<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; DSX2-5000</title>
	<atom:link href="http://www.faxytech.com/tag/dsx2-5000/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>福禄克网线测试仪DSX2-5000与DSX2-8000的区别大PK</title>
		<link>http://www.faxytech.com/archives/dsx5000-dsx8000.html</link>
		<comments>http://www.faxytech.com/archives/dsx5000-dsx8000.html#comments</comments>
		<pubDate>Sun, 07 Mar 2021 01:59:29 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[福禄克网线测试]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11925</guid>
		<description><![CDATA[在福禄克众多的铜缆测试设备中，认证级的设备有3款，分别是DSX-600，Versiv DSX2-5000，Versiv DSX2-8000。DSX2-5000与DSX2-8000作为福禄克DSX2 CableAnalyzer系列的两款拳头产品，被誉为网络测试界的扛把子。... ]]></description>
			<content:encoded><![CDATA[<p>在<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b" title="查看 福禄克 的全部文章" target="_blank">福禄克</a></span>众多的<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="铜缆测试仪">铜缆</a></span>测试设备中，认证级的设备有3款，分别是<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-600.html" title="福禄克DSX-600">DSX-600</a></span>，<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> <span class='wp_keywordlink'><a href="http://www.faxy-tech.com/Products/DSX2-5000.html" title="福禄克FLUKE DSX2-5000">DSX2-5000</a></span>，Versiv <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx2-8000.html" title="福禄克FLUKE DSX2-8000">DSX2-8000</a></span>。<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx2-5000" title="查看 DSX2-5000 的全部文章" target="_blank">DSX2-5000</a></span>与<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx2-8000" title="查看 DSX2-8000 的全部文章" target="_blank">DSX2-8000</a></span>作为福禄克DSX2 CableAnalyzer系列的两款拳头产品，被誉为网络测试界的扛把子。现在对<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%a6%8f%e7%a6%84%e5%85%8b%e7%bd%91%e7%ba%bf%e6%b5%8b%e8%af%95" title="查看 福禄克网线测试 的全部文章" target="_blank">福禄克网线测试</a></span>仪DSX2-5000与DSX2-8000功能做个大PK，方便大家选择更适合的仪器。</p>
<h4>
<strong>福禄克网线测试仪DSX2-5000与DSX2-8000相同之处：</strong></h4>
<p>TCL和ELTCL不平衡测量都能测试；DSX2 CableAnalyzer系列（DSX2-5000和DSX2-8000）仍然是可执行以下测量的现场<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/cable" title="电缆测试仪">电缆测试仪</a></span>：电阻不平衡：这对PoE的运行成功很重要,TCL和ELTCL不平衡测量：这对10GBase-T的成功运行很重要。</p>
<p>测试电缆屏蔽层连通性技术一样：DSX2-5000和DSX2-8000采用更成熟的方法，测定“电缆通路中”屏蔽层的连通性。它也可以显示到屏蔽故障的距离，从而大幅简化了故障排除。</p>
<p>外观设计一样：同属于Versiv 系列的框架和远端。配备可插拔的测试模块；<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dtx-patchcord-adapter.html" title="跳线适配器">跳线适配器</a></span>可以通用的：DSX2-5000上超五类跳线适配器和六类跳线适配器,超六类跳线适配器可以在DSX2-8000上通用；</p>
<p>&nbsp;</p>
<h4>福禄克网线测试仪DSX2-5000与DSX2-8000不同之处：</h4>
<p><strong>测试速度：</strong></p>
<p>DSX2-8000是市场上超快的测试仪，6A类认证只需八秒，8类的测试时间16秒；</p>
<p>DSX2-5000：6A比6类的测试速度快个一二秒，差不多9-10秒；</p>
<p><strong>测试类别上</strong>：</p>
<p>DSX2-8000可测试DSX2-5000能测试的所有铜缆布线类型,是目前超高的八类测试仪,可测2GHZ;<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span>是测1GHZ；</p>
<p><strong>成本上来说：</strong></p>
<p><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx8000.html" title="福禄克FLUKE DSX-8000">DSX-8000</a></span>比DSX-5000稍贵一些。</p>
<p>配件不能通用的：DSX-5000的七类GG45和TERA通道适配器和链璐适配器与DSX-8000并不能通用;DSX-8000仪器上的八类的通道和是不能在DSX-5000上使用的。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx5000-dsx8000.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克FLUKE DSX2-5000便携式网络测试仪</title>
		<link>http://www.faxytech.com/archives/dsx5000-pxs.html</link>
		<comments>http://www.faxytech.com/archives/dsx5000-pxs.html#comments</comments>
		<pubDate>Tue, 02 Mar 2021 02:04:54 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[便携式网络测试仪]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11908</guid>
		<description><![CDATA[便携式网络测试仪 （一）设备用途和数量 本设备用于磁山机务折返段机车用于机车MVB、WTB网络使用网线的电气参数检测。 （二）适用环境 适应温度:室外-30℃~+45 ℃ 相对湿度：≤95% 海拔高度... ]]></description>
			<content:encoded><![CDATA[<p><strong>便携式网络测试</strong><strong>仪</strong><strong> </strong></p>
<p><strong>（一）设备用途和</strong><strong>数量</strong><strong> </strong></p>
<p>本设备用于磁山机务折返段机车用于机车MVB、WTB网络使用网线的电气参数检测。</p>
<p><strong>（二）适用环境</strong><strong> </strong></p>
<p>适应<span class='wp_keywordlink'><a href="http://www.faxytech.com/products/testers/temp" title="温度测试">温度</a></span>:室外-30℃~+45 ℃</p>
<p>相对湿度：≤95%</p>
<p>海拔高度：≤2000m</p>
<p><strong>（三）设备组成</strong><strong>及</strong><strong>功能</strong><strong> </strong></p>
<p>3.1 设备组成</p>
<p>便携式机车网络检测设备主要由测试主机、YXM12适配模块、YXT跳线模块、通道适配器、分析软件等部分组成。设备应用采用成熟的、模块化设计，具有便携式结构特点。</p>
<p>YXM12适配模块用于4芯列车MVB总线测试。</p>
<p>通道适配器用于8芯列车MVB及WTB总线测试。</p>
<p>YXT跳线模块用于不同车型的网络线缆的跳线转接，以保证其测试网络的准确对应。</p>
<p>3.2设备功能</p>
<p>（1）设备应能实现机车CCU、CIO、MIO、HMI、IDU、TCU、BCU等部件采用之间的MVB或WTB总线测试。</p>
<p>（2）设备应能实现对机车WTB及MVB网络线长度、电阻值、接线图的检测。</p>
<p>（3）设备测试结果可实现直观显示，采用模块化结构设计，适应不同形式的网络线缆测试，易于扩展。</p>
<p>（4）设备具备检测数据的转储上传功能，并可通过后台软件进行数据的分析、处理。</p>
<p><strong>（四）主要技术</strong><strong>参数</strong><strong> </strong></p>
<table>
<tbody>
<tr>
<td colspan="2" width="553" valign="top"><strong>线缆类型</strong><strong> </strong></td>
</tr>
<tr>
<td width="127" valign="top">有屏蔽和无屏蔽的双绞 LAN 布线：</td>
<td width="425" valign="top">TIA 类别3、4、5、5e、6、6A：100 Ω ISO/IEC Class C、D、E、EA、F 和 FA：100Ω 和 120Ω</td>
</tr>
<tr>
<td colspan="2" width="553" valign="top"><strong>标准链路接口适配器</strong><strong> </strong></td>
</tr>
<tr>
<td rowspan="2" width="127" valign="top">永久链路适配器</td>
<td width="425" valign="top">插头类型：屏蔽的 RJ45</td>
</tr>
<tr>
<td width="425" valign="top">可选插头类型：Tera</td>
</tr>
<tr>
<td rowspan="2" width="127" valign="top">通道适配器</td>
<td width="425" valign="top">插孔类型：屏蔽的 RJ45</td>
</tr>
<tr>
<td width="425" valign="top">可选插孔类型：Tera</td>
</tr>
<tr>
<td colspan="2" width="553" valign="top"><strong>测试标准</strong><strong></strong></td>
</tr>
<tr>
<td width="127" valign="top">TIA</td>
<td width="425" valign="top">符合 TIA 568-C.2 要求的类别 3、4、5、5e、6、 6A</td>
</tr>
<tr>
<td width="127" valign="top">ISO/IEC</td>
<td width="425" valign="top">符合 ISO/IEC 11801:2002 和修订版要求的 Class C 和 D、E、Ea、F、FA</td>
</tr>
<tr>
<td width="127" valign="top">最大频率</td>
<td width="425" valign="top">1200 MHz</td>
</tr>
<tr>
<td colspan="2" width="553" valign="top"><strong>一般规格</strong><strong></strong></td>
</tr>
<tr>
<td width="127" valign="top">自动测试速度</td>
<td width="425" valign="top">类别 5e 或 6/Class D 或 E 的全双向自动测试：9 秒 类别 6A/Class EA 的全双向自动测试：10 秒</td>
</tr>
<tr>
<td width="127" valign="top">支持测试参数（测试参数及测试的频率范围由所选择的测试标准决定）</td>
<td width="425" valign="top">布线图，长度，传播延迟，延迟偏差，直流回路电阻，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>（<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>），回程损耗 (RL)，<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>，衰减串扰比 (<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span>)，<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span> (ELFEXT)，Power Sum ACR-F (ELFEXT)，Power Sum NEXT，Power Sum ACR-N，Power Sum Alien Near End Xtalk (PS ANEXT)，Power Sum Alien <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="Attenuation">Attenuation</a></span> Xtalk Ratio Far End (PS AACR-F)</td>
</tr>
<tr>
<td width="127" valign="top">输入保护</td>
<td width="425" valign="top">能经受持续的电话电压和 100 mA 的过流。在 ISDN 上偶尔发生超压现象不会造成损坏</td>
</tr>
<tr>
<td width="127" valign="top">显示屏</td>
<td width="425" valign="top">5.7 英寸 LCD，具有感应电容触摸屏</td>
</tr>
<tr>
<td width="127" valign="top">箱包</td>
<td width="425" valign="top">由减震材料包覆成型的耐冲击性塑料箱</td>
</tr>
<tr>
<td width="127" valign="top">体积</td>
<td width="425" valign="top">已安装 <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx-5000.html" title="福禄克FLuke DSX-5000">DSX-5000</a></span> 模块和电池的主 <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/fluke-versiv.html" title="福禄克FLuke Versiv">Versiv</a></span> 装置：2.625 英寸 x 5.25 英寸 x 11.0 英寸（6.67 厘米 x 13.33 厘米 x27.94 厘米）</td>
</tr>
<tr>
<td width="127" valign="top">重量</td>
<td width="425" valign="top">已安装 DSX-5000 模块和电池的主 Versiv 装置：3 磅，5 盎司 (1.28 kg)</td>
</tr>
<tr>
<td width="127" valign="top">主机与远端</td>
<td width="425" valign="top">锂离子电池组，7.2 V</td>
</tr>
<tr>
<td width="127" valign="top">典型的电池寿命</td>
<td width="425" valign="top">8小时</td>
</tr>
<tr>
<td width="127" valign="top">充电时间*</td>
<td width="425" valign="top">测试仪关：电量从 10% 充到 90 % 需 4 小时</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx5000-pxs.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>福禄克FLUKE DSX2-8000或者DSX2-5000进入工程模式给版本降级</title>
		<link>http://www.faxytech.com/archives/dsx-soft-update.html</link>
		<comments>http://www.faxytech.com/archives/dsx-soft-update.html#comments</comments>
		<pubDate>Tue, 13 Oct 2020 05:27:24 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[升级]]></category>
		<category><![CDATA[工程模式]]></category>
		<category><![CDATA[版本降级]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[降低版本]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11769</guid>
		<description><![CDATA[如何进入工程模式：当设备无法正常开机或者想要降低版本，可以进入工程模式下进行系统升级或者降级。首先把设备关机，然后同时按住“HOME”键和“TEST”键开机，这时设备就会进入工程模... ]]></description>
			<content:encoded><![CDATA[<p>如何进入<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%b7%a5%e7%a8%8b%e6%a8%a1%e5%bc%8f" title="查看 工程模式 的全部文章" target="_blank">工程模式</a></span>：当设备无法正常开机或者想要<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e9%99%8d%e4%bd%8e%e7%89%88%e6%9c%ac" title="查看 降低版本 的全部文章" target="_blank">降低版本</a></span>，可以进入工程模式下进行系统<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%8d%87%e7%ba%a7" title="查看 升级 的全部文章" target="_blank">升级</a></span>或者降级。首先把设备关机，然后同时按住“HOME”键和“TEST”键开机，这时设备就会进入工程模式，把设备通过USB连接到电脑，打开<span class='wp_keywordlink'><a href="http://www.faxytech.com/linkware" title="fluke Linkware">LinkWare</a></span>软件就可以对设备进行升级或者降级（先下载好要升级的版本升级固件）。</p>
<p>&nbsp;</p>
<p>软件版本更多升级细节：<a href="http://www.faxy-tech.com/info/dsx5000-update.html">http://www.faxy-tech.com/info/dsx5000-update.html</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-soft-update.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>横向转换损耗(TCL)和等电平横向转换转移损耗(ELTCTL) -FLUKE DSX2-8000/DSX2-5000参数近端衰减不平衡远端衰减不平衡</title>
		<link>http://www.faxytech.com/archives/tcl-eltctl.html</link>
		<comments>http://www.faxytech.com/archives/tcl-eltctl.html#comments</comments>
		<pubDate>Mon, 11 May 2020 06:59:44 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[ELTCTL]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[TCL]]></category>
		<category><![CDATA[横向转换损耗]]></category>
		<category><![CDATA[等电平横向转换转移损耗]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11473</guid>
		<description><![CDATA[本期我们将讲解两个反映线缆抗干扰能力的重要参数，这两个参数分别是：TCL横向转换损耗和ELTCTL等电平横向转换转移损耗。 TCL横向转化损耗(又名：近端衰减不平衡），ELTCL远端横向转化损耗(... ]]></description>
			<content:encoded><![CDATA[<p>本期我们将讲解两个反映线缆抗干扰能力的重要参数，这两个参数分别是：<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/tcl" title="查看 TCL 的全部文章" target="_blank">TCL</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%a8%aa%e5%90%91%e8%bd%ac%e6%8d%a2%e6%8d%9f%e8%80%97" title="查看 横向转换损耗 的全部文章" target="_blank">横向转换损耗</a></span>和<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/eltctl" title="查看 ELTCTL 的全部文章" target="_blank">ELTCTL</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e7%ad%89%e7%94%b5%e5%b9%b3%e6%a8%aa%e5%90%91%e8%bd%ac%e6%8d%a2%e8%bd%ac%e7%a7%bb%e6%8d%9f%e8%80%97" title="查看 等电平横向转换转移损耗 的全部文章" target="_blank">等电平横向转换转移损耗</a></span>。</p>
<p>TCL横向转化损耗(又名：近端<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>不平衡），ELTCL远端横向转化损耗(又名：远端衰减不平衡）</p>
<p>在讲这两个参数之前，我们先需要思考一个基本问题，为什么用双绞线传输信号？</p>
<p>&nbsp;</p>
<p>其实，双绞线才是真正的平衡传输线。为什么呢？大家在下图中可以看到，中间的表示为辐射干扰源，左边的为平行线示意。由于距离干扰源更近一点，蓝色线对中的实线芯线，将比虚线“积累”更多的干扰能量，我们用红色点代表干扰能量。我们注意到，蓝色实线上的红点“个头”略大，蓝色虚线上的红点个头则略小，这就造成线对末端的两根线上的干扰能量强度，积累后出现明显的“差信号”。 而右边的为改进性能而设计的双绞线，蓝色实线B和蓝色虚线A由于经常相对于干扰辐射源距离远近实现“换位”，即轮番靠近，交替远离。因此线对末端积累的差信号几乎为零，当然前提是线对完全对称，且绞结率足够高。以上就是双绞线能抵消外来干扰的原理。</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/05/TCL.png" class="highslide-image" onclick="return hs.expand(this);"><img class="aligncenter size-full wp-image-11474" title="FLUKE TCL参数" src="http://www.faxytech.com/wp-content/uploads/2020/05/TCL.png" alt="FLUKE TCL参数" width="599" height="390" /></a></p>
<p>&nbsp;</p>
<p>为了让双绞线具有良好的抗干扰能力，首先两根双绞线的长度完全相等，特别是在传输高频信号时；其次，双绞线对的材质和结构尽量均匀、对称。这被称作传输线的平衡性能。传统的考察平衡性的参数有<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>/FEXT，即<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>和远端串扰和 ANEXT/AFEXT，也就是外部近端串扰和外部远端串扰。这些参数主要考察不平衡造成的“线对间干扰”和“缆间干扰”。</p>
<p>&nbsp;</p>
<p>我们这里主要关注的是近端干扰，主要来源于线缆内和线缆间。</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/tcl-eltctl.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>ACR-N、ACR-F、PS ACR-N、PS ACR-F -工程师谈FLUKE DSX2-8000/DSX2-5000参数</title>
		<link>http://www.faxytech.com/archives/dsx-acr.html</link>
		<comments>http://www.faxytech.com/archives/dsx-acr.html#comments</comments>
		<pubDate>Tue, 28 Apr 2020 02:28:56 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[ACR-F]]></category>
		<category><![CDATA[ACR-N]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[PS ACR-F]]></category>
		<category><![CDATA[PS ACR-N]]></category>
		<category><![CDATA[参数]]></category>
		<category><![CDATA[工程师]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11460</guid>
		<description><![CDATA[各位福粉大家好，今天我们给大家讲解一下福禄克双绞线认证测试中的四个测试参数：ACR-N PS ACR-N;ACR-F和PS ACR-F。 ACR是一个缩写，全称为Attenuation-to-Crosstalk Ratio 意思为衰减和串扰的比值，类似... ]]></description>
			<content:encoded><![CDATA[<p>各位福粉大家好，今天我们给大家讲解一下福禄克双绞线认证测试中的四个测试<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%8f%82%e6%95%b0" title="查看 参数 的全部文章" target="_blank">参数</a></span>：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span> PS <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-n" title="查看 ACR-N 的全部文章" target="_blank">ACR-N</a></span>;<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>和PS <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-f" title="查看 ACR-F 的全部文章" target="_blank">ACR-F</a></span>。</p>
<p>ACR是一个缩写，全称为<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="Attenuation">Attenuation</a></span>-to-Crosstalk Ratio 意思为<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>和串扰的比值，类似于信号噪声比的一个概念。从字面意思上就可以看出，这个参数是一个计算值，不是测试值。是由线缆的衰减和串扰计算得来。分贝数值是对数计算得来，在对数计算中，电压比相当于除法又即减法，故ACR是衰减和串扰的分贝差。它可以直观的反应出双绞线系统的有效的，可用的带宽是多少。</p>
<p>ACR参数也分为近端衰减串扰比ACR-N和远端衰减串扰比ACR-F。我们先来看近端衰减串扰比ACR-F。</p>
<p>一对双绞线的接收的信号包含两个部分，一是对端发射过来的信号，这个信号要经过整条链路，所以会收到线对的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>也就是衰减参数的影响，所以这个信号准确的来讲就是经过衰减的有用信号，二就是其他线对的串扰信号，包含<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>信号<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>和远端串扰信号FEXT。还有其他的外来干扰的噪声信号，称为外部串扰，会在其他视频里讲述，这里不做讨论。</p>
<p>ACR-N是近端衰减串扰比，所以是衰减值比上近端串扰值得出。我们把这个公式变化一下，就等于VR接收电平比上VT发送电平的出来的数值再比上VX串扰电平比上VT发送电平的得出来的数值，分母VT约掉得出VR发送电平比上VX串扰电平，近似于信号噪声比的概念。刚才我们提到了端口收到的串扰信号除了近端串扰还有远端串扰，干扰发生在整个链路中，信号会沿着线缆两个方向都会进行传输，传输到信号发射端会产生近端串扰NEXT，传输到信号接收端产生的就是远端串扰FEXT。(参考：<a href="http://www.faxytech.com/archives/dsx-next.html">【系列技术课程】第九讲：铜缆检测参数：NEXT 近端串扰</a>)</p>
<p>用来衡量远端串扰对有效信号影响的参数就是ACR-F。ACR-F的计算方法和ACR-N的计算方法类似，只是把近端串扰电平换为远端串扰电平就可以得到计算结果类似于NEXT和PS NEXT的关系，单纯的ACR-N和ACR-F也不能表示数据接收端口综合的信噪比。因为我们在计算的过程中只取了一对线缆的干扰电平，实际应用中每一对双绞线信号接收端口要收到其他三对线缆的干扰信号，那么<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ps-acr-n" title="查看 PS ACR-N 的全部文章" target="_blank">PS ACR-N</a></span>的计算是经过衰减的有用信号比上其他三对下线缆的干扰噪声总和，才能表示实际的可用带宽，那么取其他三个线对的近端串扰的参数相加计算得到的参数就是PS ACR-N。</p>
<p>那么<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ps-acr-f" title="查看 PS ACR-F 的全部文章" target="_blank">PS ACR-F</a></span>是如何计算出的呢？以及ACR-N和ACR-F的数值是越大越好吗？</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-acr.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>NEXT 近端串扰 -工程师谈FLUKE DSX2-8000/DSX2-5000参数</title>
		<link>http://www.faxytech.com/archives/dsx-next.html</link>
		<comments>http://www.faxytech.com/archives/dsx-next.html#comments</comments>
		<pubDate>Wed, 15 Apr 2020 08:20:15 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[NEXT]]></category>
		<category><![CDATA[近端串扰]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11437</guid>
		<description><![CDATA[本期我们为大家讲解的是NEXT 近端串扰。 首先，我们给大家举个例子有助于大家好理解一下串扰显现，当我们在接听拨打座机时，这时旁边的手机响了，我们会发现座机里会出现非常大的滋滋... ]]></description>
			<content:encoded><![CDATA[<p>本期我们为大家讲解的是<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span> <span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>。</p>
<p>首先，我们给大家举个例子有助于大家好理解一下串扰显现，当我们在接听拨打座机时，这时旁边的手机响了，我们会发现座机里会出现非常大的滋滋噪声，这就是手机的信号进到座机的线缆中被话筒所接收到，听到的滋滋声的噪声就是一种串扰噪声。我们现在使用的双绞线的双绞结构本身目的就是降低线缆收到串扰噪声的影响。</p>
<p>双绞线的串扰就是其中一个线对被相邻的线对的信号串进来所干扰就是串扰。串扰本身是消除不了的，但只要控制在标准所要求以内就不会对网络传输产生大的影响。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/04/NEXT.jpg" class="highslide-image" onclick="return hs.expand(this);"></a></p>
<p><img class="aligncenter size-full wp-image-11438" title="NEXT" src="http://www.faxytech.com/wp-content/uploads/2020/04/NEXT.jpg" alt="" width="562" height="321" /></p>
<p>我们通过上图可以看到左边正常发送信号，当信号在传送中有部分信号泄露出来，到了相邻的线对中这对于相邻线对来说，就是干扰信号，干扰信号会分别向两个方向进行传输，传输到主端设备的干扰信号，叫做<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/next" title="查看 NEXT 的全部文章" target="_blank">NEXT</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%bf%91%e7%ab%af%e4%b8%b2%e6%89%b0" title="查看 近端串扰 的全部文章" target="_blank">近端串扰</a></span>；传输到远端设备的干扰信号，叫做FEXT远端串扰。</p>
<p>&nbsp;</p>
<p>串扰是双绞线在传输信号时是多发的一种干扰。串扰本身类似噪声干扰，串扰的出现会对我们线缆中传输的正常信号会产生非常大的影响，破坏原来正常传输的信号同时也会被错误识别成其他信号，会造成信号出现异常，比如会出现误码、丢包或者乱序、重传等现象。造成网络间歇性时断时续、网络速度比较慢故障。串扰导致故障占到网络故障的大约30%。</p>
<p>&nbsp;</p>
<p>串扰指标不合格大多数是因为线缆本身的质量问题，或者是施工中安装工艺不达标造成的，一般多发在线缆的两端模块位置。</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-next.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>回波损耗-福禄克认证工程师谈FLUKE DSX2-8000/DSX2-5000参数</title>
		<link>http://www.faxytech.com/archives/dsx-rl.html</link>
		<comments>http://www.faxytech.com/archives/dsx-rl.html#comments</comments>
		<pubDate>Thu, 09 Apr 2020 10:15:10 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[fluke dsx2-8000]]></category>
		<category><![CDATA[回波损耗]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[认证工程师]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11419</guid>
		<description><![CDATA[欢迎各位福粉来到我们系列技术课程第八讲，本期我们给大家讲解一下Return Loss，也就是回波损耗。 &#160; &#160; 我们先看看回波损耗定义，由于阻抗不连续或不匹配所造成的信号的反射，其测量... ]]></description>
			<content:encoded><![CDATA[<p>欢迎各位福粉来到我们系列技术课程第八讲，本期我们给大家讲解一下Return Loss，也就是<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/return_loss.html" title="回波损耗">回波损耗</a></span>。</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/04/RL.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="aligncenter size-full wp-image-11420" title="回波损耗" src="http://www.faxytech.com/wp-content/uploads/2020/04/RL.jpg" alt="" width="575" height="336" /></a></p>
<p>&nbsp;</p>
<p>我们先看看<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%9b%9e%e6%b3%a2%e6%8d%9f%e8%80%97" title="查看 回波损耗 的全部文章" target="_blank">回波损耗</a></span>定义，由于<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>不连续或不匹配所造成的信号的反射，其测量是在整个频率范围内进行的。产生阻抗不连续的因素可能来自于线缆和连接器本身，也可能来自于安装工艺。那么，我们首先要理解，什么是阻抗或<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="特性阻抗">特性阻抗</a></span>。</p>
<p>&nbsp;</p>
<p>我们知道，局域网网传输的是高频信号。对于高频信号的传输，我们必须了解传输高频信号的物理介质(比如双绞线、同轴线)的传输特性。这种传输特性与传输介质的材料、几何形状、分布电感、分布电容、导电系数、绝缘材料的介电常数等都有关系。用来衡量这些相关性的，是一个比较复杂的与电磁感应分布参数密切相关的等效参数，只不过，由于这个参数等效计算的结果正好是以欧姆为单位，所以我们把这个参数叫做特性阻抗，有时简称阻抗。具体的，双绞线的阻抗是一个复杂的特性，它是由双绞线的各种物理参数如：电感、电容、电阻的值决定的。而这些值又取决于导体的形状、同心度、导体之间的距离以及电缆绝缘层的材料。<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="综合布线">综合布线</a></span>中，特性阻抗的标准值是100Ω，如果能维持在100±10Ω以内则比较理想。值得注意的是，特性阻抗和欧姆定律中的电阻完全是两个概念，虽然<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/jl.html" title="福禄克计量">计量</a></span>单位都是欧姆，但并不相同。特性阻抗是分布感应参数的等效值，它不随传输线的长度改变而发生变化，而电阻只是与传输线的长度密切相关的一个参数而已。传输线越长，电阻值通常也越大。</p>
<p>&nbsp;</p>
<p>对于双绞线的阻抗分析，我们利用微积分来计算等效阻抗：在均匀长线中取出一微段，等效为一个含电阻、分布电感、分布电容等参数的“四端网络”，将其沿着长度方向积分即可计算出长线的等效阻抗。由于实际制造的所谓长线是不均匀的，所以每一点上面的特性阻抗值都是不相等的，即不连续。</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-rl.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>插入损耗-福禄克认证工程师谈FLUKE DSX2-8000/DSX2-5000参数</title>
		<link>http://www.faxytech.com/archives/dsx-il.html</link>
		<comments>http://www.faxytech.com/archives/dsx-il.html#comments</comments>
		<pubDate>Sun, 05 Apr 2020 10:23:17 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[参数]]></category>
		<category><![CDATA[插入损耗]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[衰减]]></category>
		<category><![CDATA[认证工程师]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11432</guid>
		<description><![CDATA[对布线链路的质量评估呢，仅凭肉眼看是无法判定的，需要依据公认权威的测试标准进行全面测试。而简单的仅仅通过测试打线“线序”，线缆的长度和电阻值是否超标？有没有开路？线缆在... ]]></description>
			<content:encoded><![CDATA[<p>对布线链路的质量评估呢，仅凭肉眼看是无法判定的，需要依据公认权威的测试标准进行全面测试。而简单的仅仅通过测试打线“线序”，线缆的长度和电阻值是否超标？有没有开路？线缆在哪断了？有没有短路？线缆中有没有金属线搭在一起等等，光测这些<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%8f%82%e6%95%b0" title="查看 参数 的全部文章" target="_blank">参数</a></span>是没办法保证电缆和链路的质量的，只能判断一下电缆的连通性。国际和国家标准都规定了一系列与网络链路质量相关的物理参数要求，其中的任何一项或几项不合格，都会导致网络链路性能不稳定，表现出来的网络故障现象是，比如常见的网络闪断，网络时断时续，丢包甚至网络中断，今天我给大家介绍的就是标准里一系列测试参数中非常重要的一项，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>，也称为<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>。</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/04/IL.png" class="highslide-image" onclick="return hs.expand(this);"><img class="aligncenter size-large wp-image-11433" title="IL" src="http://www.faxytech.com/wp-content/uploads/2020/04/IL-1024x498.png" alt="" width="568" height="270" /></a></p>
<p>&nbsp;</p>
<p>按照损耗字面的意思，损耗就是信号在链路传输中，信号强度逐渐由强变弱的过程，大家可以看一下这个片子，信号会由强变弱，信号发出来后经过了线缆，在接收端就收不到信号发送端相同幅度的信号。如果损耗过大，接收端就无法准确接收信号，会造成网络误码和重传。这就好比人在辨别声音的时候，如果传到耳朵里的声音太小，我们就听不到了，就得要求对方重新说一遍。所以为了保证不同品牌不同类型的电缆在一定范围内性能的可靠性，标准规定了不同类型电缆损耗的极限值，这个损耗的极限值是随频率变化的函数，同时标准规定了平衡传输电缆的最大长度的限制，这个我们在讲电缆长度的参数的时候会详细介绍到。</p>
<p>&nbsp;</p>
<p>那么导致损耗或者<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e8%a1%b0%e5%87%8f" title="查看 衰减 的全部文章" target="_blank">衰减</a></span>过大的原因是什么呢？</p>
<p>&nbsp;</p>
<p>一般来说，有以下几个原因，第一呢是由于电缆材质不合格，比如采用的铜的纯度不够，或者采用的是铜包铝或者铜包铁的线缆，第二呢是由于电缆中铜线的结构，使用了比标准规定还细的线规，也会让电缆的衰减增加。还有就是不恰当的端接，<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/impedance-fluke.html" title="阻抗">阻抗</a></span>不匹配，电缆超长等，都是造成损耗的原因。</p>
<p>目前还没有设备可以直接对衰减进行故障定位，但是我们可以采取辅助手段加以分析判断。</p>
<p>&nbsp;</p>
<p>从测试的数据中我们可以看到以下几点：</p>
<p>&nbsp;</p>
<ol>
<li>测试长度是否超长，很显然，电缆越长，衰减越大。比如通道长度超过了100米，损耗也会很大。</li>
<li><span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/resistance.html" title="直流环路电阻">直流环路电阻</a></span>，这是双绞线两根金属芯线的电 阻值之和。线径越细，阻值也 越大。线缆的成分，比如铜的电阻率低，铁的电阻率高，假冒伪劣的铜包铁电缆的阻值会明显偏 大。如果测得环路电阻过大，那么也意味着链路的损耗会比较大。</li>
<li>阻抗是否匹配电缆的结构也会对损耗这个参数有影响，比如，典型的就是在水晶头、插座等部位或者把不同材料的电缆接在一起，引起了阻抗不匹配，形成反射，反射的多了，总的能量就会减少，损耗也会很大。</li>
</ol>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-il.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>线缆长度的意义- 福禄克认证工程师谈FLUKE DSX2-8000/DSX2-5000参数</title>
		<link>http://www.faxytech.com/archives/dsx-length.html</link>
		<comments>http://www.faxytech.com/archives/dsx-length.html#comments</comments>
		<pubDate>Thu, 26 Mar 2020 02:11:36 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[福禄克]]></category>
		<category><![CDATA[长度]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11377</guid>
		<description><![CDATA[先看下长度这个参数，为什么FLUKE DSX2-8000/DSX2-5000要测试长度呢？综合布线中测试线缆的长度有什么重要意义，通过长度信息看线缆故障定位，还有和长度直接相关的NVP值以及测试长度基本原理... ]]></description>
			<content:encoded><![CDATA[<p style="text-align: left;">先看下<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e9%95%bf%e5%ba%a6" title="查看 长度 的全部文章" target="_blank">长度</a></span>这个参数，为什么FLUKE <span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/dsx2-8000.html" title="福禄克FLUKE DSX2-8000">DSX2-8000</a></span>/<span class='wp_keywordlink'><a href="http://www.faxy-tech.com/Products/DSX2-5000.html" title="福禄克FLUKE DSX2-5000">DSX2-5000</a></span>要测试长度呢？<span class='wp_keywordlink'><a href="http://www.faxytech.com" title="综合布线">综合布线</a></span>中测试线缆的长度有什么重要意义，通过长度信息看线缆故障定位，还有和长度直接相关的NVP值以及测试长度基本原理。</p>
<p>长度这个参数非常重要，因为它可以说明很多问题，我们举个和长度相关的例子，假设您是负责管理网络的业主，现在有一个新建机房或者改造升级布线的项目,系统集成商会根据您的需求给出一个解决方案，方案中肯定会涉及网线多少箱（根据布线图纸设计），光纤多少米，连接器面板数量等等，当这个布线项目完工后给您一份工程报告，说明布线按照要求全部完工，综合布线都是正常可以使用，需要您付工程款了。在这个时候建议您多考虑一下，真正了解这个项目综合布线的明细情况吗？项目中实际使用了多少米的网线？每个信息点长度是多少？有没有超标？布线性能到底能不能满足设计要求(万兆/千兆)？这些信息点有没有准确的量化指标？相信您肯定会有这些疑问。</p>
<p>那么FLUKE <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx2-8000" title="查看 DSX2-8000 的全部文章" target="_blank">DSX2-8000</a></span>/<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/dsx2-5000" title="查看 DSX2-5000 的全部文章" target="_blank">DSX2-5000</a></span>可以很直观显示长度和对整个项目，网线整体长度进行汇总。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/03/length-1.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="aligncenter size-full wp-image-11380" title="length-1" src="http://www.faxytech.com/wp-content/uploads/2020/03/length-1.jpg" alt="" width="640" height="280" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/03/length-2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="aligncenter size-full wp-image-11382" title="length-2" src="http://www.faxytech.com/wp-content/uploads/2020/03/length-2.jpg" alt="" width="461" height="300" /></a></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-length.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>传输时延-福禄克认证工程师谈FLUKE DSX2-8000/DSX2-5000参数</title>
		<link>http://www.faxytech.com/archives/dsx-delay.html</link>
		<comments>http://www.faxytech.com/archives/dsx-delay.html#comments</comments>
		<pubDate>Wed, 25 Mar 2020 02:22:07 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[传输时延]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11385</guid>
		<description><![CDATA[传输时延这个参数相对来说好理解，信号从一端传输到另外一端所需要消耗的时间，时延值小说明线缆比较短传输速度就比较快，如果时延值大，那就说明线缆长或者线缆质量较差，那网速就... ]]></description>
			<content:encoded><![CDATA[<p><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e4%bc%a0%e8%be%93%e6%97%b6%e5%bb%b6" title="查看 传输时延 的全部文章" target="_blank">传输时延</a></span>这个参数相对来说好理解，信号从一端传输到另外一端所需要消耗的时间，时延值小说明线缆比较短传输速度就比较快，如果时延值大，那就说明线缆长或者线缆质量较差，那网速就会慢，同时线缆上传输的损耗也就变大了。损耗大那就影响网络的传输，容易出现丢包、重传，延时都会变大，网络自然就不稳定了，这个是连锁反应，传输时延还和我们刚才提到的长度参数是息息相关的，它也与NVP值成反比，所以这个参数也同样很重要。看图，线缆质量差，铜丝粗细拉的不均匀，材质不一样，就会出现传输丢数据,时间就会超长，这是我们不希望看到的，正常标准最大值是555ns。这个范围已经很宽了，如果在测试中超过了极限值，那线缆质量问题就比较严重了。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/03/delay.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="aligncenter size-full wp-image-11386" title="delay" src="http://www.faxytech.com/wp-content/uploads/2020/03/delay.jpg" alt="" width="564" height="330" /></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-delay.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
