		<item>
		<title>ACR-N、ACR-F、PS ACR-N、PS ACR-F -工程师谈FLUKE DSX2-8000/DSX2-5000参数</title>
		<link>http://www.faxytech.com/archives/dsx-acr.html</link>
		<comments>http://www.faxytech.com/archives/dsx-acr.html#comments</comments>
		<pubDate>Tue, 28 Apr 2020 02:28:56 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[ACR-F]]></category>
		<category><![CDATA[ACR-N]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[PS ACR-F]]></category>
		<category><![CDATA[PS ACR-N]]></category>
		<category><![CDATA[参数]]></category>
		<category><![CDATA[工程师]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11460</guid>
		<description><![CDATA[各位福粉大家好，今天我们给大家讲解一下福禄克双绞线认证测试中的四个测试参数：ACR-N PS ACR-N;ACR-F和PS ACR-F。 ACR是一个缩写，全称为Attenuation-to-Crosstalk Ratio 意思为衰减和串扰的比值，类似... ]]></description>
			<content:encoded><![CDATA[<p>各位福粉大家好，今天我们给大家讲解一下福禄克双绞线认证测试中的四个测试<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%8f%82%e6%95%b0" title="查看 参数 的全部文章" target="_blank">参数</a></span>：<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/acr.html" title="ACR-N">ACR-N</a></span> PS <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-n" title="查看 ACR-N 的全部文章" target="_blank">ACR-N</a></span>;<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/acr.html" title="ACR-F">ACR-F</a></span>和PS <span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/acr-f" title="查看 ACR-F 的全部文章" target="_blank">ACR-F</a></span>。</p>
<p>ACR是一个缩写，全称为<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="Attenuation">Attenuation</a></span>-to-Crosstalk Ratio 意思为<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="衰减">衰减</a></span>和串扰的比值，类似于信号噪声比的一个概念。从字面意思上就可以看出，这个参数是一个计算值，不是测试值。是由线缆的衰减和串扰计算得来。分贝数值是对数计算得来，在对数计算中，电压比相当于除法又即减法，故ACR是衰减和串扰的分贝差。它可以直观的反应出双绞线系统的有效的，可用的带宽是多少。</p>
<p>ACR参数也分为近端衰减串扰比ACR-N和远端衰减串扰比ACR-F。我们先来看近端衰减串扰比ACR-F。</p>
<p>一对双绞线的接收的信号包含两个部分，一是对端发射过来的信号，这个信号要经过整条链路，所以会收到线对的<span class='wp_keywordlink'><a href="http://www.faxytech.com/archives/insertion-loss.html" title="插入损耗">插入损耗</a></span>也就是衰减参数的影响，所以这个信号准确的来讲就是经过衰减的有用信号，二就是其他线对的串扰信号，包含<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="近端串扰">近端串扰</a></span>信号<span class='wp_keywordlink'><a href=" http://www.faxytech.com/archives/next.html " title="NEXT">NEXT</a></span>和远端串扰信号FEXT。还有其他的外来干扰的噪声信号，称为外部串扰，会在其他视频里讲述，这里不做讨论。</p>
<p>ACR-N是近端衰减串扰比，所以是衰减值比上近端串扰值得出。我们把这个公式变化一下，就等于VR接收电平比上VT发送电平的出来的数值再比上VX串扰电平比上VT发送电平的得出来的数值，分母VT约掉得出VR发送电平比上VX串扰电平，近似于信号噪声比的概念。刚才我们提到了端口收到的串扰信号除了近端串扰还有远端串扰，干扰发生在整个链路中，信号会沿着线缆两个方向都会进行传输，传输到信号发射端会产生近端串扰NEXT，传输到信号接收端产生的就是远端串扰FEXT。(参考：<a href="http://www.faxytech.com/archives/dsx-next.html">【系列技术课程】第九讲：铜缆检测参数：NEXT 近端串扰</a>)</p>
<p>用来衡量远端串扰对有效信号影响的参数就是ACR-F。ACR-F的计算方法和ACR-N的计算方法类似，只是把近端串扰电平换为远端串扰电平就可以得到计算结果类似于NEXT和PS NEXT的关系，单纯的ACR-N和ACR-F也不能表示数据接收端口综合的信噪比。因为我们在计算的过程中只取了一对线缆的干扰电平，实际应用中每一对双绞线信号接收端口要收到其他三对线缆的干扰信号，那么<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ps-acr-n" title="查看 PS ACR-N 的全部文章" target="_blank">PS ACR-N</a></span>的计算是经过衰减的有用信号比上其他三对下线缆的干扰噪声总和，才能表示实际的可用带宽，那么取其他三个线对的近端串扰的参数相加计算得到的参数就是PS ACR-N。</p>
<p>那么<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/ps-acr-f" title="查看 PS ACR-F 的全部文章" target="_blank">PS ACR-F</a></span>是如何计算出的呢？以及ACR-N和ACR-F的数值是越大越好吗？</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/dsx-acr.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Wire Map 接线图 -福禄克认证工程师谈FLUKE DSX2-8000/DSX2-5000参数</title>
		<link>http://www.faxytech.com/archives/dsx-wiremap.html</link>
		<comments>http://www.faxytech.com/archives/dsx-wiremap.html#comments</comments>
		<pubDate>Sun, 22 Mar 2020 02:34:34 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[DSX2-5000]]></category>
		<category><![CDATA[DSX2-8000]]></category>
		<category><![CDATA[Fluke]]></category>
		<category><![CDATA[Wire Map]]></category>
		<category><![CDATA[参数]]></category>
		<category><![CDATA[工程师]]></category>
		<category><![CDATA[接线图]]></category>
		<category><![CDATA[福禄克]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=11398</guid>
		<description><![CDATA[首先我们聊聊第一个测试参数接线图，什么是接线图呢？顾名思义就是接线的线序规则图。 我们数据网中使用的的网线呢，通常是每根网线里有4对双绞线, 也有一些特殊应用场所使用2对线，比... ]]></description>
			<content:encoded><![CDATA[<p>首先我们聊聊第一个测试<span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e5%8f%82%e6%95%b0" title="查看 参数 的全部文章" target="_blank">参数</a></span><span class='wp_keywordlink_affiliate'><a href="http://www.faxytech.com/tag/%e6%8e%a5%e7%ba%bf%e5%9b%be" title="查看 接线图 的全部文章" target="_blank">接线图</a></span>，什么是接线图呢？顾名思义就是接线的线序规则图。</p>
<p>我们数据网中使用的的网线呢，通常是每根网线里有4对双绞线, 也有一些特殊应用场所使用2对线，比如工控网/工业以太网，还有现场总线以及轨道交通等应用场所仍在大量使用2对线的双绞线。习惯上将这四对双绞线被称作12线对、36线对、45线对和78线对。为什么要按照这个顺序呢？这跟水晶头和连接模块的早期打线规定有关。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/03/wiremap.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="size-full wp-image-11399 alignleft" title="wiremap" src="http://www.faxytech.com/wp-content/uploads/2020/03/wiremap.jpg" alt="" width="545" height="325" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>TIA和ISO以及以太网标准中使用的有两用打线方法，也就是有两种双绞线接线编码方案，T568A和T568B,这两种方案这都起源于美国电话标准 。两个打线方式区别就是橙白和橙在568A当中是36线对，在568B中是12线对。绿白和绿线对正好相反，在568A中是12线对在568B中是36线对。我们检测一根网线的好坏第一步就是要验证他的接线方式是否正确，如果接线方式错误那基础就错误了，一般情况下就没有必要再检测下去了。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/03/wiremap2.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="size-full wp-image-11400 alignleft" title="wiremap2" src="http://www.faxytech.com/wp-content/uploads/2020/03/wiremap2.jpg" alt="" width="550" height="341" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>我们DSX测试仪是可以非常直观的告诉你接线图是否正确，从测试结果可以看出36线对在近端和远端连接反转了，第五根线断在2.4米的地方了。而且45两根线在远端还短路了，所以测试结果显示是失败的。</p>
<p>除了上述的错误我们还可能碰到的错误例如跨接线。这种线通常用于早期的同类设备之间的100Base-Tx互联使用，如果用作设备连接交换机就不可以使用了。所以大家检测过程中如果有碰到这种线也许他不是做错的 ，是网络需要，但是目前这种应用案例越来越少了，大多数情况都是打线错误，电缆一头采用了T568A，而另外一侧用了T568B。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/03/wiremap3.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="size-full wp-image-11401 alignleft" title="wiremap3" src="http://www.faxytech.com/wp-content/uploads/2020/03/wiremap3.jpg" alt="" width="527" height="285" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>刚才聊到的都是整对线多接或者一对线自己两头接反了，给大家看下这种错误，把本该绞在一起的一对线中的一根和另外一对线其中的一根错接在一起，这种错误对网络影响非常严重，我们双绞线本身就是为了降低干扰影响提升传输效率，才把线对两两相绞的，结果这样错接之后不但没有降低干扰反而增强了干扰，所以会导致网络重传多，速度低，甚至是网络中断。不过好在你有DSX系列测试仪可以很简单直观的帮你看到这种错误。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2020/03/wiremap4.jpg" class="highslide-image" onclick="return hs.expand(this);"><img class="size-full wp-image-11402 alignleft" title="wiremap4" src="http://www.faxytech.com/wp-content/uploads/2020/03/wiremap4.jpg" alt="" width="531" height="331" /></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>