<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; 回环测试</title>
	<atom:link href="http://www.faxytech.com/tag/%e5%9b%9e%e7%8e%af%e6%b5%8b%e8%af%95/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>福禄克FLUKE CertiFiber Pro OLTS（CFP2-100-Q）图例细节步骤（回环测试）</title>
		<link>http://www.faxytech.com/archives/cfp-test.html</link>
		<comments>http://www.faxytech.com/archives/cfp-test.html#comments</comments>
		<pubDate>Wed, 24 Mar 2021 04:19:55 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[CertiFiber Pro]]></category>
		<category><![CDATA[CFP2-100-Q]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[OLTS]]></category>
		<category><![CDATA[回环测试]]></category>
		<category><![CDATA[图例]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[细节步骤]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11955</guid>
		<description><![CDATA[利用CertiFiber Pro OLTS进行测试 在CertiFiber Pro中配置好测试之后，接下来就可以执行测试。第一步是利用我们之前配置的光纤端面检查测试，确保一切是清洁的。过程就是端面检查，并在必要时进... ]]></description>
			<content:encoded><![CDATA[<p>利用<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> Pro <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/olts" title="查看 OLTS 的全部文章" target="_blank">OLTS</a></span>进行测试 在<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber Pro">CertiFiber Pro</a></span>中配置好测试之后，接下来就可以执行测试。第一步是利用我们之前配置的光纤端面检查测试，确保一切是清洁的。过程就是端面检查，并在必要时进行清洁，然后在清洁后再次检查。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2021/03/TRC.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11956" title="图4.选择端面检查测试，并检查所有TRC（测试参考跳线）以及与被测光纤的连接。" src="http://www.faxytech.com/wp-content/uploads/2021/03/TRC.jpg" alt="" width="615" height="222" /></a></p>
<p>图4.选择端面检查测试，并检查所有TRC（测试参考跳线）以及与被测光纤的连接。</p>
<p>证明并记录所有跳线和端口是清洁的之后，我们可以通过按SET REF (设置参考)按钮，利用参考向导(Reference Wizard)，继续设置参考。按照参考向导操作完成之后，该过程中的最后步骤是断开连接两段测试参考跳线的连接器，并把测试参考跳线连接到被测光纤链路，然后轻触HOME (主页)按钮。此时，就需要远端的助手把作为环回的测试参考跳线TRC</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2021/03/set-ref.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11957" title="set-ref" src="http://www.faxytech.com/wp-content/uploads/2021/03/set-ref.jpg" alt="" width="618" height="245" /></a></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2021/03/set-ref-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11958" title="set-ref-2" src="http://www.faxytech.com/wp-content/uploads/2021/03/set-ref-2.jpg" alt="" width="619" height="250" /></a></p>
<p>环回连接到被测链路。在尝试测试之前，您必须将清洁的TRC测试参考跳线、SmartLoop智能环回跳线和相应的QuickClean一键式清洁笔送到远端位置。图5.执行参考过程和TRC（测试参考跳线）检验过程。这将能够保证良好的测量结果。对于单模TRC，损耗应小于0.25dB。</p>
<p><strong>您的OLTS测试配置如下图所示：</strong></p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2021/03/OFP-test.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11959" title="OFP-test" src="http://www.faxytech.com/wp-content/uploads/2021/03/OFP-test.jpg" alt="" width="617" height="366" /></a></p>
<p>图6.OLTS环回测试的测试连接，在远端位置使用一根测试参考条线作为环回跳线。标准测试结果包含实测损耗、预算计算，用于链路和长度评估。</p>
<p>从测试结果可以看出，损耗较低，所以裕量比较好，这说明两根光纤的状态都比较好；然而，也可能是一条链路的状态非常好，而另一条链路处于临界状态，所以线对才通过了测试。鉴于此，建议您稍微多花一点时间，利用<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>对线对进行测试，这不仅能够发现问题，而且能够提示如何修正问题。为了执行该项测试，我们将使用SmartLoop OTDR测试作为我们的2级(扩展)测试。这将使我们能够评估两根光纤，以及组成两条链路的元件。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/cfp-test.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克CertiFiber PRO(CFP2-100-Q)做回环测试的注意事项</title>
		<link>http://www.faxytech.com/archives/cfp-smartloop.html</link>
		<comments>http://www.faxytech.com/archives/cfp-smartloop.html#comments</comments>
		<pubDate>Wed, 10 Mar 2021 03:51:43 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[CertiFiber Pro]]></category>
		<category><![CDATA[CFP2-100-Q]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[OptiFiberPro OTDR]]></category>
		<category><![CDATA[回环测试]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11936</guid>
		<description><![CDATA[对于园区建筑之间或站点之间的单模光纤链路，有时可能无法访问链路远端所在场所。许多组织在数据中心或工作场所之间布有暗光纤，但可能不允许外部人员在现场进行安装测试。您如何跨... ]]></description>
			<content:encoded><![CDATA[<p>对于园区建筑之间或站点之间的单模光纤链路，有时可能无法访问链路远端所在场所。许多组织在数据中心或工作场所之间布有暗光纤，但可能不允许外部人员在现场进行安装测试。您如何跨越这种显而易见的障碍呢？利用<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>网络 <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fluke-versiv.html" title="威测">威测</a></span>平台，您就能够执行有效测试，证明链路安装正确并且运行正常，还能够在福禄克网络 <span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>报告管理软件平台上生成包含测试结果的测试报告。您所需要的只是远端场所的人可以协助连接测试跳线，以便执行测试。以下方法可以帮助您对已安装光纤线对进行1级基本测试和2级扩展测试。在该方案中，我们将使用福禄克网络的 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber" rel="nofollow">CertiFiber</a></span> Pro OLTS<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>（<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/cfp2-100-q" title="查看 CFP2-100-Q 的全部文章" target="_blank">CFP2-100-Q</a></span>）和OptiFiberPro <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-otdr.html" title="DTX OTDR">OTDR</a></span>光纤测试仪（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/ofp2-100-q-ch.html" title="福禄克FLUKE OFP2-100-Q ">OFP2-100-Q</a></span>），以及FI-1000 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fiberinspector-mini.html" title="FiberInspector 袖珍光纤视频显微镜">FiberInspector</a></span> 光纤检测视频探头。</p>
<p>执行测试所需的设备：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2021/03/certifiber-pro.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11937" title="certifiber-pro" src="http://www.faxytech.com/wp-content/uploads/2021/03/certifiber-pro.jpg" alt="" width="606" height="345" /></a></p>
<p>注：为了使该测试方法正常工作，在进行测试之前，必须将经过检查且清洁的测试参考跳线SmartLoop智能环回跳线连接到远端位置。并确保在测试时，有一名助手位于远端位置。 与所有光纤测试一样，端面检查是成功测量的关键环节。如果不进行端面检查，您可能会损坏已安装的连接器。<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/certifiber-pro.html" title="CertiFiber Pro">CertiFiber Pro</a></span>有一个基于USB接口的视频探头选件，用于检查光纤连接器的端面。建议用户充分利用这个视频探头。 此外，带有USB视频探头选件的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/certifiber-pro" title="查看 CertiFiber Pro 的全部文章" target="_blank">CertiFiber Pro</a></span>能够自动按照IEC 61300-3-35标准第2版对光纤端面进行合规判断，测试只需大约1秒钟。视频探头还提供了各种探尖，包括1.25mm和2.5mm通用端面，以及LC和SC闷头。 在开始测试之前，确保在CertiFiber Pro中配置了正确的测试限值。本例中，我们将采用ANSI/TIA-568.3-D标准作为测试限值，您也可以使用IEC 14763-3:2014 SMF限值，但请注意，该限值仅支持5公里以下的SMF链路。如果您使用厂商规定的限值，此处介绍的测试方法是相同的，但可接受的连接器和熔接点损耗极限值可能不同。在该过程的OLTS测试部分，如果没有使用1跳线法设置参考，可能会造成负损耗结果。下图为被测链路示意图，可能会有多个嵌入式连接器和多个熔接点需要考虑。距离可能从建筑物之间的数百米到站点之间的数十公里不等。ANSI/TIA-568.3-D测试限值支持长达40公里的测量。如上所述，ISO测试标准目前仅支持测量到5公里，但正在修订，目的是扩展到10公里。本例中，我们的被测链路位于建筑物之间，每条链路长130米，每条链路有两个连接器，每端一个，没有熔接点，为OS2光纤。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2021/03/fiber-pic.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11938" title="fiber-pic" src="http://www.faxytech.com/wp-content/uploads/2021/03/fiber-pic.jpg" alt="" width="615" height="190" /></a></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/cfp-smartloop.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>