<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; TCL</title>
	<atom:link href="http://www.faxytech.com/tag/tcl/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>横向转换损耗(TCL)和等电平横向转换转移损耗(ELTCTL) -FLUKE DSX2-8000/DSX2-5000参数近端衰减不平衡远端衰减不平衡</title>
		<link>http://www.faxytech.com/archives/tcl-eltctl.html</link>
		<comments>http://www.faxytech.com/archives/tcl-eltctl.html#comments</comments>
		<pubDate>Mon, 11 May 2020 06:59:44 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[ELTCTL]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[TCL]]></category>
		<category><![CDATA[横向转换损耗]]></category>
		<category><![CDATA[等电平横向转换转移损耗]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11473</guid>
		<description><![CDATA[本期我们将讲解两个反映线缆抗干扰能力的重要参数，这两个参数分别是：TCL横向转换损耗和ELTCTL等电平横向转换转移损耗。 TCL横向转化损耗(又名：近端衰减不平衡），ELTCL远端横向转化损耗(... ]]></description>
			<content:encoded><![CDATA[<p>本期我们将讲解两个反映线缆抗干扰能力的重要参数，这两个参数分别是：<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/tcl" title="查看 TCL 的全部文章" target="_blank">TCL</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%a8%aa%e5%90%91%e8%bd%ac%e6%8d%a2%e6%8d%9f%e8%80%97" title="查看 横向转换损耗 的全部文章" target="_blank">横向转换损耗</a></span>和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/eltctl" title="查看 ELTCTL 的全部文章" target="_blank">ELTCTL</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%ad%89%e7%94%b5%e5%b9%b3%e6%a8%aa%e5%90%91%e8%bd%ac%e6%8d%a2%e8%bd%ac%e7%a7%bb%e6%8d%9f%e8%80%97" title="查看 等电平横向转换转移损耗 的全部文章" target="_blank">等电平横向转换转移损耗</a></span>。</p>
<p>TCL横向转化损耗(又名：近端<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>不平衡），ELTCL远端横向转化损耗(又名：远端衰减不平衡）</p>
<p>在讲这两个参数之前，我们先需要思考一个基本问题，为什么用双绞线传输信号？</p>
<p>&nbsp;</p>
<p>其实，双绞线才是真正的平衡传输线。为什么呢？大家在下图中可以看到，中间的表示为辐射干扰源，左边的为平行线示意。由于距离干扰源更近一点，蓝色线对中的实线芯线，将比虚线“积累”更多的干扰能量，我们用红色点代表干扰能量。我们注意到，蓝色实线上的红点“个头”略大，蓝色虚线上的红点个头则略小，这就造成线对末端的两根线上的干扰能量强度，积累后出现明显的“差信号”。 而右边的为改进性能而设计的双绞线，蓝色实线B和蓝色虚线A由于经常相对于干扰辐射源距离远近实现“换位”，即轮番靠近，交替远离。因此线对末端积累的差信号几乎为零，当然前提是线对完全对称，且绞结率足够高。以上就是双绞线能抵消外来干扰的原理。</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/05/TCL.png" class="highslide-image" onclick="return hs.expand(this);"><img class="aligncenter size-full wp-image-11474" title="FLUKE TCL参数" src="http://www.faxytech.com/wp-content/uploads/2020/05/TCL.png" alt="FLUKE TCL参数" width="599" height="390" /></a></p>
<p>&nbsp;</p>
<p>为了让双绞线具有良好的抗干扰能力，首先两根双绞线的长度完全相等，特别是在传输高频信号时；其次，双绞线对的材质和结构尽量均匀、对称。这被称作传输线的平衡性能。传统的考察平衡性的参数有<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>/FEXT，即<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>和远端串扰和 ANEXT/AFEXT，也就是外部近端串扰和外部远端串扰。这些参数主要考察不平衡造成的“线对间干扰”和“缆间干扰”。</p>
<p>&nbsp;</p>
<p>我们这里主要关注的是近端干扰，主要来源于线缆内和线缆间。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/tcl-eltctl.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>为单对以太网进入企业应用场景做好准备</title>
		<link>http://www.faxytech.com/archives/single-pair.html</link>
		<comments>http://www.faxytech.com/archives/single-pair.html#comments</comments>
		<pubDate>Wed, 27 Nov 2019 09:39:22 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[10BASE-T1L]]></category>
		<category><![CDATA[10BASE-T1S]]></category>
		<category><![CDATA[ANSI/TIA-568.0-D-2]]></category>
		<category><![CDATA[ELTCL]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[PSAACRF]]></category>
		<category><![CDATA[PSANEXT]]></category>
		<category><![CDATA[TCL]]></category>
		<category><![CDATA[传播延迟]]></category>
		<category><![CDATA[回波损耗、插入损耗]]></category>
		<category><![CDATA[横向变换损耗]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[等水平横向变换传输损耗]]></category>
		<category><![CDATA[综合外部近端串扰]]></category>
		<category><![CDATA[综合外部远端串扰]]></category>
		<category><![CDATA[综合远端外部衰减串扰比]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11204</guid>
		<description><![CDATA[或许你已经注意到，最近市场上出现了一些有关单对以太网的话题，同时，一些旨在支持10Mb/s以太网的新标准也正在制定之中。如果你觉得10Mb/s听上去很古董，其实你并不是唯一持有这种看法... ]]></description>
			<content:encoded><![CDATA[<p>或许你已经注意到，最近市场上出现了一些有关单对以太网的话题，同时，一些旨在支持10Mb/s以太网的新标准也正在制定之中。如果你觉得10Mb/s听上去很古董，其实你并不是唯一持有这种看法的人。毕竟，10BASE-T诞生于上世纪90年代，而且即使时至今日，也鲜有局域网以此作为信号速率。但这次的情况却有所不同。各类低速、窄带物联网设备为10Mb/s开启了通往无尽可能的应用场景的大门——这些设备全部运行于单对以太网。</p>
<p>IEEE P802.3cg 10Mb/s单对以太网特别工作小组正在有条不紊地开发着<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/10base-t1s" title="查看 10BASE-T1S 的全部文章" target="_blank">10BASE-T1S</a></span>（短程）和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/10base-t1l" title="查看 10BASE-T1L 的全部文章" target="_blank">10BASE-T1L</a></span>（长程）标准，以支持单对以太网10Mb/s传输速率。这些标准计划于今年发布。事实上，我们已经有了一些单对以太网标准，例如在汽车行业中分别支持15米和40米有效传输距离的100BASE-T1（802.3bw）和1000BASE-T1（802.3bp）规范。面向汽车和工业应用，支持至少15米10Mb/s有效传输距离的10BASE-T1S标准也是可以用于替代传统现场总线通信协议的一个颇具吸引力的选择。但在10Mb/s单对以太网中支持至少一千米的有效传输距离，这或许能够改变连接低速物联网设备的方式，例如在暖通空调、安保和照明控制应用场景中使用的传感器、制动器和继电器，最终进入商业企业空间。</p>
<p>&nbsp;</p>
<p><strong>我们为什么需要它？</strong></p>
<p>根据不同的应用场景，我们可以在各种协议、媒介、导体截面和连接器类型中找到用于机器对机器（M2M）通讯的低速现场总线。终端单元连接目前是控制器和设备最广泛采用的连接方式，例如用于探测<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>、湿度、压力或其他环境因素的感应器，或控制阀门或诸如开关之类的继电器等致动器设备。</p>
<p>鉴于使用场景如此纷繁复杂，10BASE-T1S和10BASE-T1L被制定出来用于为这些系统提供互通性，让它们能够在标准化的通用布线系统和协议上运行，最终达到取消专有接口和线缆的目的。而10BASE-T1L也为完成设备与运行于传统局域网的系统之间的整合铺平了道路。</p>
<p>那么，为什么不继续使用当前已有的四对线缆10BASE-T标准呢？答案很简单——因为它们不需要。既然这些低速设备只需要一对线缆，所以通过去除无用线缆线对将成本降至最低，并且让线缆和连接器的整体尺寸保持最小，自然是合理的选择。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>有何区别？</strong></p>
<p>不同于传统的10BASE-T应用，10BASE-T1L将允许最多接入10个直插式连接器。这种应用也将容纳被称之为“混合段”的线缆配置。相比于传统的链接段，混合段（有时也被称作多分支）能够在一个信道中支持超过两台设备。尽管我们尚不清楚如何利用这种配置，但预计一些商用企业空间中的建筑自动化系统或许可以发挥出这种配置的优势。</p>
<p>&nbsp;</p>
<p>10BASE-T1L也将计划为其所连接的低速设备提供远程供电支持。这些设备同我们在今天的PoE技术中所看到的一样，但不兼容一类、二类、三类和四类两对和四对线缆，因为这属于单对应用。802.3bu协议，即数据线供电（PoDL）标准旨在为单对线缆传输最高13.6瓦的电力提供支持。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>相同点是什么？</strong></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2019/11/ANSITIA-568-0-D-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11205" title="ANSITIA-568-0-D-2" src="http://www.faxytech.com/wp-content/uploads/2019/11/ANSITIA-568-0-D-2.jpg" alt="" width="507" height="167" /></a></p>
<p>与其他IEEE企业应用类似，10BASE-T1L将受到目前正在起草中的TIA和ISO/IEC商业布线标准的支持。对于其他商业企业环境，<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ansitia-568-0-d-2" title="查看 ANSI/TIA-568.0-D-2 的全部文章" target="_blank">ANSI/TIA-568.0-D-2</a></span> 单平衡双绞线用例和拓扑以及ANSI/TIA-568.5单平衡双绞线布线和组件标准已进入开发状态，ISO/IEC也在制定用于定义性能参数的文档。</p>
<p>&nbsp;</p>
<p>ANSI/TIA-568.5将列明多信道配置以及不同距离限制和带宽，包括一千米的10个连接器和更令人期盼的100米的四连接器配置。当其成为企业单对局域网通用支持的选择后，预期会取得快速发展。</p>
<p>&nbsp;</p>
<p>568.5标准也将包括针对现场测试仪规格的规范要求。现场测试仪将通过我们熟悉的各种性能参数，例如<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>、<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>、综合外部<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>（<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/psanext" title="查看 PSANEXT 的全部文章" target="_blank">PSANEXT</a></span>）、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%bb%bc%e5%90%88%e5%a4%96%e9%83%a8%e8%bf%9c%e7%ab%af%e4%b8%b2%e6%89%b0" title="查看 综合外部远端串扰 的全部文章" target="_blank">综合外部远端串扰</a></span>（<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/psaacrf" title="查看 PSAACRF 的全部文章" target="_blank">PSAACRF</a></span>）、综合远端外部<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>串扰比（PSAACRF）、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%a8%aa%e5%90%91%e5%8f%98%e6%8d%a2%e6%8d%9f%e8%80%97" title="查看 横向变换损耗 的全部文章" target="_blank">横向变换损耗</a></span>（<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/tcl" title="查看 TCL 的全部文章" target="_blank">TCL</a></span>）、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%ad%89%e6%b0%b4%e5%b9%b3%e6%a8%aa%e5%90%91%e5%8f%98%e6%8d%a2%e4%bc%a0%e8%be%93%e6%8d%9f%e8%80%97" title="查看 等水平横向变换传输损耗 的全部文章" target="_blank">等水平横向变换传输损耗</a></span>（<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/eltcl" title="查看 ELTCL 的全部文章" target="_blank">ELTCL</a></span>）和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e4%bc%a0%e6%92%ad%e5%bb%b6%e8%bf%9f" title="查看 传播延迟 的全部文章" target="_blank">传播延迟</a></span>等，来检测安装完成的单对线缆的性能。<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>网络早已通过参与标准制订委员会，并与生产商合作，共同开发相关网络组件的方式，为这些新兴应用做好了准备。</p>
<p>&nbsp;</p>
<p>正如我们在以往标准制定过程中所做出的努力，如8类线标准制定等，你可以放心的是，我们将继续走在标准开发的前沿，并在开始部署系统时，全力为企业环境中的单对以太网应用测试提供支持。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/single-pair.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>ELTCTL(Equal Level TCTL) 两端等效横向转换损耗</title>
		<link>http://www.faxytech.com/archives/eltctl.html</link>
		<comments>http://www.faxytech.com/archives/eltctl.html#comments</comments>
		<pubDate>Fri, 14 Apr 2017 02:50:12 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[ELTCTL]]></category>
		<category><![CDATA[TCL]]></category>
		<category><![CDATA[两端等效横向转换损耗]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8753</guid>
		<description><![CDATA[ELTCTL (Equal Level Transverse Conversion Transfer Loss) – 两端等效横向转换损耗，TCL(Transverse Conversion Loss）-横向转换损耗 2017年，ELTCTL开始被大家关注是因为GB/T50312-2016里面有介绍，那么ELTCTL是什么含义... ]]></description>
			<content:encoded><![CDATA[<p id="article-title"><strong><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/eltctl" title="查看 ELTCTL 的全部文章" target="_blank">ELTCTL</a></span></strong> (Equal Level Transverse Conversion Transfer Loss) –<strong> <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e4%b8%a4%e7%ab%af%e7%ad%89%e6%95%88%e6%a8%aa%e5%90%91%e8%bd%ac%e6%8d%a2%e6%8d%9f%e8%80%97" title="查看 两端等效横向转换损耗 的全部文章" target="_blank">两端等效横向转换损耗</a></span></strong>，<strong><strong><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/tcl" title="查看 TCL 的全部文章" target="_blank">TCL</a></span>(Transverse Conversion Loss）-横向转换损耗</strong></strong></p>
<p>2017年，ELTCTL开始被大家关注是因为GB/T50312-2016里面有介绍，那么ELTCTL是什么含义呢，今天连讯达许工为大家科普一下。</p>
<p>测量是通过向双绞线注入差模信号（DM），然后测量同一对双绞线返回的共模信号（CM）。CM信号返回的越少，TCL参数就会越好，越平衡。</p>
<p><img title="TCL(Transverse Conversion Loss）横向转换损耗" src="http://www.faxytech.com/wp-content/uploads/2014/03/tcl.png" alt="" width="456" height="239" /></p>
<p><strong>TCL(Transverse Conversion Loss）横向转换损耗</strong></p>
<p>如果你觉得它像是<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>的测试，那你就说对了。回波损耗测试是通过向双绞线注入DM（差模信号）然后测试返回的DM信号，然而TCL是测试CM信号。</p>
<p>横向变换传输损耗 (TCTL) 是在同一双绞线内异端测量的模式转换。如下图所示，其测量方式是在双绞线中注入一个差模信号，然后测量同一双绞线上另一端的共模信号。因为共模信号的量取决于长度，所以必须通过均等化将<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>考虑在内。因此更有意义的测量是等水平 TCTL (ELTCTL)。与 TCL 类似，远端共模信号越小，平衡就越好。</p>
<p>就和 TCL 类似回波损耗测量一样，ELTCTL 与插入损耗测量类似。但是，插入损耗测量的是远端的差模信号，而 ELTCTL 测量的是远端的共模信号 (TCTL)，然后根据插入损耗应用均等化以获得 ELTCTL 测量结果。</p>
<p><a href="http://dsx5000.faxytech.com/wp-content/uploads/2014/11/dsx5000-tcl.jpg" class="highslide-image" onclick="return hs.expand(this);"><img title="ELTCTL（两端等效横向转换损耗）" src="http://dsx5000.faxytech.com/wp-content/uploads/2014/11/dsx5000-tcl.jpg" alt="ELTCTL（两端等效横向转换损耗）" width="463" height="245" /></a></p>
<p><strong>ELTCTL（两端等效横向转换损耗）</strong></p>
<p>参考阅读：</p>
<p><a href="http://www.faxytech.com/archives/dsx5000-tcl-eltctl.html">福禄克DSX-8000与DSX-5000如何测试TCL与ELTCTL</a></p>
<p>链接：<a href="http://www.faxytech.com/archives/dsx5000-tcl-eltctl.html">http://www.faxytech.com/archives/dsx5000-tcl-eltctl.html</a></p>
<p><a href="http://dsx5000.faxytech.com/dsx5000-banlance/">为什么要测试平衡参数特性？</a></p>
<p>链接：<a href="http://dsx5000.faxytech.com/dsx5000-banlance/">http://dsx5000.faxytech.com/dsx5000-banlance/</a></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/eltctl.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>fluke DSX-5000中TCL与ELTCTL是什么意思？测试不过怎么办？</title>
		<link>http://www.faxytech.com/archives/dsx5000-tcl-eltctl.html</link>
		<comments>http://www.faxytech.com/archives/dsx5000-tcl-eltctl.html#comments</comments>
		<pubDate>Wed, 19 Mar 2014 08:45:12 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX-5000]]></category>
		<category><![CDATA[ELTCTL]]></category>
		<category><![CDATA[ELTCTL测试不过]]></category>
		<category><![CDATA[TCL]]></category>
		<category><![CDATA[TCL是什么意思]]></category>
		<category><![CDATA[TCL测试不过]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=3623</guid>
		<description><![CDATA[福禄克DSX-5000中国区代理深圳市连讯达电子技术开发有限公司福禄克网络部工程师为大家TCL与ELTCTL两个参数的意思。(PS:这是DTX-1800里面没有的参数） transverse conversion loss &#160;TCL 横向变换损耗 tra... ]]></description>
			<content:encoded><![CDATA[<p>
	福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>中国区代理深圳市连讯达电子技术开发有限公司福禄克网络部工程师为大家<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/tcl" title="查看 TCL 的全部文章" target="_blank">TCL</a></span>与<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/eltctl" title="查看 ELTCTL 的全部文章" target="_blank">ELTCTL</a></span>两个参数的意思。(PS:这是<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>里面没有的参数）
</p>
<p>
	transverse conversion loss &nbsp;TCL 横向变换损耗<br />
	transverse conversion transfer loss &nbsp;TCTL 横变换转移损耗<br />
	TCL (Transverse Conversion Loss) &#8211; DSX CableAnalyzer TCL is one of two balance measurements found in ANSI/TIA-568-C.2, ANSI/TIA-1005 and ISO/IEC 11801:2010. The other is ELTCTL.
</p>
<p>
	<br />
	The measurement is made by injecting a differential mode signal (DM) into a twisted pair, then measuring the common mode signal (CM) returned on that same twisted pair. The smaller the CM signal returned, the better the TCL measurement (balance).<br />
	&nbsp;<br />
	翻译：测量是通过向双绞线注入差模信号（DM），然后测量同一对双绞线返回的共模信号（CM）。CM信号返回的越少，TCL参数就会越好，越平衡。
</p>
<p class="p0" style="margin-bottom: 0pt; margin-top: 0pt; line-height: 15pt; background-position: initial initial; background-repeat: initial initial;">
	<span style="color: rgb(68, 68, 68); font-size: 10.5pt; font-family: Arial; background-position: initial initial; background-repeat: initial initial;"><o:p></o:p></span>
</p>
<p>
	<a href="http://www.faxytech.com/wp-content/uploads/2014/03/tcl.png" class="highslide-image" onclick="return hs.expand(this);" rel="" style="" target="" title=""><img alt="" class="alignnone size-full wp-image-3624" height="299" src="http://www.faxytech.com/wp-content/uploads/2014/03/tcl.png" style="" title="tcl" width="570" /></a>
</p>
<p>
	If it looks similar to a Return Loss measurement, you&#39;re right. Except a Return Loss measurement is made by injecting a DM signal into the pair and measuring the DM signal returned. Here we are measuring the CM signal returned which is TCL.
</p>
<p>
	翻译：如果你觉得它像是<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>的测试，那你就说对了。回波损耗测试是通过向双绞线注入DM（差模信号）然后测试返回的DM信号，然而TCL是测试CM信号。
</p>
<p>
	Field test requirements for ANSI/TIA-568-C.2 are deferred to ANSI/TIA-1152. At this time, TCL is not a field test requirement because until the DSX CableAnalyzer came along, no field test equipment vendor could perform a TCL field test. It is anticipated that other test equipment vendors will eventually offer TCL field measurements too. Field testers are normally capable of DM measurements only &#8211; the DSX CableAnalyzer is capable of both DM and CM measurements, hence its ability to measure TCL and ELTCTL.
</p>
<p>
	翻译：对于ANSI/TIA-568-C.2现场测试要求直到ANSI/TIA-1152标准。在那个时候，TCL并不是一个现场测试的要求，因为没有现场测试设备供应商可以执行TCL现场测试，直到<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx-5000" title="查看 DSX-5000 的全部文章" target="_blank">DSX-5000</a></span>电缆认证分析仪的诞生。预计其他品牌测试设备厂家最终也将提供TCL现场测量。现场测试人员通常仅能DM测量 &#8211; 对DSX-5000电缆认证分析仪能够既DM和CM的测量，因此其有测量TCL与ELTCTL的能力。
</p>
<p>
	If you wish to add TCL and ELTCTL to your standard Category 5e, 6, 6A or Class D, E or EA test, select your test limit under the folder in DSX called Balance Measurements and look for your test limit with a suffix of (+TCL):
</p>
<p>
	翻译：如果需要对于Cat5e，Cat6，Cat 6A测试TCL和ELTCTL参数，你只需要再DSX-5000 的文件夹下面找到+TCL的后缀就可以了。
</p>
<p>
	<a href="http://www.faxytech.com/wp-content/uploads/2014/03/TCL1.png" class="highslide-image" onclick="return hs.expand(this);" rel="" style="" target="" title=""><img alt="" class="alignnone size-full wp-image-3626" height="256" src="http://www.faxytech.com/wp-content/uploads/2014/03/TCL1.png" style="" title="横向变换损耗" width="192" /></a>&nbsp;<a href="http://www.faxytech.com/wp-content/uploads/2014/03/TCL2.png" class="highslide-image" onclick="return hs.expand(this);" rel="" style="" target="" title=""><img alt="" class="alignnone size-full wp-image-3627" height="256" src="http://www.faxytech.com/wp-content/uploads/2014/03/TCL2.png" style="" title="横向变换损耗" width="192" /></a>&nbsp;<a href="http://www.faxytech.com/wp-content/uploads/2014/03/TCL3.png" class="highslide-image" onclick="return hs.expand(this);" rel="" style="line-height: 1.6em;" target="" title=""><img alt="" class="alignnone size-full wp-image-3625" height="256" src="http://www.faxytech.com/wp-content/uploads/2014/03/TCL3.png" style="opacity: 0.9;" title="横向变换损耗" width="192" /></a>
</p>
<p>
	This will add &asymp; 6.6 seconds to your AUTOTEST time.<br />
	TCL测试将增加6.6秒测试时间。<br />
	The suffix of (+TCL) indicates a standard ANSI/TIA or ISO/IEC test with the addition of TCL and ELTCTLmeasurements. ANSI/TIA-568-C.2 and ISO/IEC 11801:2010 only provide test limits for Channel measurements at this time. If you select a Perm. Link test limit, the TCL and ELTCTL measurements will be performed, but there will be no PASS/FAIL criteria applied. You will also see the Industrial Ethernet standards TIA 1005 with the different E1, E2 and E3 environmental TCL and ELTCTL limits.
</p>
<p>
	翻译：有（+TCL）后缀的预示着ANSI/TIA或者ISO/IEC测试有这个规格。 目前ANSI/TIA-568-C.2 and ISO/IEC 11801:2010 仅仅提供信道测试的极限值，如果选择永久链路测试，TCL和ELTCTL也会被执行，但是不会有通过/失败的标准。同样你也会看到工业以太网标准TIA 1005 ，E1,E2,E3的标准的限制。<br />
	&nbsp;<br />
	In the example below from a DSX-5000 CableAnalyzer, a Category 6A Channel was tested. With a margin of 5.4 dB (6 dB is a factor of 2), you can feel confident that this link will perform well, even in a noisy environment.<br />
	翻译：从下面DSX-5000的例子中可以看到，Cat 6A通道测试有5.4db的余量，你就不用担心了，因为这条链路表现非常好。即使在有噪音的环境下。
</p>
<p class="p0" style="margin-bottom:0pt; margin-top:0pt; ">
	<a href="http://www.faxytech.com/wp-content/uploads/2014/03/tcl4.png" class="highslide-image" onclick="return hs.expand(this);"><img alt="" class="alignnone size-full wp-image-3628" height="320" src="http://www.faxytech.com/wp-content/uploads/2014/03/tcl4.png" title="tcl4" width="297" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx5000-tcl-eltctl.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
