<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; MFTK1200</title>
	<atom:link href="http://www.faxytech.com/tag/mftk1200/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>MFK1200与MFTK1400测试12芯光纤MPO极性</title>
		<link>http://www.faxytech.com/archives/12-mpo.html</link>
		<comments>http://www.faxytech.com/archives/12-mpo.html#comments</comments>
		<pubDate>Fri, 20 Apr 2018 10:54:18 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[MFTK1200]]></category>
		<category><![CDATA[MFTK1400]]></category>
		<category><![CDATA[MPO]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=9915</guid>
		<description><![CDATA[12芯光纤MPO极性(MFK1200与MFTK1400测试12芯光纤MPO极性) 要想利用光纤电缆正确地发送数据，电缆一端的链路发送信号(Tx)必须与另一端的接收器(Rx)相匹配。而极性决定信号传播方向，其作用是确保... ]]></description>
			<content:encoded><![CDATA[<p>12芯光纤<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span>极性(MFK1200与<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克MFTK1400">MFTK1400</a></span>测试12芯光纤<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/mpo" title="查看 MPO 的全部文章" target="_blank">MPO</a></span>极性)</p>
<p>要想利用光纤电缆正确地发送数据，电缆一端的链路发送信号(Tx)必须与另一端的接收器(Rx)相匹配。而极性决定信号传播方向，其作用是确保这种对应关系能够被维持。在业内，光纤极性似乎引起很多困扰——尤其是当涉及并行光纤应用中使用的多芯光纤MPO解决方案时。</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2018/04/key-up.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9916" title="key-up" src="http://www.faxytech.com/wp-content/uploads/2018/04/key-up.jpg" alt="" width="423" height="273" /></a></p>
<p>&nbsp;</p>
<h4>01、<strong>MPO组件概览</strong></h4>
<p>&nbsp;</p>
<p>MPO连接器可包含8至72根光纤，其中12芯光纤阵列最常用于企业数据中心应用，例如40和100G。各个连接器要么是公头(针头)，要么是母头(孔头)，以确保配对连接时光纤端面对齐。</p>
<p>MPO连接器在其顶部还具有键槽，并在侧面有1个白点来指示第1个芯孔的位置。键槽的方向对于极性至关重要。</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2018/04/MFTK1400.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9917" title="MFTK1400" src="http://www.faxytech.com/wp-content/uploads/2018/04/MFTK1400.jpg" alt="" width="530" height="253" /></a></p>
<p>&nbsp;</p>
<p>MPO电缆有三种不同类型——A型、B型和C型。A型直通MPO主干电缆，一端的连接器键槽向上，另一端的连接器键槽向下，这样第1个芯孔的光纤对应另一端连接器的第1个芯孔位置。B型电缆两端连接器均为键槽向上，以便第1个芯孔的光纤对应另一端连接器的第12个芯孔位置，第2个芯孔的光纤对应另一端连接器的第11个芯孔位置，依此类推。C型电缆翻转线对，第1个芯孔的光纤对应另一端连接器的第2个芯孔位置，第2个芯孔的光纤对应另一端连接器的第1个芯孔位置。</p>
<p>&nbsp;</p>
<h4>02、<strong>极性方法A</strong></h4>
<p>&nbsp;</p>
<p>方法A采用A型电缆。利用方法A实现双工应用时，需要在一端将收发器-接收器从位置1(Tx)翻转到位置2(Rx)。这通过位于一端的A-A双芯跳线来实现，在设备接口处将第1个芯孔处的光纤移动到第2个芯孔位置，另一端使用A-B跳线。</p>
<p>在40/100 G应用中，在一端使用A型MPO跳线来连接配线架端口和其各自相应的收发器端口，另一端则使用B型MPO跳线。通道内只能存在1根B型跳线。</p>
<p>&nbsp;</p>
<h4>03、<strong>极性方法B</strong></h4>
<p>&nbsp;</p>
<p>方法B采用B型电缆。对于双工应用，方法B在两端均使用A-B双芯跳线，因为无需翻转收发器-接收器。</p>
<p>在40/100 G应用中，在两端均使用B型MPO跳线来连接配线架端口和其各自相应的端口。双工和并行应用中，在两端使用相同类型的跳线，消除了使用哪种类型跳线的顾虑。因此，方法B经常被推荐使用。</p>
<p>&nbsp;</p>
<h4>03、<strong>极性方法C</strong></h4>
<p><img src="data:image/gif;base64,iVBORw0KGgoAAAANSUhEUgAAAAEAAAABCAYAAAAfFcSJAAAADUlEQVQImWNgYGBgAAAABQABh6FO1AAAAABJRU5ErkJggg==" alt="" /></p>
<p>方法C采用C型电缆。对于双工应用，方法C也在两端使用A-B双芯跳线。虽然方法C适用于双工应用，但对于40和100G应用来说却并不理想，因为需要在一端使用复杂的C型MPO交叉跳线。而且，C型电缆和跳线获取不易。</p>
<p>&nbsp;</p>
<h4>04、<strong>极性简化说明表</strong></h4>
<p><a href="http://www.faxytech.com/wp-content/uploads/2018/04/jixing.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-9918" title="jixing" src="http://www.faxytech.com/wp-content/uploads/2018/04/jixing.jpg" alt="" width="506" height="231" /></a></p>
<p>插头类型也很重要。有源设备上的MPO接口为公头(针头)，为避免损坏收发器，MPO跳线应为母头(孔头)。无论选择哪种方法，利用<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span>的MultiFiber? Pro （点击文末 阅读全文 自动进入福禄克网络MultiFiber? Pro 页面），您可以测试各跳线、永久链路和通道的正确极性。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/12-mpo.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>如何利用福禄克MultiFiber Pro测试MPO (MFTK1200,MFTK-SM1310)</title>
		<link>http://www.faxytech.com/archives/multifiber-mpo.html</link>
		<comments>http://www.faxytech.com/archives/multifiber-mpo.html#comments</comments>
		<pubDate>Fri, 02 Sep 2016 02:27:03 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[MFTK-SM1310]]></category>
		<category><![CDATA[MFTK1200]]></category>
		<category><![CDATA[MPO]]></category>
		<category><![CDATA[MultiFiber Pro]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=8006</guid>
		<description><![CDATA[现在在数据中心，MPO光纤已经开始变成一种趋势了。那么如何进行有效的MPO测试呢？在MPO测试中通常接线有三种类型：分为A接法，B接法，C接法。 MPO测试中的A方法 MPO测试中的B方法 &#160; 那么... ]]></description>
			<content:encoded><![CDATA[<p>现在在数据中心，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span>光纤已经开始变成一种趋势了。那么如何进行有效的<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/mpo" title="查看 MPO 的全部文章" target="_blank">MPO</a></span>测试呢？在MPO测试中通常接线有三种类型：分为A接法，B接法，C接法。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/MPO.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8007" title="MPO测试的A方法" src="http://www.faxytech.com/wp-content/uploads/2016/09/MPO.jpg" alt="MPO测试的A方法" width="640" height="203" /></a></p>
<p>MPO测试中的A方法</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/MPO-B.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8008" title="MPO测试中的B方法" src="http://www.faxytech.com/wp-content/uploads/2016/09/MPO-B.jpg" alt="MPO测试中的B方法" width="640" height="189" /></a></p>
<p>MPO测试中的B方法</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/MPO-C.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8009" title="MPO测试的C方法" src="http://www.faxytech.com/wp-content/uploads/2016/09/MPO-C.jpg" alt="MPO测试的C方法" width="640" height="199" /></a></p>
<p>&nbsp;</p>
<p>那么，有没有一种简单快速的办法，能够高效的完成 MPO 光纤测试呢？那就要请出我们今天的主角——MPO 测试的喀秋莎——<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="MultiFiber Pro">MultiFiber Pro</a></span>：</p>
<p><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/multifiber-pro" title="查看 MultiFiber Pro 的全部文章" target="_blank">MultiFiber Pro</a></span> 可以用来快速认证包含8根、10根或者12根多模光纤的 MPO 链路，并且可以自动识别并报告极性类别。本文将为您介绍在 MPO 光纤两端使用 MultiFiber Pro 认证 MPO 光纤的方法。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/MPO1.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8010" title="MPO" src="http://www.faxytech.com/wp-content/uploads/2016/09/MPO1.jpg" alt="" width="522" height="116" /></a></p>
<p>在涉及测试跳线时，MultiFiber Pro有个很大的好处是不挑跳线，您可以使用B型跳线来测试A型链路，反之也可，这同样也适用于C型链路。此外，如果您只用12根光纤中的8根来支持 40GBASE-SR4，或者只用10根来支持 100GBASE-SR10，MultiFiber Pro 将会自动将其识别为有效的链路，即使未使用的光纤不存在，也不会认为链路是有故障的，如下图所示：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/40GMPO.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8011" title="40GMPO" src="http://www.faxytech.com/wp-content/uploads/2016/09/40GMPO.jpg" alt="" width="616" height="350" /></a></p>
<p><strong>您将会用到以下设备：</strong></p>
<p>- <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MFTK1200">MFTK1200</a></span></p>
<p>- 公对公 MPO 1米测试跳线 （2根）（注意：使用母头测试跳线插入光源或光功率计将会导致不稳定的读数）</p>
<p>- MPO 背靠背适配器</p>
<p>&nbsp;</p>
<p>此外，仔细的光纤端面检查在这项工作中是极其重要的，没有检查这个环节，您将会得到较差或不可预测的测试结果。USB FI-1000 光纤端面检查仪 (下图所示) 自带了检查 MPO 适配器的配件，您可以通过插入到 <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> 平台来使用。</p>
<p>&nbsp;</p>
<h4><strong>测试极限值</strong></h4>
<p>您需要计算所测链路的预期损耗值，并将此输入到 MultiFiber Pro。我们无法告诉您什么是合适的测试极限值，您必须咨询布线系统的设计者，有关于测试极限值应用的信息可以在<a title="Click here to download the test limits document" target="_blank">Versiv 测试极限值文档中</a>查到。</p>
<h4><strong>输入测试极限值</strong></h4>
<p>1、按F3键来选择所需的波长。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/0.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8012" title=" MultiFiber Pro" src="http://www.faxytech.com/wp-content/uploads/2016/09/0.gif" alt=" MultiFiber Pro" width="200" height="251" /></a></p>
<p>2、长按MENU/SELECT（菜单/选择）大约3秒，等待显示。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/menu.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8013" title="menu-MultiFiber Pro" src="http://www.faxytech.com/wp-content/uploads/2016/09/menu.jpg" alt="menu-MultiFiber Pro" width="206" height="267" /></a></p>
<p>3、按F1键来移动光标至LOSS LIMIT（损耗极限）。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/LOSS-mulitFIber.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8014" title="LOSS-mulitFIber" src="http://www.faxytech.com/wp-content/uploads/2016/09/LOSS-mulitFIber.png" alt="" width="200" height="251" /></a></p>
<p>4、按MENU/SELECT（菜单/选择）键进行选择。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/select-multifiber.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8015" title="select-multifiber" src="http://www.faxytech.com/wp-content/uploads/2016/09/select-multifiber.jpg" alt="" width="210" height="261" /></a></p>
<p>5、使用F1和F2键来改变dB值，与您的要求匹配。</p>
<p>6、完成后点击MENU/SELECT（菜单/选择）保存。</p>
<p>7、再次长按MENU/SELECT（菜单/选择）大约三秒，退出设置菜单。</p>
<p>&nbsp;</p>
<h4><strong>进行测量</strong></h4>
<p>1、打开光源和光功率计，并且让它们稳定运行至少5分钟，如果仪器一直在同一<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>的测试区域内存放，那么五分钟的时长已经足够。如果仪器存放的区域和使用测试的区域有着明显的温差，那么您就需要让仪器稳定运行更长的时间。我们将会在第六步对光源的稳定性进行检查。</p>
<p>2、使用第一根公对公 MPO 测试跳线，将光源和光功率计连接在一起。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/pinned-multifiber.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8016" title="pinned-multifiber" src="http://www.faxytech.com/wp-content/uploads/2016/09/pinned-multifiber.gif" alt="" width="334" height="324" /></a></p>
<p>&nbsp;</p>
<p>3、正常的情况下，您可以在光功率计屏幕上看到所有12个通道都有5根表示强度的横线，最多不应该少于4根。如果在某一个通道上只有3根或者更少，说明这根测试跳线已经不能用，应该换根新的。同时 MultiFiber Pro 的测试端口也需要清洁。如果您坚持使用不良的测试跳线，那么测试结果将无法确保准确。</p>
<p>4、点击 MENU/SELECT（菜单/选择）键，您将会在屏幕上看到 SET REF（设置参考值）。（参考值设置将会自动开始）</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/set-multifiber-pro.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8017" title="set-multifiber-pro" src="http://www.faxytech.com/wp-content/uploads/2016/09/set-multifiber-pro.gif" alt="" width="200" height="293" /></a></p>
<p>5、完成后，SAVE（保存）将会出现在F1键的上方，按下F1键，屏幕上将会显示0.00 dB。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/pinned-multifiber-2.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8018" title="pinned-multifiber-2" src="http://www.faxytech.com/wp-content/uploads/2016/09/pinned-multifiber-2.gif" alt="" width="334" height="324" /></a></p>
<p>6、保持测试跳线不断开，观测光源的稳定性大约30秒，如果您看到损耗值有所改变，重复第四步，直到您得到一个稳定的读数。</p>
<p>7、从光功率计一端断开连接：（不要从光源断开连接）</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-7.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8019" title="multifiber-7" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-7.gif" alt="" width="576" height="209" /></a></p>
<p>8、使用极性对调工具，将#1测试跳线由公头改为母头：（不要换测试跳线）</p>
<p><img src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-7.gif" alt="" width="576" height="209" /></p>
<p>9、在光功率计上，插入第二根公对公 MPO测试跳线：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-9.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8020" title="multifiber-9" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-9.gif" alt="" width="576" height="209" /></a></p>
<p>10、连接光源和光功率计，确保所有通道的损耗值不超过0.35dB：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-11.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8021" title="multifiber-11" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-11.gif" alt="" width="467" height="334" /></a></p>
<p>11、断开光源和光功率计的连接：</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-11-2.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8022" title="multifiber-11-2" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-11-2.gif" alt="" width="576" height="209" /></a></p>
<p>12、使用极性对调工具，将#2测试跳线由公头改为母头：（不要换测试跳线）</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-12.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8023" title="multifiber-12" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-12.gif" alt="" width="576" height="209" /></a></p>
<p>13、连接想要认证的链路。在6秒后，所有的12根光纤的光损耗都会被测量。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-131.gif" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-8025" title="multifiber-13" src="http://www.faxytech.com/wp-content/uploads/2016/09/multifiber-131.gif" alt="" width="576" height="222" /></a></p>
<p>14、点击F1来保存您的结果。（所有的12根光纤的结果将会被同时保存）</p>
<p>&nbsp;</p>
<p><strong>特别提示</strong></p>
<p>- 当您浏览LOSS(损耗)时，每个横线代表着您输入的测试极限值的25%。</p>
<p>- 损耗值的读数小于-0.09将会导致测试失败，如果此情况发生，便说明您的光源不稳定，请重新设置参考。</p>
<p>- MPO测试跳线应该经常的检查和更换，供应商建议多模 MPO/MTPs的测试跳线的标准寿命在500至1000次的拔插之间。</p>
<p>- MultiFiber Pro将会保存3000根光纤的损耗结果。</p>
<p>- 测试结果可以通过USB线传输到<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span> PC端。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/multifiber-mpo.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>【福禄克】Fluke MultiFiber Pro 光功率计及光纤测试工具包(MFTK1200,MFTK1400)</title>
		<link>http://www.faxytech.com/archives/multifiber-pro.html</link>
		<comments>http://www.faxytech.com/archives/multifiber-pro.html#comments</comments>
		<pubDate>Thu, 06 Sep 2012 03:17:02 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[福禄克光缆测试产品]]></category>
		<category><![CDATA[MFTK1200]]></category>
		<category><![CDATA[MFTK1400]]></category>
		<category><![CDATA[MPO]]></category>
		<category><![CDATA[MultiFiber Pro 光功率计及光纤测试工具包]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=2283</guid>
		<description><![CDATA[福禄克FLuke MultiFiber Pro (MFTK1200,MFTK1400)光功率计及光纤测试工具包，第一个用于 MPO 光纤自动测试的仪器。 【福禄克】Fluke MultiFiber Pro 光功率计及光纤测试工具包(MFTK1200,MFTK1400)概览 自动扫描和... ]]></description>
			<content:encoded><![CDATA[<p>福禄克FLuke <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="MultiFiber Pro">MultiFiber Pro</a></span> (<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MFTK1200">MFTK1200</a></span>,<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克MFTK1400">MFTK1400</a></span>)光功率计及光纤测试工具包，第一个用于 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/multifiber-pro.html" title="福禄克Fluke MPO">MPO</a></span> 光纤自动测试的仪器。</p>
<h4>【福禄克】Fluke <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/multifiber-pro-%e5%85%89%e5%8a%9f%e7%8e%87%e8%ae%a1%e5%8f%8a%e5%85%89%e7%ba%a4%e6%b5%8b%e8%af%95%e5%b7%a5%e5%85%b7%e5%8c%85" title="查看 MultiFiber Pro 光功率计及光纤测试工具包 的全部文章" target="_blank">MultiFiber Pro 光功率计及光纤测试工具包</a></span>(<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/mftk1200" title="查看 MFTK1200 的全部文章" target="_blank">MFTK1200</a></span>,<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/mftk1400" title="查看 MFTK1400 的全部文章" target="_blank">MFTK1400</a></span>)概览</h4>
<ul>
<li>自动扫描和测试 <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/mpo" title="查看 MPO 的全部文章" target="_blank">MPO</a></span> 连接器中的所有光纤</li>
<li>使用内置的极性验证功能确保 MPO 光纤主干线端对端连接的正确性</li>
</ul>
<ul>
<li>板载 MPO 连接器消除了测试光纤主干线时使用扇形跳线的需求</li>
</ul>
<ul>
<li>用一个界面简单显示所有 12 光纤，轻松解读测试结果</li>
<li>使用深入查看单条光纤测试结果的功能排除 MPO 链路的故障</li>
<li>遮蔽式 MPO 连接器，无需外配防尘盖</li>
</ul>
<h4>【福禄克】Fluke MultiFiber Pro 光功率计及光纤测试工具包(MFTK1200,MFTK1400)特性</h4>
<p><a href="http://www.faxytech.com/wp-content/uploads/2012/09/Fn-MultiFiberPro_01a_.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="alignright size-full wp-image-2285" title="福禄克Fluke MultiFiberPro" src="http://www.faxytech.com/wp-content/uploads/2012/09/Fn-MultiFiberPro_01a_.jpg" alt="福禄克Fluke MultiFiberPro" width="275" height="222" /></a>介绍 MultiFiber? Pro 光功率计和光纤测试工具包。MultiFiber Pro 是仅有的、不使用扇形跳线来测试 MPO 光缆的测试仪，它使极性验证不再复杂，并可使MPO卡盒更容易进行现场测试。无论是使用10预端接光缆，还是计划使用新一代40/100 Gbps 性能，数据中心正使 MPO 连接器成为标准的解决方案。典型的数据中心光纤安装意味着耗时、手动及不精确的 MPO 验证。MultiFiber Pro 比单光纤测试法的速度快百分之 90，因为其只对单个连接器中的12 光纤进行功率损耗测量和极性验证— 可将测试时间从几周减少为几天。</p>
<div id="12590q">
<h3><strong>“全部扫描”功能</strong></h3>
</div>
<div id="12590a">
<p>MultiFiber Pro 功率计中的“全部扫描”功能可自动扫描和测试所有 12 MPO 连接器中的光纤 – 只需 6 秒就可完成所有损耗和功率测量工作。此功能可在使用扇形跳线时自动测试 MPO 终端光纤，避免了在光纤间移动<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/fiber" title="光纤测试仪">光纤测试仪</a></span>的过程和时间消耗。</p>
</div>
<div id="12591q">
<h3><strong>内置极性验证</strong></h3>
</div>
<div id="12591a">
<p>任何极性方案的目的就是为了提供一个链路发送器到链路接收器间的不间断连接。对于阵列式连接器，TIA-568-C.0 定义了 3 种方法实现此目的：方法 A、B 和 C。部署错误十分常见，因为这些方法需要将不同极性的跳接线组合起来使用。为了确保极性正确，MultiFiber Pro 允许用户测试单条跳线、永久链路和通道。</p>
</div>
<div id="12592q">
<h3><strong>板载 MPO 测试适配器</strong></h3>
</div>
<div id="12592a">
<p>在光功率计和光源上均配有 MPO 连接器，无需使用昂贵、复杂的扇形跳线即可测试 MPO 光纤。</p>
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/On-board%20MPO%20Connector.JPG" alt="" /></p>
</div>
<div id="12593q">
<h3><strong>简洁的用户界面</strong></h3>
</div>
<div id="12593a">
<p>MultiFiber Pro 在简洁地同时显示12 光纤极性、功率和损耗测试结果方面做得非常成功，因此该用户界面正在申请专利。该功率计可轻松地让用户同时了解 12 多根光纤的测量结果。光源显示的是每条 MPO 连接器中正在测试的光纤。任何一个不满足测试极限值的测量值均被明确指出，以便进行根本原因分析。这个功能强大、操作简单的测试工具可让每个人都成为光纤测试的专家，提高测试数据中心项目的效率。</p>
</div>
<div id="12594q">
<h3><strong>选择单条光纤</strong></h3>
</div>
<div id="12594a">
<p>数据中心的主要问题之一，是在测试和故障排除期间是否能够详细了解单条光纤的情况。MultiFiber Pro 可对 MPO 光缆中的单条光纤进行故障诊断并提供单条光纤的测试结果。此功能可通过更精确的单条光纤数据和报告，提高 MPO 连接器验证和故障排除的灵活性。</p>
</div>
<div id="12595q">
<h3><strong>板载遮蔽式 MPO 连接器</strong></h3>
</div>
<div id="12595a">
<p>无保护罩的端口会使布线、设备和测试仪存在受污染的危险，从而影响性能。在测试仪上使用带遮蔽式保护罩的连接件可以防尘。通过关闭 MPO 连接器端口，MultiFiber Pro 为您提供更高的测试可靠性，使您更加安心。</p>
</div>
<div id="12596q">
<h3><strong>轻松的报告</strong></h3>
<p>MultiFiber Pro 功率计内部最多可存储 3,000 个测试结果（相当于 250 条 MPO 线缆），可上传至运行 <span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>? 7 电缆测试管理软件的 PC 上。LinkWare 7 可以管理测试结果、编辑线缆 ID、打印专业报告，甚至可将数据导出为电子表格格式。</p>
</div>
<div id="12596a">
<p><img src="http://cn.flukenetworks.com/sites/flukenetworks.com/files/assets/Easy%20Reporting.JPG" alt="" /></p>
</div>
<p><a name="12597"></a></p>
<div id="12597q">
<div><strong>满足各种需要的工具包</strong></div>
<div>MultiFiber Pro 拥有多个方便的工具包配置，可满足您所有的清洁、检查和验证测试需求。工具包包括：</div>
<p>光纤检查 – <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/fiberinspector-mini.html" title="FiberInspector 袖珍光纤视频显微镜">FiberInspector</a></span>? Pro。 T光纤显微镜是终级的可视检查工具。其 3.5” 屏幕可通过双倍探头提供更大的图像。小的探头可握在手掌中，通过旋转拨盘在放大 250x 和 400x 倍间进行切换。FiberInspector Pro 及可选的 MPO 端头是对 MultiFiber Pro 测试组件的补充附件，可为 MPO 已连接光纤和磁带的清洁、检查和测试提供一个全面的套件。</p>
<p>光纤清洁 – IBC? 一键式清洁器，清洁工作非常重要。<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="Fluke Networks">Fluke Networks</a></span> 的一键式清洁器可立即清洁连接器内的光纤端面。只需推动工具端头即可进行清洁操作，并用转轮回位 – 就这么简单。MPO 一键式清洁器是与 MultiFiber Pro 工具包绑定在一起的，确保您在一开始就拥有最好的清洁工具。</p>
</div>
<h4>【福禄克】Fluke MultiFiber Pro 光功率计及光纤测试工具包(MFTK1200,MFTK1400)规格</h4>
<div>
<table id="SpecTable1" border="0" cellspacing="0">
<tbody>
<tr>
<td colspan="2"><strong>一般规格</strong></td>
</tr>
<tr>
<td>工作<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span></td>
<td>-10?C 至 +50?C</td>
</tr>
<tr>
<td>贮存温度</td>
<td>-20?C 至 +50?C&lt; 10?C</td>
</tr>
<tr>
<td>工作湿度</td>
<td>95 %（10?C 至 +35?C）无冷凝<br />
75 %（35?C 至 +45?C）无冷凝<br />
不受控制 &lt; 10° C</td>
</tr>
<tr>
<td>操作高度</td>
<td>4,000 米</td>
</tr>
<tr>
<td>存储高度</td>
<td>12,000 米</td>
</tr>
<tr>
<td>振动</td>
<td>随机，2 G，5 Hz 至 500 Hz</td>
</tr>
</tbody>
</table>
<table id="SpecTable2" border="0" cellspacing="0">
<tbody>
<tr>
<td colspan="2"><strong>光功率计（规定在 23?C (73?F) 条件下使用，除非另有说明）</strong></td>
</tr>
<tr>
<td>检测器类型</td>
<td>InGaAs</td>
</tr>
<tr>
<td><span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克校准">校准</a></span>波长</td>
<td>850 nm、1300 nm、1310 nm、1550 nm</td>
</tr>
<tr>
<td>测量范围</td>
<td>0 dBm 至 -50 dBm</td>
</tr>
<tr>
<td>功率测量线性度</td>
<td>±0.1 dB<sup>1</sup></td>
</tr>
<tr>
<td>功率测量的不确定性</td>
<td>±0.35 dB</td>
</tr>
<tr>
<td>功率测量的可重复性</td>
<td>&lt; 0.10 dB</td>
</tr>
<tr>
<td>显示分辨率，dB 或 dBm</td>
<td>0.01 dB</td>
</tr>
<tr>
<td>功率显示单位</td>
<td>dBm、mW、μW</td>
</tr>
<tr>
<td>用户可选的损耗极限</td>
<td>0.05 dB 至 50.0 dB，增量为0.05 dB ，最高可达 10.0 dB，及增量为0.1 dB，最高可达 50.0 dB</td>
</tr>
<tr>
<td>自动波长检测</td>
<td>是</td>
</tr>
<tr>
<td>极性检测</td>
<td>检测 A、B、C 及 Corning Plug &amp; Play? 通用系统的极性</td>
</tr>
<tr>
<td>2 kHz 检测</td>
<td>是</td>
</tr>
<tr>
<td>记录存储</td>
<td>3000 个记录，每个记录一条光纤（250 12 芯光缆）</td>
</tr>
<tr>
<td>外部接口</td>
<td>USB 2.0，全速</td>
</tr>
<tr>
<td>光学连接器</td>
<td>12 芯光纤 MPO 接口，无插脚插头。兼容 50 μm 和单模光纤。连接器有一个自动关闭的保护罩。</td>
</tr>
<tr>
<td>电源需求</td>
<td>2 AA 碱性电池</td>
</tr>
<tr>
<td>电池寿命<sup>2</sup></td>
<td>&gt;30 小时（典型）</td>
</tr>
<tr>
<td>自动关闭</td>
<td>10、20、30 或 60 分钟（可由用户禁用）</td>
</tr>
<tr>
<td>低电量警告</td>
<td>电量低图标闪烁</td>
</tr>
<tr>
<td>尺寸大小</td>
<td>5.7 英寸 x 3.2 英寸 x 1.5 英寸（14.5 厘米 x 8.0 厘米 x3.9 厘米）</td>
</tr>
<tr>
<td>重量</td>
<td>10.9 盎司 (g)309</td>
</tr>
</tbody>
</table>
<table id="SpecTable3" border="0" cellspacing="0">
<tbody>
<tr>
<td colspan="2"><strong>850nm 光源（规定在 23?C (73?F) 条件下使用，除非另有说明）</strong></td>
</tr>
<tr>
<td>发射器类型</td>
<td>LED:850 nm</td>
</tr>
<tr>
<td>波长</td>
<td>850 nm ：±30 nm</td>
</tr>
<tr>
<td>谱宽 (FWHM)</td>
<td>850 nm ：±50 nm（典型值）</td>
</tr>
<tr>
<td>输出功率</td>
<td>850 nm ：≥ 24 dBm 通道间的最大差异 +/-1dB</td>
</tr>
<tr>
<td>功率输出稳定性<sup>3</sup></td>
<td>≤ ±0.1 dB 超过 8 小时</td>
</tr>
<tr>
<td>环型通量</td>
<td>在光源光学连接器为50/125 μm 时，符合 ANSI/TIA-526-14B、ISO/IEC 14763-3 和 IEC 61280-4-1。</td>
</tr>
<tr>
<td>光学连接器</td>
<td>12 芯光纤 MPO 接口，无插脚插头。兼容 62.5 μm 和 50 μm。</td>
</tr>
<tr>
<td>模式</td>
<td>2 kHz 已调制，自动波长</td>
</tr>
<tr>
<td>电源需求</td>
<td>2 AA 碱性电池</td>
</tr>
<tr>
<td>电池寿命<sup>4</sup></td>
<td>&gt;30 小时（典型）</td>
</tr>
<tr>
<td>自动关闭</td>
<td>10、20、30 或 60 分钟（可由用户禁用）</td>
</tr>
<tr>
<td>低电量警告</td>
<td>电量低图标闪烁</td>
</tr>
<tr>
<td>尺寸大小</td>
<td>5.6 英寸 x 3.2 英寸 x 1.6 英寸（14.2 厘米 x 8.1 厘米 x4.1 厘米）</td>
</tr>
<tr>
<td>重量</td>
<td>10.9 盎司 (g)309</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<ol>
<li>对于 850 nm，为 0 dBm 至 -50 dBm。对于 1300、1310、1550 nm，为 -5 至 -50 dBm</li>
<li>测量的功率级 ≤0 dBm。背景灯打开。电池的寿命取决于所用电池的状态和类型。Fluke Networks 推荐使用碱性电池</li>
<li>23°C ± 2°C，10 分钟预热时间之后</li>
<li>自动波长，全部扫描并且背景灯打开。电池的寿命取决于所用电池的状态和类型。Fluke Networks 推荐使用碱性电池</li>
</ol>
</div>
<h4>【福禄克】Fluke MultiFiber Pro 光功率计及光纤测试工具包(MFTK1200,MFTK1400)产品选型</h4>
<div>型号</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>MFTK1200</td>
<td>MultiFiber Pro 测试基本工具包包括 MultiFiber Pro 光功率计、850光源、测试跳线、 MPO 适配器和便携箱</td>
</tr>
<tr>
<td>MFTK1400</td>
<td>MultiFiber Pro 测试和检查工具包包括 MFTK1200、FT600 FiberInspector Pro 和 NF370 MPO 端头</td>
</tr>
</tbody>
</table>
<div>零配件</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>MFPOWERMETER</td>
<td>MultiFiber Pro 光功率计</td>
</tr>
<tr>
<td>MFMULTIMODESOURCE</td>
<td>MultiFiber Pro 多模850 LED 光源</td>
</tr>
<tr>
<td>NFC-IBC-1.25mm</td>
<td>适用于1.25 mm LC 和 MU 连接器及跳接线的一键式清洁器（5 数量）</td>
</tr>
<tr>
<td>NFC-IBC-2.5mm</td>
<td>适用于2.5 mm SC、ST、FC 连接器和跳线的一键式清洁器（5 数量）</td>
</tr>
<tr>
<td>NFC &#8211; IBC &#8211; MPO</td>
<td>适用于 MPO/MPO 连接器的一键式清洁器（5 数量）</td>
</tr>
<tr>
<td>NFC-Kit-Case-E</td>
<td>增强型光纤清洁工具包 – 包含一个用于 1.25mm 连接器的一键式清洁器、一个用于 2.5mm 连接器的一键式清洁器、一个用于 MPO/MPO? 清洁的一键式清洁器、一支溶剂笔、一个清洁管和一个软包</td>
</tr>
<tr>
<td>FT600</td>
<td>FiberInspector Pro</td>
</tr>
<tr>
<td>NF370</td>
<td>FT600 MPO FT600光纤显微镜探尖适配器</td>
</tr>
<tr>
<td>TRC-MPO-PP-B</td>
<td>MPO/MPO 1 米测试跳线 ，带插脚/带插脚，B 型极性</td>
</tr>
<tr>
<td>TRC-MPO-UP-B</td>
<td>MPO/MPO 1 米测试跳线，无插脚/带插脚，B 型极性</td>
</tr>
<tr>
<td>TRC-MPO-UU-B</td>
<td>MPO/MPO 0.3 米测试跳线，无插脚/无插脚，B 型极性</td>
</tr>
<tr>
<td>BKC-MPO-ULC</td>
<td>MPO 无插脚 LC 连接器 1 m 扇形跳线</td>
</tr>
<tr>
<td>BKC-MPO-USC</td>
<td>MPO 无插脚 SC 连接器 1 m 扇形跳线</td>
</tr>
<tr>
<td>ADP-MPO-B</td>
<td>B 型极性 MPO 适配器</td>
</tr>
</tbody>
</table>
<div>支持</div>
<table cellpadding="5" width="100%">
<tbody>
<tr>
<td width="160">型号/名称</td>
<td>说明</td>
</tr>
<tr>
<td>GLD-MF</td>
<td>MFPOWERMETER/MFMULTIMODESOURCE 1 年金牌支持</td>
</tr>
<tr>
<td>GLD-MFTK</td>
<td>MFTK1200、MFTK1400 1 年金牌支持</td>
</tr>