<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; 线路问题，dtx具体应用</title>
	<atom:link href="http://www.faxytech.com/tag/%e7%ba%bf%e8%b7%af%e9%97%ae%e9%a2%98%ef%bc%8cdtx%e5%85%b7%e4%bd%93%e5%ba%94%e7%94%a8/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>如何利用福禄克Fluke DTX解决线缆实际问题？</title>
		<link>http://www.faxytech.com/archives/fluke_912.html</link>
		<comments>http://www.faxytech.com/archives/fluke_912.html#comments</comments>
		<pubDate>Mon, 12 Sep 2011 13:02:36 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dtx]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[线路问题，dtx具体应用]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=1513</guid>
		<description><![CDATA[福禄克Fluke DTX系列仪器有三款：DTX-1800，DTX-1200，DTX-LT。 如何利用福禄克Fluke DTX解决线缆实际问题？ 下面连讯工程师为大家讲解福禄克Fluke DTX系列仪器在解决线缆问题时的具体情况。 &#160; 案例... ]]></description>
			<content:encoded><![CDATA[<p><strong><a title="福禄克" href="http://www.faxytech.com">福禄克</a></strong><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fluke" title="查看 Fluke 的全部文章" target="_blank">Fluke</a></span> <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>系列仪器有三款：<strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span></strong>，<strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span></strong>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-lt.html" title="福禄克FLUKE DTX-LT测试仪">DTX-LT</a></span>。</p>
<p>如何利用<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>Fluke DTX解决线缆实际问题？</p>
<p>下面连讯工程师为大家讲解福禄克Fluke DTX系列仪器在解决线缆问题时的具体情况。</p>
<p>&nbsp;</p>
<p>案例:</p>
<p>同事小王向网络管理员小董反映，他的IP电话不能用,很多工作无法进行，需要小董帮他快速解决。</p>
<p>网管员小董检查发现电话机连上网线后指示灯闪了一下就灭了，怀疑是PoE供电问题或电话机坏了，但更换交换机端口及电话机，仍没有排除故障。这种故障只有小王的电话机存在，其他人的都很正常，小董判断这条链路可能存在问题，于是拿来DTX进行检测，发现这条链路的电阻有52欧姆，太大了。检查链路两端模块，发现墙壁上的模块存在打接不良问题，于是重新打接后，小王的IP电话恢复正常。</p>
<p>IP电话机通过PoE供电，如果链路中存在接触不良，则会引起很大的电压降，使IP电话无法获得工作所需的正常电压。处理这种故障，一般可以通过重新打线、更换模块、更换跳线就可排除。同时可以使用DTX测试仪确定链路存在电阻异常的位置，还可以用HDTDR来进行辅助检查，因为接触不良点也往往是<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>超标的地方。</p>
<p>有关DTX系列测试仪的任何问题，请深圳连讯达电子技术开发有限公司，我们将竭诚为您服务！</p>
<p>如何利用福禄克Fluke DTX（<strong>DTX-1800</strong>，<strong>DTX-1200</strong>，DTX-LT）解决线缆实际问题？您有新的发现吗？可以和连讯工程师交流。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/fluke_912.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
