<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>专注福禄克测试仪销售与技术 &#187; 交流维修</title>
	<atom:link href="http://www.faxytech.com/tag/%e4%ba%a4%e6%b5%81%e7%bb%b4%e4%bf%ae/feed" rel="self" type="application/rss+xml" />
	<link>http://www.faxytech.com</link>
	<description></description>
	<lastBuildDate>Fri, 02 Feb 2024 02:52:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
		<item>
		<title>FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修</title>
		<link>http://www.faxytech.com/archives/f15b-f17b-wx3.html</link>
		<comments>http://www.faxytech.com/archives/f15b-f17b-wx3.html#comments</comments>
		<pubDate>Fri, 20 May 2016 10:35:43 +0000</pubDate>
		<dc:creator>深圳连讯</dc:creator>
				<category><![CDATA[技术专栏]]></category>
		<category><![CDATA[Fluke 15B+维修]]></category>
		<category><![CDATA[交流维修]]></category>
		<category><![CDATA[福禄克17b+维修]]></category>

		<guid isPermaLink="false">http://www.faxytech.com/?p=7608</guid>
		<description><![CDATA[交流电压挡是跟直流电压挡共用一套分压网络， 检修方法跟直流电压挡基本相似， 首先还是要检查 VΩ 插孔所连接的保护原件 PTC， RV 压敏是否损坏， 如果保护原件没有损坏， 第二步检查波段... ]]></description>
			<content:encoded><![CDATA[<p>交流电压挡是跟直流电压挡共用一套分压网络， 检修方法跟直流电压挡基本相似， 首先还是要检查 VΩ 插孔所连接的保护原件 PTC， RV 压敏是否损坏， 如果保护原件没有损坏， 第二步检查波段开关是否接触不良， 或 V 字片变形， 导致信号没有送进 FS9721 从而导致无法使用，如果没有， 第三步检查交流电压挡和直流电压挡共用的分压网络中的分压电阻是否有虚焊， 开路， 明显烧坏， 如果有的话更换同阻值， 精度一样的分压电阻即可修复， 如果分压电阻均无问题， 则第四步检查交流电压挡中整流器部分， 重点检查的为 CR1 和 CR2 两只整流二极管是否击穿或开路， 如果有的话同型号更换， 如果没有则要检查电位器 R8 1K 是否虚焊或阻值变大， 如果没有的话， 第三步要检查 C6 隔直电容是否开路或漏电， 如果均无问题， 直接更换 FS9721_LP3 来进行修复， 说明是因为 FS9721_LP3 内部的运算放大器损坏导致交流电压挡无法测量。</p>
<p><a href="http://www.faxytech.com/wp-content/uploads/2016/05/f15-f17-wx3.png" class="highslide-image" onclick="return hs.expand(this);"><img class="alignnone size-full wp-image-7609" title="fluke 15B+与fluke 17B+ 交流档不能测量故障维修" src="http://www.faxytech.com/wp-content/uploads/2016/05/f15-f17-wx3.png" alt="" width="656" height="200" /></a></p>
<p>&nbsp;</p>
<p><strong>其他Fluke 15B 与F17B维修参考：</strong></p>
<p><strong>点击</strong>：<a href="http://www.faxytech.com/archives/f15-f17-wx.html">FLUKE 15B+与17B+维修故障1</a><strong><a href="http://www.faxytech.com/archives/f15-f17-wx.html">：</a></strong><a title="福禄克F15B+和F17B+电路故障维修经验系列- 电表开机无任何显示" href="http://www.faxytech.com/archives/f15-f17-wx.html">电表开机无任何显示</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-wx2.html">FLUKE 15B+与17B+维修故障2：直流电压挡无法测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-wx3.html">FLUKE 15B+与17B+维修故障3：交流档不能测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障4：AC/DC 电流挡不能测量故障" href="http://www.faxytech.com/archives/f15b-f17b-wx4.html">FLUKE 15B+与17B+维修故障4：AC/DC 电流挡不能测量故障</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障5：17B 温度挡不能测量故障维修" href="http://www.faxytech.com/archives/f15b-f17b-5.html">FLUKE 15B+与17B+维修故障5：17B 温度挡不能测量故障维修</a></p>
<p><strong>点击：</strong><a title="FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点" href="http://www.faxytech.com/archives/f15-f17-wx6.html">FLUKE 15B+与17B+维修故障6： 万用表开机不显示小数点任何挡位也均不显示小数点</a></p>
<p>&nbsp;</p>
]]></content:encoded>
			<wfw:commentRss>http://www.faxytech.com/archives/f15b-f17b-wx3.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>