		<item>
		<title>电力开关柜7*24小时不间断温度监测方案</title>
		<link>http://www.faxytech.com/archives/724-temp.html</link>
		<comments>http://www.faxytech.com/archives/724-temp.html#comments</comments>
		<pubDate>Tue, 03 Dec 2019 03:20:08 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[温度]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11217</guid>
		<description><![CDATA[应用背景 在电力系统中，高压开关、变压器、载流母线等高压设备在负载电流过大时会出现温升过高，最后使绝缘部件性能劣化，甚至击穿。根据电力安全监督部门提供数据分析，全国用电大... ]]></description>
			<content:encoded><![CDATA[<h4>应用背景</h4>
<p>在电力系统中，高压开关、变压器、载流母线等高压设备在负载电流过大时会出现温升过高，最后使绝缘部件性能劣化，甚至击穿。根据电力安全监督部门提供数据分析，全国用电大户企业每年因为高压开关、母线<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>过高引发的重大事故上千起，给生产和经营造成巨大经济损失。</p>
<p>电力设备的故障有多种多样，但大多数都伴有发热的现象。如通过监测变压器、高压电缆接头、高压开关触点<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%b8%a9%e5%ba%a6" title="查看 温度 的全部文章" target="_blank">温度</a></span>的运行情况，可有效防止高压输、变电故障的发生，为实现安全生产提供有效保障。而基于在线式温度监测手段的故障预警方法可提高故障预警的可靠性和及时性，符合行业发展趋势。</p>
<h4>温度监测方式对比</h4>
<table width="100%">
<tbody>
<tr>
<td width="32%"><strong>方案</strong></td>
<td width="33%"><strong>红外<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="测温">测温</a></span></strong></td>
<td width="35.01%"><strong>贴片测温</strong></td>
</tr>
<tr>
<td width="32%">测温方式</td>
<td width="33%">非接触式</td>
<td width="35.01%">接触式</td>
</tr>
<tr>
<td width="32%">响应时间</td>
<td width="33%">130毫秒</td>
<td width="35.01%">3分钟</td>
</tr>
<tr>
<td width="32%">传感器故障报警</td>
<td width="33%">有</td>
<td width="35.01%">无</td>
</tr>
<tr>
<td width="32%">安装位置</td>
<td width="33%">电气柜外壁</td>
<td width="35.01%">电气柜内部</td>
</tr>
<tr>
<td width="32%">供电</td>
<td width="33%">在线供电</td>
<td width="35.01%">锂电池供电</td>
</tr>
<tr>
<td width="32%"><strong>综述</strong></td>
<td width="33%"><strong>红外测温具有快速响应，无需接触带电目标，是一种安全测温手段。测温传感器具有自身故障报警，避免因给出虚假温度而导致的误报，提醒用户及时检查。</strong></td>
<td width="35.01%"><strong>需要接触带电目标，对于大量测温点，有潜在被击穿风险。故障的传感器会提供虚假温度而无法察觉，导致潜在漏报风险。</strong></td>
</tr>
</tbody>
</table>
<h4>红外测温方案介绍</h4>
<p>本方案针对室内电气柜母线触头温度过热问题提供一种在线式监测手段。电气柜触头温度的检测采用的是非接触式（红外）探头，每面电气柜有6个触头监测点，其所对应的测温探头集中连到一个电路盒上。电路盒提供了现场温度显示、现场报警和远程RS485通讯的功能。现场报警器可对触头出现过热情况的电气柜提供报警指示。远程计算机放置于监控室内，通过多点组网的温度软件集中对电气柜触头进行实时的温度显示和远程报警。</p>
<p>&nbsp;</p>
<h4><strong>配置示意图</strong></h4>
<p><a href="http://www.faxytech.com/wp-content/uploads/2019/12/peizhi.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11218" title="peizhi" src="http://www.faxytech.com/wp-content/uploads/2019/12/peizhi.jpg" alt="" width="659" height="265" /></a></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2019/12/peizhi2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11219" title="peizhi2" src="http://www.faxytech.com/wp-content/uploads/2019/12/peizhi2.jpg" alt="" width="567" height="40" /></a></p>
<p>&nbsp;</p>
<h4><strong>标准配置清单</strong></h4>
<table width="100%">
<tbody>
<tr>
<td width="32%"><strong>名称</strong></td>
<td colspan="2" width="33%"><strong>安装点位</strong></td>
<td width="35.01%"><strong>数量</strong></td>
</tr>
<tr>
<td width="32%">红外测温仪</td>
<td colspan="2" rowspan="3" width="33%">电容路柜</td>
<td width="35.01%">6</td>
</tr>
<tr>
<td width="32%">电路盒</td>
<td width="35.01%">1</td>
</tr>
<tr>
<td width="32%">报警器</td>
<td width="35.01%">1</td>
</tr>
<tr>
<td width="32%">红外测温仪</td>
<td colspan="2" rowspan="3" width="33%">站用变柜</td>
<td width="35.01%">6</td>
</tr>
<tr>
<td width="32%">电路盒</td>
<td width="35.01%">1</td>
</tr>
<tr>
<td width="32%">报警器</td>
<td width="35.01%">1</td>
</tr>
<tr>
<td width="32%">红外测温仪</td>
<td colspan="2" rowspan="3" width="33%">主变开关柜</td>
<td width="35.01%">6</td>
</tr>
<tr>
<td width="32%">电路盒</td>
<td width="35.01%">1</td>
</tr>
<tr>
<td width="32%">报警器</td>
<td width="35.01%">1</td>
</tr>
<tr>
<td width="32%">红外测温仪</td>
<td colspan="2" rowspan="3" width="33%">主变刀闸柜</td>
<td width="35.01%">6</td>
</tr>
<tr>
<td width="32%">电路盒</td>
<td width="35.01%">1</td>
</tr>
<tr>
<td width="32%">报警器</td>
<td width="35.01%">1</td>
</tr>
<tr>
<td width="32%"><strong>多探头监视软件</strong></td>
<td colspan="2" width="33%"><strong>总计</strong></td>
<td width="35.01%"><strong>1</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4><strong>主要硬件参数</strong></h4>
<table width="100%">
<tbody>
<tr>
<td width="33%"><strong>装置名称</strong></td>
<td width="33.5%"><strong>参数</strong></td>
<td width="33.5%"><strong>指标</strong></td>
</tr>
<tr>
<td rowspan="7" width="33%">红外测温仪</td>
<td width="33.5%">测温范围</td>
<td width="33.5%">-40~600℃（范围可调）</td>
</tr>
<tr>
<td width="33.5%">精度</td>
<td width="33.5%">±1%或±1℃取大值</td>
</tr>
<tr>
<td width="33.5%">温度分辨率</td>
<td width="33.5%">0.1℃</td>
</tr>
<tr>
<td width="33.5%">距离系数</td>
<td width="33.5%">10：1</td>
</tr>
<tr>
<td width="33.5%">响应时间</td>
<td width="33.5%">130ms</td>
</tr>
<tr>
<td width="33.5%">耐环境温度</td>
<td width="33.5%">120℃</td>
</tr>
<tr>
<td width="33.5%">探头体积</td>
<td width="33.5%">Ø14×28mm</td>
</tr>
<tr>
<td rowspan="4" width="33%">电路盒</td>
<td width="33.5%">报警输出</td>
<td width="33.5%">常开/常闭</td>
</tr>
<tr>
<td width="33.5%">信号输出</td>
<td width="33.5%">RS485</td>
</tr>
<tr>
<td width="33.5%">信号传输</td>
<td width="33.5%">有线或无线</td>
</tr>
<tr>
<td width="33.5%">体积</td>
<td width="33.5%">60×80×31.5mm</td>
</tr>
<tr>
<td width="33%">报警器</td>
<td width="33.5%">报警方式</td>
<td width="33.5%">声光报警</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p><strong>安装方式</strong></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2019/12/az.jpg" class="highslide-image" onclick="return hs.expand(this);"></a><a href="http://www.faxytech.com/wp-content/uploads/2019/12/az2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11221" title="az2" src="http://www.faxytech.com/wp-content/uploads/2019/12/az2.jpg" alt="" width="364" height="284" /></a><img class="alignnone size-full wp-image-11220" title="az" src="http://www.faxytech.com/wp-content/uploads/2019/12/az.jpg" alt="" width="281" height="292" /></p>
<p>&nbsp;</p>
<p>上图是测温仪安装布线图，针对6个触头监测点电气柜需要对应开6个测温孔。测温仪、电路盒和报警器均安装于电气柜外部，根据需要系统组网可选择有线传输或无线传输方式。</p>
<p>红外测温探头选型</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2019/12/tt.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11222" title="tt" src="http://www.faxytech.com/wp-content/uploads/2019/12/tt.jpg" alt="" width="412" height="315" /></a></p>
<p>立即定制方案</p>
<p>现在就为您的电气柜<strong>定制一套温度监控方案吧</strong>，识别以下二维码，我们将尽快安排专业的技术服务人员与您联系。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/724-temp.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>电磁波扫盲篇：频率，波长，速度，温度，能量的关系</title>
		<link>http://www.faxytech.com/archives/electromagnetic-wave.html</link>
		<comments>http://www.faxytech.com/archives/electromagnetic-wave.html#comments</comments>
		<pubDate>Wed, 11 Mar 2015 03:29:34 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[波长]]></category>
		<category><![CDATA[温度]]></category>
		<category><![CDATA[电磁波]]></category>
		<category><![CDATA[能量]]></category>
		<category><![CDATA[速度]]></category>
		<category><![CDATA[频率]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=5826</guid>
		<description><![CDATA[1、波的频率和波长满足关系式：波速=波长×频率，所以频率不同的电磁波在真空中具有不同的波长。 2、电磁波在空间是向各个方向传播的，所有这些电磁波仅在波长（或频率）上有所差别，... ]]></description>
			<content:encoded><![CDATA[<p>1、波的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e9%a2%91%e7%8e%87" title="查看 频率 的全部文章" target="_blank">频率</a></span>和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%b3%a2%e9%95%bf" title="查看 波长 的全部文章" target="_blank">波长</a></span>满足关系式：<span style="color: #ff0000;"><strong>波速=波长×频率</strong></span>，所以频率不同的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%94%b5%e7%a3%81%e6%b3%a2" title="查看 电磁波 的全部文章" target="_blank">电磁波</a></span>在真空中具有不同的波长。</p>
<p>2、电磁波在空间是向各个方向传播的，所有这些电磁波仅在波长（或频率）上有所差别，而在本质上完全相同，且波长不同的电磁波在真空中的传播<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e9%80%9f%e5%ba%a6" title="查看 速度 的全部文章" target="_blank">速度</a></span>都是电磁波的传播速度，即等于光速，是3x10e8米／秒。在空气中和在真空中近似。</p>
<p>3、不同频率(或不同波长)的电磁波的传播速度都相同，<span style="color: #ff0000;">电磁波的频率愈高，相应的波长就越短</span>。所以频率较大的电磁波，波长较短。无线电波的波长最长（频率最低），而射线的波长最短（频率最高）。</p>
<p>4、无线电频谱：通常无线电波所指的是从极低频10KHz到极超高频的顶点30GHz（Giga Hertz），因为超出这个范围以外的无线电频谱，其特性便有很大不同了，例如光线、X射线等，而在上述10KHz到30GHz，通常划分成七个区域，参看下表，其中高频3～30MHz就是我们通常所说的短波。</p>
<p>5、<strong><span style="color: #ff0000;"><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%83%bd%e9%87%8f" title="查看 能量 的全部文章" target="_blank">能量</a></span>=h×频率</span></strong> （h为6.626乘10的-34次方 焦耳·秒是普朗克常数），电磁波的能量与频率成正比，系数为普朗克常量h。即频率越高，波长越短，能量越大。</p>
<div>
<div>6、 关于穿透性，波长越长，频率越低，穿透性越好。</div>
<div>7、频率越高，传输时的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>越小，即传播的距离越远。注意，不要把穿透率和感应距离混为一谈，否则，就没有发展微波通讯的必要了。</div>
<p><strong>无线电频谱的划分：</strong><br />
极低频 VLF Very Low Frequency频率范围 10KHz &#8211; 30KHz<br />
低频 LF（俗称长波LW）Low Frequency 频率范围 30KHz &#8211; 300KHz<br />
中频 MF （俗称中波MW）Medium Frequency 频率范围 30KHz &#8211; 3000KHz<br />
高频 HF （俗称短波SW）High Frequency 频率范围 3MHz &#8211; 30MHz<br />
极高频 VHF（俗称超短波，而频率在88-108MHZ范围的民用广播则俗称为调频电台FM）Very High Frequency 频率范围 30MHz &#8211; 300MHz<br />
超高频 UHF Ultra High Frequency 频率范围 300MHz &#8211; 3000MHz<br />
极超高频 SHF Super High Frequency 频率范围 3000MHz &#8211; 30000MHz</p>
</div>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/electromagnetic-wave.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>fluke dtx1800测试问题：温度对于衰减的影响</title>
		<link>http://www.faxytech.com/archives/why-attenuation.html</link>
		<comments>http://www.faxytech.com/archives/why-attenuation.html#comments</comments>
		<pubDate>Sat, 13 Sep 2014 02:08:45 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[dtx1800]]></category>
		<category><![CDATA[fluke测试]]></category>
		<category><![CDATA[温度]]></category>
		<category><![CDATA[衰减]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=4813</guid>
		<description><![CDATA[作为福禄克的老牌合作伙伴，我们经常会受到客户对于fluke dtx-1800测试的各种疑问，而“衰减”一词也是问得最多的，今天我们来谈一谈温度对于电缆衰减的影响。 电缆衰减受到链路长度、温... ]]></description>
			<content:encoded><![CDATA[<p>作为福禄克的老牌合作伙伴，我们经常会受到客户对于fluke dtx-1800测试的各种疑问，而“<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>”一词也是问得最多的，今天我们来谈一谈<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>对于电缆<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%a1%b0%e5%87%8f" title="查看 衰减 的全部文章" target="_blank">衰减</a></span>的影响。</p>
<p>电缆衰减受到链路长度、<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%b8%a9%e5%ba%a6" title="查看 温度 的全部文章" target="_blank">温度</a></span>、湿度等因素的影响。对于6类线缆，标准有明确说明，电缆的工作温度为20oC,在20oC到40oC范围内，温度每升高1oC，衰减增加0.4%，在40oC到60oC之间，温度每升高1oC，衰减增加0.6%。事实上电缆在40oC时衰减会比20oC高8%。因此天气炎热时，长链路，比如超过80米的链路，衰减测试通常会出现FAIL的情况。许多工程商都希望能在<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="综合布线">综合布线</a></span>系统测试的时候有一些温度补偿的方法，将由于高温造成的衰减不合格情况减少，提高通过率。在ANSI/TIA/EIA-568-B正式颁布前，在现场综合布线系统福禄克<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-1800.html" title="福禄克FLUKE DTX-1800">DTX-1800</a></span>或者<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>测试的时候的确有在测试仪器上输入现场温度，通过计算进行补偿的做法。</p>
<p>但是在实际应用中，衰减是一项关键参数，它关系到最终应用时能否保证接收器收到足够强度的信号，因此温度补偿是不可取的。在ANSI/TIA/EIA-568-B.2-1和ISO/IEC11801:2002正式颁布后，现场进行温度补偿不再是可以接受的解决办法了。</p>
<p>为了保证最终信道的衰减性能，唯一的办法就是按照现场情况将永久链路长度做相应的减短。具体可以参考下表来计算根据现场温度应如何调整永久链路长度。整条信道的长度假设在20oC时最长为90米水平链路加10米用户跳线。</p>
<p>如果由于工程现场必须要长于80米的链路，就需要和业主协调好，说明衰减与长度、温度的关系，取得业主的谅解，接受这些衰减未通过综合布线系统测试的信息点。但是由于衰减不合格的链路在传输数据时很不稳定，因此应尽量说服业主，或者将这些链路作为低速数据传输或电话的应用。</p>
<p>&nbsp;</p>
]]></content:encoded>