		<item>
		<title>【3dB 原则】RL 通过？失败？ &#8211; 数据电缆测试入门和常见测试问题解答</title>
		<link>http://www.faxytech.com/archives/3db-rule-rl.html</link>
		<comments>http://www.faxytech.com/archives/3db-rule-rl.html#comments</comments>
		<pubDate>Fri, 08 Sep 2017 05:43:22 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[3DB原则]]></category>
		<category><![CDATA[Return Loss]]></category>
		<category><![CDATA[RL]]></category>
		<category><![CDATA[回拨损耗]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=9254</guid>
		<description><![CDATA[【3dB 原则】RL 通过？失败？?如果一条链路测得的衰减值不大，这通常意味着这条链路不长，传过来的信号较强。那么，此时即便回波信号较强，信噪比 S/N 也不会太低，接收端仍能很好地分辨... ]]></description>
			<content:encoded><![CDATA[<p>【3dB 原则】<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/rl" title="查看 RL 的全部文章" target="_blank">RL</a></span> 通过？失败？?如果一条链路测得的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>值不大，这通常意味着这条链路不长，传过来的信号较强。那么，此时即便回波信号较强，信噪比 S/N 也不会太低，接收端仍能很好地分辨出信号。所以，当你发现测试的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>值超标但测试结果却标示为“通过”时，就是 3dB 原则在起作用了(3dB 损耗大约对应 10-15 米线对长度)。国际标准 ISO11801 和 TIA568C 都对此做了规定。此规定偏向于布线产品供应商。简单地说就是：链路短即便回波强也不怕。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/3db-rule-rl.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克DTX1800测试RL损耗损耗不过奇怪状况</title>
		<link>http://www.faxytech.com/archives/dtx1800-rl.html</link>
		<comments>http://www.faxytech.com/archives/dtx1800-rl.html#comments</comments>
		<pubDate>Thu, 14 Aug 2014 01:23:44 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DTX1800故障]]></category>
		<category><![CDATA[fluke维修]]></category>
		<category><![CDATA[RL]]></category>
		<category><![CDATA[回波损耗]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=4470</guid>
		<description><![CDATA[客户问：Fluke DTX-1800正常测试情况下，出现如下问题：测试一根线RL不良之后，接着后面测试的线均不良，将测试仪的适配器拔出再插上继续进行测试，前面那根不良线又测试OK了，但测试一段... ]]></description>
			<content:encoded><![CDATA[<p>客户问：Fluke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>正常测试情况下，出现如下问题：测试一根线<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/rl" title="查看 RL 的全部文章" target="_blank">RL</a></span>不良之后，接着后面测试的线均不良，将测试仪的适配器拔出再插上继续进行测试，前面那根不良线又测试OK了，但测试一段时间又会出现同样的问题。请问有可能是什么原因？</p>
<p><strong>福禄克资深工程师回答：</strong>该换插座了，另外检查一下是否已经多次更换过插座，一般支持更换20-30次（依使用的野蛮程度定）。</p>
<p>客户问：没有那么多 ，最多换过3-5次</p>
<p><strong>福禄克资深工程师回答：</strong>如果只有3-5次，可以先看看适配器与机器借口是否有松动，打开<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克DTX 1800">DTX1800</a></span>适配器看看插座接口是否有松动，打开适配器还是要注意防静电的，南方用户这个季节可忽略静电问题。（夏季）</p>
<p>客户问：1、跳线测试和通道测试均出现上面所说的现象；2、其中跳线测试有换过很5、6次JACK，通道测试没有换过JACK；3、适配器与机器接口未见到有松动。请问还有什么故障可嫌疑的吗？</p>
<p><strong>福禄克资深工程师回答：</strong>1。被测链路/跳线有多长?短链路不要用通道适配器进行测试。2。(拆开)<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-patchcord-adapter.html" title="跳线适配器">跳线适配器</a></span>Jack基座检查否？有无松动？</p>
<p>大家可以尝试以上方法自己排除问题，如果还不能解决请联系连讯<span class='wp_keywordlink'><a href="http://www.faxytech.com/fluke-maintenance" title="福禄克维修">福禄克维修</a></span>中心。</p>
]]></content:encoded>