<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; 福禄克维修</title>
	<atom:link href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b%e7%bb%b4%e4%bf%ae/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点</title>
		<link>http://www.faxytech.com/archives/f15-f17-wx6.html</link>
		<comments>http://www.faxytech.com/archives/f15-f17-wx6.html#comments</comments>
		<pubDate>Wed, 25 May 2016 00:41:06 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[F15B+维修]]></category>
		<category><![CDATA[F17B+维修]]></category>
		<category><![CDATA[福禄克维修]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7624</guid>
		<description><![CDATA[这个故障多数是因为波段开关接触不良， 如果从新安装波段开关以后还是不显示小数点那么就要检查小数点驱动电路部分了， 下图。 图中红圈的 74HC148 门电路就是小数点驱动电路的 IC， 直接... ]]></description>
			<content:encoded><![CDATA[<p>这个故障多数是因为波段开关接触不良， 如果从新安装波段开关以后还是不显示小数点那么就要检查小数点驱动电路部分了， 下图。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/05/f15-f17-wx6.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7626" title="FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点：" src="http://www.faxytech.com/wp-content/uploads/2016/05/f15-f17-wx6.png" alt="" width="664" height="487" /></a></p>
<p>图中红圈的 74HC148 门电路就是小数点驱动电路的 IC， 直接驱动小数点做动态显示， 首先检查 74 的 VDD 供电， 他的供电跟 FS9721_LP3的供电相同都是 3V， 也就是说只要 9721 得到了 3V 电源后 74 的 VDD就一定会产生， 74 的 VDD 3V 是跟 9721_LP3 的 48 脚相连的。 供电满足以后如果还是不显示小数点则要检查上拉电阻和下拉电阻， 是否出现虚焊阻值变化等如果都没有， 那么直接更换 74HC148 门电路即可。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/05/f15-f17-wx6-2.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7627" title=" 万用表开机不显示小数点任何挡位也均不显示小数点" src="http://www.faxytech.com/wp-content/uploads/2016/05/f15-f17-wx6-2.png" alt="" width="252" height="315" /></a></p>
<p>上图， 16 脚 IC 就是 74 门电路驱动小数点，绿色圈内部的是上拉和下拉电阻如果虚焊或损坏也会导致小数点出现问题。 很多朋友修这款 15B 和 17B 上来不管什么问题都直接换</p>
<p>我们所谓的“牛屎” 9721_LP3， 有的故障换牛屎兴许可以修复， 有的表故障换掉牛屎是修复不了的， 所以希望朋友们在维修的时候还是要看图纸， 分析故障， 上面只是简述一下我日常维修 F15B 和 17B 的一些故障经验，至于 F15B 改 17B 这不用我说了， 直接加上两个按键， 把该加上的元件按照原理图加上就可以。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>其他Fluke 15B 与F17B维修参考：</strong></p>
<p><span style="font-size: 13px; font-weight: normal;"><span style="color: #ff0000;"><strong>点击</strong>：</span><a href="http://www.faxytech.com/archives/f15-f17-wx.html">FLUKE 15B+与17B+维修故障1</a><strong><a href="http://www.faxytech.com/archives/f15-f17-wx.html">：</a></strong></span><a style="font-size: 1.17em;" title="福禄克F15B+和F17B+电路故障维修经验系列- 电表开机无任何显示" href="http://www.faxytech.com/archives/f15-f17-wx.html">电表开机无任何显示</a></p>
<p><span style="font-size: 13px; font-weight: normal; color: #ff0000;"><strong>点击：</strong></span><a style="font-size: 1.17em;" title="FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-wx2.html">FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修</a></p>
<p><span style="color: #ff0000;"><strong>点击：</strong></span><a style="font-size: 1.17em;" title="FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-wx3.html">FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修</a></p>
<p><span style="color: #ff0000;"><strong>点击：</strong></span><a style="font-size: 1.17em;" title="FLUKE 15B+与17B+维修故障4：AC/DC 电流挡不能测量故障" href="http://www.faxytech.com/archives/f15b-f17b-wx4.html">FLUKE 15B+与17B+维修故障4：AC/DC 电流挡不能测量故障</a></p>
<p><span style="color: #ff0000;"><strong>点击：</strong></span><a style="font-size: 1.17em;" title="FLUKE 15B+与17B+维修故障5：17B 温度挡不能测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-5.html">FLUKE 15B+与17B+维修故障5：17B 温度挡不能测量故障维修</a></p>
<p><span style="color: #ff0000;"><strong>点击：</strong></span><a style="font-size: 1.17em;" title="FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点" href="http://www.faxytech.com/archives/f15-f17-wx6.html">FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/f15-f17-wx6.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Fluke 15B+与Fluke 17B+维修小技巧-芯片级维修</title>
		<link>http://www.faxytech.com/archives/15b-maintain.html</link>
		<comments>http://www.faxytech.com/archives/15b-maintain.html#comments</comments>
		<pubDate>Thu, 28 Apr 2016 08:46:19 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[F15B+维修]]></category>
		<category><![CDATA[F17B+维修]]></category>
		<category><![CDATA[Fluke 15B+维修]]></category>
		<category><![CDATA[Fluke 17B+维修]]></category>
		<category><![CDATA[福禄克维修]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7508</guid>
		<description><![CDATA[对于好多电子爱好者来说，维修Fluke 15b+和Fluke ?17b+板载芯片好多人不知道方法，深圳连讯达作为福禄克维修站合作商，为大家讲解Fluke 15b+和Fluke ?17b+万用表更换方法： 1)故障诊断：不开机 检查... ]]></description>
			<content:encoded><![CDATA[<p>对于好多电子爱好者来说，维修Fluke 15b+和Fluke ?17b+板载芯片好多人不知道方法，深圳连讯达作为<span class='wp_keywordlink'><a href="http://www.faxytech.com/fluke-maintenance" title="福禄克维修">福禄克维修</a></span>站合作商，为大家讲解Fluke 15b+和Fluke ?17b+<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fluke-multimeter" title="Fluke福禄克万用表">万用表</a></span>更换方法：</p>
<p>1)故障诊断：不开机 检查供电电路，在供电部分有3v 电压！</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/04/17B.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7509" title="福禄克15B+ ,福禄克17B+芯片" src="http://www.faxytech.com/wp-content/uploads/2016/04/17B.jpg" alt="福禄克15B+ ,福禄克17B+芯片" width="607" height="434" /></a></p>
<p>2) 故障解决方案：打转盘任意位置，检查，供给芯片档位部分和供电部分，有电压供给，2个钽电容处有没有电压。大概判断方法位。2个电容正负脚有1.5v左右电压，如果出现2.4v 。另外一个电容正负脚肯定是0.5v左右电压（那恭喜你ic挂了）如果相等，那说明ic基本工作正常，在判断进入系统后的问题。安装好液晶，打转盘到电阻档，转盘接触确认无误后，如果电阻档现在电阻0.000 或者有阻值出现，基本可以判断位ic挂掉了，其他故障判断就不陈述了，更换方法，牛屎芯铲除，用热风枪加热，软化后用镊子铲刀剔除搞干净就ok 。至于焊接我就不陈述了，更换有风险，需要<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>。（不校准其实误差也不是很大)</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/04/15B.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7510" title="福禄克15B+ 与福禄克17B+万用表芯片维修" src="http://www.faxytech.com/wp-content/uploads/2016/04/15B.jpg" alt="福禄克15B+ 与福禄克17B+万用表芯片维修" width="431" height="550" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/15b-maintain.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克维修小技巧:DTX-1800升级的时候断电故障</title>
		<link>http://www.faxytech.com/archives/wexiu_dtx1800.html</link>
		<comments>http://www.faxytech.com/archives/wexiu_dtx1800.html#comments</comments>
		<pubDate>Tue, 10 Nov 2015 06:53:25 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[DTX1800升级]]></category>
		<category><![CDATA[fluke维修]]></category>
		<category><![CDATA[福禄克维修]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=6979</guid>
		<description><![CDATA[深圳连讯达维修部工程师为大家讲解福禄克维修小技巧：DTX-1800升级的时候断电故障。我们在升级福禄克DTX-1800仪器或者DTX-1500，DTX-1200，DTX-LT等福禄克测试仪的时候，我们是不能断电的。因为如... ]]></description>
			<content:encoded><![CDATA[<p>深圳连讯达维修部工程师为大家讲解<span class='wp_keywordlink'><a href="http://www.faxytech.com/fluke-maintenance" title="福禄克维修">福禄克维修</a></span>小技巧：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>升级的时候断电故障。我们在升级福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-1800仪器或者<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1500.html " title="福禄克FLuke DTX-1500">DTX-1500</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-lt.html" title="福禄克FLUKE DTX-LT测试仪">DTX-LT</a></span>等福禄克测试仪的时候，我们是不能断电的。因为如果福禄克电池电量不够，就会出现故障。</p>
<p><span style="color: #ff0000;"><strong>现象1：福禄克DTX-1800屏幕变白.</strong></span></p>
<p><span style="color: #ff0000;"><strong>现象2：福禄克DTX-1800 ?的USB线缆无反应。</strong></span></p>
<p>连讯达工程师提示您，可以尝试以下步骤。</p>
<p>— 关掉DTX<span style="font-family: 宋体;">系列仪器（</span><span style="font-family: Arial;">DTX-1800</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-1500</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-1200</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-LT</span><span style="font-family: 宋体;">等）。</span></p>
<p><span style="font-family: 宋体;">—</span> 按下【灯光】键和【Talk<span style="font-family: 宋体;">】键。</span></p>
<p>— 保持他们按下状态，打开DTX<span style="font-family: 宋体;">仪器。</span></p>
<p><span style="font-family: 宋体;">—</span>松开这些键。</p>
<p>— 等待DTX-1800<span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-1500</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-1200</span><span style="font-family: 宋体;">，</span><span style="font-family: Arial;">DTX-LT</span><span style="font-family: 宋体;">更新成功。</span></p>
<p><span style="font-family: 宋体;">—</span> 使用linware?<span style="font-family: 宋体;">软件，</span><span style="font-family: Calibri;">DTX</span><span style="font-family: 宋体;">系列仪器通过</span><span style="font-family: Calibri;">USB</span><span style="font-family: 宋体;">连接电脑开始更新。</span></p>
<p><span style="font-family: 宋体;"><br />
</span></p>
<h4><span style="font-family: 宋体;">如果福禄克DTX-1800远端出现了故障。用USB线连接远端。</span></h4>
<p>— 关掉DTX系列仪器（DTX-1800，DTX-1500，DTX-1200，DTX-LT等）。</p>
<p>—?按下【灯光】键和【Talk】键。</p>
<p>— 保持他们按下状态，打开DTX仪器。</p>
<p>—松开这些键。</p>
<p>— 等待DTX-1800，DTX-1500，DTX-1200，DTX-LT更新成功。</p>
<p>—?使用linware?软件，DTX系列仪器通过USB连接电脑开始更新。</p>
<p>&nbsp;</p>
<p><strong>其他故障现象：</strong></p>
<p>现象3：主机无法开机，辅机无法开机。</p>
<p>现象4：找不到远端。</p>
<p>现象5：测试参数差。</p>
<p>现象5：接线图故障，通道接口维修。</p>
<p><span style="color: #ff0000;"><strong>请联系连讯达维修：13715297556许工0755-83999818-801</strong></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/wexiu_dtx1800.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DTX-1800,DTX-1200,DTX-LT测试诊断过程中突然死机解决方案</title>
		<link>http://www.faxytech.com/archives/dtx-shut-down.html</link>
		<comments>http://www.faxytech.com/archives/dtx-shut-down.html#comments</comments>
		<pubDate>Sat, 21 Dec 2013 05:47:31 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DTX-1800故障]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[死机]]></category>
		<category><![CDATA[福禄克维修]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=3417</guid>
		<description><![CDATA[福禄克网络（Fluke Networks)的综合布线测试验收利器-DTX-1800，DTX-1200，DTX-LT大家都熟悉，如果测试过程中有时候会测试到一半会中途卡死，或者测试到一半失去信号找不到远端，这种情况下如何处... ]]></description>
			<content:encoded><![CDATA[<p>
	福禄克网络（<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span>)的<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="综合布线">综合布线</a></span>测试验收利器-<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span>，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-lt.html" title="福禄克FLUKE DTX-LT测试仪">DTX-LT</a></span>大家都熟悉，如果测试过程中有时候会测试到一半会中途卡死，或者测试到一半失去信号找不到远端，这种情况下如何处理呢？
</p>
<p>
	这种情况有几种解决方案：
</p>
<p>
	第一：我们可以试着重启<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-1800机器，如果重启后能正常工作，这个一般是软件出错引起的。
</p>
<p>
	第二：我们试着DTX系列软件升级，有时候重启后还一老重复故障，可能是程序丢失，我们可以升级软件程序。
</p>
<p>
	第三：有时候DTX-1800,DTX-1200,DTX-LT可能都不能重启了，这时候，我们需要取下电池15秒左右，取下电池是为了让故障程序故障消除。
</p>
<p>
	第四：如果以上方法都不能解决，我们要考虑硬件故障了。这时候要用到永久链路和通道适配器对福禄克一起进行自<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>。自校不失败，就需要送修了。
</p>
<p>
	第五：直接找深圳连讯达公司说明故障，检测FLUKE仪器。
</p>
<p>
	&nbsp;
</p>
<p>
	原文链接：<span style="color: rgb(102, 102, 102); font-family: 'Lucida Grande', Verdana, Arial, 'Bitstream Vera Sans', sans-serif, 新宋体, 宋体; line-height: 13px; background-color: rgb(249, 249, 249); ">&nbsp;</span><span id="sample-permalink" style="margin: 0px; padding: 0px; border: 0px; outline: 0px; background-color: rgb(249, 249, 249); color: rgb(102, 102, 102); font-family: 'Lucida Grande', Verdana, Arial, 'Bitstream Vera Sans', sans-serif, 新宋体, 宋体; line-height: 13px; ">http://www.faxytech.com/archives/<span id="editable-post-name" style="margin: 0px; padding: 0px; border: 0px; outline: 0px; background-color: rgb(255, 251, 204); background-position: initial initial; background-repeat: initial initial; " title="临时固定链接，点击更改这部分。">dtx-shut-down</span>.html</span>
</p>
<p>
	&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dtx-shut-down.html/feed</wfw:commentRss>