<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; 环形通量</title>
	<atom:link href="http://www.faxytech.com/tag/%e7%8e%af%e5%bd%a2%e9%80%9a%e9%87%8f/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>环形通量 —它是什么？</title>
		<link>http://www.faxytech.com/archives/what-is-ef.html</link>
		<comments>http://www.faxytech.com/archives/what-is-ef.html#comments</comments>
		<pubDate>Fri, 07 Jun 2013 06:58:55 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[环形通量]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=2935</guid>
		<description><![CDATA[随着 LC/MPO 盒之类低损耗光纤组件的推广应用，损耗预算（测试限制）变得越来越小。这样一来，安装商会发现以前进行光线测试的方法和假设不再适用。 虽然电信工业协会 (TIA) 依旧允许每个... ]]></description>
			<content:encoded><![CDATA[<p>随着 LC/<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span> 盒之类低损耗光纤组件的推广应用，损耗预算（测试限制）变得越来越小。这样一来，安装商会发现以前进行光线测试的方法和假设不再适用。</p>
<p>虽然电信工业协会 (TIA) 依旧允许每个连接器的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>为 0.75 dB，但工厂抛光连接器的衰减接近 0.2 dB。因此，在测试 TIA 极限值时，安装商面对诸多的不确定性。换句话说，他们的测试实践需要合理化，而不求完美。</p>
<p>然而，咨询人员和布线供应商现在都开始根据组件性能而不是标准精确计算损耗预算。测试实践中的允许公差已不存在。为了与时俱进，安装商需要重新评估他们的<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>设备和程序。</p>
<p>通过舱壁接合器设置基准不再是可有可无，而必须运用一条基准测试线（1 个跳接）保持从源到仪表的基准。进行某些设置时，需要对新的测试设备进行投资并提供一些必要相关培训。</p>
<p>测试基准线也必须配备基准等级连接器，ISO/IEC 14763-3将其定义为在多种模式下=0.1 dB，在单一模式下 =0.2 dB。当低损耗盒配备 0.15 dB LC 连接器时，若使用任何不及 0.15 dB 的 LC 连接器进行测试，结果将不容乐观或者可能失败。</p>
<p>当许多安装商正竞相调整和优化他们的测试程序时，在本篇文章的最后部分将介绍降低测量不确定性的方法，您可能已经听说过。它称作<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/what-is-ef.html" title="环形通量 ">环形通量 </a></span>(EF)。</p>
<p>如果两个技术人员使用带基准等级连接器及心轴的相同基准测试线，但采用两种不同的光源，那么可能会出现两种不同的读数。我们从 ISO/IEC 14763-3在测量不确定性方面所做的工作了解到，使用相同的源能够将衰减度限制在 +/- 0.09 dB 范围内。</p>
<p>这便是光纤测试的性质。光纤连接被认为是随机的，这是配备基准等级连接器非常重要的原因。然而，如果您当时使用两个不同的光源，即使您已经对它们做出了调整，也会出现额外的不确定性。这一不确定性是由光射入光纤的方式导致的。</p>
<p>很多年前，虽然有时被称为耦合效率 (CPR)，TIA 还是尝试这一发射概念定义。那是一个很好的尝试，但源之间的发射依然存在太多的可变性。因此，在2010中， TIA 和 IEC 创建了 EF，以便进一步限制发射条件。</p>
<p>关于那些插入标准数字的排列，您需要留意针对 EF 的 ANSI/TIA-526-14-B 或 IEC61280-4-2 （它们是相同的文档）。缺失这个标准即是如何在这一领域进行实施。很多人认为，这是属于实验室的要求，因为目前在这一领域的实施状况并不理想。</p>
<p>为此， TIA 正致力于解决 TIA-TSB-4979 的实际问题，以实现这一领域多模发射的条件。电信系统公告介绍了两种方法。一种是使用替代心轴的模式调节器，这种方法不太令人满意（而且成本不菲）。另外一种方法是配备剔除了多余模式设备的 EF 兼容源。</p>
<p>EF 兼容似乎将成为接下来一年许多测试规范的需求，因此，安装商可能会关注这一领域的发展。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/what-is-ef.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>如何通过环形通量提高多模测试准确性</title>
		<link>http://www.faxytech.com/archives/ef-2.html</link>
		<comments>http://www.faxytech.com/archives/ef-2.html#comments</comments>
		<pubDate>Fri, 07 Jun 2013 06:35:15 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dtx-1800]]></category>
		<category><![CDATA[DTX-EFM2]]></category>
		<category><![CDATA[Fluke Networks]]></category>
		<category><![CDATA[万兆光纤]]></category>
		<category><![CDATA[光纤损耗]]></category>
		<category><![CDATA[多模光纤]]></category>
		<category><![CDATA[环形通量]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[福禄克网络]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=2928</guid>
		<description><![CDATA[如何通过环型通量提高多模测试准确性 ?文章来自福禄克网络 Anyone who’s ever tested a multimode fiber optic link with light sources from different equipment?vendors will know that the loss measurement can vary by as much as 50 per... ]]></description>
			<content:encoded><![CDATA[<p>如何通过环型通量提高多模测试准确性 ?文章来自<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>网络</p>
<p>Anyone who’s ever tested a multimode fiber optic link with light sources from different equipment?vendors will know that the loss measurement can vary by as much as 50 percent.若未进行适当控制，则多模光源会以不同的方式将光注入<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%a4%9a%e6%a8%a1%e5%85%89%e7%ba%a4" title="查看 多模光纤 的全部文章" target="_blank">多模光纤</a></span>。?即使采用同一制造商生产的光源，但在不同的发射条件下也会产生不同的链路损耗测量结果，最终出现不同的 — 并且通常令人困惑的 — 测试结果。</p>
<p>Overfilling tends to produce link-loss measurements that are inappropriately high and under filling tends to generate loss measurements that are optimistic in regards to the loss that will occur in the cabling once it is operational.?不同类型的光源会有不同的发射条件。例如：发光二极管 (LED) 会使多模光纤过多填充模式组，而激光又未使光纤填充足够的模式组。</p>
<p>这些有缺陷的结果最终会影响布线基础设施的性能，并且会造成数据中心和其它依靠光纤布线连接组件的环境方面的严重问题。</p>
<p>当考虑到网络技术已经进步并且损耗预算已经减少时，这就有些雪上加霜了。为了满足紧缩的损耗预算，必须最大限度地减少测试不确定性。因此，新型高性能宽带业务应用程序就成了现场测试仪器进行更准确和可重复进行多模<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>测量所需的动力。</p>
<p>行业专家认为有必要减小发射条件偏差，这在测试 1 GB 或更高多模光纤时显得尤为必要。</p>
<p>那么，解决方案是什么呢？答案是利用一种称为<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/what-is-ef.html" title="环形通量 ">环形通量 </a></span>(EF) 的标准，这是一种对以往方法所作的重大改进。<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%8e%af%e5%bd%a2%e9%80%9a%e9%87%8f" title="查看 环形通量 的全部文章" target="_blank">环形通量</a></span> (EF) 是一种分析多模光源（例如： LED 或激光）启动条件的方法。它是在光源将光照射入多模光纤时光纤芯径内的功率百分比，并且它是通过近场测量来自连接测试仪器的参考等级测试线端的光确定的。</p>
<p>EF 标准可以将损耗测量的偏差减少至 +/- 10%。与以前允许高达40% 偏差的标准相比，EF 标准在多模测试的准确性和可重复性方面有了大幅改善。因此，需要进行线缆认证以及批准布线保证的相关组织和人员已经开始要求遵守这一新标准。</p>
<p>目前有可用于现场测试的环形通量 (EF) 解决方案。它们被称作“发射控制器”，是与模式调节器一起安装的特制测试级参考线。发射控制器的工作原理是在 EF 技术指标范围内限制测试线发射的模式组数量。这样可确保根据标准，结果测量是精确且可重复的。</p>
<p>是否达到环形通量 (EF) 标准由测试仪器供应商确认，它们使用专门的实验室设备对多模光纤内包含的不同模式之间的功率分布直接进行测量。</p>
<p>测量包括使用视频和处理方法，分析测试线端的近场分布。图像会转变为数据和图解说明。可以在选定的 EF 限值范围内绘图，以检查其是否合规。</p>
<p>The Telecommunications Industry Association (TIA) and?International Electrotechnical Commission (IEC) standards bodies both have documents that describe the requirements for EF.</p>
<p>EF 在将多模链路损耗测量缩小至 10% 偏差目标方面是一个重大进步。它将改善诸如模态功率分布和耦合功率之类的旧方法。由于符合 EF 标准的测试仪器会为认证测试提供最可靠的结果，因此网络工程师和设计师需要更新他们的测试技术指标，以要求使用符合 EF 标准的光源。</p>
<p>值得高兴的是<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> ?今年已经推出<span style="font-size: 1.5em;">Fluke <strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>–EFM2 </strong>环型通量多模光纤模块 ?配合<strong><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span></strong>我们就可以实现测试环境了。</span></p>
<p>&nbsp;</p>
<p>相关阅读<span style="font-size: 1.5em;"><a href="http://www.faxytech.com/archives/ef.html">光纤环型通量 (EF) 测量白皮书</a>：</span><a href="http://www.faxytech.com/archives/ef.html">http://www.faxytech.com/archives/ef.html</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/ef-2.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
