<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; THDI</title>
	<atom:link href="http://www.faxytech.com/tag/thdi/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>THDI，TDDI（%）</title>
		<link>http://www.faxytech.com/archives/tddi.html</link>
		<comments>http://www.faxytech.com/archives/tddi.html#comments</comments>
		<pubDate>Sat, 14 Mar 2020 08:09:01 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[TDDI]]></category>
		<category><![CDATA[THDI]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11361</guid>
		<description><![CDATA[问题：有学员介绍，在涉外项目中，外方用户有THD I（%）&#60;5%的要求，请问这是依据何标准的要求。 回复：可以肯定地说外发不是对THDI（%）的要求，可能是对TDD I（%）的要求，IEEE519-2014中对1... ]]></description>
			<content:encoded><![CDATA[<p><strong>问题：有学员介绍，在涉外项目中，外方用户有THD I（%）&lt;5%的要求，请问这是依据何标准的要求。</strong></p>
<p>回复：可以肯定地说外发不是对<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/thdi" title="查看 THDI 的全部文章" target="_blank">THDI</a></span>（%）的要求，可能是对TDD I（%）的要求，IEEE519-2014中对120 V~69000V接入公用电网的电力用户谐波电流限制见表1。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/03/TDDI.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-11363" title="TDDI" src="http://www.faxytech.com/wp-content/uploads/2020/03/TDDI.jpg" alt="" width="640" height="313" /></a></p>
<p>在电力负荷短路电流和负荷最大需量电流比小于20时，该电力负荷的电流需量畸变率TDD I（%）应小于5%。</p>
<p>这个案例对我国谐波治理立项工作有很好的借鉴意义，目前国内谐波立项依据标准不明确，立项理由不充分。希望电力监管部门、电力用户和<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/pqa" title="电能质量">电能质量</a></span>治理服务提供商可以借鉴这个标准的要求，去进行电力系统谐波监管与治理。</p>
<p><strong><br />
</strong></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/tddi.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>关于总谐波电流有效值THDI（%）定义和应用的问题？</title>
		<link>http://www.faxytech.com/archives/thdi.html</link>
		<comments>http://www.faxytech.com/archives/thdi.html#comments</comments>
		<pubDate>Wed, 04 Mar 2020 08:05:39 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[THDI]]></category>
		<category><![CDATA[Total Harmonic Current Distortion]]></category>
		<category><![CDATA[总谐波电流有效值]]></category>
		<category><![CDATA[电流总谐波畸变]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11358</guid>
		<description><![CDATA[THDi(Total Harmonic Current Distortion)定义为总谐波电流有效值 THDI（%）为电流总谐波畸变，定义为一次FT分析的各次谐波电流含量和基波电流有效值比值的百分数。电力负荷基波电流的变化范围是比较... ]]></description>
			<content:encoded><![CDATA[<p>THDi(<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/total-harmonic-current-distortion" title="查看 Total Harmonic Current Distortion 的全部文章" target="_blank">Total Harmonic Current Distortion</a></span>)定义为<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%80%bb%e8%b0%90%e6%b3%a2%e7%94%b5%e6%b5%81%e6%9c%89%e6%95%88%e5%80%bc" title="查看 总谐波电流有效值 的全部文章" target="_blank">总谐波电流有效值</a></span></p>
<p><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/thdi" title="查看 THDI 的全部文章" target="_blank">THDI</a></span>（%）为<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%94%b5%e6%b5%81%e6%80%bb%e8%b0%90%e6%b3%a2%e7%95%b8%e5%8f%98" title="查看 电流总谐波畸变 的全部文章" target="_blank">电流总谐波畸变</a></span>，定义为一次FT分析的各次谐波电流含量和基波电流有效值比值的百分数。电力负荷基波电流的变化范围是比较大，当基波电流较小时，即使计算得到THDI（%）值较大，但实际的谐波电流含量值也较小，此时电力系统受到的威胁并不一定大，这容易给工程技术人员造成一定的误导。</p>
<p>公用电网谐波标准中没有给出任何关于THDI（%）的允许值，实际工程应用中，存在一些错误的认识“THD I（%）&gt;5%就认为用户的谐波电流超标的情况”。</p>
<p>在一些变流器产品标准中也引用了这个标准，比方说逆变器并网点电流总谐波畸变率应小于5%，有源滤波器谐波治理效果应保证系统进线电流总谐波畸变率小于5%，这些场合应用THD I（%）术语均值得商榷。</p>
<p>IEEE Std 519-2014 标准中给出一个TDD I（%）术语，定义为一次FT分析的各次谐波电流含量和负荷（或设备）的最大需量电流比值的百分数。因为负荷（或设备）的需量电流基本是不变化的，建议国内标准和工程应用采用。</p>