可以将ELFEXT理解成远端的ACR。ELFEXT的概念如下图所示：</p>
<p><img src="http://i01.yizimg.com/ComFolder/33261/downpic/2011118143432444.gif" alt="" align="center" /></p>
<p>　　至此，便可以看出，ACR与ELFEXT之间的有微妙的关系，只是近端与远端的区别。参数只是更改了一下名字但是参数的意义以及标准都没有变化。ACR-N代表ACRNearEnd即近端ACR，ACR-F代表ACR Far End即远端ACR。PS ACR-N、PS ACR-F自是不用赘言。</p>
<p>　　　</p>
<p>?<strong>什么是<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%94%b5%e6%b1%a0" title="查看 电池 的全部文章" target="_blank">电池</a></span>重新<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>，我们为什么需要它？<br />
</strong>在我们经常使用的FLUKE的网络测试设备上，锂离子电池的电量都是以“电量计”的形式显示的。从电量计中，我们可以准确的读出设备中的电池还有多少剩余电量，精确到以1%为单位。FLUKE的网络测试设备长久以来一直以这种方式显示电池的电量信息。</p>
<p>很多人可能都遇到过在设备出现低电量报警之后软启动，电量计又显示还剩20-30%电量的问题，或者是系统提示已经充满电，但是电池电量计只显示到90%，而不是100%。这时，我们就需要动手对电池的电量进行重新校准了。</p>
<p>尽管制造商们不推荐对锂电池进行深度放电（锂电池的这个特性和NiCd镍镉电池恰恰相反），但在锂电池每工作30-40个充电循环之后，还是建议对锂电池进行一次深度放电（对一般的FLUKE的网络测试设备来说这相当于使用了一年，到一年半），这样做的目的是校准电池上的电量<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克计量">计量</a></span>芯片。放电的原则很简单：慢速放电到设备的电量计显示接近0%，通常FLUKE的测试设备都会提供相应的快捷方式或者组合功能键实现电量校准的功能。然后电池的电量计量芯片就会从那里重新为电池计量电量。你要做的只是像每天给设备充电一样进行正常的充电，记住要关闭你的FLUKE的网络测试设备，然后再充电到设备上的LED指示灯指示充电完成。如果你坚持这样做，电池的寿命会变得更长。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/fluke_713.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>