<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; 光纤环型通量</title>
	<atom:link href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e7%8e%af%e5%9e%8b%e9%80%9a%e9%87%8f/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>白皮书：光纤环型通量循环法测试</title>
		<link>http://www.faxytech.com/archives/ef-cycle.html</link>
		<comments>http://www.faxytech.com/archives/ef-cycle.html#comments</comments>
		<pubDate>Tue, 23 Dec 2014 02:26:28 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DTX-EFM2]]></category>
		<category><![CDATA[光纤环型通量]]></category>
		<category><![CDATA[循环法测试]]></category>
		<category><![CDATA[白皮书]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=5590</guid>
		<description><![CDATA[简介 多模光纤光源的环型通量 (EF) 发射一直受到标准委员会、设备供应商和用户的欢迎。TIA 工作小组 TR42.11 启动了大型循环法测试，这吸引了许多有兴趣的参与者以及许多 IEC 和 ISO 小组委员... ]]></description>
			<content:encoded><![CDATA[<h4><strong>简介</strong></h4>
<p>多模光纤光源的环型通量 (EF) 发射一直受到标准委员会、设备供应商和用户的欢迎。TIA 工作小组 TR42.11 启动了大型<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%be%aa%e7%8e%af%e6%b3%95%e6%b5%8b%e8%af%95" title="查看 循环法测试 的全部文章" target="_blank">循环法测试</a></span>，这吸引了许多有兴趣的参与者以及许多 IEC 和 ISO 小组委员会成员。启动的此次循环法测试旨在检查用于 EF 测量设备的当前状态。有人怀疑由于 EF 是受限发射，因此 EF 设备可能不具有可降低测量不确定性的精度。数年前在 IEC SC86B 标准范围内进行了类似测试，数据显示被测的某些模发射设备超出了 EF 模板。如果测试时对设备进行了正确<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>，就不会出现这个问题。新循环法测试的目的在于测量 EF 测量设备的变化性，并帮助进行此类型测试的人员树立信心。循环法测试为期 19 个月。测试样本经过了代表北美、欧洲和日本公司的 14 名参与者的评定。研究中使用过了五种不同类型的近场发射测量设备。循环法使用的测试样本是两个 LED 双波长光源。由于循环法的目的是测量 EF 设备之间的差异，因此这些测试样本本身并不代表经过校准符合 EF 的发射。</p>
<h4><strong>测试协议</strong></h4>
<p>测试期间使用的 LED 光源是包含双波长 850/1300 nm“组合器”的生产单元。两种光源均可配合 50 ?m 或 62.5 ?m 光纤测试线使用。光纤测试线长度为 1 米，被永久固定在光源的隔板上。用于 50 μm 和用于 62.5 μm 的仪器如测试线般安装在平台上。测试期间只可操作一小段测试线。测试线上安装了用作调谐模式过滤器的多个“空转”。对模式过滤器进行了“调谐”，以将 850 nm 设置在 EF 模板的目标上。1300 nm 响应保持在 EF 模板内，但与其目标之间存在偏差。EF 设备带有独立的用于 850 nm 和 1300 nm 的成像系统时会出现此情况。参与者收集了不同 EF 案例的数据：850/1300 nm 用于 50 ?m 布线，850/1300 nm 用于 62.5 ?m 布线。为了进行简化，并且由于对 50 ?m布线数据的更多关注，此份文件只显示了该数据。要求各参与者进行三次测量，但在最终分析时使用的是平均值。为便于控制，将光源返还至名为“参照测试台”的原始地点，在此对其进行重新检查、更换电池等操作。在将光源交付给参与者之前收集数据，参与者完成测量并返还光源。北美和欧洲各设有一个EF 参照测试台。在各参照测试台处进行的测量被用于建立基线。</p>
<h4><strong>目的</strong></h4>
<p>此次循环法测试的目标包含多个部分如前所述，主要原因是评估 EF 测试设备之间的差异。第二目标是发现测量的异常和异常值，以确定根源。第三目标是获得 EF 测试的信心，因此将测试仪器用于现场时，我们可以感受到对网络<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>测量的信心。第四目标是进行所有参与者测量数据平均值的不确定性分析，并为测量指定设置不确定性。</p>
<h4><strong>数据解释</strong></h4>
<p>为了降低不明确性并排除循环法测试的样本变化性，我们对测试结果进行了标准化。换言之，参与者的测试是相对于将样本交付给参与者之前进行的基线测试进行的。基线测试用于以 EF 模板量级为界限建立新的 EF 目标。100% 和 -100% 界限表示 EF 上限和下限之间的范围，不是真实值。</p>
<p>EFLΔ 和 EFUΔ 表示相对于 EF 目标（现已被基线测试代替）的 EF 模板量级。基线 #5 是向参与者发送样本之前进行的测试。测试 #5 是实际的参与者测试。后测试 #5 是参与者 #5 返还样本之后进行的测试。在此示例中，参与者 #5 保持在 EF 模板内。更多详情参见图 1。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/12/dtx-efm1.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5591" title="福禄克对比前后基线测试的测试结果" src="http://www.faxytech.com/wp-content/uploads/2014/12/dtx-efm1.jpg" alt="" width="554" height="329" /></a></p>
<p>图 1 – 对比前后基线测试的测试结果</p>
<h4><strong>长期偏移</strong></h4>
<p>在循环法测试之初观察到了样本的偏移现象。由于在测试方法中采用了标准化测量，因偏移可能已影响到结果，因此未被包含在数据中。独立测试表明测试线使用的 3 mm 护套出现收缩。经过数周，这种收缩在<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>升高的恒温槽中重现。收缩使得模式过滤量多于测试样本首次设置的过滤量。图 2 显示了 9 个月的期限内 EF 响应的变化。原始测试样本被设置在位于两个虚线中间的 EF 目标上。如果不熟悉 EF 模板，图 2 只显示了 20 ?m 和 22 ?m 处的模板。此区域是对使用测试设备进行的损耗测量影响最大的区域。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/12/dtx-efm2-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5592" title="2 – 9 个月的期限内的样本偏移" src="http://www.faxytech.com/wp-content/uploads/2014/12/dtx-efm2-2.jpg" alt="" width="539" height="364" /></a></p>
<p>图 2 – 9 个月的期限内的样本偏移</p>
<p>850 nm 50 μm 测试结果为了简明起见，此份文件中并未显示所有数据。由于 50 ?m 布线中的 850 nm 处是最重要的区域，图 3 显示了此区域的所有数据。所有 14测试都被合成在一个图片中，以显示平均值以及基于结果分布的一测回标准偏差带。一测回标准偏差表示，所有 EF 测量值在模板内的置信系数均为 75%。在循环法测试期间，所有参与者均在 EF 模板内。但是由于参与者之间的分布不同，因此标准偏差提高。在图 4 中，显示了平均值和二测回标准偏差。二测回标准偏差表示，EF 结果保持在标准偏差限值内的置信系数为 95%。注意在 20 ?m 控制点上，二测回标准偏差虚线稍稍超出了 EF 模板。这个数量表示，在布线衰减测量期间存在 1.8% 的不确定性。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/12/dtx-efm2-3.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5593" title="福禄克Fluke DTX-EFM2测试：测试的平均值和一测回标准偏差" src="http://www.faxytech.com/wp-content/uploads/2014/12/dtx-efm2-3.jpg" alt="" width="555" height="330" /></a></p>
<p>图 3 – 测试的平均值和一测回标准偏差</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2014/12/dtx-efm2-4.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-5594" title="福禄克DTX-EFM2：测试的平均值和二测回标准偏差" src="http://www.faxytech.com/wp-content/uploads/2014/12/dtx-efm2-4.jpg" alt="" width="552" height="329" /></a></p>
<p>图 4 – 测试的平均值和二测回标准偏差</p>
<p>摘要14 名参与者使用不同的 EF 测量设备对两个 LED 光源进行了测试。各参与者均在初始基线测试的短时间内完成了测试。通过将基线设置为零对所有测试进行了标准化。在两个地点使用了参照测试台。观察到较慢的 EF 响应偏移，这归因于温度对 3 mm 护套的影响。所有参与者均在 EF 模板内。平均 EF 结果在 EF 限值内，但由于使用了两个西格玛值，测试分布未被严格分组。使用平均 EF 值和一测回标准偏差（75% 的置信系数），所有参与者均在 EF 模板内。对于二测回标准偏差（95% 的置信系数），在一个控制点处存在另外 1.8% 的不确定性（20 ?m 用于 850 nm/50 μm）。</p>
<p>结论实际应用中的 EF 测量可以具有一定的合理不确定性。并且即便使用二测回标准偏差范围和稍稍超出模板的结果，EF 也比模功率分布 (MPD)等原来的标准好很多。但是，人们肯定认为不确定性主要取决于模板目标是否符合 EF 标准。这使得他们会更加注重 850 nm 下 50 ?m 的布线方法。但此时，EF 标准不区分波长和光纤尺寸的规范和信息要求。EF 结果分布可能与校准差异、用户技巧和不同设备类型、IEC 61280-1-4 不合规性及其他因素相关。通过更好的校准和跟踪改善系统不确定性将使标准偏差得到改善（降低分布）。此时使用精准工件校准的 EF 设备无需依赖对国家标准实验室的追溯。有关符合环型通量解决方案的更多信息 — 请访问?http://www.faxy-tech.com/Products/<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>-EFM2.html</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/ef-cycle.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【福禄克】Fluke DTX–EFM2 环型通量万兆多模光纤模块DTX-1800-E</title>
		<link>http://www.faxytech.com/archives/dtx-efm2.html</link>
		<comments>http://www.faxytech.com/archives/dtx-efm2.html#comments</comments>
		<pubDate>Mon, 03 Jun 2013 00:39:44 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[福禄克光缆测试产品]]></category>
		<category><![CDATA[dtx]]></category>
		<category><![CDATA[DTX–EFM2]]></category>
		<category><![CDATA[万兆多模光纤]]></category>
		<category><![CDATA[光纤测试仪]]></category>
		<category><![CDATA[光纤环型通量]]></category>
		<category><![CDATA[光纤认证测试仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=2908</guid>
		<description><![CDATA[深圳连讯（0755-83999818）销售福禄克FLuke DTX–EFM2 环型通量万兆多模光纤模块，技术服务一流，福禄克光纤测试仪价格全国最低，欢迎咨询！由于当今对于包含光纤和双绞线布线在内的高速数据... ]]></description>
			<content:encoded><![CDATA[<p>深圳连讯（0755-83999818）销售福禄克FLuke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-cableanalyzer.html" title="福禄克FLUKE DTX">DTX</a></span>–EFM2 环型通量<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e4%b8%87%e5%85%86%e5%a4%9a%e6%a8%a1%e5%85%89%e7%ba%a4" title="查看 万兆多模光纤 的全部文章" target="_blank">万兆多模光纤</a></span>模块，技术服务一流，福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>价格全国最低，欢迎咨询！由于当今对于包含光纤和双绞线布线在内的高速数据网络的需求，认证并记录多种媒体类型以确保进行正确安装比以往更为重要。DTX CableAnalyzer<span style="font-size: 12px;"> (<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1200.html" title="福禄克FLUKE DTX 1200测试仪">DTX-1200</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-lt.html" title="福禄克FLUKE DTX-LT测试仪">DTX-LT</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-clt.html" title="福禄克FLUKE DTX-CLT测试仪">DTX-CLT</a></span>)</span> 允许您使用板载光纤模块对光纤布线进行认证。这些模块增强了两光纤、双波长测试的认证功能和用 <span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>专业记录测试结果的功能，比其他光纤测试解决方案更加方便，功能更加强大。您不仅可以对两种光纤和<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>进行认证，认证速度也比您想象的更为快捷、高效。</p>
<p>随着环型通量 (EF) 多模光纤模块的推出，DTX CableAnalyzer 可提供符合 TIA-526-14-B 和 IEC 61280-1-4 EF 要求的有效且实用的解决方案。</p>
<div>
<h4>福禄克FLuke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-efm2.html" title="福禄克FLuke DTX–EFM2">DTX–EFM2</a></span> 环型通量多模光纤模块产品简介：</h4>
<p><a href="http://www.faxytech.com/wp-content/uploads/2013/06/dtx-efm2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignright size-full wp-image-2910" title="福禄克Fluke dtx-efm2万兆认证光模块" src="http://www.faxytech.com/wp-content/uploads/2013/06/dtx-efm2.jpg" alt="福禄克Fluke dtx-efm2万兆认证光模块" width="395" height="312" /></a></p>
<p>用于快速多模光纤认证符合环型通量的光纤损耗测试工具包 (OLTS)。</p>
</div>
<ul>
<li>带有 DTX CableAnalyzer? 符合环型通量 (EF) 的有效多模光纤测试</li>
<li>带有板载模块和 EF 测试参考线最紧凑实用的 EF 解决方案</li>
<li>12 秒自动测试 — 对两根光纤的两个波长进行损耗测量，光学损耗预算计算，以及“通过/失败”结果</li>
<li>使用 LinkWare? 软件快速记录符合 EF 的测试结果</li>
<li>连通性和极性验证简单</li>
<li>板载可视化故障定位器 (VFL) 可确定光纤位置和断开位置</li>
</ul>
<p>由于企业带宽需求提高，对于安装人员和网络所有者而言，对他们的光纤链路进行符合行业标准的认证并记录从而防止网络中断和利润损失比以往更为重要。</p>
<p>用于 DTX CableAnalyzer 的 <span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> DTX-EFM2 环型通量多模模块可使您在确保合规性的同时进行轻松准确的测试。TIA-526-14-B 和 IEC 61280-1-4 标准中限定了 EF 要求。环型通量合规性可将损耗测量偏差降低至目标值 +/- 10%，从而降低测量不确定性并提高每次测量的可重复性。这是电缆制造商期待的保修标准。</p>
<p>与 EF 测试参考线 (DTX-EFM2) 匹配的 DTX 环型通量光纤模块是快速升级以实现 EF 合规性的简单方法。无需进行专业培训或更改正常测试程序。</p>
<h4>福禄克FLuke <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dtx%e2%80%93efm2" title="查看 DTX–EFM2 的全部文章" target="_blank">DTX–EFM2</a></span> 环型通量多模光纤模块产品特性<span style="font-weight: normal;"> </span></h4>
<div id="14429q">
<h3><strong>符合环型通量的多模光纤认证</strong></h3>
</div>
<div id="14429a">
<p>TIA-526-14-B 和 IEC 61280-1-4 现在需要更严格的启动条件才可降低测试不确定性。对于熟悉 DTX CableAnalyzer 的用户，无需额外培训即可通过 DTX-EFM2 利用这些新模块执行符合 EF 的测试。带有环型通量测试参考线 (EF-TRC) 的 DTX-EFM2 可提供最有效实用符合 EF 标准的测试解决方案。分别对这些 EF-TRC 进行了调谐，以使任何 DTX-EFM2 均可在 EF-TRC 末端进行符合 EF 的发射。</p>
</div>
<div id="14404q">
<h3><strong>基本（第 1 级）光纤认证</strong></h3>
</div>
<div id="14404a">
<p>DTX 光纤模块提供基本（第 1 级）光纤认证解决方案 – 损耗、长度和极性测量。根据业界标准验证光纤链路性能。在多个波长上测量光损耗、测量光纤长度以及验证极性。您可以不可思议的速度对两根光纤的两个波长进行双向测试，而且无需交换主装置和远端装置，这是 Fluke Networks 独家提供的功能。可互换使用的接头适配器允许参考和测试连接线路，如果该连接满足大多数 SFF（小型）光纤接头的 TIA/ISO 标准。</p>
<p>竞争厂商的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e6%b5%8b%e8%af%95%e4%bb%aa" title="查看 光纤测试仪 的全部文章" target="_blank">光纤测试仪</a></span>每次自动测试时仅能测量长度和两种损耗的测量值，与之不同的是，DTX 是唯一能够在每次自动测试时测量长度和四种损耗测量值（所有这些均在大约12秒内完成）的光纤测试解决方案。有了 DTX 光纤模块，光纤测试速度可较竞争厂商提高五倍。</p>
</div>
<div id="14405q">
<h3><strong>Linkware? 报告</strong></h3>
</div>
<div id="14405a">
<p><strong>使用 LinkWare Cable Test Management Software 节省了管理测试结果的时间</strong></p>
<p>您也可以从我们的网站免费获得 LinkWare。当您完成工作后，即可将这个功能强大的应用程序交给客户，这样他们就能通过电子方式立即使用数据。您也可打印测试结果或将数据导出为 Adobe 的 PDF 文档。</p>
<p><strong>LinkWare 的全面数据管理功能：</strong></p>
<ul>
<li>现在包含在 LinkWare 7.x 中的 LinkWare Stats<sup>TM</sup> 使您能够全面地了解整个布线设备的性能</li>
<li>使用单一的软件管理铜缆和光缆测试结果，支持 Fluke Networks 的全线<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="电缆测试仪">电缆测试仪</a></span></li>
<li>提供专业、定制的图形化报表，采用适合所有 Fluke Networks 线缆测试仪的通用格式</li>
<li>具有配置和打印符合 TIA 606-A 标准的文档的能力</li>
<li>拖放功能可以更方便地管理和组织多个项目</li>
<li>与主要的 CMS（线缆管理软件）应用程序兼容</li>
<li>借助广受全球用户喜爱的线缆测试管理软件 LinkWare 的简单用户界面和省时功能，提高工作效率</li>
</ul>
<p>LinkWare 软件可以打印专业的图形化报表，并采用彩色图表来描述所测得的测试参数。可以选择要打印的参数以及图形显示的顺序。也可以用您公司的徽标定制报表。</p>
</div>
<h4>福禄克FLuke DTX–EFM2 环型通量多模光纤模块产品选型：</h4>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>DTX-EFM2&nbsp;</p>
<div><a>金牌支持服务??</a></div>
</td>
<td>双件套装 DTX 环型通量多模光纤模块，分别包括：<br />
组合到单个输出端口的 850 nm 和 1300 nm LED 光源<br />
符合环型通量的套装测试参考线 (EF-TRC)<br />
850/1300/1310/1550 nm 功率计<br />
集成 VFL</td>
</tr>
<tr>
<td>DTX-1800-E&nbsp;</p>
<div><a>金牌支持服务??</a></div>
</td>
<td>DTX-1800 和双件套装 DTX 环型通量多模光纤模块，分别包括：<br />
组合到单个输出端口的 850 nm 和 1300 nm LED 光源<br />
符合环型通量的套装测试参考线 (EF-TRC)<br />
850/1300/1310/1550 nm 功率计<br />
集成 VFL</td>
</tr>
<tr>
<td>DTX-1800-E 120/GLD</td>
<td>带环形通量多模光纤模块的 DTX-1800 及一年金牌支持<em>（仅限于美国和欧洲。欧洲订购 DTX-1800-E/GLD-EU）</em></td>
</tr>
</tbody>
</table>
<div>零配件</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>MRC-50EFC-SCLCKIT</td>
<td>50 ?m LC 双工光纤测试工具包</td>
</tr>
<tr>
<td>MRC-50EFC-SCSCKIT</td>
<td>50 ?m SC 光纤测试工具包</td>
</tr>
<tr>
<td>MRC-50EFC-SCSTKIT</td>
<td>50 ?m ST 光纤测试工具包</td>
</tr>
<tr>
<td>MRC-50EFC-SCFCKIT</td>
<td>50 ?m FC 光纤测试工具包</td>
</tr>
<tr>
<td>MRC-625EFC-SCLCKIT</td>
<td>62.5 ?m LC 光纤测试工具包</td>
</tr>
<tr>
<td>MRC-625EFC-SCSCKIT</td>
<td>62.5 ?m SC 光纤测试工具包</td>
</tr>
<tr>
<td>MRC-625EFC-SCSTKIT</td>
<td>62.5 ?m ST 光纤测试工具包</td>
</tr>
<tr>
<td>MRC-625EFC-SCFCKIT</td>
<td>62.5 ?m FC 光纤测试工具包</td>
</tr>
</tbody>
</table>
<h4>福禄克FLuke DTX–EFM2 环型通量多模光纤模块技术参数：</h4>
<table id="SpecTablenohead0" border="0" cellspacing="0">
<tbody>
<tr>
<td colspan="2">光学规格 (23?C)</td>
</tr>
<tr>
<td>输入（仪表）接头</td>
<td>产品标配的可拆卸 SC 适配器。可选的可拆卸适配器：LC、ST 和 FC</td>
</tr>
<tr>
<td>输出（光源）接头</td>
<td>固定 SC 适配器</td>
</tr>
<tr>
<td colspan="2">光源类型和额定波长</td>
</tr>
<tr>
<td>光源功率</td>
<td><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-xfm2.html" title="DTX系列分析仪仪光纤测试模块">DTX-MFM2</a></span>：≥ -20 dBm，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-xfm2.html" title="DTX系列光缆测试模块">DTX-SFM2</a></span>：≥ -7 dBm</td>
</tr>
<tr>
<td>长度测量</td>
<td>DTX-MFM2：≤ 5,000 m，62.5 或 50 μm 光纤<br />
DTX-EFM2：≤ 5,000 m，62.5 或 50 μm 光纤<br />
DTX-SFM2：≤ 10,000m，9 μm 单模光纤</td>
</tr>
<tr>
<td>功率计类型</td>
<td>InGaAs 检测器</td>
</tr>
<tr>
<td>功率测量范围</td>
<td>0 至 -60 dBm（1310 nm 和 1550 nm）<br />
0至 -52 dBm（850 nm）</td>
</tr>
<tr>
<td>带 EF-TRC* 的 DTX-EFM2 启动条件</td>
<td>环型通量符合 TIA 526-14-B、ISO/IEC 14763-3和 IEC 61280-4-1 标准</td>
</tr>
<tr>
<td colspan="2">VFL 规格 (23?C)</td>
</tr>
<tr>
<td>激光类型和额定波长</td>
<td>Class II CDRH，650 nm</td>
</tr>
<tr>
<td>输出模式</td>
<td>连续波和闪烁模式</td>
</tr>
<tr>
<td>接头适配器</td>
<td>2.5 mm 通用</td>
</tr>
<tr>
<td colspan="2">环境规格</td>
</tr>
<tr>
<td>工作<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span></td>
<td>0°C 至 40°C</td>
</tr>
<tr>
<td>贮存温度</td>
<td>-20°C 至 60°C</td>
</tr>
<tr>
<td>安全</td>
<td>CE、CSA、EN 61010-1</td>
</tr>
<tr>
<td colspan="2">一般规格</td>
</tr>
<tr>
<td>标称尺寸（高 x 宽 x 长）</td>
<td>4.2&#8243; x 3.0&#8243; x 1.1&#8243; (106 mm x 76 mm x 28 mm)</td>
</tr>
<tr>
<td>标称重量</td>
<td>0.31 磅（0.14 千克）</td>
</tr>
</tbody>
</table>
<p>*附注：<br />
<em>1) EF-TRC 输出<br />
2) EF 测量设备之间可能存在差异，但 EF 合规性的置信因数可能为 95%</em></p>
<p><em>相关阅读：</em></p>
<h3><span style="color: #ff0000;">相关文章：</span></h3>
<h3><span style="color: #ff0000;"><strong><a href="http://www.faxytech.com/archives/what-is-ef.html">环形通量 —它是什么？</a></strong></span></h3>
<h3><strong><a href="http://www.faxytech.com/archives/ef-2.html">如何通过环形通量提高多模测试准确性</a></strong></h3>
<h3><span style="color: #ff0000;"><strong><a href="http://www.faxytech.com/archives/ef.html">光纤环型通量 (EF) 测量白皮书</a></strong></span></h3>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dtx-efm2.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
