		<item>
		<title>福禄克FLUKE FIBR-1-SHOTPRO项目招标参数</title>
		<link>http://www.faxytech.com/archives/fibr-1-shotpro-tech.html</link>
		<comments>http://www.faxytech.com/archives/fibr-1-shotpro-tech.html#comments</comments>
		<pubDate>Mon, 23 Nov 2015 00:33:45 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[FIBR-1-SHOTPRO]]></category>
		<category><![CDATA[技术参数]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7007</guid>
		<description><![CDATA[1、标准技术参数表 光纤故障测试仪应符合本招标文件技术规范通用部分的要求。 投标人应认真逐项填写标准技术参数表中投标人保证值，不能空格，也不能以“响应”两字代替，不允许改动... ]]></description>
			<content:encoded><![CDATA[<h4>1、标准<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%8a%80%e6%9c%af%e5%8f%82%e6%95%b0" title="查看 技术参数 的全部文章" target="_blank">技术参数</a></span>表</h4>
<p>光纤故障测试仪应符合本招标文件技术规范通用部分的要求。</p>
<p>投标人应认真逐项填写标准技术参数表中投标人保证值，不能空格，也不能以“响应”两字代替，不允许改动招标人要求值。如有偏差，请填写技术偏差表。</p>
<p>光纤故障测试仪的技术参数应符合表1的要求。</p>
<p>填写以下表格注意事项：其中“项目单位填写”的部分由各项目单位根据工程实际情况和需要必须全面认真填写；空白部分的参数根据需要选择填写，不需要填写的应以“—”表示。</p>
<p>表1??技术参数响应表</p>
<table align="center">
<tbody>
<tr>
<td width="242" valign="center">项　　目</td>
<td width="76" valign="center">单??位</td>
<td width="118" valign="center">招标人要求值</td>
<td width="118" valign="center">投标人保证值</td>
</tr>
<tr>
<td width="242" valign="center">制造厂（商）</td>
<td colspan="3" width="313" valign="center">Fluke测试仪器（上海）有限公司</td>
</tr>
<tr>
<td width="242" valign="center">原产地</td>
<td colspan="3" width="313" valign="center">美国</td>
</tr>
<tr>
<td width="242" valign="center">产品型号规格</td>
<td colspan="3" width="313" valign="center"><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html" title="福禄克Fluke FIBR-1-SHOTPRO">FIBR-1-SHOTPRO</a></span></td>
</tr>
<tr>
<td width="242" valign="center">工作方式</td>
<td width="76" valign="center">&nbsp;</td>
<td width="118" valign="center">手持式</td>
<td width="118" valign="center">（投标人填写）</td>
</tr>
<tr>
<td width="242" valign="center">仪器功能</td>
<td width="76" valign="center">&nbsp;</td>
<td width="118" valign="center">总体功能：1、?分析长达?15?英里（超过?23000?米）的光纤链路；</p>
<p>2、?可在?5?秒内分析光纤链路，平均工作时间减少多达?30%；</p>
<p>3、?定位高损耗事件，取消使用试错法，查找单模光纤上的最常见故障；</p>
<p>4、?定位反射事件，允许用户分析信道；</p>
<p>5、?定位光纤断裂情况，允许用户快速隔离断裂和故障，无需解释复杂图形；</p>
<p>6、?定位多个事件/故障，允许用户“查看”信道中的所有事件。</td>
<td width="118" valign="center">（投标人填写）</td>
</tr>
<tr>
<td width="242" valign="center">光波长度</td>
<td width="76" valign="center">nm</td>
<td width="118" valign="center">25?C?时：1550±?20</td>
<td width="118" valign="center">（投标人填写）</td>
</tr>
<tr>
<td width="242" valign="center">激光类别</td>
<td width="76" valign="center">&nbsp;</td>
<td width="118" valign="center">CDRH?1?类</p>
<p>符合?EN?60825-2?标准</td>
<td width="118" valign="center">（投标人填写）</td>
</tr>
<tr>
<td width="242" valign="center">所测光纤类型</td>
<td width="76" valign="center">&nbsp;</td>
<td width="118" valign="center">9/125??单模</td>
<td width="118" valign="center">（投标人填写）</td>
</tr>
<tr>
<td width="242" valign="center">认证和合规性</td>
<td width="76" valign="center">&nbsp;</td>
<td width="118" valign="top">符合相关的欧盟标准；</p>
<p>符合相关的澳大利亚标准；通过加拿大标准会?CSA?C22.2?No.?61010.1.04?的认证；符合?FCC?规则?A?部分?A?类要求</td>
<td width="118" valign="center">&nbsp;</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<h4>2　项目需求部分</h4>
<p>2.1　货物需求及供货范围</p>
<p>表2??货物需求及供货范围一览表</p>
<table>
<tbody>
<tr>
<td rowspan="3" width="33" valign="center">序号</td>
<td rowspan="3" width="130" valign="center">仪器仪表名称</td>
<td rowspan="3" width="36" valign="center">单位</td>
<td colspan="4" width="211" valign="center">招标单位要求</td>
<td colspan="4" width="215" valign="center">投标人响应</td>
</tr>
<tr>
<td rowspan="2" width="53" valign="center">产品型号</td>
<td rowspan="2" width="30" valign="center">数量</td>
<td colspan="2" width="127" valign="center">技术参数</td>
<td rowspan="2" width="50" valign="center">产品型号</td>
<td rowspan="2" width="29" valign="center">数量</td>
<td colspan="2" width="135" valign="center">技术参数</td>
</tr>
<tr>
<td width="68" valign="center">光波长度</td>
<td width="59" valign="center">所测光纤类型</td>
<td width="69" valign="center">光波长度</td>
<td width="66" valign="center">所测光纤类型</td>
</tr>
<tr>
<td width="33" valign="center">1</td>
<td width="130" valign="center">光纤故障测试仪</td>
<td width="36" valign="center">台</td>
<td width="53" valign="center"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fibr-1-shotpro" title="查看 FIBR-1-SHOTPRO 的全部文章" target="_blank">FIBR-1-SHOTPRO</a></span></td>
<td width="30" valign="center">1</td>
<td width="68" valign="center">25?C?时：1550±?20?nm</td>
<td width="59" valign="center">9/125?单模</td>
<td width="50" valign="center">&nbsp;</td>
<td width="29" valign="center">&nbsp;</td>
<td width="69" valign="center">&nbsp;</td>
<td width="66" valign="center">&nbsp;</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>2.2　使用条件</p>
<p>表3??使??用　条　件</p>
<table align="center">
<tbody>
<tr>
<td width="29" valign="center">序号</td>
<td width="262" valign="center">项????目</td>
<td width="262" valign="center">内????容</td>
</tr>
<tr>
<td width="29" valign="center">1</td>
<td width="262" valign="center">电池工作<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span></td>
<td width="262" valign="center">0?C?～?50?C</td>
</tr>
<tr>
<td width="29" valign="center">2</td>
<td width="262" valign="center">电池非工作温度</td>
<td width="262" valign="center">-20?C?～?60?C</td>
</tr>
<tr>
<td width="29" valign="center">3</td>
<td width="262" valign="center">工作湿度</td>
<td width="262" valign="center">95%?(10?C?～?35?C)，无凝露，不受控制?&lt;10??C</td>
</tr>
<tr>
<td width="29" valign="center">4</td>
<td width="262" valign="center">工作环境</td>
<td width="262" valign="center">无腐蚀性气体</td>
</tr>
</tbody>
</table>
<p>2.3　项目单位技术差异表</p>
<p>项目单位要求的产品技术规范应完全符合本招标文件中规定。若有特殊要求，项目单位应如实、认真地在技术差异表中填写差异值，否则视为与本招标文件中规定的要求一致。若无技术差异，则应在表4中填写“无差异”。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>表4??项目单位技术差异表</p>
<table align="center">
<tbody>
<tr>
<td width="29" valign="center">序号</td>
<td width="131" valign="center">项????目</td>
<td width="131" valign="center">标准参数值</td>
<td width="131" valign="center">项目单位要求值</td>
<td width="131" valign="center">投标人保证值</td>
</tr>
<tr>
<td width="29" valign="center">1</td>
<td width="131" valign="center">光纤故障测试仪</td>
<td width="131" valign="center">无差异</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">2</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">&nbsp;</td>
<td width="131" valign="center">……</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">序号</td>
<td width="131" valign="center">项????目</td>
<td width="131" valign="center">变更条款页码、款号</td>
<td width="131" valign="center">原表达</td>
<td width="131" valign="center">变更后表达</td>
</tr>
<tr>
<td width="29" valign="center">1</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">2</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">&nbsp;</td>
<td width="131" valign="center">……</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
<td width="131" valign="center">&nbsp;</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4>3　投标人响应部分</h4>
<p>3.1　技术偏差</p>
<p>投标人提供的产品技术规范应与本招标文件中规定的要求一致。若有偏差，投标人应如实、认真地填写偏差值；若无技术偏差，则视为完全满足本技术规范的要求，在投标人技术偏差表（见表5）中注明“无偏差”。</p>
<p>表5??投标人技术偏差表</p>
<table align="center">
<tbody>
<tr>
<td width="29" valign="center">序号</td>
<td width="105" valign="center">项????目</td>
<td width="105" valign="center">对应条款编号</td>
<td width="105" valign="center">技术规范要求</td>
<td width="105" valign="center">偏????差</td>
<td width="105" valign="center">备????注</td>
</tr>
<tr>
<td width="29" valign="center">1</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">2</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">3</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">4</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">5</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="29" valign="center">&nbsp;</td>
<td width="105" valign="center">……</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
<td width="105" valign="center">&nbsp;</td>
</tr>
</tbody>
</table>
<p>3.2　投标人应提供的技术资料</p>
<p>表6　投标人应提供的技术资料</p>
<table align="center">
<tbody>
<tr>
<td width="28" valign="center">序号</td>
<td width="263" valign="center">内??????容</td>
<td width="263" valign="center">投标人响应情况</td>
</tr>
<tr>
<td width="28" valign="center">1</td>
<td width="263" valign="center">&nbsp;</td>
<td width="263" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="28" valign="center">2</td>
<td width="263" valign="center">&nbsp;</td>
<td width="263" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="28" valign="center">3</td>
<td width="263" valign="center">&nbsp;</td>
<td width="263" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="28" valign="center">4</td>
<td width="263" valign="center">&nbsp;</td>
<td width="263" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="28" valign="center">5</td>
<td width="263" valign="center">&nbsp;</td>
<td width="263" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="28" valign="center">6</td>
<td width="263" valign="center">&nbsp;</td>
<td width="263" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="28" valign="center">7</td>
<td width="263" valign="center">&nbsp;</td>
<td width="263" valign="center">&nbsp;</td>
</tr>
</tbody>
</table>
<p>注??投标人在“投标人响应情况”一栏中填写“是”或“否”。</p>
<p>附　录　A<br />
技术参数通用条款变更表</p>
<table align="center">
<tbody>
<tr>
<td rowspan="2" width="162" valign="center">变更条款页码、款号</td>
<td colspan="2" width="392" valign="center">变??更??内??容</td>
</tr>
<tr>
<td width="196" valign="center">原表述</td>
<td width="196" valign="center">变更后表述</td>
</tr>
<tr>
<td width="162" valign="center">&nbsp;</td>
<td width="196" valign="center">&nbsp;</td>
<td width="196" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="162" valign="center">&nbsp;</td>
<td width="196" valign="center">&nbsp;</td>
<td width="196" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="162" valign="center">&nbsp;</td>
<td width="196" valign="center">&nbsp;</td>
<td width="196" valign="center">&nbsp;</td>
</tr>
<tr>
<td width="162" valign="center">&nbsp;</td>
<td width="196" valign="center">&nbsp;</td>
<td width="196" valign="center">&nbsp;</td>
</tr>
</tbody>
</table>
<p>注??本表是对技术规范通用部分的补充和修改，如有冲突，应以本表为准。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/fibr-1-shotpro-tech.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【福禄克】Fluke Fiber OneShot Pro 单模光纤故障定位仪（FIBR-1-SHOTPRO,FIBR-1-KITPRO,FIBR-1-KITPRO-VF,FIBR-1-KITPRO-PM,FIBR-1-KITPRO-VFPM,FQM-KIT）</title>
		<link>http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html</link>
		<comments>http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html#comments</comments>
		<pubDate>Mon, 29 Aug 2011 09:00:04 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[福禄克光缆测试产品]]></category>
		<category><![CDATA[Fiber OneShot Pro]]></category>
		<category><![CDATA[FIBR-1-KITPRO]]></category>
		<category><![CDATA[FIBR-1-KITPRO-PM]]></category>
		<category><![CDATA[FIBR-1-KITPRO-VF]]></category>
		<category><![CDATA[FIBR-1-KITPRO-VFPM]]></category>
		<category><![CDATA[FIBR-1-SHOTPRO]]></category>
		<category><![CDATA[FQM-KIT]]></category>
		<category><![CDATA[光纤故障定位仪]]></category>
		<category><![CDATA[光纤测试仪]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=1414</guid>
		<description><![CDATA[福禄克Fluke Fiber OneShot Pro 单模光纤故障定位仪（FIBR-1-SHOTPRO,FIBR-1-KITPRO,FIBR-1-KITPRO-VF,FIBR-1-KITPRO-PM,FIBR-1-KITPRO-VFPM,FQM-KIT） 福禄克Fluke Fiber OneShot Pro 单模光纤故障定位仪概览 &#160; 产品描述： Fiber?On... ]]></description>
			<content:encoded><![CDATA[<p><strong><a title="福禄克" href="http://www.faxytech.com">福禄克</a></strong>Fluke <a title="福禄克Fluke Fiber oneshot pro" href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">Fiber OneShot Pro </a>单模<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%85%89%e7%ba%a4%e6%95%85%e9%9a%9c%e5%ae%9a%e4%bd%8d%e4%bb%aa" title="查看 光纤故障定位仪 的全部文章" target="_blank">光纤故障定位仪</a></span>（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html" title="福禄克Fluke FIBR-1-SHOTPRO">FIBR-1-SHOTPRO</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html" title="福禄克Fluke FIBR-1-KITPRO">FIBR-1-KITPRO</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html" title="福禄克FLuke FIBR-1-KITPRO-VF">FIBR-1-KITPRO-VF</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html" title="福禄克Fluke FIBR-1-KITPRO-PM">FIBR-1-KITPRO-PM</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html" title="福禄克Fluke FIBR-1-KITPRO-VFPM">FIBR-1-KITPRO-VFPM</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fqm-kit" title="查看 FQM-KIT 的全部文章" target="_blank">FQM-KIT</a></span>）</p>
<h4><strong><a title="福禄克" href="http://www.faxytech.com">福禄克</a></strong>Fluke <a title="福禄克Fluke Fiber oneshot pro" href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">Fiber OneShot Pro </a>单模光纤故障定位仪概览</h4>
<p><a href="http://www.faxytech.com/wp-content/uploads/2011/08/FiberOneShotPRO.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-4089" title="福禄克Fluke FiberOneShotPRO Fiber-1-shot PRO" src="http://www.faxytech.com/wp-content/uploads/2011/08/FiberOneShotPRO.jpg" alt="福禄克Fluke FiberOneShotPRO Fiber-1-shot PRO" width="390" height="308" /></a></p>
<p>&nbsp;</p>
<table border="1" cellspacing="1" cellpadding="1" width="100%" bordercolor="#cccccc">
<tbody>
<tr>
<td width="150" align="center" bordercolor="#cccccc"><strong>产品描述：</strong></td>
<td colspan="5" bordercolor="#cccccc">Fiber?OneShot??PRO?是您的一线响应诊断工具及单模光纤故障排除工具.</td>
</tr>
<tr>
<td align="center" bordercolor="#cccccc"><strong>产品照片：</strong></td>
<td colspan="5" bordercolor="#cccccc"></td>
</tr>
<tr>
<td align="center" bordercolor="#cccccc"><strong>概述：</strong></td>
<td colspan="5" bordercolor="#cccccc">Fiber?OneShot??PRO?能在不到五秒内定位长达?15?英里（23,000?米以上）内单模光纤严重的弯曲、高损耗接头、断路及变脏的连接器等问题，非常适合于大型运营商网络、MSO、城市、农村地区、地区运营商及校园环境的应用。</td>
</tr>
<tr>
<td align="center" bordercolor="#cccccc"><strong>产品功能：</strong></td>
<td colspan="5" bordercolor="#cccccc">1、?分析长达?15?英里（超过?23000?米）的光纤链路<br />
2、?可在?5?秒内分析光纤链路，平均工作时间减少多达?30%<br />
3、?定位高损耗事件，取消使用试错法，查找单模光纤上的最常见故障<br />
4、?定位反射事件，允许用户分析信道<br />
5、?定位光纤断裂情况，允许用户快速隔离断裂和故障，无需解释复杂图形<br />
6、?定位多个事件/故障，允许用户“查看”信道中的所有事件</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4><strong><a title="福禄克" href="http://www.faxytech.com">福禄克</a></strong>Fluke <a title="福禄克Fluke Fiber oneshot pro" href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">Fiber OneShot Pro </a>单模光纤故障定位仪?技术指标</h4>
<div>
<table border="1" width="100%" bordercolor="#cccccc">
<tbody>
<tr>
<td colspan="2">一般规格</td>
</tr>
<tr>
<td width="150" align="center"><strong>电池工作<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span></strong></td>
<td>0?C?～?50?C</td>
</tr>
<tr>
<td align="center"><strong>非工作</strong></td>
<td>-20?C?～?60?C</td>
</tr>
<tr>
<td align="center"><strong>温度</strong></td>
<td></td>
</tr>
<tr>
<td align="center"><strong>工作相对</strong></td>
<td>95%?(10?C?～?35?C)</td>
</tr>
<tr>
<td align="center"><strong>湿度</strong></td>
<td>75%?(35?C?～?40?C)</td>
</tr>
<tr>
<td align="center"><strong>（无冷凝）</strong></td>
<td>不受控制?&lt;10??C</td>
</tr>
<tr>
<td align="center"><strong>震动</strong></td>
<td>随机，5?Hz?～?500?Hz，MIL-PRF-28800F?2?类</td>
</tr>
<tr>
<td align="center"><strong>冲击</strong></td>
<td>1?米跌落测试</td>
</tr>
<tr>
<td align="center"><strong>海拔</strong></td>
<td>9,842?英尺/3,000?米</td>
</tr>
<tr>
<td align="center"><strong>EMC</strong></td>
<td>EN?61326-1:2004</td>
</tr>
<tr>
<td align="center"><strong>电池类型</strong></td>
<td>2?节?AA?碱性电池（不带电池充电器）</td>
</tr>
<tr>
<td align="center"><strong>电池使用寿命</strong></td>
<td>超过?1,500?次测试（典型）</td>
</tr>
<tr>
<td align="center"><strong>激光安全</strong></td>
<td>CDRH?1?类,符合?EN?60825-2?标准</td>
</tr>
<tr>
<td align="center"><strong>LCD?类型</strong></td>
<td>背光黑白显示器（段码式）</td>
</tr>
<tr>
<td align="center"><strong>折射指数范围</strong></td>
<td>1.45?-?1.5（出厂默认值为?1.468）</td>
</tr>
<tr>
<td align="center"><strong>自动关闭</strong></td>
<td>如果没有按下按键，5?分钟将自动关闭,首先关闭背光。</td>
</tr>
<tr>
<td align="center"><strong>工厂<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>间隔</strong></td>
<td>无</td>
</tr>
<tr>
<td align="center"><strong>输出波长</strong></td>
<td>25?C?时：1550?nm?±?20?nm</td>
</tr>
<tr>
<td align="center"><strong>激光类别</strong></td>
<td>CDRH?1?类，符合?EN?60825-2</td>
</tr>
<tr>
<td align="center"><strong>最大检测距离</strong></td>
<td>75,459?英尺或?23,000?米</td>
</tr>
<tr>
<td align="center"><strong>事件最大显示数量</strong></td>
<td>9</td>
</tr>
<tr>
<td rowspan="2" height="38" align="center"><strong>距离精度</strong></td>
<td>反射事件1：±（1?m?+?0.1?%?x?光纤长度）</td>
</tr>
<tr>
<td>非反射事件2：±（3?m?+?0.1?%?x?光纤长度）</td>
</tr>
<tr>
<td align="center"><strong>测试速度</strong></td>
<td>典型测试时间：5?秒</td>
</tr>
<tr>
<td align="center"><strong>连接器</strong></td>
<td>可拆卸/可清洁的?SC?适配器、UPC?抛光</td>
</tr>
<tr>
<td align="center"><strong>所测光纤类型</strong></td>
<td>9/125?靰m?单模</td>
</tr>
<tr>
<td align="center"><strong>检测,反射事件3</strong></td>
<td>-45?dB?默认阈值（用户可选范围：-24?dB?至?-62?dB，以?1?dB?为增量）</td>
</tr>
<tr>
<td align="center"><strong>可测最大反射</strong></td>
<td>-24?dB</td>
</tr>
<tr>
<td align="center"><strong>检测损耗事件4</strong></td>
<td>1.5?dB?默认阈值（用户可配置范围：0.5?dB?至?6.1?dB（以?0.1?dB?为增量进行设置）</td>
</tr>
<tr>
<td align="center"><strong>测试端口的质量</strong></td>
<td>如果无光纤连接，或连接器变脏，则故障排除工具会显示?0?m?或?0?ft。</td>
</tr>
<tr>
<td align="center"><strong>活动光纤检测</strong></td>
<td>检测?1250?nm?至?1625?nm?的光纤信号,?如有信号则显示?ACTIVE?LINE（有信号）。<br />
首次检测后，<br />
每?3?秒搜索一次信号。<br />
最大输入功率为?+7?dB。</td>
</tr>
<tr>
<td rowspan="4" align="center"><strong>认证及合规性</strong></td>
<td>P符合相关的欧盟标准</td>
</tr>
<tr>
<td>;符合相关的澳大利亚标准</td>
</tr>
<tr>
<td>通过加拿大标准协会?CSA?C22.2?No.?61010.1.04?的认证</td>
</tr>
<tr>
<td>??符合?FCC?规则?A?部分?A?类要求</td>
</tr>
<tr>
<td colspan="2" align="left">1、± 用户设置的折射指数 (IOR) 误差 ± 事件定位误差。<br />
2、± 用户设置的折射指数 (IOR) 误差 ± 事件定位误差。<br />
3、检测反射值大于 -62 dB 的事件位置。测试端口反射值 &lt;35 dB 时，检测端口连接器后侧 &gt;2m 的事件。事件反射值 &lt;35 dB 时，检测事件后侧 &gt;3m 的事件<br />
4、在测试端口反射值 &lt;-35 dB 且任何预先事件的反射值 &lt;-35 dB 时，检测测试端口后侧 &gt;10 m 的事件。事件前的最大链路损耗 &lt;7 dB。</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
<h4><strong><a title="福禄克" href="http://www.faxytech.com">福禄克</a></strong>Fluke <a title="福禄克Fluke Fiber oneshot pro" href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">Fiber OneShot Pro </a>单模光纤故障定位仪特性</h4>
<div>
<p><strong>?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fiber-oneshot.html" title="FLUKE Fiber OneShot光纤断点测试仪">Fiber OneShot</a></span> PRO 优点</strong></p>
<div>
<p><strong>节省时间</strong>—在五秒时间内完成光纤链路的分析，节省 30% 的平均工作时间</p>
<p><strong>简单易用</strong>—没有需要理解的复杂数据，其一键式测试功能意味着无需任何培训</p>
<p><strong>便携</strong>—坚固的手持式设备，适合室外环境</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
<div><strong>?Fiber OneShot PRO 功能</strong></div>
<div>
<ol>
<li> 几秒时间内检测长达 75,459 英尺（23,000 米）的光纤</li>
<li> 定位单模光纤中的严重弯曲、高损失接合处、断路和脏连接器</li>
<li> 保存高达 99 份测试结果，方便日后查看</li>
<li> 分析光纤链路，确定通道连接性</li>
<li> 定位由端面污染或连接点问题导致的误码率源</li>
<li> 每条光纤链路最多可报告 9 个事件</li>
</ol>
</div>
<div><strong>?Fiber OneShot PRO 客户评论</strong></div>
<div>
<ol>
<li> “无需在故障和集线器之间来回奔波”</li>
<li> “节省高达 30% 的平均工作时间”</li>
<li> “让我迅速了解光纤的大概情况”</li>
<li> “建议老板给我们买一个”</li>
<li> “我们 33% 的测试都是在没有光线的情况下进行的。它非常适合这些情况”</li>
<li> “它轻快，便携，真的是个好工具”</li>
</ol>
</div>
<div><strong>?Fiber OneShot PRO 客户</strong></div>
<ol>
<li> 地区贝尔运营公司与服务供应商</li>
<li> 有线电视运营商/MSO</li>
<li> 独立地区性和农村电信公司</li>
<li> 单模网络技术人员</li>
<li> 承包商</li>
<li> 网络安装公司</li>
<li> 城域网</li>
</ol>
<p>&nbsp;</p>
<h4><strong><a title="福禄克" href="http://www.faxytech.com">福禄克</a></strong>Fluke <a title="福禄克Fluke Fiber oneshot pro" href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">Fiber OneShot Pro </a>单模光纤故障定位仪型号、选件和附件</h4>
<div>
<table>
<tbody>
<tr>
<td width="150" align="center">型号</td>
<td>说明</td>
</tr>
<tr>
<td align="center"><strong><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">FIBR-1-SHOTPRO</a></strong></td>
<td>仅用于?Fiber?OneShot?PRO?—?包含仪表、SC?适配器，以及?CD、手册和电池上的?22?种语言的快速参考指南</td>
</tr>
<tr>
<td align="center"><strong><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">FIBR-1-KITPRO</a></strong></td>
<td>Fiber?OneShot?PRO-SC-Kit?—?包含仪表、SC?适配器、UPC-UPC?2?米跳线、皮套、软包，以及?CD、手册和电池上的?22?种语言的快速参考指南</td>
</tr>
<tr>
<td align="center"><strong><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">FIBR-1-KITPRO-VF</a></strong></td>
<td>带?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/visifault.html" title="福禄克FLUKE VISIFAULT红光笔">VisiFault</a></span>?的?Fiber?OneShot?PRO-SC-Kit?—?包含仪表、SC?适配器、UPC-UPC?2?米跳线、皮套、软包，以及?CD、手册和电池上的?22?种语言的快速参考指南，外加带?2.5?毫米通用适配器的?VisiFault?可视化故障定位仪</td>
</tr>
<tr>
<td align="center"><strong><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">FIBR-1-KITPRO-PM</a></strong></td>
<td>带?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/simplifiber-pro.html" title="福禄克FLUKE SimpliFiber Pro光纤测试仪">SimpliFiber</a></span>?Pro?的?Fiber?OneShot?PRO-SC-Kit?—?包含仪表、SC?适配器、UPC-UPC?2?米跳线、皮套、软包，以及?CD、手册和电池上的?22?种语言的快速参考指南，外加?SimpliFiber?Pro?光纤功率计与?SC?适配器</td>
</tr>
<tr>
<td align="center"><strong><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">FIBR-1-KITPRO-VFPM</a></strong></td>
<td>带?VisiFault?和?SimpliFiber?Pro?的?Fiber?OneShot?PRO-SC-Kit?—?包含仪表、SC?适配器、UPC-UPC?2?米跳线、皮套、软包，以及?CD、手册和电池上的?22?种语言的快速参考指南，外加带?2.5?毫米通用适配器的?VisiFault?可视化故障定位仪和?SimpliFiber?Pro?光纤功率计与?SC?适配器</td>
</tr>
<tr>
<td align="center"><strong><a href="http://www.faxytech.com/archives/fluke-fiber-oneshot-pro.html ?">FQM-KIT</a></strong></td>
<td>Fiber?QuickMap?工具包?—?包含?Fiber?QuickMap、SC/SC?与?SC/LC（50?微米?和?62.5?微米）混合测试基准跳线以及便携软包</td>
</tr>
</tbody>
</table>
</div>
</div>
<p>&nbsp;</p>
<p><span style="color: #ff0000;">以下是2012年5月28日更新新型号。（以以下新型号为准！）</span></p>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fibr-1-shotpro" title="查看 FIBR-1-SHOTPRO 的全部文章" target="_blank">FIBR-1-SHOTPRO</a></span></td>
<td>仅 Fiber OneShot PRO —包括功率表、SC 适配器、CD 上的 22 种语言快速参考书，手册和电池</td>
</tr>
<tr>
<td><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fibr-1-kitpro" title="查看 FIBR-1-KITPRO 的全部文章" target="_blank">FIBR-1-KITPRO</a></span></td>
<td>Fiber OneShot PRO-SC-套件—包括功率表、SC 适配器、UPC-UPC 2 米插接线、皮套、手提箱、CD 上的 22 种语言快速参考书，手册和电池</td>
</tr>
<tr>
<td><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fibr-1-kitpro-vf" title="查看 FIBR-1-KITPRO-VF 的全部文章" target="_blank">FIBR-1-KITPRO-VF</a></span></td>
<td>Fiber OneShot PRO-SC-套件，带 VisiFault—包括功率表、SC 适配器、UPC-UPC 2 米插接线、皮套、手提箱、CD 上的 22 种语言快速参考书，手册和电池，还有 VisiFault 可视化故障定位器和 2.5 mm 通用适配器</td>
</tr>
<tr>
<td><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fibr-1-kitpro-pm" title="查看 FIBR-1-KITPRO-PM 的全部文章" target="_blank">FIBR-1-KITPRO-PM</a></span></td>
<td>Fiber OneShot PRO-SC-套件，带 SimpliFiber Pro—包括功率表、SC 适配器、UPC-UPC 2 米插接线、皮套、手提箱、CD 上的 22 种语言快速参考书，手册和电池，还有 SimpliFiber Pro 光功率计和 SC 适配器</td>
</tr>
<tr>
<td>FIBR-1-PRO-LSPM</td>
<td>内含 SimpliFiber Pro 和光源的 Fiber OneShot PRO-SC 套件 — 包括计<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克计量">计量</a></span>仪、SC 适配器、UPC-UPC 2 米跳线、皮套、工具包、22 种语言的快速参考指南 CD、手册和电池以及 SimpliFiber Pro 光功率计和 1310nm/1550nm 光源</td>
</tr>
<tr>
<td><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/fibr-1-kitpro-vfpm" title="查看 FIBR-1-KITPRO-VFPM 的全部文章" target="_blank">FIBR-1-KITPRO-VFPM</a></span></td>
<td>Fiber OneShot PRO-SC-套件，带 VisiFault 和 SimpliFiber Pro—包括功率表、SC 适配器、UPC-UPC 2 米插接线、皮套、手提箱、CD 上的 22 种语言快速参考书，手册和电池，还有 VisiFault 可视化故障定位器和 2.5 mm 通用适配器以及 SimpliFiber Pro 光功率计和 SC 适配器</td>
</tr>
</tbody>
</table>
<div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td></td>
<td>FIBR- QS ? ? ? ? ? ? ? ? ? ? ? ? ? ?包括： Fiber OneShot PRO —包括功率表、SC 适配器、CD 上的 22 种语言快速参考书，手册和电池，?<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-fiber-quickmap.html" title="福禄克Fluke Fiber QuickMap">Fiber QuickMap</a></span>、SC/ LC（50 和 62.5 μm）混合测试参考线、<a title="福禄克FLUKE VISIFAULT红光笔" href="http://www.faxytech.com/archives/visifault.html">VisiFault</a> VFL 和随身包。</td>
</tr>
</tbody>
</table>
</div>
<div>零配件</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>FIBR-AC-UAPC</td>
<td>1 米长的 UPC-APC 发射线</td>
</tr>
<tr>
<td>FIBR-UPC-CORD-2M</td>
<td>2 米 UPC-UPC 插接线</td>
</tr>
<tr>
<td>NFK3-LAUNCH</td>
<td>发射/接收光纤，9/125 μm，SC/UPC 至 SC/UPC，130 m</td>
</tr>
<tr>
<td>NFK3-LAUNCH-ST</td>
<td>发射/接收光纤，9/125 μm，SC/UPC 至 ST/UPC，130 m</td>
</tr>
<tr>
<td>NFK3-LAUNCH-LC</td>
<td>发射/接收光纤，9/125 μm，SC/UPC 至 LC/UPC，130 m</td>
</tr>
<tr>
<td>NFK3-LAUNCH-FC</td>
<td>发射/接收光纤，9/125 μm，SC/UPC 至 FC/UPC，130 m</td>
</tr>
<tr>
<td>NF-OPRT-SC</td>
<td>更换可互换的 SC 适配器</td>
</tr>
<tr>
<td>OF-OPRT-LC</td>
<td>更换可互换的 LC 适配器</td>
</tr>
</tbody>
</table>
<div>
<div>零配件</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>FIBR-AC-UAPC</td>
<td>1 米长的 UPC-APC 发射线</td>
</tr>
<tr>
<td>FIBR-UPC-CORD-2M</td>
<td>2 米 UPC-UPC 插接线</td>
</tr>
<tr>
<td>NFK3-LAUNCH</td>
<td>发射/接收光纤，9/125 μm，SC/UPC 至 SC/UPC，130 m</td>
</tr>
<tr>
<td>NFK3-LAUNCH-ST</td>
<td>发射/接收光纤，9/125 μm，SC/UPC 至 ST/UPC，130 m</td>
</tr>
<tr>
<td>NFK3-LAUNCH-LC</td>
<td>发射/接收光纤，9/125 μm，SC/UPC 至 LC/UPC，130 m</td>
</tr>
<tr>
<td>NFK3-LAUNCH-FC</td>
<td>发射/接收光纤，9/125 μm，SC/UPC 至 FC/UPC，130 m</td>
</tr>
<tr>
<td>SC-适配器</td>
<td>更换可互换的 SC 适配器</td>
</tr>
<tr>
<td>SMC-9-SCSCAPC</td>
<td>单模发射电缆 9 ?m SC/SCAPC</td>
</tr>
<tr>
<td>SMC-9-SCFCAPC</td>
<td>单模发射电缆 9 ?m SC/FCAPC</td>
</tr>
<tr>
<td>SMC-9-SCLCAPC</td>
<td>单模发射电缆 9 ?m SC/LCAPC</td>
</tr>
</tbody>
</table>
</div>
<div>支持</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>GLD-FOS-PRO</td>
<td>适用于 FIBR-1-KITPRO 或 FIBR-1-KITPRO-VF 的 1 年金牌支持</td>
</tr>
<tr>
<td>GLD-FOS-MULTIKITS</td>
<td>适用于 FIBR-1-KITPRO-PM 或 FIBR-1-KITPRO-VFPM 或 LSPM 的 1 年金牌支持</td>
</tr>
</tbody>
</table>